Live DB — analyst tables
Test
Default Hyperscaler 93312 Rubin Ultra NVL576 CX-9 Hyperscaler Spectrum X Cluster Configuration
HS-RU NVL576-CX9-IB-4R CPO
Default Hyperscaler · Rubin Ultra · CX-9
Rack type
NVL576
Cluster / location
Default Rubin Ultra
Buyer profile
Hyperscaler
Networking type
Spectrum X
Number of XPUs
93,312
NIC used
CX-9
NICs / XPU
4
Scale-out BW / XPU
3.2T
XPU / server
576
Scale-up network
8 rows
Assigned blockDefault
Rubin Ultra - NVL576
Scale-UpXPU: Rubin Ultra NVL5768 linesshared by 11 SKUs
Scale-Up Parts Summary
8
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia NVSwitch 7.0 (NVLink 7) - 28.8T | 139,968 | 864.00 | 1.50 |
| NV 3.2T Optical Engine (OE) for NVLink Switch side CPO | 1,679,616 | 10,368.00 | 18.00 |
| NV 1.6T 8 Fiber Pair FAU | 1,679,616 | 10,368.00 | 18.00 |
| NV External Laser Source (ELS) 8 LD 6.4T for NVLink CPO Switch | 419,904 | 2,592.00 | 4.50 |
| NV Sentry HD 448Gb/s 72DP (Male) | 186,624 | 1,152.00 | 2.00 |
| NV Sentry HD 448Gb/s 72DP (Female) | 186,624 | 1,152.00 | 2.00 |
| NVL Blade Column Spine Chassis (NvLink 7) | 6,718,464 | 41,472.00 | 72.00 |
| NV 224Gb/s SkewClear EXD Gen 2 Bidi Cable | 6,718,464 | 41,472.00 | 72.00 |
Backend network
4 rows
Assigned blockDefault
Rubin Ultra - NVL576 - CX9 - 3L - IB - X800-Q3450 CPO - Generic
BackendXPU: Rubin Ultra NVL5764 linesshared by 2 SKUs
Backend Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia LinkX 1.6T DR8 (SiPho) | 93,312 | 576.00 | 1.00 |
| Nvidia LinkX 800G Single Mode | 559,872 | 3,456.00 | 6.00 |
| ConnectX-9 NIC - 800G | 373,248 | 2,304.00 | 4.00 |
| Quantum-X800-Q3450 CPO | 12,960 | 80.00 | 0.14 |
Frontend network
11 rows
Assigned blockDefault
Rubin Ultra - NVL576 - SN6600 - Generic
FrontendXPU: Rubin Ultra NVL57611 linesshared by 11 SKUs
Frontend Parts Summary
11
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Spectrum-6 102.4T x1600 (SN6600) | 1,120 | 7 | 0.0120 |
| Spectrum-4 25.6T (SN5400) | 5 | 0 | 0.0001 |
| Spectrum-3 12.8T (SN4700) | 167 | 1 | 0.0018 |
| Spectrum-2 6.4T (SN3700) | 1,370 | 8 | 0.0147 |
| Nvidia LinkX 1.6T DR8 (SiPho) | 54,187 | 334 | 0.5807 |
| Nvidia LinkX 800G DR4 | 53,904 | 333 | 0.5777 |
| Nvidia LinkX 200G SR4 | 23,920 | 148 | 0.2563 |
| Nvidia LinkX 800G Multimode | 74,159 | 458 | 0.7947 |
| Nvidia LinkX 400G Multimode | 380 | 2 | 0.0041 |
| Nvidia LinkX 200G Multimode | 10,655 | 66 | 0.1142 |
| RJ45 Cables | 65,763 | 406 | 0.7048 |
Compute Tray Networking Content
4 rows
Assigned blockDefault
Rubin Ultra - NVL576 - Generic
Compute TrayXPU: Rubin Ultra NVL5764 linesshared by 11 SKUs
Compute Tray Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| NV Paladin Board to Board 32 Pin 4p8c (Male) | 93,312 | 576.00 | 1.00 |
| NV Paladin Board to Board 64 Pin 4p16c (Male) | 373,248 | 2,304.00 | 4.00 |
| NV Paladin Board to Board 32 Pin 4p8c (Female) | 93,312 | 576.00 | 1.00 |
| NV Paladin Board to Board 64 Pin 4p16c (Female) | 373,248 | 2,304.00 | 4.00 |
2026 share
Nvidia NVSwitch 7.0 (NVLink 7) - 28.8TΣ 100%
%
NV 3.2T Optical Engine (OE) for NVLink Switch side CPOΣ 100%
%
NV 1.6T 8 Fiber Pair FAUΣ 100%
%
NV External Laser Source (ELS) 8 LD 6.4T for NVLink CPO SwitchΣ 100%
%
NV Sentry HD 448Gb/s 72DP (Male)Σ 100%
%
NV Sentry HD 448Gb/s 72DP (Female)Σ 100%
%
NVL Blade Column Spine Chassis (NvLink 7)Σ 100%
%
NV 224Gb/s SkewClear EXD Gen 2 Bidi CableΣ 100%
%
| Item | Unit Cost | Quantity | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Per-server cost: $27,281,664.00 | |||||||||||||||||||||
