Live DB — analyst tables
Test
Google 131072 VR200 CX-9 Hyperscaler Ethernet Cluster Configuration
GOOG-VR200-CX9-SX6-8P-2L
Google · VR200 · CX-9
Rack type
NVL72
Cluster / location
All Other Clusters
Buyer profile
Hyperscaler
Networking type
Ethernet
Number of XPUs
131,072
NIC used
CX-9
NICs / XPU
2
Scale-out BW / XPU
1.6T
XPU / server
72
Scale-up network
7 rows
Assigned blockDefault
VR200 - NVL72
Scale-UpXPU: VR200 NVL727 linesshared by 31 SKUs
Scale-Up Parts Summary
7
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia NVSwitch 6.0 (NVLink 6) | 65,536 | 36.00 | 0.50 |
| NV Paladin HD2 224Gb/s 144 Bidi (Male) | 65,536 | 36.00 | 0.50 |
| NV Paladin HD2 224Gb/s 144 Bidi (Female) | 65,536 | 36.00 | 0.50 |
| NV Paladin HD2 224Gb/s 72 Bidi (Male) | 131,072 | 72.00 | 1.00 |
| NV Paladin HD2 224Gb/s 72 Bidi (Female) | 9,437,184 | 5,184.00 | 72.00 |
| NV 224Gb/s SkewClear EXD Gen 2 Bidi Cable | 9,437,184 | 5,184.00 | 72.00 |
| NVL Spine Chassis (NvLink 6) | 3,641 | 2.00 | 0.03 |
Backend network
5 rows
Assigned blockDefault
VR200 - NVL72 - CX9 - 2L - ETH - TH6 - GOOG
BackendXPU: VR200 NVL725 linesshared by 1 SKU
Backend Parts Summary
5
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Generic 800G DR4 | 262,144 | 144.00 | 2.00 |
| Generic 800G DR4 Single Mode | 524,288 | 288.00 | 4.00 |
| Generic 1.6T DR8 (SiPho) | 393,216 | 216.00 | 3.00 |
| ConnectX-9 NIC - 800G | 262,144 | 144.00 | 2.00 |
| WhiteBox Tomahawk 6 102.4T | 6,144 | 3.38 | 0.05 |
Frontend network
11 rows
Assigned blockDefault
VR200 - NVL72 - WhiteBox TH6 - GOOG
FrontendXPU: VR200 NVL7211 linesshared by 1 SKU
Frontend Parts Summary
11
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| WhiteBox Tomahawk 6 102.4T 512 Radix | 1,573 | 1 | 0.0120 |
| WhiteBox Tomahawk 4 25.6T | 7 | 0 | 0.0001 |
| WhiteBox Tomahawk 3 12.8T | 234 | 0 | 0.0018 |
| WhiteBox Tomahawk 2 6.4T | 1,924 | 1 | 0.0147 |
| Generic 1.6T DR8 (SiPho) | 76,114 | 42 | 0.5807 |
| Generic 800G DR4 | 75,717 | 42 | 0.5777 |
| Generic 200G SR4 | 33,600 | 18 | 0.2563 |
| Generic 800G Single Mode | 104,168 | 57 | 0.7947 |
| Generic 400G Multimode | 533 | 0 | 0.0041 |
| Generic 200G Multimode | 14,967 | 8 | 0.1142 |
| RJ45 Cables | 92,375 | 51 | 0.7048 |
Compute Tray Networking Content
4 rows
Assigned blockDefault
VR200 - NVL72 - Generic
Compute TrayXPU: VR200 NVL724 linesshared by 31 SKUs
Compute Tray Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| NV Paladin Board to Board 32 Pin 4p8c (Male) | 131,072 | 72.00 | 1.00 |
| NV Paladin Board to Board 64 Pin 4p16c (Male) | 524,288 | 288.00 | 4.00 |
| NV Paladin Board to Board 32 Pin 4p8c (Female) | 131,072 | 72.00 | 1.00 |
| NV Paladin Board to Board 64 Pin 4p16c (Female) | 524,288 | 288.00 | 4.00 |
2026 share
Nvidia NVSwitch 6.0 (NVLink 6)Σ 100%
%
NV Paladin HD2 224Gb/s 144 Bidi (Male)Σ 100%
%
NV Paladin HD2 224Gb/s 144 Bidi (Female)Σ 100%
%
NV Paladin HD2 224Gb/s 72 Bidi (Male)Σ 100%
%
NV Paladin HD2 224Gb/s 72 Bidi (Female)Σ 100%
%
| Item | Unit Cost | Quantity | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Per-server cost: $963,522.00 | |||||||||||||||||||||
