Live DB — analyst tables
Test
Meta 103680 VR200 CX-9 Hyperscaler Ethernet Cluster Configuration
META-VR200-CX9-NSF-NPO-DEF
Meta · VR200 · CX-9
Rack type
NVL72
Cluster / location
All Other Clusters
Buyer profile
Hyperscaler
Networking type
Ethernet
Number of XPUs
103,680
NIC used
CX-9
NICs / XPU
2
Scale-out BW / XPU
1.6T
XPU / server
72
Scale-up network
7 rows
Assigned blockDefault
VR200 - NVL72
Scale-UpXPU: VR200 NVL727 linesshared by 31 SKUs
Scale-Up Parts Summary
7
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia NVSwitch 6.0 (NVLink 6) | 51,840 | 36.00 | 0.50 |
| NV Paladin HD2 224Gb/s 144 Bidi (Male) | 51,840 | 36.00 | 0.50 |
| NV Paladin HD2 224Gb/s 144 Bidi (Female) | 51,840 | 36.00 | 0.50 |
| NV Paladin HD2 224Gb/s 72 Bidi (Male) | 103,680 | 72.00 | 1.00 |
| NV Paladin HD2 224Gb/s 72 Bidi (Female) | 7,464,960 | 5,184.00 | 72.00 |
| NV 224Gb/s SkewClear EXD Gen 2 Bidi Cable | 7,464,960 | 5,184.00 | 72.00 |
| NVL Spine Chassis (NvLink 6) | 2,880 | 2.00 | 0.03 |
Backend network
6 rows
Assigned blockDefault
VR200 - NVL72 - CX9 - 4L - ETH - TH6 - META
BackendXPU: VR200 NVL726 linesshared by 1 SKU
Backend Parts Summary
6
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Generic 800G DR4 | 207,360 | 144.00 | 2.00 |
| Generic 800G DR4 Single Mode | 207,360 | 144.00 | 2.00 |
| ConnectX-9 NIC - 800G | 207,360 | 144.00 | 2.00 |
| Generic Tomahawk 6 102.4T NPO | 10,320 | 7.17 | 0.10 |
| Generic 800G 2xFR4 | 103,680 | 72.00 | 1.00 |
| Arista 144T Modular Chassis (7800R4) | 288 | 0.20 | 0.00 |
Frontend network
11 rows
Assigned blockDefault
VR200 - NVL72 - Minipack-4 - META
FrontendXPU: VR200 NVL7211 linesshared by 6 SKUs
Frontend Parts Summary
11
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Minipack-4 OCP Rack 102.4T | 1,245 | 1 | 0.0120 |
| Minipack-2 OCP Rack 25.6T | 5 | 0 | 0.0001 |
| Minipack-1 OCP Rack 12.8T | 185 | 0 | 0.0018 |
| Generic 1GbE Ethernet | 1,522 | 1 | 0.0147 |
| Generic 1.6T DR8 (SiPho) | 60,207 | 42 | 0.5807 |
| Generic 800G DR4 | 59,894 | 42 | 0.5777 |
| Generic 200G DR4 QSFP56 | 26,578 | 18 | 0.2563 |
| Generic 800G Single Mode | 82,399 | 57 | 0.7947 |
| Generic 400G Single Mode | 422 | 0 | 0.0041 |
| Generic 200G Single Mode | 11,839 | 8 | 0.1142 |
| RJ45 Cables | 73,070 | 51 | 0.7048 |
Compute Tray Networking Content
4 rows
Assigned blockDefault
VR200 - NVL72 - Generic
Compute TrayXPU: VR200 NVL724 linesshared by 31 SKUs
Compute Tray Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| NV Paladin Board to Board 32 Pin 4p8c (Male) | 103,680 | 72.00 | 1.00 |
| NV Paladin Board to Board 64 Pin 4p16c (Male) | 414,720 | 288.00 | 4.00 |
| NV Paladin Board to Board 32 Pin 4p8c (Female) | 103,680 | 72.00 | 1.00 |
| NV Paladin Board to Board 64 Pin 4p16c (Female) | 414,720 | 288.00 | 4.00 |
2026 share
Nvidia NVSwitch 6.0 (NVLink 6)Σ 100%
%
NV Paladin HD2 224Gb/s 144 Bidi (Male)Σ 100%
%
NV Paladin HD2 224Gb/s 144 Bidi (Female)Σ 100%
%
NV Paladin HD2 224Gb/s 72 Bidi (Male)Σ 100%
%
NV Paladin HD2 224Gb/s 72 Bidi (Female)Σ 100%
%
NV 224Gb/s SkewClear EXD Gen 2 Bidi CableΣ 100%
%
| Item | Unit Cost | Quantity | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Per-server cost: $963,522.00 | |||||||||||||||||||||
| $4,000.00 | 51,840 | 36.00 | 0.50 | $207,360,000.00 | $144,000.00 | 650 W | 33,696,000 W | 23,400 W | Scale-Up Switch | Meta | Nvidia | — | Device Level | — | — | NVLink | — | VR200 | Scale-Up | META-VR200-CX9-NSF-NPO-DEF | |