| $4,000.00 | 139,968 | 864.00 | 1.50 | $559,872,000.00 | $3,456,000.00 | 800 W | 111,974,400 W | 691,200 W | Scale-Up Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | NVLink | — | Rubin Ultra | Scale-Up | HS-RU NVL576-CX9-IB-4R CPO | |
| $400.00 | 1,679,616 | 10,368.00 | 18.00 | $671,846,400.00 | $4,147,200.00 | 13 W | 21,163,162 W | 130,637 W | — | Default Hyperscaler | Others | Others | White Label | — | — | NVLink | — | Rubin Ultra | Scale-Up | HS-RU NVL576-CX9-IB-4R CPO | |
| $160.00 | 1,679,616 | 10,368.00 | 18.00 | $268,738,560.00 | $1,658,880.00 | 0 W | 0 W | 0 W | — | Default Hyperscaler | Others | Others | White Label | — | — | NVLink | — | Rubin Ultra | Scale-Up | HS-RU NVL576-CX9-IB-4R CPO | |
| $1,200.00 | 419,904 | 2,592.00 | 4.50 | $503,884,800.00 | $3,110,400.00 | 8 W | 3,359,232 W | 20,736 W | — | Default Hyperscaler | Others | Others | White Label | — | — | NVLink | — | Rubin Ultra | Scale-Up | HS-RU NVL576-CX9-IB-4R CPO | |
| $432.00 | 186,624 | 1,152.00 | 2.00 | $80,621,568.00 | $497,664.00 | 0 W | 0 W | 0 W | Backplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 448G | NVLink | — | Rubin Ultra | Scale-Up | HS-RU NVL576-CX9-IB-4R CPO | |
| $216.00 | 186,624 | 1,152.00 | 2.00 | $40,310,784.00 | $248,832.00 | 0 W | 0 W | 0 W | Backplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 448G | NVLink | — | Rubin Ultra | Scale-Up | HS-RU NVL576-CX9-IB-4R CPO | |
| $337.50 | 6,718,464 | 41,472.00 | 72.00 | $2,267,481,600.00 | $13,996,800.00 | 0 W | 0 W | 0 W | Backplane | Default Hyperscaler | Others | Others | Device Level | — | — | NVLink | — | Rubin Ultra | Scale-Up | HS-RU NVL576-CX9-IB-4R CPO | |
| $4.00 | 6,718,464 | 41,472.00 | 72.00 | $26,873,856.00 | $165,888.00 | 0 W | 0 W | 0 W | Backplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Rubin Ultra | Scale-Up | HS-RU NVL576-CX9-IB-4R CPO | |
Per-server cost: $15,685,064.85 | |||||||||||||||||||||
| $1,723.40 | 93,312 | 576.00 | 1.00 | $160,814,297.84 | $992,680.85 | 22 W | 2,052,864 W | 12,672 W | Transceiver | Default Hyperscaler | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | Rubin Ultra | Backend | HS-RU NVL576-CX9-IB-4R CPO | |
| $450.00 | 559,872 | 3,456.00 | 6.00 | $251,942,400.00 | $1,555,200.00 | 0 W | 0 W | 0 W | Fiber | Default Hyperscaler | Others | — | White Label | — | — | — | — | Rubin Ultra | Backend | HS-RU NVL576-CX9-IB-4R CPO | |
| $1,650.00 | 373,248 | 16.00 | 4.00 | $615,859,200.00 | $26,400.00 | 90 W | 33,592,320 W | 1,440 W | NIC | Default Hyperscaler | Nvidia | — | Device Level | — | — | — | — | Rubin Ultra | Backend | HS-RU NVL576-CX9-IB-4R CPO | |
| $163,884.80 | 12,960 | 80.00 | 0.14 | $2,123,947,008.00 | $13,110,784.00 | 3,548 W | 45,982,080 W | 283,840 W | Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | — | CPO | Rubin Ultra | Backend | HS-RU NVL576-CX9-IB-4R CPO | |
Per-server cost: $1,753,506.88 | |||||||||||||||||||||
| $32,526.91 | 1,120 | 6.91 | 0.01 | $36,433,858.74 | $224,900.36 | 1,344 W | 1,504,877 W | 9,289 W | Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | Ethernet | — | Rubin Ultra | Frontend | HS-RU NVL576-CX9-IB-4R CPO | |
| $15,000.00 | 5 | 0.03 | 0.00 | $69,428.57 | $428.57 | 670 W | 3,101 W | 19 W | Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | Ethernet | — | Rubin Ultra | Frontend | HS-RU NVL576-CX9-IB-4R CPO | |
| $21,600.00 | 167 | 1.03 | 0.00 | $3,599,177.13 | $22,217.14 | 630 W | 104,976 W | 648 W | Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | Ethernet | — | Rubin Ultra | Frontend | HS-RU NVL576-CX9-IB-4R CPO | |
| $13,273.51 | 1,370 | 8.46 | 0.01 | $18,185,462.36 | $112,255.94 | 250 W | 342,514 W | 2,114 W | Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | Ethernet | — | Rubin Ultra | Frontend | HS-RU NVL576-CX9-IB-4R CPO | |
