HS-Feynman NVL1152-CX10-IB-4R
HS-Feynman NVL1152-CX10-IB-4R
Default Hyperscaler · Feynman · CX10
Rack type
Kyber NVL1152
Cluster / location
Default Hyperscaler Kyber NVL 1152 x800 Q3400 (non-CPO)
Buyer profile
Hyperscaler
Networking type
Infiniband
Number of XPUs
93,312
NIC used
CX10
NICs / XPU
3
Scale-out BW / XPU
4.8T
XPU / server
1,152
Scale-up network
8 rows
Assigned blockDefault
Feynman - Kyber NVL1152
Scale-UpXPU: Feynman Kyber NVL11528 linesshared by 11 SKUs
Scale-Up Parts Summary
8
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia NVSwitch 8.0 (NVLink 8) | 46,656 | 576.00 | 0.50 |
| NV 3.2T Optical Engine (OE) for NVLink Switch side CPO | 489,888 | 6,048.00 | 5.25 |
| NV 1.6T 8 Fiber Pair FAU | 1,959,552 | 24,192.00 | 21.00 |
| NV External Laser Source (ELS) 8 LD 6.4T for NVLink CPO Switch | 244,944 | 3,024.00 | 2.63 |
| NV Sentry HD 448Gb/s 144DP (Male) | 186,624 | 2,304.00 | 2.00 |
| NV Sentry HD 448Gb/s 144DP (Female) | 186,624 | 2,304.00 | 2.00 |
| NVL Blade Column Spine Chassis (NvLink 7) | 1,296 | 16.00 | 0.01 |
| NVL Kyber Canister Midplane PCB (NvLink 7) | 648 | 8.00 | 0.01 |
Backend network
4 rows
Assigned blockDefault
Feynman - Kyber NVL1152 - CX10 - 3L - IB - X800-Q3400-RA - Generic
BackendXPU: Feynman Kyber NVL11524 linesshared by 2 SKUs
Backend Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia LinkX 1.6T DR8 (SiPho) | 1,492,992 | 18,432.00 | 16.00 |
| Nvidia LinkX 800G Single Mode | 1,679,616 | 20,736.00 | 18.00 |
| ConnectX-10 NIC - 1.6T | 279,936 | 3,456.00 | 3.00 |
| Quantum-X800-Q3400-RA (Air Cooled) | 19,440 | 240.00 | 0.21 |
Frontend network
11 rows
Assigned blockDefault
Feynman - Kyber NVL1152 - SN6600 - Generic
FrontendXPU: Feynman Kyber NVL115211 linesshared by 11 SKUs
Frontend Parts Summary
11
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Spectrum-6 102.4T x1600 (SN6600) | 1,120 | 14 | 0.0120 |
| Spectrum-4 25.6T (SN5400) | 5 | 0 | 0.0001 |
| Spectrum-3 12.8T (SN4700) | 167 | 2 | 0.0018 |
| Spectrum-2 6.4T (SN3700) | 1,370 | 17 | 0.0147 |
| Nvidia LinkX 1.6T DR8 (SiPho) | 54,187 | 669 | 0.5807 |
| Nvidia LinkX 800G DR4 | 53,904 | 665 | 0.5777 |
| Nvidia LinkX 200G SR4 | 23,920 | 295 | 0.2563 |
| Nvidia LinkX 800G Multimode | 74,159 | 916 | 0.7947 |
| Nvidia LinkX 400G Multimode | 380 | 5 | 0.0041 |
| Nvidia LinkX 200G Multimode | 10,655 | 132 | 0.1142 |
| RJ45 Cables | 65,763 | 812 | 0.7048 |
Compute Tray Networking Content
4 rows
Assigned blockDefault
Feynman - Kyber NVL1152 - Generic
Compute TrayXPU: Feynman Kyber NVL11524 linesshared by 11 SKUs
Compute Tray Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| NV Paladin Board to Board 32 Pin 4p8c (Male) | 93,312 | 1,152.00 | 1.00 |
| NV Paladin Board to Board 64 Pin 4p16c (Male) | 373,248 | 4,608.00 | 4.00 |
| NV Paladin Board to Board 32 Pin 4p8c (Female) | 93,312 | 1,152.00 | 1.00 |
| NV Paladin Board to Board 64 Pin 4p16c (Female) | 373,248 | 4,608.00 | 4.00 |
2026 share
RJ45 CablesΣ 100%
%
| Item | Unit Cost | Quantity | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Per-server cost: $23,172,961.14 | |||||||||||||||||||||
| $16,428.57 | 46,656 | 576.00 | 0.50 | $766,491,428.59 | $9,462,857.14 | 800 W | 37,324,800 W | 460,800 W | Scale-Up Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | NVLink | — | Feynman | Scale-Up | HS-Feynman NVL1152-CX10-IB-4R | |
| $400.00 | 489,888 | 6,048.00 | 5.25 | $195,955,200.00 | $2,419,200.00 | 13 W | 6,172,589 W | 76,205 W | — | Default Hyperscaler | Others | Others | White Label | — | — | NVLink | — | Feynman | Scale-Up | HS-Feynman NVL1152-CX10-IB-4R | |
