Neocloud Giant 18432 GB300 CX-8 Neocloud Giant InfiniBand Cluster Configuration
NG-GB300-CX8-IB-NV-2L-CPO
Neocloud Giant · GB300 · CX-8
Rack type
NVL72
Cluster / location
Default Neocloud GB300 XDR InfiniBand (2-Layer)
Buyer profile
Neocloud Giant
Networking type
InfiniBand
Number of XPUs
18,432
NIC used
CX-8
NICs / XPU
1
Scale-out BW / XPU
800G
XPU / server
72
Scale-up network
8 rows
Assigned blockDefault
GB300 - NVL72
Scale-UpXPU: GB300 NVL728 linesshared by 22 SKUs
Scale-Up Parts Summary
8
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia NVSwitch 5.0 (NVLink 5) | 4,608 | 18.00 | 0.25 |
| NV 2 UltraPass OverPass 144 DP 224Gb/s | 9,216 | 36.00 | 0.50 |
| NV Paladin HD2 224Gb/s 144 DP (Male) | 9,216 | 36.00 | 0.50 |
| NV Paladin HD2 224Gb/s 144 DP (Female) | 9,216 | 36.00 | 0.50 |
| NV Paladin HD2 224Gb/s 72 DP (Male) | 18,432 | 72.00 | 1.00 |
| NV Paladin HD2 224Gb/s 72 DP (Female) | 18,432 | 72.00 | 1.00 |
| NV 224Gb/s SkewClear EXD Gen 2 Cable | 1,327,104 | 5,184.00 | 72.00 |
| NVL Spine Chassis (NvLink 5) | 512 | 2.00 | 0.03 |
Backend network
5 rows
Assigned blockDefault
GB300 - NVL72 - CX8 - 2L - IB - X800-Q3450 CPO - Generic
BackendXPU: GB300 NVL725 linesshared by 1 SKU
Backend Parts Summary
5
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia LinkX 800G DR4 | 18,432 | 72.00 | 1.00 |
| Nvidia LinkX 800G DR4 Single Mode | 36,864 | 144.00 | 2.00 |
| Nvidia LinkX 1.6T DR8 (SiPho) | 27,648 | 108.00 | 1.50 |
| ConnectX-8 NIC - 800G | 18,432 | 72.00 | 1.00 |
| Quantum-X800-Q3450 CPO | 384 | 1.50 | 0.02 |
Frontend network
11 rows
Assigned blockDefault
GB300 - NVL72 - SN5600 - Generic
FrontendXPU: GB300 NVL7211 linesshared by 10 SKUs
Frontend Parts Summary
11
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Spectrum-4 51.2T (SN5600) | 1,573 | 6 | 0.0854 |
| Spectrum-3 12.8T (SN4700) | 7 | 0 | 0.0004 |
| Spectrum-2 6.4T (SN3700) | 234 | 1 | 0.0127 |
| Spectrum-2 1GbE (SN2201) | 1,924 | 8 | 0.1044 |
| Nvidia LinkX 800G SR8 | 76,114 | 297 | 4.1295 |
| Nvidia LinkX 400G SR4 | 75,717 | 296 | 4.1079 |
| Nvidia LinkX 100G SR4 QSFP28 | 33,600 | 131 | 1.8229 |
| Nvidia LinkX 800G Multimode | 104,168 | 407 | 5.6515 |
| Nvidia LinkX 400G Multimode | 533 | 2 | 0.0289 |
| Nvidia LinkX 100G Multimode | 14,967 | 58 | 0.8120 |
| RJ45 Cables | 92,375 | 361 | 5.0116 |
Compute Tray Networking Content
3 rows
Assigned blockDefault
GB300 - NVL72 - Generic
Compute TrayXPU: GB300 NVL723 linesshared by 20 SKUs
Compute Tray Parts Summary
3
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| NV MCIO PCIe x16 Connector | 9,216 | 36.00 | 0.50 |
| NV MCIO PCIe x16 Cable | 9,216 | 36.00 | 0.50 |
| NV DensiLink OverPass to OSFP Cage | 18,432 | 72.00 | 1.00 |
2026 share
Nvidia NVSwitch 5.0 (NVLink 5)Σ 100%
%
NV 2 UltraPass OverPass 144 DP 224Gb/sΣ 100%
%
NV Paladin HD2 224Gb/s 144 DP (Male)Σ 100%
