Live DB — analyst tables
Test
Default Hyperscaler 131072 Rubin Ultra NVL576 CX-9 Hyperscaler Spectrum X Cluster Configuration
HS-RU NVL576-CX9-SX6-8P-2L
Default Hyperscaler · Rubin Ultra · CX-9
Rack type
NVL576
Cluster / location
Default Rubin Ultra
Buyer profile
Hyperscaler
Networking type
Spectrum X
Number of XPUs
131,072
NIC used
CX-9
NICs / XPU
4
Scale-out BW / XPU
3.2T
XPU / server
576
Scale-up network
8 rows
Assigned blockDefault
Rubin Ultra - NVL576
Scale-UpXPU: Rubin Ultra NVL5768 linesshared by 11 SKUs
Scale-Up Parts Summary
8
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia NVSwitch 7.0 (NVLink 7) - 28.8T | 196,608 | 864.00 | 1.50 |
| NV 3.2T Optical Engine (OE) for NVLink Switch side CPO | 2,359,296 | 10,368.00 | 18.00 |
| NV 1.6T 8 Fiber Pair FAU | 2,359,296 | 10,368.00 | 18.00 |
| NV External Laser Source (ELS) 8 LD 6.4T for NVLink CPO Switch | 589,824 | 2,592.00 | 4.50 |
| NV Sentry HD 448Gb/s 72DP (Male) | 262,144 | 1,152.00 | 2.00 |
| NV Sentry HD 448Gb/s 72DP (Female) | 262,144 | 1,152.00 | 2.00 |
| NVL Blade Column Spine Chassis (NvLink 7) | 9,437,184 | 41,472.00 | 72.00 |
| NV 224Gb/s SkewClear EXD Gen 2 Bidi Cable | 9,437,184 | 41,472.00 | 72.00 |
Backend network
5 rows
Assigned blockDefault
Rubin Ultra - NVL576 - CX9 - 2L - ETH - SN6600 - Generic
BackendXPU: Rubin Ultra NVL5765 linesshared by 2 SKUs
Backend Parts Summary
5
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia LinkX 800G DR4 | 524,288 | 2,304.00 | 4.00 |
| Nvidia LinkX 800G Single Mode | 1,048,576 | 4,608.00 | 8.00 |
| Nvidia LinkX 1.6T DR8 (SiPho) | 786,432 | 3,456.00 | 6.00 |
| ConnectX-9 NIC - 800G | 524,288 | 2,304.00 | 4.00 |
| Spectrum-6 102.4T x1600 (SN6600) | 12,288 | 54.00 | 0.09 |
Frontend network
11 rows
Assigned blockDefault
Rubin Ultra - NVL576 - SN6600 - Generic
FrontendXPU: Rubin Ultra NVL57611 linesshared by 11 SKUs
Frontend Parts Summary
11
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Spectrum-6 102.4T x1600 (SN6600) | 1,120 | 5 | 0.0085 |
| Spectrum-4 25.6T (SN5400) | 5 | 0 | 0.0000 |
| Spectrum-3 12.8T (SN4700) | 167 | 1 | 0.0013 |
| Spectrum-2 6.4T (SN3700) | 1,370 | 6 | 0.0105 |
| Nvidia LinkX 1.6T DR8 (SiPho) | 54,187 | 238 | 0.4134 |
| Nvidia LinkX 800G DR4 | 53,904 | 237 | 0.4113 |
| Nvidia LinkX 200G SR4 | 23,920 | 105 | 0.1825 |
| Nvidia LinkX 800G Multimode | 74,159 | 326 | 0.5658 |
| Nvidia LinkX 400G Multimode | 380 | 2 | 0.0029 |
| Nvidia LinkX 200G Multimode | 10,655 | 47 | 0.0813 |
| RJ45 Cables | 65,763 | 289 | 0.5017 |
Compute Tray Networking Content
4 rows
Assigned blockDefault
Rubin Ultra - NVL576 - Generic
Compute TrayXPU: Rubin Ultra NVL5764 linesshared by 11 SKUs
Compute Tray Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| NV Paladin Board to Board 32 Pin 4p8c (Male) | 131,072 | 576.00 | 1.00 |
