Live DB — analyst tables
Test
Amazon 131072 GB200 NVL36x2 Nitro-v5 Hyperscaler EFA Cluster Configuration
AWS-GB200 NVL36x2-EFA-WB
Amazon · GB200 · Nitro-v5
Rack type
NVL36x2
Cluster / location
GB200 NVL36x2 Clusters
Buyer profile
Hyperscaler
Networking type
EFA
Number of XPUs
131,072
NIC used
Nitro-v5
NICs / XPU
2
Scale-out BW / XPU
400G
XPU / server
72
Scale-up network
8 rows
Assigned blockDefault
GB200 - NVL36x2
Scale-UpXPU: GB200 NVL36x28 linesshared by 6 SKUs
Scale-Up Parts Summary
8
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia NVSwitch 5.0 (NVLink 5) | 65,536 | 36.00 | 0.50 |
| NV 1 UltraPass OverPass 72 DP 224Gb/s | 131,072 | 72.00 | 1.00 |
| NV Paladin HD2 224Gb/s 72 DP (Male) | 393,216 | 216.00 | 3.00 |
| NV Paladin HD2 224Gb/s 72 DP (Female) | 393,216 | 216.00 | 3.00 |
| NV 224Gb/s SkewClear EXD Gen 2 Cable | 9,437,184 | 5,184.00 | 72.00 |
| NV OverPass DensiLink UltraPass (NVLink 5) | 589,824 | 324.00 | 4.50 |
| NV 1.6T Twin Port OSFP 2x800G LinkX NVLink5 ACC | 294,912 | 162.00 | 2.25 |
| NVL Spine Chassis (NvLink 5) | 7,282 | 4.00 | 0.06 |
Backend network
7 rows
Assigned blockDefault
GB200 - NVL36x2 - EFAv3 - 3L - ETH - TH3 - AWS
BackendXPU: GB200 NVL36x27 linesshared by 1 SKU
Backend Parts Summary
7
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Generic 400G Y Cable AEC | 131,072 | 72.00 | 1.00 |
| EFAv3 Nitro-v5 200G NIC | 262,144 | 144.00 | 2.00 |
| Generic 400G DR4 | 131,072 | 72.00 | 1.00 |
| Generic 400G Single Mode | 262,144 | 144.00 | 2.00 |
| WhiteBox Tomahawk 3 12.8T | 8,192 | 4.50 | 0.06 |
| Generic 800G DR8 | 196,608 | 108.00 | 1.50 |
| WhiteBox Tomahawk 5 51.2T | 3,072 | 1.69 | 0.02 |
Frontend network
Frontend Parts Summary
0
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|
Compute Tray Networking Content
4 rows
Assigned blockDefault
GB200 - NVL36x2 - AWS - EFA-WB
Compute TrayXPU: GB200 NVL36x24 linesshared by 1 SKU
Compute Tray Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| NV MCIO PCIe x16 Connector | 65,536 | 36.00 | 0.50 |
| NV MCIO PCIe x16 Cable | 65,536 | 36.00 | 0.50 |
| NV DensiLink OverPass to OSFP Cage | 131,072 | 72.00 | 1.00 |
| Astera Labs Scorpio-P 64-Lane PCIe Gen 5.0 | 131,072 | 72.00 | 1.00 |
2026 share
Nvidia NVSwitch 5.0 (NVLink 5)Σ 100%
%
NV 1 UltraPass OverPass 72 DP 224Gb/sΣ 100%
%
NV Paladin HD2 224Gb/s 72 DP (Male)Σ 100%
%
NV Paladin HD2 224Gb/s 72 DP (Female)Σ 100%
%
NV 224Gb/s SkewClear EXD Gen 2 CableΣ 100%
%
NV 1.6T Twin Port OSFP 2x800G LinkX NVLink5 ACCΣ 100%
%
NVL Spine Chassis (NvLink 5)Σ 100%
%
| Item | Unit Cost | Quantity | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Per-server cost: $305,988.00 | |||||||||||||||||||||
| $3,200.00 | 65,536 | 36.00 | 0.50 | $209,715,200.00 | $115,200.00 | 407 W | 26,699,366 W | 14,666 W | Scale-Up Switch | Amazon | Nvidia | — | Device Level | — | — | NVLink | — | GB200 | Scale-Up | AWS-GB200 NVL36x2-EFA-WB | |
| $360.00 | 131,072 | 72.00 | 1.00 | $47,185,920.00 | $25,920.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | — | — | — | GB200 | Scale-Up | AWS-GB200 NVL36x2-EFA-WB | |
| $288.00 | 393,216 | 216.00 | 3.00 | $113,246,208.00 | $62,208.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB200 | Scale-Up | AWS-GB200 NVL36x2-EFA-WB | |
| $144.00 | 393,216 | 216.00 | 3.00 | $56,623,104.00 | $31,104.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB200 | Scale-Up | AWS-GB200 NVL36x2-EFA-WB | |
| $4.00 | 9,437,184 | 5,184.00 | 72.00 | $37,748,736.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB200 | Scale-Up | AWS-GB200 NVL36x2-EFA-WB | |
| $80.00 | 589,824 | 324.00 | 4.50 | $47,185,920.00 | $25,920.00 | 0 W | 0 W | 0 W | Cable | Amazon | Others | Others | White Label | — | — | — | — | GB200 | Scale-Up | AWS-GB200 NVL36x2-EFA-WB | |