| $4,000.00 | 65,536 | 36.00 | 0.50 | $262,144,000.00 | $144,000.00 | 650 W | 42,598,400 W | 23,400 W | Scale-Up Switch | Nvidia | — | Device Level | — | — | NVLink | — | VR200 | Scale-Up | GOOG-VR200-CX9-SX6-8P-2L | ||
| $576.00 | 65,536 | 36.00 | 0.50 | $37,748,736.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Scale-Up | GOOG-VR200-CX9-SX6-8P-2L | ||
| $288.00 | 65,536 | 36.00 | 0.50 | $18,874,368.00 | $10,368.00 | 0 W | 0 W | 0 W | Backplane | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Scale-Up | GOOG-VR200-CX9-SX6-8P-2L | ||
| $288.00 | 131,072 | 72.00 | 1.00 | $37,748,736.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Scale-Up | GOOG-VR200-CX9-SX6-8P-2L | ||
| $144.00 | 9,437,184 | 5,184.00 | 72.00 | $1,358,954,496.00 | $746,496.00 | 0 W | 0 W | 0 W | Backplane | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Scale-Up | GOOG-VR200-CX9-SX6-8P-2L | ||
| $4.00 | 9,437,184 | 5,184.00 | 72.00 | $37,748,736.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Scale-Up | GOOG-VR200-CX9-SX6-8P-2L | ||
| $225.00 | 3,641 | 2.00 | 0.03 | $819,200.00 | $450.00 | 0 W | 0 W | 0 W | Backplane | Others | Others | Device Level | — | — | NVLink | — | VR200 | Scale-Up | GOOG-VR200-CX9-SX6-8P-2L | ||
Per-server cost: $454,200.00 | |||||||||||||||||||||
| $650.00 | 262,144 | 144.00 | 2.00 | $170,393,600.00 | $93,600.00 | 17 W | 4,456,448 W | 2,448 W | Transceiver | AAOI | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Backend | GOOG-VR200-CX9-SX6-8P-2L | ||
| $130.00 | 524,288 | 288.00 | 4.00 | $68,157,440.00 | $37,440.00 | 0 W | 0 W | 0 W | Fiber | Corning | — | Device Level | — | — | — | — | VR200 | Backend | GOOG-VR200-CX9-SX6-8P-2L | ||
| $810.00 | 393,216 | 216.00 | 3.00 | $318,504,960.00 | $174,960.00 | 22 W | 8,650,752 W | 4,752 W | Transceiver | AAOI | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Backend | GOOG-VR200-CX9-SX6-8P-2L | ||
| $1,650.00 | 262,144 | 8.00 | 2.00 | $432,537,600.00 | $13,200.00 | 90 W | 23,592,960 W | 720 W | NIC | Nvidia | — | Device Level | — | — | — | — | VR200 | Backend | GOOG-VR200-CX9-SX6-8P-2L | ||
| $40,000.00 | 6,144 | 3.38 | 0.05 | $245,760,000.00 | $135,000.00 | 1,697 W | 10,426,714 W | 5,728 W | Switch | Accton | — | Device Level | — | — | — | — | VR200 | Backend | GOOG-VR200-CX9-SX6-8P-2L | ||
Per-server cost: $113,439.85 | |||||||||||||||||||||
| $40,000.00 | 1,573 | 0.86 | 0.01 | $62,935,365.08 | $34,571.43 | 1,700 W | 2,674,753 W | 1,469 W | Switch | Accton | — | Device Level | — | — | — | — | VR200 | Frontend | GOOG-VR200-CX9-SX6-8P-2L | ||
| $13,500.00 | 7 | 0.00 | 0.00 | $87,771.42 | $48.21 | 850 W | 5,526 W | 3 W | Switch | Accton | — | Device Level | — | — | — | — | VR200 | Frontend | GOOG-VR200-CX9-SX6-8P-2L | ||
| $5,000.00 | 234 | 0.13 | 0.00 | $1,170,285.72 | $642.86 | 450 W | 105,326 W | 58 W | Switch | Accton | — | Device Level | — | — | — | — | VR200 | Frontend | GOOG-VR200-CX9-SX6-8P-2L | ||
| $3,072.57 | 1,924 | 1.06 | 0.01 | $5,913,070.11 | $3,248.15 | 250 W | 481,117 W | 264 W | Switch | Accton | — | Device Level | — | — | — | — | VR200 | Frontend | GOOG-VR200-CX9-SX6-8P-2L | ||