| $576.00 | 51,840 | 36.00 | 0.50 | $29,859,840.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Meta | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Scale-Up | META-VR200-CX9-NSF-NPO-DEF | |
| $288.00 | 51,840 | 36.00 | 0.50 | $14,929,920.00 | $10,368.00 | 0 W | 0 W | 0 W | Backplane | Meta | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Scale-Up | META-VR200-CX9-NSF-NPO-DEF | |
| $288.00 | 103,680 | 72.00 | 1.00 | $29,859,840.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Meta | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Scale-Up | META-VR200-CX9-NSF-NPO-DEF | |
| $144.00 | 7,464,960 | 5,184.00 | 72.00 | $1,074,954,240.00 | $746,496.00 | 0 W | 0 W | 0 W | Backplane | Meta | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Scale-Up | META-VR200-CX9-NSF-NPO-DEF | |
| $4.00 | 7,464,960 | 5,184.00 | 72.00 | $29,859,840.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Meta | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Scale-Up | META-VR200-CX9-NSF-NPO-DEF | |
| $225.00 | 2,880 | 2.00 | 0.03 | $648,000.00 | $450.00 | 0 W | 0 W | 0 W | Backplane | Meta | Others | Others | Device Level | — | — | NVLink | — | VR200 | Scale-Up | META-VR200-CX9-NSF-NPO-DEF | |
Per-server cost: $647,365.74 | |||||||||||||||||||||
| $650.00 | 207,360 | 144.00 | 2.00 | $134,784,000.00 | $93,600.00 | 17 W | 3,525,120 W | 2,448 W | Transceiver | Meta | AAOI | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Backend | META-VR200-CX9-NSF-NPO-DEF | |
| $130.00 | 207,360 | 144.00 | 2.00 | $26,956,800.00 | $18,720.00 | 0 W | 0 W | 0 W | Fiber | Meta | Corning | — | Device Level | — | — | — | — | VR200 | Backend | META-VR200-CX9-NSF-NPO-DEF | |
| $1,650.00 | 207,360 | 8.00 | 2.00 | $342,144,000.00 | $13,200.00 | 90 W | 18,662,400 W | 720 W | NIC | Meta | Nvidia | — | Device Level | — | — | — | — | VR200 | Backend | META-VR200-CX9-NSF-NPO-DEF | |
| $64,283.00 | 10,320 | 7.17 | 0.10 | $663,400,560.00 | $460,694.83 | 1,000 W | 10,320,000 W | 7,167 W | Switch | Meta | Broadcom | — | Device Level | — | 224G | Ethernet | NPO | VR200 | Backend | META-VR200-CX9-NSF-NPO-DEF | |
| $480.00 | 103,680 | 72.00 | 1.00 | $49,766,400.00 | $34,560.00 | 15 W | 1,555,200 W | 1,080 W | Transceiver | Meta | Coherent | — | Device Level | — | 112G | Ethernet | Fully Retimed | VR200 | Backend | META-VR200-CX9-NSF-NPO-DEF | |
| $132,954.55 | 288 | 0.20 | 0.00 | $38,290,909.09 | $26,590.91 | 2,500 W | 720,000 W | 500 W | Switch | Meta | Arista | — | Device Level | — | — | — | — | VR200 | Backend | META-VR200-CX9-NSF-NPO-DEF | |
Per-server cost: $115,081.99 | |||||||||||||||||||||
| $45,000.00 | 1,245 | 0.86 | 0.01 | $56,005,714.31 | $38,892.86 | 1,300 W | 1,617,943 W | 1,124 W | Switch | Meta | Celestica | — | Device Level | — | — | — | — | VR200 | Frontend | META-VR200-CX9-NSF-NPO-DEF | |
| $13,500.00 | 5 | 0.00 | 0.00 | $69,428.57 | $48.21 | 850 W | 4,371 W | 3 W | Switch | Meta | Celestica | — | Device Level | — | — | — | — | VR200 | Frontend | META-VR200-CX9-NSF-NPO-DEF | |
| $5,000.00 | 185 | 0.13 | 0.00 | $925,714.28 | $642.86 | 450 W | 83,314 W | 58 W | Switch | Meta | Celestica | — | Device Level | — | — | — | — | VR200 | Frontend | META-VR200-CX9-NSF-NPO-DEF | |
| $350.00 | 1,522 | 1.06 | 0.01 | $532,800.00 | $370.00 | 100 W | 152,229 W | 106 W | Switch | Meta | Accton | — | Device Level | — | — | — | — | VR200 | Frontend | META-VR200-CX9-NSF-NPO-DEF | |