| $150.00 | 294,912 | 162.00 | 2.25 | $44,236,800.00 | $24,300.00 | 0 W | 0 W | 0 W | ACC | Amazon | Others | Others | White Label | — | — | — | — | GB200 | Scale-Up | AWS-GB200 NVL36x2-EFA-WB | |
| $150.00 | 7,282 | 4.00 | 0.06 | $1,092,266.67 | $600.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Others | Others | Device Level | — | — | NVLink | — | GB200 | Scale-Up | AWS-GB200 NVL36x2-EFA-WB | |
Per-server cost: $168,686.25 | |||||||||||||||||||||
| $270.00 | 131,072 | 72.00 | 1.00 | $35,389,440.00 | $19,440.00 | 12 W | 1,572,864 W | 864 W | AEC | Amazon | Astera | — | Device Level | — | — | — | — | GB200 | Backend | AWS-GB200 NVL36x2-EFA-WB | |
| $300.00 | 262,144 | 8.00 | 2.00 | $78,643,200.00 | $2,400.00 | 38 W | 9,961,472 W | 304 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | GB200 | Backend | AWS-GB200 NVL36x2-EFA-WB | |
| $260.00 | 131,072 | 72.00 | 1.00 | $34,078,720.00 | $18,720.00 | 10 W | 1,310,720 W | 720 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | GB200 | Backend | AWS-GB200 NVL36x2-EFA-WB | |
| $130.00 | 262,144 | 144.00 | 2.00 | $34,078,720.00 | $18,720.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Amphenol | — | Device Level | — | — | — | — | GB200 | Backend | AWS-GB200 NVL36x2-EFA-WB | |
| $5,000.00 | 8,192 | 4.50 | 0.06 | $40,960,000.00 | $22,500.00 | 450 W | 3,686,400 W | 2,025 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | GB200 | Backend | AWS-GB200 NVL36x2-EFA-WB | |
| $500.00 | 196,608 | 108.00 | 1.50 | $98,304,000.00 | $54,000.00 | 16 W | 3,145,728 W | 1,728 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | GB200 | Backend | AWS-GB200 NVL36x2-EFA-WB | |
| $19,500.00 | 3,072 | 1.69 | 0.02 | $59,904,000.00 | $32,906.25 | 1,200 W | 3,686,400 W | 2,025 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | GB200 | Backend | AWS-GB200 NVL36x2-EFA-WB | |
Per-server cost: $14,805.00 | |||||||||||||||||||||
| $1.25 | 65,536 | 36.00 | 0.50 | $81,920.00 | $45.00 | 0 W | 0 W | 0 W | Connector | Amazon | Amphenol | Amphenol | White Label | — | — | — | — | GB200 | Compute Tray | AWS-GB200 NVL36x2-EFA-WB | |
| $35.00 | 65,536 | 36.00 | 0.50 | $2,293,760.00 | $1,260.00 | 0 W | 0 W | 0 W | Cable | Amazon | Amphenol | Amphenol | White Label | — | — | — | — | GB200 | Compute Tray | AWS-GB200 NVL36x2-EFA-WB | |
| $37.50 | 131,072 | 72.00 | 1.00 | $4,915,200.00 | $2,700.00 | 0 W | 0 W | 0 W | Cable | Amazon | Amphenol | Amphenol | White Label | — | — | — | — | GB200 | Compute Tray | AWS-GB200 NVL36x2-EFA-WB | |
| $150.00 | 131,072 | 72.00 | 1.00 | $19,660,800.00 | $10,800.00 | 130 W | 17,039,360 W | 9,360 W | Scale-Up Switch | Amazon | Astera | — | Device Level | — | — | PCIe | — | GB200 | Compute Tray | AWS-GB200 NVL36x2-EFA-WB | |
| By fabric | |||||||||||||||||||||
| Total Scale-Up | $557,034,154.67 | $305,988.00 | 26,699,366 W | 14,666 W | |||||||||||||||||
| Total Backend | $381,358,080.00 | $168,686.25 | 23,363,584 W | 7,666 W | |||||||||||||||||
| Total Compute Tray | $26,951,680.00 | $14,805.00 | 17,039,360 W | 9,360 W | |||||||||||||||||
| Grand Total Cluster Networking | $965,343,914.67 | $489,479.25 | 67,102,310 W | 31,692 W | |||||||||||||||||
| By component | |||||||||||||||||||||
| Total Transceivers | $132,382,720.00 | $72,720.00 | 4,456,448 W | 2,448 W | |||||||||||||||||
| Total Switches | $100,864,000.00 | $55,406.25 | 7,372,800 W | 4,050 W | |||||||||||||||||
| Total Fiber | $34,078,720.00 | $18,720.00 | 0 W | 0 W | |||||||||||||||||
| Total Cables | $54,394,880.00 | $29,880.00 | 0 W | 0 W | |||||||||||||||||
| Total Connectors | $81,920.00 | $45.00 | 0 W | 0 W | |||||||||||||||||
| Total NICs | $78,643,200.00 | $2,400.00 | 9,961,472 W | 304 W | |||||||||||||||||