| $810.00 | 76,114 | 41.81 | 0.58 | $61,652,406.86 | $33,866.68 | 22 W | 1,674,510 W | 920 W | Transceiver | AAOI | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Frontend | GOOG-VR200-CX9-SX6-8P-2L | ||
| $650.00 | 75,717 | 41.59 | 0.58 | $49,216,365.71 | $27,035.36 | 17 W | 1,287,197 W | 707 W | Transceiver | AAOI | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Frontend | GOOG-VR200-CX9-SX6-8P-2L | ||
| $130.00 | 33,600 | 18.46 | 0.26 | $4,368,026.41 | $2,399.43 | 5 W | 168,001 W | 92 W | Transceiver | AAOI | — | Device Level | — | 56G | Ethernet | Fully Retimed | VR200 | Frontend | GOOG-VR200-CX9-SX6-8P-2L | ||
| $180.00 | 104,168 | 57.22 | 0.79 | $18,750,317.71 | $10,299.86 | 0 W | 0 W | 0 W | Fiber | Corning | — | Device Level | — | — | — | — | VR200 | Frontend | GOOG-VR200-CX9-SX6-8P-2L | ||
| $150.00 | 533 | 0.29 | 0.00 | $79,969.52 | $43.93 | 0 W | 0 W | 0 W | Fiber | Others | — | Device Level | — | — | — | — | VR200 | Frontend | GOOG-VR200-CX9-SX6-8P-2L | ||
| $150.00 | 14,967 | 8.22 | 0.11 | $2,244,998.10 | $1,233.21 | 0 W | 0 W | 0 W | Fiber | Corning | — | Device Level | — | — | — | — | VR200 | Frontend | GOOG-VR200-CX9-SX6-8P-2L | ||
| $1.00 | 92,375 | 50.74 | 0.70 | $92,374.55 | $50.74 | 0 W | 0 W | 0 W | Cable | Amphenol | — | Device Level | — | — | — | — | VR200 | Frontend | GOOG-VR200-CX9-SX6-8P-2L | ||
Per-server cost: $62,208.00 | |||||||||||||||||||||
| $64.00 | 131,072 | 72.00 | 1.00 | $8,388,608.00 | $4,608.00 | 0 W | 0 W | 0 W | Midplane | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Compute Tray | GOOG-VR200-CX9-SX6-8P-2L | ||
| $128.00 | 524,288 | 288.00 | 4.00 | $67,108,864.00 | $36,864.00 | 0 W | 0 W | 0 W | Midplane | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Compute Tray | GOOG-VR200-CX9-SX6-8P-2L | ||
| $32.00 | 131,072 | 72.00 | 1.00 | $4,194,304.00 | $2,304.00 | 0 W | 0 W | 0 W | Midplane | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Compute Tray | GOOG-VR200-CX9-SX6-8P-2L | ||
| $64.00 | 524,288 | 288.00 | 4.00 | $33,554,432.00 | $18,432.00 | 0 W | 0 W | 0 W | Midplane | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Compute Tray | GOOG-VR200-CX9-SX6-8P-2L | ||
| By fabric | |||||||||||||||||||||
| Total Scale-Up | $1,754,038,272.00 | $963,522.00 | 42,598,400 W | 23,400 W | |||||||||||||||||
| Total Backend | $1,235,353,600.00 | $454,200.00 | 47,126,874 W | 13,648 W | |||||||||||||||||
| Total Frontend | $206,510,951.20 | $113,439.85 | 6,396,431 W | 3,514 W | |||||||||||||||||
| Total Compute Tray | $113,246,208.00 | $62,208.00 | 0 W | 0 W | |||||||||||||||||
| Grand Total Cluster Networking | $3,309,149,031.20 | $1,593,369.85 | 96,121,704 W | 40,561 W | |||||||||||||||||
| By component | |||||||||||||||||||||
| Total Transceivers | $604,135,358.98 | $331,861.46 | 16,236,908 W | 8,919 W | |||||||||||||||||
| Total Switches | $315,866,492.33 | $173,510.65 | 13,693,436 W | 7,522 W | |||||||||||||||||
| Total Fiber | $89,232,725.33 | $49,017.00 | 0 W | 0 W | |||||||||||||||||
| Total Cables | $92,374.55 | $50.74 | 0 W | 0 W | |||||||||||||||||
| Total Connectors | — | — | — | — | |||||||||||||||||
| Total NICs | $432,537,600.00 | $13,200.00 | 23,592,960 W | 720 W | |||||||||||||||||