| NV Paladin Board to Board 64 Pin 4p16c (Male) | 524,288 | 2,304.00 | 4.00 |
| NV Paladin Board to Board 32 Pin 4p8c (Female) | 131,072 | 576.00 | 1.00 |
| NV Paladin Board to Board 64 Pin 4p16c (Female) | 524,288 | 2,304.00 | 4.00 |
2026 share
Nvidia NVSwitch 7.0 (NVLink 7) - 28.8TΣ 100%
%
NV 3.2T Optical Engine (OE) for NVLink Switch side CPOΣ 100%
%
NV 1.6T 8 Fiber Pair FAUΣ 100%
%
NV External Laser Source (ELS) 8 LD 6.4T for NVLink CPO SwitchΣ 100%
%
NV Sentry HD 448Gb/s 72DP (Male)Σ 100%
%
NV Sentry HD 448Gb/s 72DP (Female)Σ 100%
%
NVL Blade Column Spine Chassis (NvLink 7)Σ 100%
%
NV 224Gb/s SkewClear EXD Gen 2 Bidi CableΣ 100%
%
| Item | Unit Cost | Quantity | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Per-server cost: $27,281,664.00 | |||||||||||||||||||||
| $4,000.00 | 196,608 | 864.00 | 1.50 | $786,432,000.00 | $3,456,000.00 | 800 W | 157,286,400 W | 691,200 W | Scale-Up Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | NVLink | — | Rubin Ultra | Scale-Up | HS-RU NVL576-CX9-SX6-8P-2L | |
| $400.00 | 2,359,296 | 10,368.00 | 18.00 | $943,718,400.00 | $4,147,200.00 | 13 W | 29,727,130 W | 130,637 W | — | Default Hyperscaler | Others | Others | White Label | — | — | NVLink | — | Rubin Ultra | Scale-Up | HS-RU NVL576-CX9-SX6-8P-2L | |
| $160.00 | 2,359,296 | 10,368.00 | 18.00 | $377,487,360.00 | $1,658,880.00 | 0 W | 0 W | 0 W | — | Default Hyperscaler | Others | Others | White Label | — | — | NVLink | — | Rubin Ultra | Scale-Up | HS-RU NVL576-CX9-SX6-8P-2L | |
| $1,200.00 | 589,824 | 2,592.00 | 4.50 | $707,788,800.00 | $3,110,400.00 | 8 W | 4,718,592 W | 20,736 W | — | Default Hyperscaler | Others | Others | White Label | — | — | NVLink | — | Rubin Ultra | Scale-Up | HS-RU NVL576-CX9-SX6-8P-2L | |
| $432.00 | 262,144 | 1,152.00 | 2.00 | $113,246,208.00 | $497,664.00 | 0 W | 0 W | 0 W | Backplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 448G | NVLink | — | Rubin Ultra | Scale-Up | HS-RU NVL576-CX9-SX6-8P-2L | |
| $216.00 | 262,144 | 1,152.00 | 2.00 | $56,623,104.00 | $248,832.00 | 0 W | 0 W | 0 W | Backplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 448G | NVLink | — | Rubin Ultra | Scale-Up | HS-RU NVL576-CX9-SX6-8P-2L | |
| $337.50 | 9,437,184 | 41,472.00 | 72.00 | $3,185,049,600.00 | $13,996,800.00 | 0 W | 0 W | 0 W | Backplane | Default Hyperscaler | Others | Others | Device Level | — | — | NVLink | — | Rubin Ultra | Scale-Up | HS-RU NVL576-CX9-SX6-8P-2L | |
| $4.00 | 9,437,184 | 41,472.00 | 72.00 | $37,748,736.00 | $165,888.00 | 0 W | 0 W | 0 W | Backplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Rubin Ultra | Scale-Up | HS-RU NVL576-CX9-SX6-8P-2L | |
Per-server cost: $13,295,329.05 | |||||||||||||||||||||
