Neocloud Giant 73728 GB300 CX-8 Neocloud Giant Spectrum X Cluster Configuration
NG-GB300-CX8-IB-NV-3L
Neocloud Giant · GB300 · CX-8
Rack type
NVL72
Cluster / location
Default Neocloud GB300 SpectrumX 4-Plane 4 Rack per SU
Buyer profile
Neocloud Giant
Networking type
Spectrum X
Number of XPUs
73,728
NIC used
CX-8
NICs / XPU
1
Scale-out BW / XPU
800G
XPU / server
72
Scale-up network
8 rows
Assigned blockDefault
GB300 - NVL72
Scale-UpXPU: GB300 NVL728 linesshared by 22 SKUs
Scale-Up Parts Summary
8
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia NVSwitch 5.0 (NVLink 5) | 18,432 | 18.00 | 0.25 |
| NV 2 UltraPass OverPass 144 DP 224Gb/s | 36,864 | 36.00 | 0.50 |
| NV Paladin HD2 224Gb/s 144 DP (Male) | 36,864 | 36.00 | 0.50 |
| NV Paladin HD2 224Gb/s 144 DP (Female) | 36,864 | 36.00 | 0.50 |
| NV Paladin HD2 224Gb/s 72 DP (Male) | 73,728 | 72.00 | 1.00 |
| NV Paladin HD2 224Gb/s 72 DP (Female) | 73,728 | 72.00 | 1.00 |
| NV 224Gb/s SkewClear EXD Gen 2 Cable | 5,308,416 | 5,184.00 | 72.00 |
| NVL Spine Chassis (NvLink 5) | 2,048 | 2.00 | 0.03 |
Backend network
5 rows
Assigned blockDefault
GB300 - NVL72 - CX8 - 3L - IB - X800-Q3400-RA - Generic
BackendXPU: GB300 NVL725 linesshared by 1 SKU
Backend Parts Summary
5
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia LinkX 800G DR4 | 73,728 | 72.00 | 1.00 |
| Nvidia LinkX 800G DR4 Single Mode | 221,184 | 216.00 | 3.00 |
| Nvidia LinkX 1.6T DR8 (SiPho) | 184,320 | 180.00 | 2.50 |
| ConnectX-8 NIC - 800G | 73,728 | 72.00 | 1.00 |
| Quantum-X800-Q3400-RA (Air Cooled) | 2,560 | 2.50 | 0.03 |
Frontend network
11 rows
Assigned blockDefault
GB300 - NVL72 - SN5600 - Generic
FrontendXPU: GB300 NVL7211 linesshared by 10 SKUs
Frontend Parts Summary
11
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Spectrum-4 51.2T (SN5600) | 1,573 | 2 | 0.0213 |
| Spectrum-3 12.8T (SN4700) | 7 | 0 | 0.0001 |
| Spectrum-2 6.4T (SN3700) | 234 | 0 | 0.0032 |
| Spectrum-2 1GbE (SN2201) | 1,924 | 2 | 0.0261 |
| Nvidia LinkX 800G SR8 | 76,114 | 74 | 1.0324 |
| Nvidia LinkX 400G SR4 | 75,717 | 74 | 1.0270 |
| Nvidia LinkX 100G SR4 QSFP28 | 33,600 | 33 | 0.4557 |
| Nvidia LinkX 800G Multimode | 104,168 | 102 | 1.4129 |
| Nvidia LinkX 400G Multimode | 533 | 1 | 0.0072 |
| Nvidia LinkX 100G Multimode | 14,967 | 15 | 0.2030 |
| RJ45 Cables | 92,375 | 90 | 1.2529 |
Compute Tray Networking Content
3 rows
Assigned blockDefault
GB300 - NVL72 - Generic
Compute TrayXPU: GB300 NVL723 linesshared by 20 SKUs
Compute Tray Parts Summary
3
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| NV MCIO PCIe x16 Connector | 36,864 | 36.00 | 0.50 |
| NV MCIO PCIe x16 Cable | 36,864 | 36.00 | 0.50 |
| NV DensiLink OverPass to OSFP Cage | 73,728 | 72.00 | 1.00 |
2026 share
Nvidia NVSwitch 5.0 (NVLink 5)Σ 100%
%
NV 2 UltraPass OverPass 144 DP 224Gb/sΣ 100%
%
NV Paladin HD2 224Gb/s 144 DP (Male)Σ 100%
%
NV Paladin HD2 224Gb/s 144 DP (Female)Σ 100%
%
NV Paladin HD2 224Gb/s 72 DP (Male)Σ 100%
%
NV Paladin HD2 224Gb/s 72 DP (Female)Σ 100%
%
NV 224Gb/s SkewClear EXD Gen 2 CableΣ 100%
%
NVL Spine Chassis (NvLink 5)Σ 100%
%
| Item | Unit Cost | Quantity | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Per-server cost: $166,764.00 | |||||||||||||||||||||
