Live DB — analyst tables
Test
Oracle 131072 GB200 NVL72 CX-8 Hyperscaler Ethernet Cluster Configuration
OCI-GB200 NVL72-CX8-SX5-8P-2L
Oracle · GB200 · CX-8
Rack type
NVL72
Cluster / location
2-Tier GB200 SX
Buyer profile
Hyperscaler
Networking type
Ethernet
Number of XPUs
131,072
NIC used
CX-8
NICs / XPU
1
Scale-out BW / XPU
800G
XPU / server
72
Scale-up network
8 rows
Assigned blockDefault
GB200 - NVL72
Scale-UpXPU: GB200 NVL728 linesshared by 10 SKUs
Scale-Up Parts Summary
8
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia NVSwitch 5.0 (NVLink 5) | 32,768 | 18.00 | 0.25 |
| NV 2 UltraPass OverPass 144 DP 224Gb/s | 65,536 | 36.00 | 0.50 |
| NV Paladin HD2 224Gb/s 144 DP (Male) | 65,536 | 36.00 | 0.50 |
| NV Paladin HD2 224Gb/s 144 DP (Female) | 65,536 | 36.00 | 0.50 |
| NV Paladin HD2 224Gb/s 72 DP (Male) | 131,072 | 72.00 | 1.00 |
| NV Paladin HD2 224Gb/s 72 DP (Female) | 131,072 | 72.00 | 1.00 |
| NV 224Gb/s SkewClear EXD Gen 2 Cable | 9,437,184 | 5,184.00 | 72.00 |
| NVL Spine Chassis (NvLink 5) | 3,641 | 2.00 | 0.03 |
Backend network
5 rows
Assigned blockDefault
GB200 - NVL72 - CX8 - 2L - ETH - Spectrum-5 - OCI
BackendXPU: GB200 NVL725 linesshared by 1 SKU
Backend Parts Summary
5
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Credo 800G ZF Optics | 262,144 | 144.00 | 2.00 |
| Generic 800G Single Mode | 262,144 | 144.00 | 2.00 |
| Generic 800G DR8 | 262,144 | 144.00 | 2.00 |
| ConnectX-8 NIC - 800G | 131,072 | 72.00 | 1.00 |
| Spectrum-5 51.2T (SN56XX) 512 Radix | 6,144 | 3.38 | 0.05 |
Frontend network
11 rows
Assigned blockDefault
GB200 - NVL72 - SN5600 - Generic
FrontendXPU: GB200 NVL7211 linesshared by 5 SKUs
Frontend Parts Summary
11
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Spectrum-4 51.2T (SN5600) | 1,893 | 1 | 0.0144 |
| Spectrum-3 12.8T (SN4700) | 8 | 0 | 0.0001 |
| Spectrum-2 6.4T (SN3700) | 282 | 0 | 0.0021 |
| Spectrum-2 1GbE (SN2201) | 2,315 | 1 | 0.0177 |
| Nvidia LinkX 800G SR8 | 91,575 | 50 | 0.6987 |
| Nvidia LinkX 400G SR4 | 91,098 | 50 | 0.6950 |
| Nvidia LinkX 100G SR4 QSFP28 | 40,425 | 22 | 0.3084 |
| Nvidia LinkX 800G Multimode | 125,328 | 69 | 0.9562 |
| Nvidia LinkX 400G Multimode | 641 | 0 | 0.0049 |
| Nvidia LinkX 100G Multimode | 18,007 | 10 | 0.1374 |
| RJ45 Cables | 111,138 | 61 | 0.8479 |
Compute Tray Networking Content
3 rows
Assigned blockDefault
GB200 - NVL72 - Generic
Compute TrayXPU: GB200 NVL723 linesshared by 10 SKUs
Compute Tray Parts Summary
3
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| NV MCIO PCIe x16 Connector | 65,536 | 36.00 | 0.50 |
| NV MCIO PCIe x16 Cable | 65,536 | 36.00 | 0.50 |
| NV DensiLink OverPass to OSFP Cage | 131,072 | 72.00 | 1.00 |
2026 share
Nvidia NVSwitch 5.0 (NVLink 5)Σ 100%
%
NV 2 UltraPass OverPass 144 DP 224Gb/sΣ 100%
%
NV Paladin HD2 224Gb/s 144 DP (Male)Σ 100%
%
NV Paladin HD2 224Gb/s 144 DP (Female)Σ 100%
%
NV Paladin HD2 224Gb/s 72 DP (Male)Σ 100%
%
NV Paladin HD2 224Gb/s 72 DP (Female)Σ 100%
%
NV 224Gb/s SkewClear EXD Gen 2 CableΣ 100%
%
NVL Spine Chassis (NvLink 5)Σ 100%
%
| Item | Unit Cost | Quantity | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Per-server cost: $166,764.00 | |||||||||||||||||||||
| $3,200.00 | 32,768 | 18.00 | 0.25 | $104,857,600.00 | $57,600.00 | 407 W | 13,349,683 W | 7,333 W | Scale-Up Switch | Oracle | Nvidia | — | Device Level | — | — | NVLink | — | GB200 | Scale-Up | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
| $720.00 | 65,536 | 36.00 | 0.50 | $47,185,920.00 | $25,920.00 | 0 W | 0 W | 0 W | Backplane | Oracle | Nvidia | Amphenol | White Label | — | — | — | — | GB200 | Scale-Up | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
