Live DB — analyst tables
Test
Amazon 131072 Teton3 Max Nitro-v6 Hyperscaler EFA Cluster Configuration
AWS-Teton3 MAX-Nv6-EFA-WB-320L
Amazon · Trainium3 · Nitro-v6
Rack type
Teton3 Max
Cluster / location
Teton3 Max Clusters
Buyer profile
Hyperscaler
Networking type
EFA
Number of XPUs
131,072
NIC used
Nitro-v6
NICs / XPU
1
Scale-out BW / XPU
400G
XPU / server
144
Scale-up network
9 rows
Assigned blockDefault
Trainium3 - Teton3 Max - AWS - 3
Scale-UpXPU: Trainium3 Teton3 Max9 linesshared by 1 SKU
Scale-Up Parts Summary
9
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Astera Labs Scorpio X 320-lane PCIe Gen 6.0 | 36,409 | 40.00 | 0.28 |
| Astera Labs Scorpio-P 32-Lane PCIe Gen 6.0 | 262,144 | 288.00 | 2.00 |
| Paladin HD 112Gb/s 320 DP (Male) | 72,818 | 80.00 | 0.56 |
| Paladin HD 112Gb/s 320 DP (Female) | 72,818 | 80.00 | 0.56 |
| 112Gb/s SkewClear EXD Cable | 23,301,689 | 25,600.00 | 177.78 |
| Strada Whisper 112Gb/s 80 DP Absolute Connector (Male) | 262,144 | 288.00 | 2.00 |
| Strada Whisper 112Gb/s 80 DP Absolute Connector (Female) | 262,144 | 288.00 | 2.00 |
| Generic PCIe Gen6 x16 (128Gb/s uni-di) 2-meter AEC | 65,536 | 72.00 | 0.50 |
| Teton3 Backplane Chassis | 1,820 | 2.00 | 0.01 |
Backend network
7 rows
Assigned blockDefault
Trainium3 - Teton3 Max - EFAv4 - 3L - ETH - TH3 - AWS - 2
BackendXPU: Trainium3 Teton3 Max7 linesshared by 1 SKU
Backend Parts Summary
7
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Generic 400G AEC | 131,072 | 144.00 | 1.00 |
| EFAv4 Nitro-v6 400G NIC | 65,536 | 72.00 | 0.50 |
| Generic 400G DR4 | 131,072 | 144.00 | 1.00 |
| Generic 400G Single Mode | 262,144 | 288.00 | 2.00 |
| WhiteBox Tomahawk 3 12.8T | 8,192 | 9.00 | 0.06 |
| Generic 800G DR8 | 196,608 | 216.00 | 1.50 |
| WhiteBox Tomahawk 5 51.2T | 3,072 | 3.38 | 0.02 |
Frontend network
Frontend Parts Summary
0
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|
Compute Tray Networking Content
3 rows
Assigned blockDefault
Trainium3 - Teton3 Max - AWS
Compute TrayXPU: Trainium3 Teton3 Max3 linesshared by 3 SKUs
Compute Tray Parts Summary
3
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Astera Labs Scorpio-P 32-Lane PCIe Gen 6.0 | 65,536 | 72.00 | 0.50 |
| Aries PG6032 16L/32L Gearbox | 65,536 | 72.00 | 0.50 |
| Aries PCIe 6.0 x16 Retimer | 131,072 | 144.00 | 1.00 |
2026 share
Astera Labs Scorpio X 320-lane PCIe Gen 6.0Σ 100%
%
Astera Labs Scorpio-P 32-Lane PCIe Gen 6.0Σ 100%
%
Paladin HD 112Gb/s 320 DP (Male)Σ 100%
%
Paladin HD 112Gb/s 320 DP (Female)Σ 100%
%
112Gb/s SkewClear EXD CableΣ 100%
%
Strada Whisper 112Gb/s 80 DP Absolute Connector (Male)Σ 100%
%
Strada Whisper 112Gb/s 80 DP Absolute Connector (Female)Σ 100%
%
Generic PCIe Gen6 x16 (128Gb/s uni-di) 2-meter AECΣ 100%
%
Teton3 Backplane ChassisΣ 100%
%
| Item | Unit Cost | Quantity | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Per-server cost: $215,283.20 | |||||||||||||||||||||
| $2,000.00 | 36,409 | 40.00 | 0.28 | $72,817,777.78 | $80,000.00 | 300 W | 10,922,667 W | 12,000 W | Scale-Up Switch | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-320L | |
| $70.00 | 262,144 | 288.00 | 2.00 | $18,350,080.00 | $20,160.00 | 80 W | 20,971,520 W | 23,040 W | Scale-Up Switch | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-320L | |
| $220.80 | 72,818 | 80.00 | 0.56 | $16,078,165.33 | $17,664.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-320L | |
| $73.60 | 72,818 | 80.00 | 0.56 | $5,359,388.44 | $5,888.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-320L | |
| $1.00 | 23,301,689 | 25,600.00 | 177.78 | $23,301,688.89 | $25,600.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-320L | |
