Live DB — analyst tables
Test
NG-Feynman NVL144-CX10-IB-4R CPO
NG-Feynman NVL144-CX10-IB-4R CPO
Neocloud Giant · Feynman · CX10
Rack type
Kyber NVL144
Cluster / location
Neocloud Giant Kyber NVL144 x800 Q3450 (CPO)
Buyer profile
Neocloud Giant
Networking type
Infiniband
Number of XPUs
93,312
NIC used
CX10
NICs / XPU
4
Scale-out BW / XPU
6.4T
XPU / server
144
Scale-up network
5 rows
Assigned blockDefault
Feynman - Kyber NVL144
Scale-UpXPU: Feynman Kyber NVL1445 linesshared by 11 SKUs
Scale-Up Parts Summary
5
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia NVSwitch 8.0 (NVLink 8) | 23,328 | 36.00 | 0.25 |
| NV Sentry HD 448Gb/s 144DP (Male) | 186,624 | 288.00 | 2.00 |
| NV Sentry HD 448Gb/s 144DP (Female) | 186,624 | 288.00 | 2.00 |
| NVL Blade Column Spine Chassis (NvLink 7) | 1,296 | 2.00 | 0.01 |
| NVL Kyber Canister Midplane PCB (NvLink 7) | 648 | 1.00 | 0.01 |
Backend network
4 rows
Assigned blockDefault
Feynman - Kyber NVL144 - CX10 - 3L - IB - X800-Q3450 CPO - Generic
BackendXPU: Feynman Kyber NVL1444 linesshared by 2 SKUs
Backend Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia LinkX 1.6T DR8 (SiPho) | 93,312 | 144.00 | 1.00 |
| Nvidia LinkX 800G Single Mode | 1,679,616 | 2,592.00 | 18.00 |
| ConnectX-10 NIC - 1.6T | 279,936 | 432.00 | 3.00 |
| Quantum-X800-Q3450 CPO | 19,440 | 30.00 | 0.21 |
Frontend network
11 rows
Assigned blockDefault
Feynman - Kyber NVL144 - SN6600 - Generic
FrontendXPU: Feynman Kyber NVL14411 linesshared by 11 SKUs
Frontend Parts Summary
11
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Spectrum-6 102.4T x1600 (SN6600) | 1,120 | 2 | 0.0120 |
| Spectrum-4 25.6T (SN5400) | 5 | 0 | 0.0001 |
| Spectrum-3 12.8T (SN4700) | 167 | 0 | 0.0018 |
| Spectrum-2 6.4T (SN3700) | 1,370 | 2 | 0.0147 |
| Nvidia LinkX 1.6T DR8 (SiPho) | 54,187 | 84 | 0.5807 |
| Nvidia LinkX 800G DR4 | 53,904 | 83 | 0.5777 |
| Nvidia LinkX 200G SR4 | 23,920 | 37 | 0.2563 |
| Nvidia LinkX 800G Multimode | 74,159 | 114 | 0.7947 |
| Nvidia LinkX 400G Multimode | 380 | 1 | 0.0041 |
| Nvidia LinkX 200G Multimode | 10,655 | 16 | 0.1142 |
| RJ45 Cables | 65,763 | 101 | 0.7048 |
Compute Tray Networking Content
4 rows
Assigned blockDefault
Feynman - Kyber NVL144 - Generic
Compute TrayXPU: Feynman Kyber NVL1444 linesshared by 11 SKUs
Compute Tray Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| NV Paladin Board to Board 32 Pin 4p8c (Male) | 93,312 | 144.00 | 1.00 |
| NV Paladin Board to Board 64 Pin 4p16c (Male) | 373,248 | 576.00 | 4.00 |
| NV Paladin Board to Board 32 Pin 4p8c (Female) | 93,312 | 144.00 | 1.00 |
| NV Paladin Board to Board 64 Pin 4p16c (Female) | 373,248 | 576.00 | 4.00 |
2026 share
RJ45 CablesΣ 100%
%
| Item | Unit Cost | Quantity | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Per-server cost: $1,134,494.43 | |||||||||||||||||||||
| $18,071.43 | 23,328 | 36.00 | 0.25 | $421,570,285.70 | $650,571.43 | 800 W | 18,662,400 W | 28,800 W | Scale-Up Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | NVLink | — | Feynman | Scale-Up | NG-Feynman NVL144-CX10-IB-4R CPO | |