| $576.00 | 65,536 | 36.00 | 0.50 | $37,748,736.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Oracle | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB200 | Scale-Up | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
| $288.00 | 65,536 | 36.00 | 0.50 | $18,874,368.00 | $10,368.00 | 0 W | 0 W | 0 W | Backplane | Oracle | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB200 | Scale-Up | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
| $288.00 | 131,072 | 72.00 | 1.00 | $37,748,736.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Oracle | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB200 | Scale-Up | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
| $144.00 | 131,072 | 72.00 | 1.00 | $18,874,368.00 | $10,368.00 | 0 W | 0 W | 0 W | Backplane | Oracle | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB200 | Scale-Up | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
| $4.00 | 9,437,184 | 5,184.00 | 72.00 | $37,748,736.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Oracle | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB200 | Scale-Up | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
| $150.00 | 3,641 | 2.00 | 0.03 | $546,133.33 | $300.00 | 0 W | 0 W | 0 W | Backplane | Oracle | Others | Others | Device Level | — | — | NVLink | — | GB200 | Scale-Up | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
Per-server cost: $272,535.00 | |||||||||||||||||||||
| $585.00 | 262,144 | 144.00 | 2.00 | $153,354,240.00 | $84,240.00 | 15 W | 3,932,160 W | 2,160 W | Transceiver | Oracle | Credo | — | Device Level | — | — | Ethernet | Fully Retimed | GB200 | Backend | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
| $180.00 | 262,144 | 144.00 | 2.00 | $47,185,920.00 | $25,920.00 | 0 W | 0 W | 0 W | Fiber | Oracle | Corning | — | Device Level | — | — | — | — | GB200 | Backend | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
| $500.00 | 262,144 | 144.00 | 2.00 | $131,072,000.00 | $72,000.00 | 16 W | 4,194,304 W | 2,304 W | Transceiver | Oracle | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | GB200 | Backend | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
| $1,500.00 | 131,072 | 4.00 | 1.00 | $196,608,000.00 | $6,000.00 | 75 W | 9,830,400 W | 300 W | NIC | Oracle | Nvidia | — | Device Level | — | — | — | — | GB200 | Backend | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
| $25,000.00 | 6,144 | 3.38 | 0.05 | $153,600,000.00 | $84,375.00 | 950 W | 5,836,800 W | 3,206 W | Switch | Oracle | Nvidia | — | Device Level | — | — | Ethernet | — | GB200 | Backend | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
Per-server cost: $122,577.84 | |||||||||||||||||||||
| $23,000.00 | 1,573 | 0.86 | 0.01 | $36,187,834.92 | $19,878.57 | 950 W | 1,494,715 W | 821 W | Switch | Oracle | Nvidia | — | Device Level | — | — | Ethernet | — | GB200 | Frontend | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
| $21,600.00 | 7 | 0.00 | 0.00 | $140,434.28 | $77.14 | 630 W | 4,096 W | 2 W | Switch | Oracle | Nvidia | — | Device Level | — | — | Ethernet | — | GB200 | Frontend | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
| $13,273.51 | 234 | 0.13 | 0.00 | $3,106,759.00 | $1,706.59 | 250 W | 58,514 W | 32 W | Switch | Oracle | Nvidia | — | Device Level | — | — | Ethernet | — | GB200 | Frontend | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