| $3,200.00 | 18,432 | 18.00 | 0.25 | $58,982,400.00 | $57,600.00 | 407 W | 7,509,197 W | 7,333 W | Scale-Up Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | NVLink | — | GB300 | Scale-Up | NG-GB300-CX8-IB-NV-3L | |
| $720.00 | 36,864 | 36.00 | 0.50 | $26,542,080.00 | $25,920.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | — | — | — | GB300 | Scale-Up | NG-GB300-CX8-IB-NV-3L | |
| $576.00 | 36,864 | 36.00 | 0.50 | $21,233,664.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB300 | Scale-Up | NG-GB300-CX8-IB-NV-3L | |
| $288.00 | 36,864 | 36.00 | 0.50 | $10,616,832.00 | $10,368.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB300 | Scale-Up | NG-GB300-CX8-IB-NV-3L | |
| $288.00 | 73,728 | 72.00 | 1.00 | $21,233,664.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB300 | Scale-Up | NG-GB300-CX8-IB-NV-3L | |
| $144.00 | 73,728 | 72.00 | 1.00 | $10,616,832.00 | $10,368.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB300 | Scale-Up | NG-GB300-CX8-IB-NV-3L | |
| $4.00 | 5,308,416 | 5,184.00 | 72.00 | $21,233,664.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB300 | Scale-Up | NG-GB300-CX8-IB-NV-3L | |
| $150.00 | 2,048 | 2.00 | 0.03 | $307,200.00 | $300.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Others | Others | Device Level | — | — | NVLink | — | GB300 | Scale-Up | NG-GB300-CX8-IB-NV-3L | |
Per-server cost: $779,240.00 | |||||||||||||||||||||
| $1,200.00 | 73,728 | 72.00 | 1.00 | $88,473,600.00 | $86,400.00 | 17 W | 1,253,376 W | 1,224 W | Transceiver | Neocloud Giant | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | GB300 | Backend | NG-GB300-CX8-IB-NV-3L | |
| $390.00 | 221,184 | 216.00 | 3.00 | $86,261,760.00 | $84,240.00 | — | — | — | Fiber | Neocloud Giant | Others | — | White Label | — | — | — | — | GB300 | Backend | NG-GB300-CX8-IB-NV-3L | |
| $1,900.00 | 184,320 | 180.00 | 2.50 | $350,208,000.00 | $342,000.00 | 22 W | 4,055,040 W | 3,960 W | Transceiver | Neocloud Giant | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | GB300 | Backend | NG-GB300-CX8-IB-NV-3L | |
| $1,650.00 | 73,728 | 4.00 | 1.00 | $121,651,200.00 | $6,600.00 | 75 W | 5,529,600 W | 300 W | NIC | Neocloud Giant | Nvidia | — | Device Level | — | — | — | — | GB300 | Backend | NG-GB300-CX8-IB-NV-3L | |
| $104,000.00 | 2,560 | 2.50 | 0.03 | $266,240,000.00 | $260,000.00 | 2,800 W | 7,168,000 W | 7,000 W | Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | — | — | GB300 | Backend | NG-GB300-CX8-IB-NV-3L | |
Per-server cost: $164,137.78 | |||||||||||||||||||||
| $55,000.00 | 885 | 0.86 | 0.01 | $48,676,571.41 | $47,535.71 | 950 W | 840,777 W | 821 W | Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | Ethernet | — | GB300 | Frontend | NG-GB300-CX8-IB-NV-3L | |
| $27,000.00 | 4 | 0.00 | 0.00 | $98,742.86 | $96.43 | 630 W | 2,304 W | 2 W | Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | Ethernet | — | GB300 | Frontend | NG-GB300-CX8-IB-NV-3L | |
| $14,600.86 | 132 | 0.13 | 0.00 | $1,922,307.13 | $1,877.25 | 250 W | 32,914 W | 32 W | Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | Ethernet | — | GB300 | Frontend | NG-GB300-CX8-IB-NV-3L | |
| $3,000.00 | 1,083 | 1.06 | 0.01 | $3,247,542.86 | $3,171.43 | 150 W | 162,377 W | 159 W | Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | Ethernet | — | GB300 | Frontend | NG-GB300-CX8-IB-NV-3L | |