| $864.00 | 186,624 | 288.00 | 2.00 | $161,243,136.00 | $248,832.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 448G | NVLink | — | Feynman | Scale-Up | NG-Feynman NVL144-CX10-IB-4R CPO | |
| $432.00 | 186,624 | 288.00 | 2.00 | $80,621,568.00 | $124,416.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 448G | NVLink | — | Feynman | Scale-Up | NG-Feynman NVL144-CX10-IB-4R CPO | |
| $337.50 | 1,296 | 2.00 | 0.01 | $437,400.00 | $675.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Others | Others | Device Level | — | — | NVLink | — | Feynman | Scale-Up | NG-Feynman NVL144-CX10-IB-4R CPO | |
| $110,000.00 | 648 | 1.00 | 0.01 | $71,280,000.00 | $110,000.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Others | Others | Device Level | — | — | NVLink | — | Feynman | Scale-Up | NG-Feynman NVL144-CX10-IB-4R CPO | |
Per-server cost: $7,865,160.00 | |||||||||||||||||||||
| $1,900.00 | 93,312 | 144.00 | 1.00 | $177,292,800.00 | $273,600.00 | 22 W | 2,052,864 W | 3,168 W | Transceiver | Neocloud Giant | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | Feynman | Backend | NG-Feynman NVL144-CX10-IB-4R CPO | |
| $540.00 | 1,679,616 | 2,592.00 | 18.00 | $906,992,640.00 | $1,399,680.00 | 0 W | 0 W | 0 W | Fiber | Neocloud Giant | Others | — | White Label | — | — | — | — | Feynman | Backend | NG-Feynman NVL144-CX10-IB-4R CPO | |
| $3,850.00 | 279,936 | 12.00 | 3.00 | $1,077,753,600.00 | $46,200.00 | 100 W | 27,993,600 W | 1,200 W | NIC | Neocloud Giant | Nvidia | — | Device Level | — | — | — | — | Feynman | Backend | NG-Feynman NVL144-CX10-IB-4R CPO | |
| $204,856.00 | 19,440 | 30.00 | 0.21 | $3,982,400,640.00 | $6,145,680.00 | 3,548 W | 68,973,120 W | 106,440 W | Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | — | CPO | Feynman | Backend | NG-Feynman NVL144-CX10-IB-4R CPO | |
Per-server cost: $558,495.01 | |||||||||||||||||||||
| $98,000.00 | 1,120 | 1.73 | 0.01 | $109,771,200.03 | $169,400.00 | 1,344 W | 1,504,877 W | 2,322 W | Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | Ethernet | — | Feynman | Frontend | NG-Feynman NVL144-CX10-IB-4R CPO | |
| $16,500.00 | 5 | 0.01 | 0.00 | $76,371.42 | $117.86 | 670 W | 3,101 W | 5 W | Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | Ethernet | — | Feynman | Frontend | NG-Feynman NVL144-CX10-IB-4R CPO | |
| $27,000.00 | 167 | 0.26 | 0.00 | $4,498,971.42 | $6,942.86 | 630 W | 104,976 W | 162 W | Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | Ethernet | — | Feynman | Frontend | NG-Feynman NVL144-CX10-IB-4R CPO | |
| $14,600.86 | 1,370 | 2.11 | 0.01 | $20,004,008.59 | $30,870.38 | 250 W | 342,514 W | 529 W | Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | Ethernet | — | Feynman | Frontend | NG-Feynman NVL144-CX10-IB-4R CPO | |
| $1,900.00 | 54,187 | 83.62 | 0.58 | $102,954,702.86 | $158,880.71 | 22 W | 1,192,107 W | 1,840 W | Transceiver | Neocloud Giant | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | Feynman | Frontend | NG-Feynman NVL144-CX10-IB-4R CPO | |
| $1,200.00 | 53,904 | 83.19 | 0.58 | $64,685,211.43 | $99,822.86 | 17 W | 916,374 W | 1,414 W | Transceiver | Neocloud Giant | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | Feynman | Frontend | NG-Feynman NVL144-CX10-IB-4R CPO | |
