Live DB — analyst tables
Test
Neocloud Giant 18432 R200 HGX CX-9 Neocloud Giant Infiniband Cluster Configuration
NG-R200-IB-8R CPO
Neocloud Giant · R200 · CX-9
Rack type
HGX NVL8
Cluster / location
Default R200 HGX
Buyer profile
Neocloud Giant
Networking type
Infiniband
Number of XPUs
18,432
NIC used
CX-9
NICs / XPU
1
Scale-out BW / XPU
800G
XPU / server
8
Scale-up network
1 rows
Assigned blockDefault
R200 - HGX NVL8
Scale-UpXPU: R200 HGX NVL81 lineshared by 4 SKUs
Scale-Up Parts Summary
1
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia NVSwitch 6.0 (NVLink 6) | 9,216 | 4.00 | 0.50 |
Backend network
4 rows
Assigned blockDefault
R200 - HGX NVL8 - CX9 - 3L - IB - X800-Q3450 CPO - Generic
BackendXPU: R200 HGX NVL84 linesshared by 2 SKUs
Backend Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia LinkX 800G DR4 | 18,432 | 8.00 | 1.00 |
| Nvidia LinkX 800G DR4 Single Mode | 55,296 | 24.00 | 3.00 |
| ConnectX-9 NIC - 800G | 18,432 | 8.00 | 1.00 |
| Quantum-X800-Q3450 CPO | 640 | 0.28 | 0.03 |
Frontend network
11 rows
Assigned blockDefault
R200 - HGX NVL8 - SN6600 - Generic
FrontendXPU: R200 HGX NVL811 linesshared by 4 SKUs
Frontend Parts Summary
11
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Spectrum-6 102.4T x1600 (SN6600) | 221 | 0 | 0.0120 |
| Spectrum-4 25.6T (SN5400) | 1 | 0 | 0.0001 |
| Spectrum-3 12.8T (SN4700) | 33 | 0 | 0.0018 |
| Spectrum-2 1GbE (SN2201) | 271 | 0 | 0.0147 |
| Nvidia LinkX 1.6T DR8 (SiPho) | 10,704 | 5 | 0.5807 |
| Nvidia LinkX 800G DR4 | 10,648 | 5 | 0.5777 |
| Nvidia LinkX 200G SR4 | 4,725 | 2 | 0.2563 |
| Nvidia LinkX 800G Multimode | 14,649 | 6 | 0.7947 |
| Nvidia LinkX 400G Multimode | 75 | 0 | 0.0041 |
| Nvidia LinkX 200G Multimode | 2,105 | 1 | 0.1142 |
| RJ45 Cables | 12,990 | 6 | 0.7048 |
Compute Tray Networking Content
4 rows
Assigned blockDefault
R200 - HGX NVL8 - Generic
Compute TrayXPU: R200 HGX NVL84 linesshared by 4 SKUs
Compute Tray Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| NV Paladin Board to Board 32 Pin 4p8c (Male) | 18,432 | 8.00 | 1.00 |
| NV Paladin Board to Board 64 Pin 4p16c (Male) | 73,728 | 32.00 | 4.00 |
| NV Paladin Board to Board 32 Pin 4p8c (Female) | 18,432 | 8.00 | 1.00 |
| NV Paladin Board to Board 64 Pin 4p16c (Female) | 73,728 | 32.00 | 4.00 |
2026 share
Nvidia NVSwitch 6.0 (NVLink 6)Σ 100%
%
| Item | Unit Cost | Quantity | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Per-server cost: $17,600.00 | |||||||||||||||||||||
| $4,400.00 | 9,216 | 4.00 | 0.50 | $40,550,400.00 | $17,600.00 | 650 W | 5,990,400 W | 2,600 W | Scale-Up Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | NVLink | — | R200 | Scale-Up | NG-R200-IB-8R CPO | |
Per-server cost: $90,384.44 | |||||||||||||||||||||
| $1,200.00 | 18,432 | 8.00 | 1.00 | $22,118,400.00 | $9,600.00 | 17 W | 313,344 W | 136 W | Transceiver | Neocloud Giant | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | R200 | Backend | NG-R200-IB-8R CPO | |
| $390.00 | 55,296 | 24.00 | 3.00 | $21,565,440.00 | $9,360.00 | — | — | — | Fiber | Neocloud Giant | Others | — | White Label | — | — | — | — | R200 | Backend | NG-R200-IB-8R CPO | |
| $1,815.00 | 18,432 | 8.00 | 1.00 | $33,454,080.00 | $14,520.00 | 90 W | 1,658,880 W | 720 W | NIC | Neocloud Giant | Nvidia | — | Device Level | — | — | — | — | R200 | Backend | NG-R200-IB-8R CPO | |
| $204,856.00 | 640 | 0.28 | 0.03 | $131,107,840.00 | $56,904.44 | 3,548 W | 2,270,720 W | 986 W | Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | — | CPO | R200 | Backend | NG-R200-IB-8R CPO | |
Per-server cost: $29,664.86 | |||||||||||||||||||||
| $98,000.00 | 221 | 0.10 | 0.01 | $21,683,200.01 | $9,411.11 | 1,344 W | 297,260 W | 129 W | Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | Ethernet | — | R200 | Frontend | NG-R200-IB-8R CPO | |