| $2,400.00 | 1,924 | 1.06 | 0.01 | $4,618,727.62 | $2,537.14 | 150 W | 288,670 W | 159 W | Switch | Oracle | Nvidia | — | Device Level | — | — | Ethernet | — | GB200 | Frontend | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
| $930.23 | 76,114 | 41.81 | 0.58 | $70,803,797.70 | $38,893.69 | 14 W | 1,065,597 W | 585 W | Transceiver | Oracle | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 112G | InfiniBand | Fully Retimed | GB200 | Frontend | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
| $575.00 | 75,717 | 41.59 | 0.58 | $43,537,554.29 | $23,915.89 | 9 W | 681,457 W | 374 W | Transceiver | Oracle | Nvidia | Coherent, Innolight, Mellanox | White Label | — | 112G | InfiniBand | Fully Retimed | GB200 | Frontend | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
| $123.74 | 33,600 | 18.46 | 0.26 | $4,157,813.02 | $2,283.95 | 3 W | 100,801 W | 55 W | Transceiver | Oracle | Nvidia | Mellanox, Others | White Label | — | 28G | InfiniBand | Fully Retimed | GB200 | Frontend | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
| $525.00 | 104,168 | 57.22 | 0.79 | $54,688,426.67 | $30,041.25 | 0 W | 0 W | 0 W | Fiber | Oracle | Others | — | White Label | — | — | — | — | GB200 | Frontend | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
| $375.00 | 533 | 0.29 | 0.00 | $199,923.81 | $109.82 | 0 W | 0 W | 0 W | Fiber | Oracle | Others | — | White Label | — | — | — | — | GB200 | Frontend | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
| $375.00 | 14,967 | 8.22 | 0.11 | $5,612,495.24 | $3,083.04 | 0 W | 0 W | 0 W | Fiber | Oracle | Others | — | White Label | — | — | — | — | GB200 | Frontend | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
| $1.00 | 92,375 | 50.74 | 0.70 | $92,374.55 | $50.74 | 0 W | 0 W | 0 W | Cable | Oracle | Amphenol | — | Device Level | — | — | — | — | GB200 | Frontend | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
Per-server cost: $4,005.00 | |||||||||||||||||||||
| $1.25 | 65,536 | 36.00 | 0.50 | $81,920.00 | $45.00 | 0 W | 0 W | 0 W | Connector | Oracle | Amphenol | Amphenol | White Label | — | — | — | — | GB200 | Compute Tray | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
| $35.00 | 65,536 | 36.00 | 0.50 | $2,293,760.00 | $1,260.00 | 0 W | 0 W | 0 W | Cable | Oracle | Amphenol | Amphenol | White Label | — | — | — | — | GB200 | Compute Tray | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
| $37.50 | 131,072 | 72.00 | 1.00 | $4,915,200.00 | $2,700.00 | 0 W | 0 W | 0 W | Cable | Oracle | Amphenol | Amphenol | White Label | — | — | — | — | GB200 | Compute Tray | OCI-GB200 NVL72-CX8-SX5-8P-2L | |
| By fabric | |||||||||||||||||||||
| Total Scale-Up | $303,584,597.33 | $166,764.00 | 13,349,683 W | 7,333 W | |||||||||||||||||
| Total Backend | $681,820,160.00 | $272,535.00 | 23,793,664 W | 7,970 W | |||||||||||||||||
| Total Frontend | $223,146,141.10 | $122,577.84 | 3,693,851 W | 2,029 W | |||||||||||||||||
| Total Compute Tray | $7,290,880.00 | $4,005.00 | 0 W | 0 W | |||||||||||||||||
| Grand Total Cluster Networking | $1,215,841,778.43 | $565,881.84 | 40,837,198 W | 17,333 W | |||||||||||||||||
| By component | |||||||||||||||||||||
| Total Transceivers | $402,925,405.01 | $221,333.54 | 9,974,319 W | 5,479 W | |||||||||||||||||
| Total Switches | $197,653,755.82 | $108,574.45 | 7,682,796 W | 4,220 W | |||||||||||||||||
| Total Fiber | $107,686,765.71 | $59,154.11 | 0 W | 0 W | |||||||||||||||||
| Total Cables | $7,301,334.55 | $4,010.74 | 0 W | 0 W | |||||||||||||||||
| Total Connectors | $81,920.00 | $45.00 | 0 W | 0 W | |||||||||||||||||
| Total NICs | $196,608,000.00 | $6,000.00 | 9,830,400 W | 300 W | |||||||||||||||||