| $341.25 | 23,920 | 36.91 | 0.26 | $8,162,856.00 | $12,597.00 | 5 W | 119,602 W | 185 W | Transceiver | Neocloud Giant | Nvidia | Mellanox, Others | White Label | — | 56G | InfiniBand | Fully Retimed | Feynman | Frontend | NG-Feynman NVL144-CX10-IB-4R CPO | |
| $630.00 | 74,159 | 114.44 | 0.79 | $46,720,152.00 | $72,099.00 | 0 W | 0 W | 0 W | Fiber | Neocloud Giant | Others | — | White Label | — | — | — | — | Feynman | Frontend | NG-Feynman NVL144-CX10-IB-4R CPO | |
| $450.00 | 380 | 0.59 | 0.00 | $170,794.29 | $263.57 | 0 W | 0 W | 0 W | Fiber | Neocloud Giant | Others | — | White Label | — | — | — | — | Feynman | Frontend | NG-Feynman NVL144-CX10-IB-4R CPO | |
| $450.00 | 10,655 | 16.44 | 0.11 | $4,794,737.14 | $7,399.29 | 0 W | 0 W | 0 W | Fiber | Neocloud Giant | Others | — | White Label | — | — | — | — | Feynman | Frontend | NG-Feynman NVL144-CX10-IB-4R CPO | |
| $1.00 | 65,763 | 101.49 | 0.70 | $65,762.74 | $101.49 | 0 W | 0 W | 0 W | Cable | Neocloud Giant | Amphenol | — | Device Level | — | — | — | — | Feynman | Frontend | NG-Feynman NVL144-CX10-IB-4R CPO | |
Per-server cost: $124,416.00 | |||||||||||||||||||||
| $64.00 | 93,312 | 144.00 | 1.00 | $5,971,968.00 | $9,216.00 | 0 W | 0 W | 0 W | Midplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Feynman | Compute Tray | NG-Feynman NVL144-CX10-IB-4R CPO | |
| $128.00 | 373,248 | 576.00 | 4.00 | $47,775,744.00 | $73,728.00 | 0 W | 0 W | 0 W | Midplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Feynman | Compute Tray | NG-Feynman NVL144-CX10-IB-4R CPO | |
| $32.00 | 93,312 | 144.00 | 1.00 | $2,985,984.00 | $4,608.00 | 0 W | 0 W | 0 W | Midplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Feynman | Compute Tray | NG-Feynman NVL144-CX10-IB-4R CPO | |
| $64.00 | 373,248 | 576.00 | 4.00 | $23,887,872.00 | $36,864.00 | 0 W | 0 W | 0 W | Midplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Feynman | Compute Tray | NG-Feynman NVL144-CX10-IB-4R CPO | |
| By fabric | |||||||||||||||||||||
| Total Scale-Up | $735,152,389.70 | $1,134,494.43 | 18,662,400 W | 28,800 W | |||||||||||||||||
| Total Backend | $6,144,439,680.00 | $7,865,160.00 | 99,019,584 W | 110,808 W | |||||||||||||||||
| Total Frontend | $361,904,767.92 | $558,495.01 | 4,183,551 W | 6,456 W | |||||||||||||||||
| Total Compute Tray | $80,621,568.00 | $124,416.00 | 0 W | 0 W | |||||||||||||||||
| Grand Total Cluster Networking | $7,322,118,405.62 | $9,682,565.44 | 121,865,535 W | 146,064 W | |||||||||||||||||
| By component | |||||||||||||||||||||
| Total Transceivers | $353,095,570.29 | $544,900.57 | 4,280,947 W | 6,606 W | |||||||||||||||||
| Total Switches | $4,116,751,191.46 | $6,353,011.10 | 70,928,588 W | 109,458 W | |||||||||||||||||
| Total Fiber | $958,678,323.43 | $1,479,441.86 | 0 W | 0 W | |||||||||||||||||
| Total Cables | $65,762.74 | $101.49 | 0 W | 0 W | |||||||||||||||||
| Total Connectors | — | — | — | — | |||||||||||||||||
| Total NICs | $1,077,753,600.00 | $46,200.00 | 27,993,600 W | 1,200 W | |||||||||||||||||