| $1,050.00 | 42,814 | 41.81 | 0.58 | $44,954,880.00 | $43,901.25 | 14 W | 599,398 W | 585 W | Transceiver | Neocloud Giant | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 112G | InfiniBand | Fully Retimed | GB300 | Frontend | NG-GB300-CX8-IB-NV-3L | |
| $603.75 | 42,591 | 41.59 | 0.58 | $25,714,368.00 | $25,111.69 | 9 W | 383,320 W | 374 W | Transceiver | Neocloud Giant | Nvidia | Coherent, Innolight, Mellanox | White Label | — | 112G | InfiniBand | Fully Retimed | GB300 | Frontend | NG-GB300-CX8-IB-NV-3L | |
| $136.12 | 18,900 | 18.46 | 0.26 | $2,572,646.80 | $2,512.35 | 3 W | 56,700 W | 55 W | Transceiver | Neocloud Giant | Nvidia | Mellanox, Others | White Label | — | 28G | InfiniBand | Fully Retimed | GB300 | Frontend | NG-GB300-CX8-IB-NV-3L | |
| $630.00 | 58,595 | 57.22 | 0.79 | $36,914,688.00 | $36,049.50 | 0 W | 0 W | 0 W | Fiber | Neocloud Giant | Others | — | White Label | — | — | — | — | GB300 | Frontend | NG-GB300-CX8-IB-NV-3L | |
| $450.00 | 300 | 0.29 | 0.00 | $134,948.57 | $131.79 | 0 W | 0 W | 0 W | Fiber | Neocloud Giant | Others | — | White Label | — | — | — | — | GB300 | Frontend | NG-GB300-CX8-IB-NV-3L | |
| $450.00 | 8,419 | 8.22 | 0.11 | $3,788,434.29 | $3,699.64 | 0 W | 0 W | 0 W | Fiber | Neocloud Giant | Others | — | White Label | — | — | — | — | GB300 | Frontend | NG-GB300-CX8-IB-NV-3L | |
| $1.00 | 51,961 | 50.74 | 0.70 | $51,960.69 | $50.74 | 0 W | 0 W | 0 W | Cable | Neocloud Giant | Amphenol | — | Device Level | — | — | — | — | GB300 | Frontend | NG-GB300-CX8-IB-NV-3L | |
Per-server cost: $4,005.00 | |||||||||||||||||||||
| $1.25 | 36,864 | 36.00 | 0.50 | $46,080.00 | $45.00 | 0 W | 0 W | 0 W | Connector | Neocloud Giant | Amphenol | Amphenol | White Label | — | — | — | — | GB300 | Compute Tray | NG-GB300-CX8-IB-NV-3L | |
| $35.00 | 36,864 | 36.00 | 0.50 | $1,290,240.00 | $1,260.00 | 0 W | 0 W | 0 W | Cable | Neocloud Giant | Amphenol | Amphenol | White Label | — | — | — | — | GB300 | Compute Tray | NG-GB300-CX8-IB-NV-3L | |
| $37.50 | 73,728 | 72.00 | 1.00 | $2,764,800.00 | $2,700.00 | 0 W | 0 W | 0 W | Cable | Neocloud Giant | Amphenol | Amphenol | White Label | — | — | — | — | GB300 | Compute Tray | NG-GB300-CX8-IB-NV-3L | |
| By fabric | |||||||||||||||||||||
| Total Scale-Up | $170,766,336.00 | $166,764.00 | 7,509,197 W | 7,333 W | |||||||||||||||||
| Total Backend | $912,834,560.00 | $779,240.00 | 18,006,016 W | 12,484 W | |||||||||||||||||
| Total Frontend | $168,077,090.60 | $164,137.78 | 2,077,791 W | 2,029 W | |||||||||||||||||
| Total Compute Tray | $4,101,120.00 | $4,005.00 | 0 W | 0 W | |||||||||||||||||
| Grand Total Cluster Networking | $1,255,779,106.60 | $1,114,146.78 | 27,593,004 W | 21,846 W | |||||||||||||||||
| By component | |||||||||||||||||||||
| Total Transceivers | $511,923,494.80 | $499,925.29 | 6,347,835 W | 6,199 W | |||||||||||||||||
| Total Switches | $320,185,164.26 | $312,680.82 | 8,206,373 W | 8,014 W | |||||||||||||||||
| Total Fiber | $127,099,830.86 | $124,120.93 | 0 W | 0 W | |||||||||||||||||
| Total Cables | $4,107,000.69 | $4,010.74 | 0 W | 0 W | |||||||||||||||||
| Total Connectors | $46,080.00 | $45.00 | 0 W | 0 W | |||||||||||||||||
| Total NICs | $121,651,200.00 | $6,600.00 | 5,529,600 W | 300 W | |||||||||||||||||