| $1,723.40 | 54,187 | 334.49 | 0.58 | $93,385,564.72 | $576,454.10 | 22 W | 1,192,107 W | 7,359 W | Transceiver | Default Hyperscaler | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | Rubin Ultra | Frontend | HS-RU NVL576-CX9-IB-4R CPO | |
| $1,511.63 | 53,904 | 332.74 | 0.58 | $81,483,308.97 | $502,983.39 | 17 W | 916,374 W | 5,657 W | Transceiver | Default Hyperscaler | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | Rubin Ultra | Frontend | HS-RU NVL576-CX9-IB-4R CPO | |
| $325.00 | 23,920 | 147.66 | 0.26 | $7,774,148.57 | $47,988.57 | 5 W | 119,602 W | 738 W | Transceiver | Default Hyperscaler | Nvidia | Mellanox, Others | White Label | — | 56G | InfiniBand | Fully Retimed | Rubin Ultra | Frontend | HS-RU NVL576-CX9-IB-4R CPO | |
| $525.00 | 74,159 | 457.77 | 0.79 | $38,933,460.00 | $240,330.00 | 0 W | 0 W | 0 W | Fiber | Default Hyperscaler | Others | — | White Label | — | — | — | — | Rubin Ultra | Frontend | HS-RU NVL576-CX9-IB-4R CPO | |
| $375.00 | 380 | 2.34 | 0.00 | $142,328.57 | $878.57 | 0 W | 0 W | 0 W | Fiber | Default Hyperscaler | Others | — | White Label | — | — | — | — | Rubin Ultra | Frontend | HS-RU NVL576-CX9-IB-4R CPO | |
| $375.00 | 10,655 | 65.77 | 0.11 | $3,995,614.29 | $24,664.29 | 0 W | 0 W | 0 W | Fiber | Default Hyperscaler | Others | — | White Label | — | — | — | — | Rubin Ultra | Frontend | HS-RU NVL576-CX9-IB-4R CPO | |
| $1.00 | 65,763 | 405.94 | 0.70 | $65,762.74 | $405.94 | 0 W | 0 W | 0 W | Cable | Default Hyperscaler | Amphenol | — | Device Level | — | — | — | — | Rubin Ultra | Frontend | HS-RU NVL576-CX9-IB-4R CPO | |
Per-server cost: $497,664.00 | |||||||||||||||||||||
| $64.00 | 93,312 | 576.00 | 1.00 | $5,971,968.00 | $36,864.00 | 0 W | 0 W | 0 W | Midplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Rubin Ultra | Compute Tray | HS-RU NVL576-CX9-IB-4R CPO | |
| $128.00 | 373,248 | 2,304.00 | 4.00 | $47,775,744.00 | $294,912.00 | 0 W | 0 W | 0 W | Midplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Rubin Ultra | Compute Tray | HS-RU NVL576-CX9-IB-4R CPO | |
| $32.00 | 93,312 | 576.00 | 1.00 | $2,985,984.00 | $18,432.00 | 0 W | 0 W | 0 W | Midplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Rubin Ultra | Compute Tray | HS-RU NVL576-CX9-IB-4R CPO | |
| $64.00 | 373,248 | 2,304.00 | 4.00 | $23,887,872.00 | $147,456.00 | 0 W | 0 W | 0 W | Midplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Rubin Ultra | Compute Tray | HS-RU NVL576-CX9-IB-4R CPO | |
| By fabric | |||||||||||||||||||||
| Total Scale-Up | $4,419,629,568.00 | $27,281,664.00 | 136,496,794 W | 842,573 W | |||||||||||||||||
| Total Backend | $3,152,562,905.84 | $15,685,064.85 | 81,627,264 W | 297,952 W | |||||||||||||||||
| Total Frontend | $284,068,114.66 | $1,753,506.88 | 4,183,551 W | 25,824 W | |||||||||||||||||
| Total Compute Tray | $80,621,568.00 | $497,664.00 | 0 W | 0 W | |||||||||||||||||
| Grand Total Cluster Networking | $7,936,882,156.50 | $45,217,899.73 | 222,307,609 W | 1,166,349 W | |||||||||||||||||
| By component | |||||||||||||||||||||
| Total Transceivers | $343,457,320.11 | $2,120,106.91 | 4,280,947 W | 26,426 W | |||||||||||||||||
| Total Switches | $2,182,234,934.79 | $13,470,586.02 | 47,937,548 W | 295,911 W | |||||||||||||||||
| Total Fiber | $295,013,802.86 | $1,821,072.86 | 0 W | 0 W | |||||||||||||||||
| Total Cables | $65,762.74 | $405.94 | 0 W | 0 W | |||||||||||||||||
| Total Connectors | — | — | — | — | |||||||||||||||||
| Total NICs | $615,859,200.00 | $26,400.00 | 33,592,320 W | 1,440 W | |||||||||||||||||