| $1,511.63 | 524,288 | 2,304.00 | 4.00 | $792,528,372.11 | $3,482,790.70 | 17 W | 8,912,896 W | 39,168 W | Transceiver | Default Hyperscaler | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | Rubin Ultra | Backend | HS-RU NVL576-CX9-SX6-8P-2L | |
| $450.00 | 1,048,576 | 4,608.00 | 8.00 | $471,859,200.00 | $2,073,600.00 | 0 W | 0 W | 0 W | Fiber | Default Hyperscaler | Others | — | White Label | — | — | — | — | Rubin Ultra | Backend | HS-RU NVL576-CX9-SX6-8P-2L | |
| $1,723.40 | 786,432 | 3,456.00 | 6.00 | $1,355,340,255.07 | $5,956,085.11 | 22 W | 17,301,504 W | 76,032 W | Transceiver | Default Hyperscaler | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | Rubin Ultra | Backend | HS-RU NVL576-CX9-SX6-8P-2L | |
| $1,650.00 | 524,288 | 16.00 | 4.00 | $865,075,200.00 | $26,400.00 | 90 W | 47,185,920 W | 1,440 W | NIC | Default Hyperscaler | Nvidia | — | Device Level | — | — | — | — | Rubin Ultra | Backend | HS-RU NVL576-CX9-SX6-8P-2L | |
| $32,526.91 | 12,288 | 54.00 | 0.09 | $399,690,693.86 | $1,756,453.24 | 1,344 W | 16,508,963 W | 72,549 W | Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | Ethernet | — | Rubin Ultra | Backend | HS-RU NVL576-CX9-SX6-8P-2L | |
Per-server cost: $1,753,506.88 | |||||||||||||||||||||
| $32,526.91 | 1,573 | 6.91 | 0.01 | $51,177,326.94 | $224,900.36 | 1,344 W | 2,113,846 W | 9,289 W | Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | Ethernet | — | Rubin Ultra | Frontend | HS-RU NVL576-CX9-SX6-8P-2L | |
| $15,000.00 | 7 | 0.03 | 0.00 | $97,523.81 | $428.57 | 670 W | 4,356 W | 19 W | Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | Ethernet | — | Rubin Ultra | Frontend | HS-RU NVL576-CX9-SX6-8P-2L | |
| $21,600.00 | 234 | 1.03 | 0.00 | $5,055,634.29 | $22,217.14 | 630 W | 147,456 W | 648 W | Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | Ethernet | — | Rubin Ultra | Frontend | HS-RU NVL576-CX9-SX6-8P-2L | |
| $13,273.51 | 1,924 | 8.46 | 0.01 | $25,544,462.89 | $112,255.94 | 250 W | 481,117 W | 2,114 W | Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | Ethernet | — | Rubin Ultra | Frontend | HS-RU NVL576-CX9-SX6-8P-2L | |
| $1,723.40 | 76,114 | 334.49 | 0.58 | $131,175,333.71 | $576,454.10 | 22 W | 1,674,510 W | 7,359 W | Transceiver | Default Hyperscaler | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | Rubin Ultra | Frontend | HS-RU NVL576-CX9-SX6-8P-2L | |
| $1,511.63 | 75,717 | 332.74 | 0.58 | $114,456,664.45 | $502,983.39 | 17 W | 1,287,197 W | 5,657 W | Transceiver | Default Hyperscaler | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | Rubin Ultra | Frontend | HS-RU NVL576-CX9-SX6-8P-2L | |
| $325.00 | 33,600 | 147.66 | 0.26 | $10,920,066.03 | $47,988.57 | 5 W | 168,001 W | 738 W | Transceiver | Default Hyperscaler | Nvidia | Mellanox, Others | White Label | — | 56G | InfiniBand | Fully Retimed | Rubin Ultra | Frontend | HS-RU NVL576-CX9-SX6-8P-2L | |
