Live DB — analyst tables
Test
Oracle 131072 VR200 CX-9 Hyperscaler Ethernet Cluster Configuration
OCI-VR200-CX9-AR-Eth-3L
Oracle · VR200 · CX-9
Rack type
NVL72
Cluster / location
Oracle VR200 non-Rail 131k Arista Cluster
Buyer profile
Hyperscaler
Networking type
Ethernet
Number of XPUs
131,072
NIC used
CX-9
NICs / XPU
2
Scale-out BW / XPU
1.6T
XPU / server
72
Scale-up network
7 rows
Assigned blockDefault
VR200 - NVL72
Scale-UpXPU: VR200 NVL727 linesshared by 31 SKUs
Scale-Up Parts Summary
7
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia NVSwitch 6.0 (NVLink 6) | 65,536 | 36.00 | 0.50 |
| NV Paladin HD2 224Gb/s 144 Bidi (Male) | 65,536 | 36.00 | 0.50 |
| NV Paladin HD2 224Gb/s 144 Bidi (Female) | 65,536 | 36.00 | 0.50 |
| NV Paladin HD2 224Gb/s 72 Bidi (Male) | 131,072 | 72.00 | 1.00 |
| NV Paladin HD2 224Gb/s 72 Bidi (Female) | 9,437,184 | 5,184.00 | 72.00 |
| NV 224Gb/s SkewClear EXD Gen 2 Bidi Cable | 9,437,184 | 5,184.00 | 72.00 |
| NVL Spine Chassis (NvLink 6) | 3,641 | 2.00 | 0.03 |
Backend network
5 rows
Assigned blockDefault
VR200 - NVL72 - CX9 - 3L - ETH - TH6 - OCI
BackendXPU: VR200 NVL725 linesshared by 1 SKU
Backend Parts Summary
5
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Generic 1.6T AEC | 131,072 | 72.00 | 1.00 |
| ConnectX-9 NIC - 800G | 262,144 | 144.00 | 2.00 |
| Generic 1.6T DR8 (SiPho) | 524,288 | 288.00 | 4.00 |
| Generic 800G Single Mode | 524,288 | 288.00 | 4.00 |
| Arista Tomahawk 6 102.4T | 11,605 | 6.38 | 0.09 |
Frontend network
11 rows
Assigned blockDefault
VR200 - NVL72 - Arista TH6 - OCI
FrontendXPU: VR200 NVL7211 linesshared by 2 SKUs
Frontend Parts Summary
11
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Arista Tomahawk 6 102.4T | 1,573 | 1 | 0.0120 |
| Arista Tomahawk 4 25.6T (7060DX5-64E) | 7 | 0 | 0.0001 |
| Arista Tomahawk 3 12.8T (7050PX4-32S) | 234 | 0 | 0.0018 |
| Arista Tomahawk 2 6.4T (7050CX3-32S) | 1,924 | 1 | 0.0147 |
| Generic 1.6T DR8 (SiPho) | 76,114 | 42 | 0.5807 |
| Generic 800G DR4 | 75,717 | 42 | 0.5777 |
| Generic 200G SR4 | 33,600 | 18 | 0.2563 |
| Generic 800G Single Mode | 104,168 | 57 | 0.7947 |
| Generic 400G Single Mode | 533 | 0 | 0.0041 |
| Generic 200G Multimode | 14,967 | 8 | 0.1142 |
| RJ45 Cables | 92,375 | 51 | 0.7048 |
Compute Tray Networking Content
4 rows
Assigned blockDefault
VR200 - NVL72 - Generic
Compute TrayXPU: VR200 NVL724 linesshared by 31 SKUs
Compute Tray Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| NV Paladin Board to Board 32 Pin 4p8c (Male) | 131,072 | 72.00 | 1.00 |
| NV Paladin Board to Board 64 Pin 4p16c (Male) | 524,288 | 288.00 | 4.00 |
| NV Paladin Board to Board 32 Pin 4p8c (Female) | 131,072 | 72.00 | 1.00 |
| NV Paladin Board to Board 64 Pin 4p16c (Female) | 524,288 | 288.00 | 4.00 |
2026 share
Nvidia NVSwitch 6.0 (NVLink 6)Σ 100%
%
NV Paladin HD2 224Gb/s 144 Bidi (Male)Σ 100%
%
NV Paladin HD2 224Gb/s 144 Bidi (Female)Σ 100%
%
NV Paladin HD2 224Gb/s 72 Bidi (Male)Σ 100%
%
NV Paladin HD2 224Gb/s 72 Bidi (Female)Σ 100%
%
NV 224Gb/s SkewClear EXD Gen 2 Bidi CableΣ 100%
%
| Item | Unit Cost | Quantity | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Per-server cost: $963,522.00 | |||||||||||||||||||||