%
NV Paladin HD2 224Gb/s 144 DP (Female)Σ 100%
%
NV Paladin HD2 224Gb/s 72 DP (Male)Σ 100%
%
NV Paladin HD2 224Gb/s 72 DP (Female)Σ 100%
%
NV 224Gb/s SkewClear EXD Gen 2 CableΣ 100%
%
NVL Spine Chassis (NvLink 5)Σ 100%
%
| Item | Unit Cost | Quantity | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Per-server cost: $166,764.00 | |||||||||||||||||||||
| $3,200.00 | 4,608 | 18.00 | 0.25 | $14,745,600.00 | $57,600.00 | 407 W | 1,877,299 W | 7,333 W | Scale-Up Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | NVLink | — | GB300 | Scale-Up | NG-GB300-CX8-IB-NV-2L-CPO | |
| $720.00 | 9,216 | 36.00 | 0.50 | $6,635,520.00 | $25,920.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | — | — | — | GB300 | Scale-Up | NG-GB300-CX8-IB-NV-2L-CPO | |
| $576.00 | 9,216 | 36.00 | 0.50 | $5,308,416.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB300 | Scale-Up | NG-GB300-CX8-IB-NV-2L-CPO | |
| $288.00 | 9,216 | 36.00 | 0.50 | $2,654,208.00 | $10,368.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB300 | Scale-Up | NG-GB300-CX8-IB-NV-2L-CPO | |
| $288.00 | 18,432 | 72.00 | 1.00 | $5,308,416.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB300 | Scale-Up | NG-GB300-CX8-IB-NV-2L-CPO | |
| $144.00 | 18,432 | 72.00 | 1.00 | $2,654,208.00 | $10,368.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB300 | Scale-Up | NG-GB300-CX8-IB-NV-2L-CPO | |
| $4.00 | 1,327,104 | 5,184.00 | 72.00 | $5,308,416.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB300 | Scale-Up | NG-GB300-CX8-IB-NV-2L-CPO | |
| $150.00 | 512 | 2.00 | 0.03 | $76,800.00 | $300.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Others | Others | Device Level | — | — | NVLink | — | GB300 | Scale-Up | NG-GB300-CX8-IB-NV-2L-CPO | |
Per-server cost: $661,644.00 | |||||||||||||||||||||
| $1,200.00 | 18,432 | 72.00 | 1.00 | $22,118,400.00 | $86,400.00 | 17 W | 313,344 W | 1,224 W | Transceiver | Neocloud Giant | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | GB300 | Backend | NG-GB300-CX8-IB-NV-2L-CPO | |
| $390.00 | 36,864 | 144.00 | 2.00 | $14,376,960.00 | $56,160.00 | — | — | — | Fiber | Neocloud Giant | Others | — | White Label | — | — | — | — | GB300 | Backend | NG-GB300-CX8-IB-NV-2L-CPO | |
| $1,900.00 | 27,648 | 108.00 | 1.50 | $52,531,200.00 | $205,200.00 | 22 W | 608,256 W | 2,376 W | Transceiver | Neocloud Giant | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | GB300 | Backend | NG-GB300-CX8-IB-NV-2L-CPO | |
| $1,650.00 | 18,432 | 4.00 | 1.00 | $30,412,800.00 | $6,600.00 | 75 W | 1,382,400 W | 300 W | NIC | Neocloud Giant | Nvidia | — | Device Level | — | — | — | — | GB300 | Backend | NG-GB300-CX8-IB-NV-2L-CPO | |
| $204,856.00 | 384 | 1.50 | 0.02 | $78,664,704.00 | $307,284.00 | 3,548 W | 1,362,432 W | 5,322 W | Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | — | CPO | GB300 | Backend | NG-GB300-CX8-IB-NV-2L-CPO | |