| $160.00 | 1,959,552 | 24,192.00 | 21.00 | $313,528,320.00 | $3,870,720.00 | 0 W | 0 W | 0 W | — | Default Hyperscaler | Others | Others | White Label | — | — | NVLink | — | Feynman | Scale-Up | HS-Feynman NVL1152-CX10-IB-4R | |
| $1,200.00 | 244,944 | 3,024.00 | 2.63 | $293,932,800.00 | $3,628,800.00 | 8 W | 1,959,552 W | 24,192 W | — | Default Hyperscaler | Others | Others | White Label | — | — | NVLink | — | Feynman | Scale-Up | HS-Feynman NVL1152-CX10-IB-4R | |
| $864.00 | 186,624 | 2,304.00 | 2.00 | $161,243,136.00 | $1,990,656.00 | 0 W | 0 W | 0 W | Backplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 448G | NVLink | — | Feynman | Scale-Up | HS-Feynman NVL1152-CX10-IB-4R | |
| $432.00 | 186,624 | 2,304.00 | 2.00 | $80,621,568.00 | $995,328.00 | 0 W | 0 W | 0 W | Backplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 448G | NVLink | — | Feynman | Scale-Up | HS-Feynman NVL1152-CX10-IB-4R | |
| $337.50 | 1,296 | 16.00 | 0.01 | $437,400.00 | $5,400.00 | 0 W | 0 W | 0 W | Backplane | Default Hyperscaler | Others | Others | Device Level | — | — | NVLink | — | Feynman | Scale-Up | HS-Feynman NVL1152-CX10-IB-4R | |
| $100,000.00 | 648 | 8.00 | 0.01 | $64,800,000.00 | $800,000.00 | 0 W | 0 W | 0 W | Backplane | Default Hyperscaler | Others | Others | Device Level | — | — | NVLink | — | Feynman | Scale-Up | HS-Feynman NVL1152-CX10-IB-4R | |
Per-server cost: $57,938,987.23 | |||||||||||||||||||||
| $1,723.40 | 1,492,992 | 18,432.00 | 16.00 | $2,573,028,765.48 | $31,765,787.23 | 22 W | 32,845,824 W | 405,504 W | Transceiver | Default Hyperscaler | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | Feynman | Backend | HS-Feynman NVL1152-CX10-IB-4R | |
| $450.00 | 1,679,616 | 20,736.00 | 18.00 | $755,827,200.00 | $9,331,200.00 | 0 W | 0 W | 0 W | Fiber | Default Hyperscaler | Others | — | White Label | — | — | — | — | Feynman | Backend | HS-Feynman NVL1152-CX10-IB-4R | |
| $3,500.00 | 279,936 | 12.00 | 3.00 | $979,776,000.00 | $42,000.00 | 100 W | 27,993,600 W | 1,200 W | NIC | Default Hyperscaler | Nvidia | — | Device Level | — | — | — | — | Feynman | Backend | HS-Feynman NVL1152-CX10-IB-4R | |
| $70,000.00 | 19,440 | 240.00 | 0.21 | $1,360,800,000.00 | $16,800,000.00 | 2,800 W | 54,432,000 W | 672,000 W | Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | — | — | Feynman | Backend | HS-Feynman NVL1152-CX10-IB-4R | |
Per-server cost: $3,507,013.76 | |||||||||||||||||||||
| $32,526.91 | 1,120 | 13.83 | 0.01 | $36,433,858.74 | $449,800.73 | 1,344 W | 1,504,877 W | 18,579 W | Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | Ethernet | — | Feynman | Frontend | HS-Feynman NVL1152-CX10-IB-4R | |
| $15,000.00 | 5 | 0.06 | 0.00 | $69,428.57 | $857.14 | 670 W | 3,101 W | 38 W | Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | Ethernet | — | Feynman | Frontend | HS-Feynman NVL1152-CX10-IB-4R | |
| $21,600.00 | 167 | 2.06 | 0.00 | $3,599,177.13 | $44,434.29 | 630 W | 104,976 W | 1,296 W | Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | Ethernet | — | Feynman | Frontend | HS-Feynman NVL1152-CX10-IB-4R | |
| $13,273.51 | 1,370 | 16.91 | 0.01 | $18,185,462.36 | $224,511.88 | 250 W | 342,514 W | 4,229 W | Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | Ethernet | — | Feynman | Frontend | HS-Feynman NVL1152-CX10-IB-4R | |