| $525.00 | 104,168 | 457.77 | 0.79 | $54,688,426.67 | $240,330.00 | 0 W | 0 W | 0 W | Fiber | Default Hyperscaler | Others | — | White Label | — | — | — | — | Rubin Ultra | Frontend | HS-RU NVL576-CX9-SX6-8P-2L | |
| $375.00 | 533 | 2.34 | 0.00 | $199,923.81 | $878.57 | 0 W | 0 W | 0 W | Fiber | Default Hyperscaler | Others | — | White Label | — | — | — | — | Rubin Ultra | Frontend | HS-RU NVL576-CX9-SX6-8P-2L | |
| $375.00 | 14,967 | 65.77 | 0.11 | $5,612,495.24 | $24,664.29 | 0 W | 0 W | 0 W | Fiber | Default Hyperscaler | Others | — | White Label | — | — | — | — | Rubin Ultra | Frontend | HS-RU NVL576-CX9-SX6-8P-2L | |
| $1.00 | 92,375 | 405.94 | 0.70 | $92,374.55 | $405.94 | 0 W | 0 W | 0 W | Cable | Default Hyperscaler | Amphenol | — | Device Level | — | — | — | — | Rubin Ultra | Frontend | HS-RU NVL576-CX9-SX6-8P-2L | |
Per-server cost: $497,664.00 | |||||||||||||||||||||
| $64.00 | 131,072 | 576.00 | 1.00 | $8,388,608.00 | $36,864.00 | 0 W | 0 W | 0 W | Midplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Rubin Ultra | Compute Tray | HS-RU NVL576-CX9-SX6-8P-2L | |
| $128.00 | 524,288 | 2,304.00 | 4.00 | $67,108,864.00 | $294,912.00 | 0 W | 0 W | 0 W | Midplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Rubin Ultra | Compute Tray | HS-RU NVL576-CX9-SX6-8P-2L | |
| $32.00 | 131,072 | 576.00 | 1.00 | $4,194,304.00 | $18,432.00 | 0 W | 0 W | 0 W | Midplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Rubin Ultra | Compute Tray | HS-RU NVL576-CX9-SX6-8P-2L | |
| $64.00 | 524,288 | 2,304.00 | 4.00 | $33,554,432.00 | $147,456.00 | 0 W | 0 W | 0 W | Midplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Rubin Ultra | Compute Tray | HS-RU NVL576-CX9-SX6-8P-2L | |
| By fabric | |||||||||||||||||||||
| Total Scale-Up | $6,208,094,208.00 | $27,281,664.00 | 191,732,122 W | 842,573 W | |||||||||||||||||
| Total Backend | $3,884,493,721.03 | $13,295,329.05 | 89,909,283 W | 189,189 W | |||||||||||||||||
| Total Frontend | $399,020,232.39 | $1,753,506.88 | 5,876,484 W | 25,824 W | |||||||||||||||||
| Total Compute Tray | $113,246,208.00 | $497,664.00 | 0 W | 0 W | |||||||||||||||||
| Grand Total Cluster Networking | $10,604,854,369.42 | $42,828,163.93 | 287,517,889 W | 1,057,586 W | |||||||||||||||||
| By component | |||||||||||||||||||||
| Total Transceivers | $2,404,420,691.37 | $10,566,301.87 | 29,344,108 W | 128,954 W | |||||||||||||||||
| Total Switches | $481,565,641.78 | $2,116,255.26 | 19,255,739 W | 84,620 W | |||||||||||||||||
| Total Fiber | $532,360,045.71 | $2,339,472.86 | 0 W | 0 W | |||||||||||||||||
| Total Cables | $92,374.55 | $405.94 | 0 W | 0 W | |||||||||||||||||
| Total Connectors | — | — | — | — | |||||||||||||||||
| Total NICs | $865,075,200.00 | $26,400.00 | 47,185,920 W | 1,440 W | |||||||||||||||||