| $52.80 | 262,144 | 288.00 | 2.00 | $13,841,203.20 | $15,206.40 | 0 W | 0 W | 0 W | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-320L | |
| $17.60 | 262,144 | 288.00 | 2.00 | $4,613,734.40 | $5,068.80 | 0 W | 0 W | 0 W | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-320L | |
| $420.00 | 65,536 | 72.00 | 0.50 | $27,525,120.00 | $30,240.00 | 4 W | 262,144 W | 288 W | AEC | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-320L | |
| $7,728.00 | 1,820 | 2.00 | 0.01 | $14,068,394.67 | $15,456.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Others | — | Device Level | — | — | — | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-320L | |
Per-server cost: $330,652.50 | |||||||||||||||||||||
| $250.00 | 131,072 | 144.00 | 1.00 | $32,768,000.00 | $36,000.00 | 12 W | 1,572,864 W | 1,728 W | AEC | Amazon | Astera | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-320L | |
| $480.00 | 65,536 | 2.00 | 0.50 | $31,457,280.00 | $960.00 | 50 W | 3,276,800 W | 100 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-320L | |
| $260.00 | 131,072 | 144.00 | 1.00 | $34,078,720.00 | $37,440.00 | 10 W | 1,310,720 W | 1,440 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-320L | |
| $130.00 | 262,144 | 288.00 | 2.00 | $34,078,720.00 | $37,440.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Amphenol | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-320L | |
| $5,000.00 | 8,192 | 9.00 | 0.06 | $40,960,000.00 | $45,000.00 | 450 W | 3,686,400 W | 4,050 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-320L | |
| $500.00 | 196,608 | 216.00 | 1.50 | $98,304,000.00 | $108,000.00 | 16 W | 3,145,728 W | 3,456 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-320L | |
| $19,500.00 | 3,072 | 3.38 | 0.02 | $59,904,000.00 | $65,812.50 | 1,200 W | 3,686,400 W | 4,050 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-320L | |
Per-server cost: $12,780.00 | |||||||||||||||||||||
| $70.00 | 65,536 | 72.00 | 0.50 | $4,587,520.00 | $5,040.00 | 80 W | 5,242,880 W | 5,760 W | Scale-Up Switch | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium3 | Compute Tray | AWS-Teton3 MAX-Nv6-EFA-WB-320L | |
| $20.00 | 65,536 | 72.00 | 0.50 | $1,310,720.00 | $1,440.00 | 3 W | 196,608 W | 216 W | Gearbox | Amazon | Astera | — | L1 Abstraction | — | — | — | — | Trainium3 | Compute Tray | AWS-Teton3 MAX-Nv6-EFA-WB-320L | |
| $43.75 | 131,072 | 144.00 | 1.00 | $5,734,400.00 | $6,300.00 | 11 W | 1,441,792 W | 1,584 W | Retimer | Amazon | Astera | — | L1 Abstraction | — | — | — | — | Trainium3 | Compute Tray | AWS-Teton3 MAX-Nv6-EFA-WB-320L | |
| By fabric | |||||||||||||||||||||
| Total Scale-Up | $195,955,552.71 | $215,283.20 | 32,156,331 W | 35,328 W | |||||||||||||||||
| Total Backend | $331,550,720.00 | $330,652.50 | 16,678,912 W | 14,824 W | |||||||||||||||||
| Total Compute Tray | $11,632,640.00 | $12,780.00 | 6,881,280 W | 7,560 W | |||||||||||||||||
| Grand Total Cluster Networking | $539,138,912.71 | $558,715.70 | 55,716,523 W | 57,712 W | |||||||||||||||||
| By component | |||||||||||||||||||||
| Total Transceivers | $132,382,720.00 | $145,440.00 | 4,456,448 W | 4,896 W | |||||||||||||||||
| Total Switches | $100,864,000.00 | $110,812.50 | 7,372,800 W | 8,100 W | |||||||||||||||||
| Total Fiber | $34,078,720.00 | $37,440.00 | 0 W | 0 W | |||||||||||||||||
| Total Cables | — | — | — | — | |||||||||||||||||
| Total Connectors | — | — | — | — | |||||||||||||||||
| Total NICs | $31,457,280.00 | $960.00 | 3,276,800 W | 100 W | |||||||||||||||||