| $810.00 | 60,207 | 41.81 | 0.58 | $48,768,017.14 | $33,866.68 | 22 W | 1,324,563 W | 920 W | Transceiver | Meta | AAOI | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Frontend | META-VR200-CX9-NSF-NPO-DEF | |
| $650.00 | 59,894 | 41.59 | 0.58 | $38,930,914.29 | $27,035.36 | 17 W | 1,018,193 W | 707 W | Transceiver | Meta | AAOI | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Frontend | META-VR200-CX9-NSF-NPO-DEF | |
| $150.00 | 26,578 | 18.46 | 0.26 | $3,986,742.86 | $2,768.57 | 5 W | 132,891 W | 92 W | Transceiver | Meta | AAOI | — | Device Level | — | 56G | Ethernet | Fully Retimed | VR200 | Frontend | META-VR200-CX9-NSF-NPO-DEF | |
| $180.00 | 82,399 | 57.22 | 0.79 | $14,831,794.29 | $10,299.86 | 0 W | 0 W | 0 W | Fiber | Meta | Corning | — | Device Level | — | — | — | — | VR200 | Frontend | META-VR200-CX9-NSF-NPO-DEF | |
| $130.00 | 422 | 0.29 | 0.00 | $54,822.86 | $38.07 | 0 W | 0 W | 0 W | Fiber | Meta | Amphenol | — | Device Level | — | — | — | — | VR200 | Frontend | META-VR200-CX9-NSF-NPO-DEF | |
| $130.00 | 11,839 | 8.22 | 0.11 | $1,539,051.43 | $1,068.79 | 0 W | 0 W | 0 W | Fiber | Meta | Corning | — | Device Level | — | — | — | — | VR200 | Frontend | META-VR200-CX9-NSF-NPO-DEF | |
| $1.00 | 73,070 | 50.74 | 0.70 | $73,069.71 | $50.74 | 0 W | 0 W | 0 W | Cable | Meta | Amphenol | — | Device Level | — | — | — | — | VR200 | Frontend | META-VR200-CX9-NSF-NPO-DEF | |
Per-server cost: $62,208.00 | |||||||||||||||||||||
| $64.00 | 103,680 | 72.00 | 1.00 | $6,635,520.00 | $4,608.00 | 0 W | 0 W | 0 W | Midplane | Meta | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Compute Tray | META-VR200-CX9-NSF-NPO-DEF | |
| $128.00 | 414,720 | 288.00 | 4.00 | $53,084,160.00 | $36,864.00 | 0 W | 0 W | 0 W | Midplane | Meta | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Compute Tray | META-VR200-CX9-NSF-NPO-DEF | |
| $32.00 | 103,680 | 72.00 | 1.00 | $3,317,760.00 | $2,304.00 | 0 W | 0 W | 0 W | Midplane | Meta | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Compute Tray | META-VR200-CX9-NSF-NPO-DEF | |
| $64.00 | 414,720 | 288.00 | 4.00 | $26,542,080.00 | $18,432.00 | 0 W | 0 W | 0 W | Midplane | Meta | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Compute Tray | META-VR200-CX9-NSF-NPO-DEF | |
| By fabric | |||||||||||||||||||||
| Total Scale-Up | $1,387,471,680.00 | $963,522.00 | 33,696,000 W | 23,400 W | |||||||||||||||||
| Total Backend | $1,255,342,669.09 | $647,365.74 | 34,782,720 W | 11,915 W | |||||||||||||||||
| Total Frontend | $165,718,069.73 | $115,081.99 | 4,333,505 W | 3,009 W | |||||||||||||||||
| Total Compute Tray | $89,579,520.00 | $62,208.00 | 0 W | 0 W | |||||||||||||||||
| Grand Total Cluster Networking | $2,898,111,938.82 | $1,788,177.74 | 72,812,225 W | 38,324 W | |||||||||||||||||
| By component | |||||||||||||||||||||
| Total Transceivers | $276,236,074.29 | $191,830.61 | 7,555,968 W | 5,247 W | |||||||||||||||||
| Total Switches | $759,225,126.25 | $527,239.67 | 12,897,857 W | 8,957 W | |||||||||||||||||
| Total Fiber | $43,382,468.57 | $30,126.71 | 0 W | 0 W | |||||||||||||||||
| Total Cables | $73,069.71 | $50.74 | 0 W | 0 W | |||||||||||||||||
| Total Connectors | — | — | — | — | |||||||||||||||||
| Total NICs | $342,144,000.00 | $13,200.00 | 18,662,400 W | 720 W | |||||||||||||||||