| $4,000.00 | 65,536 | 36.00 | 0.50 | $262,144,000.00 | $144,000.00 | 650 W | 42,598,400 W | 23,400 W | Scale-Up Switch | Oracle | Nvidia | — | Device Level | — | — | NVLink | — | VR200 | Scale-Up | OCI-VR200-CX9-AR-Eth-3L | |
| $576.00 | 65,536 | 36.00 | 0.50 | $37,748,736.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Oracle | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Scale-Up | OCI-VR200-CX9-AR-Eth-3L | |
| $288.00 | 65,536 | 36.00 | 0.50 | $18,874,368.00 | $10,368.00 | 0 W | 0 W | 0 W | Backplane | Oracle | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Scale-Up | OCI-VR200-CX9-AR-Eth-3L | |
| $288.00 | 131,072 | 72.00 | 1.00 | $37,748,736.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Oracle | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Scale-Up | OCI-VR200-CX9-AR-Eth-3L | |
| $144.00 | 9,437,184 | 5,184.00 | 72.00 | $1,358,954,496.00 | $746,496.00 | 0 W | 0 W | 0 W | Backplane | Oracle | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Scale-Up | OCI-VR200-CX9-AR-Eth-3L | |
| $4.00 | 9,437,184 | 5,184.00 | 72.00 | $37,748,736.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Oracle | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Scale-Up | OCI-VR200-CX9-AR-Eth-3L | |
| $225.00 | 3,641 | 2.00 | 0.03 | $819,200.00 | $450.00 | 0 W | 0 W | 0 W | Backplane | Oracle | Others | Others | Device Level | — | — | NVLink | — | VR200 | Scale-Up | OCI-VR200-CX9-AR-Eth-3L | |
Per-server cost: $675,795.00 | |||||||||||||||||||||
| $550.00 | 131,072 | 72.00 | 1.00 | $72,089,600.00 | $39,600.00 | 32 W | 4,220,518 W | 2,318 W | AEC | Oracle | Astera | — | Device Level | — | 224G | Ethernet | — | VR200 | Backend | OCI-VR200-CX9-AR-Eth-3L | |
| $1,650.00 | 262,144 | 8.00 | 2.00 | $432,537,600.00 | $13,200.00 | 90 W | 23,592,960 W | 720 W | NIC | Oracle | Nvidia | — | Device Level | — | — | — | — | VR200 | Backend | OCI-VR200-CX9-AR-Eth-3L | |
| $810.00 | 524,288 | 288.00 | 4.00 | $424,673,280.00 | $233,280.00 | 22 W | 11,534,336 W | 6,336 W | Transceiver | Oracle | AAOI | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Backend | OCI-VR200-CX9-AR-Eth-3L | |
| $180.00 | 524,288 | 288.00 | 4.00 | $94,371,840.00 | $51,840.00 | 0 W | 0 W | 0 W | Fiber | Oracle | Corning | — | Device Level | — | — | — | — | VR200 | Backend | OCI-VR200-CX9-AR-Eth-3L | |
| $53,000.00 | 11,605 | 6.37 | 0.09 | $615,082,666.65 | $337,875.00 | 1,500 W | 17,408,000 W | 9,562 W | Switch | Oracle | Arista | — | Device Level | — | — | — | — | VR200 | Backend | OCI-VR200-CX9-AR-Eth-3L | |
Per-server cost: $134,355.49 | |||||||||||||||||||||
| $53,000.00 | 1,573 | 0.86 | 0.01 | $83,389,358.73 | $45,807.14 | 1,500 W | 2,360,076 W | 1,296 W | Switch | Oracle | Arista | — | Device Level | — | — | — | — | VR200 | Frontend | OCI-VR200-CX9-AR-Eth-3L | |
| $19,000.00 | 7 | 0.00 | 0.00 | $123,530.15 | $67.86 | 850 W | 5,526 W | 3 W | Switch | Oracle | Arista | — | Device Level | — | — | — | — | VR200 | Frontend | OCI-VR200-CX9-AR-Eth-3L | |
| $15,000.00 | 234 | 0.13 | 0.00 | $3,510,857.15 | $1,928.57 | 630 W | 147,456 W | 81 W | Switch | Oracle | Arista | — | Device Level | — | — | — | — | VR200 | Frontend | OCI-VR200-CX9-AR-Eth-3L | |
| $11,000.00 | 1,924 | 1.06 | 0.01 | $21,169,168.25 | $11,628.57 | 250 W | 481,117 W | 264 W | Switch | Oracle | Arista | — | Device Level | — | — | — | — | VR200 | Frontend | OCI-VR200-CX9-AR-Eth-3L | |