| $1,723.40 | 54,187 | 668.97 | 0.58 | $93,385,564.72 | $1,152,908.21 | 22 W | 1,192,107 W | 14,717 W | Transceiver | Default Hyperscaler | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | Feynman | Frontend | HS-Feynman NVL1152-CX10-IB-4R | |
| $1,511.63 | 53,904 | 665.49 | 0.58 | $81,483,308.97 | $1,005,966.78 | 17 W | 916,374 W | 11,313 W | Transceiver | Default Hyperscaler | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | Feynman | Frontend | HS-Feynman NVL1152-CX10-IB-4R | |
| $325.00 | 23,920 | 295.31 | 0.26 | $7,774,148.57 | $95,977.14 | 5 W | 119,602 W | 1,477 W | Transceiver | Default Hyperscaler | Nvidia | Mellanox, Others | White Label | — | 56G | InfiniBand | Fully Retimed | Feynman | Frontend | HS-Feynman NVL1152-CX10-IB-4R | |
| $525.00 | 74,159 | 915.54 | 0.79 | $38,933,460.00 | $480,660.00 | 0 W | 0 W | 0 W | Fiber | Default Hyperscaler | Others | — | White Label | — | — | — | — | Feynman | Frontend | HS-Feynman NVL1152-CX10-IB-4R | |
| $375.00 | 380 | 4.69 | 0.00 | $142,328.57 | $1,757.14 | 0 W | 0 W | 0 W | Fiber | Default Hyperscaler | Others | — | White Label | — | — | — | — | Feynman | Frontend | HS-Feynman NVL1152-CX10-IB-4R | |
| $375.00 | 10,655 | 131.54 | 0.11 | $3,995,614.29 | $49,328.57 | 0 W | 0 W | 0 W | Fiber | Default Hyperscaler | Others | — | White Label | — | — | — | — | Feynman | Frontend | HS-Feynman NVL1152-CX10-IB-4R | |
| $1.00 | 65,763 | 811.89 | 0.70 | $65,762.74 | $811.89 | 0 W | 0 W | 0 W | Cable | Default Hyperscaler | Amphenol | — | Device Level | — | — | — | — | Feynman | Frontend | HS-Feynman NVL1152-CX10-IB-4R | |
Per-server cost: $995,328.00 | |||||||||||||||||||||
| $64.00 | 93,312 | 1,152.00 | 1.00 | $5,971,968.00 | $73,728.00 | 0 W | 0 W | 0 W | Midplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Feynman | Compute Tray | HS-Feynman NVL1152-CX10-IB-4R | |
| $128.00 | 373,248 | 4,608.00 | 4.00 | $47,775,744.00 | $589,824.00 | 0 W | 0 W | 0 W | Midplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Feynman | Compute Tray | HS-Feynman NVL1152-CX10-IB-4R | |
| $32.00 | 93,312 | 1,152.00 | 1.00 | $2,985,984.00 | $36,864.00 | 0 W | 0 W | 0 W | Midplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Feynman | Compute Tray | HS-Feynman NVL1152-CX10-IB-4R | |
| $64.00 | 373,248 | 4,608.00 | 4.00 | $23,887,872.00 | $294,912.00 | 0 W | 0 W | 0 W | Midplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Feynman | Compute Tray | HS-Feynman NVL1152-CX10-IB-4R | |
| By fabric | |||||||||||||||||||||
| Total Scale-Up | $1,877,009,852.59 | $23,172,961.14 | 45,456,941 W | 561,197 W | |||||||||||||||||
| Total Backend | $5,669,431,965.48 | $57,938,987.23 | 115,271,424 W | 1,078,704 W | |||||||||||||||||
| Total Frontend | $284,068,114.66 | $3,507,013.76 | 4,183,551 W | 51,649 W | |||||||||||||||||
| Total Compute Tray | $80,621,568.00 | $995,328.00 | 0 W | 0 W | |||||||||||||||||
| Grand Total Cluster Networking | $7,911,131,500.73 | $85,614,290.13 | 164,911,916 W | 1,691,550 W | |||||||||||||||||
| By component | |||||||||||||||||||||
| Total Transceivers | $2,755,671,787.75 | $34,020,639.35 | 35,073,907 W | 433,011 W | |||||||||||||||||
| Total Switches | $1,419,087,926.79 | $17,519,604.03 | 56,387,468 W | 696,142 W | |||||||||||||||||
| Total Fiber | $798,898,602.86 | $9,862,945.71 | 0 W | 0 W | |||||||||||||||||
| Total Cables | $65,762.74 | $811.89 | 0 W | 0 W | |||||||||||||||||
| Total Connectors | — | — | — | — | |||||||||||||||||
| Total NICs | $979,776,000.00 | $42,000.00 | 27,993,600 W | 1,200 W | |||||||||||||||||