| $16,500.00 | 1 | 0.00 | 0.00 | $15,085.72 | $6.55 | 670 W | 613 W | 0 W | Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | Ethernet | — | R200 | Frontend | NG-R200-IB-8R CPO | |
| $27,000.00 | 33 | 0.01 | 0.00 | $888,685.72 | $385.71 | 630 W | 20,736 W | 9 W | Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | Ethernet | — | R200 | Frontend | NG-R200-IB-8R CPO | |
| $3,000.00 | 271 | 0.12 | 0.01 | $811,885.71 | $352.38 | 150 W | 40,594 W | 18 W | Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | Ethernet | — | R200 | Frontend | NG-R200-IB-8R CPO | |
| $1,900.00 | 10,704 | 4.65 | 0.58 | $20,336,731.43 | $8,826.71 | 22 W | 235,478 W | 102 W | Transceiver | Neocloud Giant | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | R200 | Frontend | NG-R200-IB-8R CPO | |
| $1,200.00 | 10,648 | 4.62 | 0.58 | $12,777,325.71 | $5,545.71 | 17 W | 181,012 W | 79 W | Transceiver | Neocloud Giant | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | R200 | Frontend | NG-R200-IB-8R CPO | |
| $341.25 | 4,725 | 2.05 | 0.26 | $1,612,416.00 | $699.83 | 5 W | 23,625 W | 10 W | Transceiver | Neocloud Giant | Nvidia | Mellanox, Others | White Label | — | 56G | InfiniBand | Fully Retimed | R200 | Frontend | NG-R200-IB-8R CPO | |
| $630.00 | 14,649 | 6.36 | 0.79 | $9,228,672.00 | $4,005.50 | 0 W | 0 W | 0 W | Fiber | Neocloud Giant | Others | — | White Label | — | — | — | — | R200 | Frontend | NG-R200-IB-8R CPO | |
| $450.00 | 75 | 0.03 | 0.00 | $33,737.14 | $14.64 | 0 W | 0 W | 0 W | Fiber | Neocloud Giant | Others | — | White Label | — | — | — | — | R200 | Frontend | NG-R200-IB-8R CPO | |
| $450.00 | 2,105 | 0.91 | 0.11 | $947,108.57 | $411.07 | 0 W | 0 W | 0 W | Fiber | Neocloud Giant | Others | — | White Label | — | — | — | — | R200 | Frontend | NG-R200-IB-8R CPO | |
| $1.00 | 12,990 | 5.64 | 0.70 | $12,990.17 | $5.64 | 0 W | 0 W | 0 W | Cable | Neocloud Giant | Amphenol | — | Device Level | — | — | — | — | R200 | Frontend | NG-R200-IB-8R CPO | |
Per-server cost: $6,912.00 | |||||||||||||||||||||
| $64.00 | 18,432 | 8.00 | 1.00 | $1,179,648.00 | $512.00 | 0 W | 0 W | 0 W | Midplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | R200 | Compute Tray | NG-R200-IB-8R CPO | |
| $128.00 | 73,728 | 32.00 | 4.00 | $9,437,184.00 | $4,096.00 | 0 W | 0 W | 0 W | Midplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | R200 | Compute Tray | NG-R200-IB-8R CPO | |
| $32.00 | 18,432 | 8.00 | 1.00 | $589,824.00 | $256.00 | 0 W | 0 W | 0 W | Midplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | R200 | Compute Tray | NG-R200-IB-8R CPO | |
| $64.00 | 73,728 | 32.00 | 4.00 | $4,718,592.00 | $2,048.00 | 0 W | 0 W | 0 W | Midplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | R200 | Compute Tray | NG-R200-IB-8R CPO | |
| By fabric | |||||||||||||||||||||
| Total Scale-Up | $40,550,400.00 | $17,600.00 | 5,990,400 W | 2,600 W | |||||||||||||||||
| Total Backend | $208,245,760.00 | $90,384.44 | 4,242,944 W | 1,842 W | |||||||||||||||||
| Total Frontend | $68,347,838.20 | $29,664.86 | 799,318 W | 347 W | |||||||||||||||||
| Total Compute Tray | $15,925,248.00 | $6,912.00 | 0 W | 0 W | |||||||||||||||||
| Grand Total Cluster Networking | $333,069,246.20 | $144,561.30 | 11,032,662 W | 4,788 W | |||||||||||||||||
| By component | |||||||||||||||||||||
| Total Transceivers | $56,844,873.14 | $24,672.25 | 753,459 W | 327 W | |||||||||||||||||
| Total Switches | $154,506,697.17 | $67,060.20 | 2,629,922 W | 1,141 W | |||||||||||||||||
| Total Fiber | $31,774,957.71 | $13,791.21 | 0 W | 0 W | |||||||||||||||||
| Total Cables | $12,990.17 | $5.64 | 0 W | 0 W | |||||||||||||||||
| Total Connectors | — | — | — | — | |||||||||||||||||
| Total NICs | $33,454,080.00 | $14,520.00 | 1,658,880 W | 720 W | |||||||||||||||||