| $810.00 | 76,114 | 41.81 | 0.58 | $61,652,406.86 | $33,866.68 | 22 W | 1,674,510 W | 920 W | Transceiver | Oracle | AAOI | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Frontend | OCI-VR200-CX9-AR-Eth-3L | |
| $650.00 | 75,717 | 41.59 | 0.58 | $49,216,365.71 | $27,035.36 | 17 W | 1,287,197 W | 707 W | Transceiver | Oracle | AAOI | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Frontend | OCI-VR200-CX9-AR-Eth-3L | |
| $130.00 | 33,600 | 18.46 | 0.26 | $4,368,026.41 | $2,399.43 | 5 W | 168,001 W | 92 W | Transceiver | Oracle | AAOI | — | Device Level | — | 56G | Ethernet | Fully Retimed | VR200 | Frontend | OCI-VR200-CX9-AR-Eth-3L | |
| $180.00 | 104,168 | 57.22 | 0.79 | $18,750,317.71 | $10,299.86 | 0 W | 0 W | 0 W | Fiber | Oracle | Corning | — | Device Level | — | — | — | — | VR200 | Frontend | OCI-VR200-CX9-AR-Eth-3L | |
| $130.00 | 533 | 0.29 | 0.00 | $69,306.92 | $38.07 | 0 W | 0 W | 0 W | Fiber | Oracle | Amphenol | — | Device Level | — | — | — | — | VR200 | Frontend | OCI-VR200-CX9-AR-Eth-3L | |
| $150.00 | 14,967 | 8.22 | 0.11 | $2,244,998.10 | $1,233.21 | 0 W | 0 W | 0 W | Fiber | Oracle | Corning | — | Device Level | — | — | — | — | VR200 | Frontend | OCI-VR200-CX9-AR-Eth-3L | |
| $1.00 | 92,375 | 50.74 | 0.70 | $92,374.55 | $50.74 | 0 W | 0 W | 0 W | Cable | Oracle | Amphenol | — | Device Level | — | — | — | — | VR200 | Frontend | OCI-VR200-CX9-AR-Eth-3L | |
Per-server cost: $62,208.00 | |||||||||||||||||||||
| $64.00 | 131,072 | 72.00 | 1.00 | $8,388,608.00 | $4,608.00 | 0 W | 0 W | 0 W | Midplane | Oracle | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Compute Tray | OCI-VR200-CX9-AR-Eth-3L | |
| $128.00 | 524,288 | 288.00 | 4.00 | $67,108,864.00 | $36,864.00 | 0 W | 0 W | 0 W | Midplane | Oracle | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Compute Tray | OCI-VR200-CX9-AR-Eth-3L | |
| $32.00 | 131,072 | 72.00 | 1.00 | $4,194,304.00 | $2,304.00 | 0 W | 0 W | 0 W | Midplane | Oracle | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Compute Tray | OCI-VR200-CX9-AR-Eth-3L | |
| $64.00 | 524,288 | 288.00 | 4.00 | $33,554,432.00 | $18,432.00 | 0 W | 0 W | 0 W | Midplane | Oracle | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Compute Tray | OCI-VR200-CX9-AR-Eth-3L | |
| By fabric | |||||||||||||||||||||
| Total Scale-Up | $1,754,038,272.00 | $963,522.00 | 42,598,400 W | 23,400 W | |||||||||||||||||
| Total Backend | $1,638,754,986.65 | $675,795.00 | 56,755,814 W | 18,937 W | |||||||||||||||||
| Total Frontend | $244,586,710.55 | $134,355.49 | 6,123,884 W | 3,364 W | |||||||||||||||||
| Total Compute Tray | $113,246,208.00 | $62,208.00 | 0 W | 0 W | |||||||||||||||||
| Grand Total Cluster Networking | $3,750,626,177.20 | $1,835,880.49 | 105,478,098 W | 45,701 W | |||||||||||||||||
| By component | |||||||||||||||||||||
| Total Transceivers | $539,910,078.98 | $296,581.46 | 14,664,044 W | 8,055 W | |||||||||||||||||
| Total Switches | $723,275,580.93 | $397,307.14 | 20,402,176 W | 11,207 W | |||||||||||||||||
| Total Fiber | $115,436,462.73 | $63,411.14 | 0 W | 0 W | |||||||||||||||||
| Total Cables | $92,374.55 | $50.74 | 0 W | 0 W | |||||||||||||||||
| Total Connectors | — | — | — | — | |||||||||||||||||
| Total NICs | $432,537,600.00 | $13,200.00 | 23,592,960 W | 720 W | |||||||||||||||||