Per-server cost: $164,137.78 | |||||||||||||||||||||
| $55,000.00 | 221 | 0.86 | 0.01 | $12,169,142.87 | $47,535.71 | 950 W | 210,194 W | 821 W | Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | Ethernet | — | GB300 | Frontend | NG-GB300-CX8-IB-NV-2L-CPO | |
| $27,000.00 | 1 | 0.00 | 0.00 | $24,685.72 | $96.43 | 630 W | 576 W | 2 W | Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | Ethernet | — | GB300 | Frontend | NG-GB300-CX8-IB-NV-2L-CPO | |
| $14,600.86 | 33 | 0.13 | 0.00 | $480,576.79 | $1,877.25 | 250 W | 8,229 W | 32 W | Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | Ethernet | — | GB300 | Frontend | NG-GB300-CX8-IB-NV-2L-CPO | |
| $3,000.00 | 271 | 1.06 | 0.01 | $811,885.71 | $3,171.43 | 150 W | 40,594 W | 159 W | Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | Ethernet | — | GB300 | Frontend | NG-GB300-CX8-IB-NV-2L-CPO | |
| $1,050.00 | 10,704 | 41.81 | 0.58 | $11,238,720.00 | $43,901.25 | 14 W | 149,850 W | 585 W | Transceiver | Neocloud Giant | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 112G | InfiniBand | Fully Retimed | GB300 | Frontend | NG-GB300-CX8-IB-NV-2L-CPO | |
| $603.75 | 10,648 | 41.59 | 0.58 | $6,428,592.00 | $25,111.69 | 9 W | 95,830 W | 374 W | Transceiver | Neocloud Giant | Nvidia | Coherent, Innolight, Mellanox | White Label | — | 112G | InfiniBand | Fully Retimed | GB300 | Frontend | NG-GB300-CX8-IB-NV-2L-CPO | |
| $136.12 | 4,725 | 18.46 | 0.26 | $643,161.70 | $2,512.35 | 3 W | 14,175 W | 55 W | Transceiver | Neocloud Giant | Nvidia | Mellanox, Others | White Label | — | 28G | InfiniBand | Fully Retimed | GB300 | Frontend | NG-GB300-CX8-IB-NV-2L-CPO | |
| $630.00 | 14,649 | 57.22 | 0.79 | $9,228,672.00 | $36,049.50 | 0 W | 0 W | 0 W | Fiber | Neocloud Giant | Others | — | White Label | — | — | — | — | GB300 | Frontend | NG-GB300-CX8-IB-NV-2L-CPO | |
| $450.00 | 75 | 0.29 | 0.00 | $33,737.14 | $131.79 | 0 W | 0 W | 0 W | Fiber | Neocloud Giant | Others | — | White Label | — | — | — | — | GB300 | Frontend | NG-GB300-CX8-IB-NV-2L-CPO | |
| $450.00 | 2,105 | 8.22 | 0.11 | $947,108.57 | $3,699.64 | 0 W | 0 W | 0 W | Fiber | Neocloud Giant | Others | — | White Label | — | — | — | — | GB300 | Frontend | NG-GB300-CX8-IB-NV-2L-CPO | |
| $1.00 | 12,990 | 50.74 | 0.70 | $12,990.17 | $50.74 | 0 W | 0 W | 0 W | Cable | Neocloud Giant | Amphenol | — | Device Level | — | — | — | — | GB300 | Frontend | NG-GB300-CX8-IB-NV-2L-CPO | |
Per-server cost: $4,005.00 | |||||||||||||||||||||
| $1.25 | 9,216 | 36.00 | 0.50 | $11,520.00 | $45.00 | 0 W | 0 W | 0 W | Connector | Neocloud Giant | Amphenol | Amphenol | White Label | — | — | — | — | GB300 | Compute Tray | NG-GB300-CX8-IB-NV-2L-CPO | |
| $35.00 | 9,216 | 36.00 | 0.50 | $322,560.00 | $1,260.00 | 0 W | 0 W | 0 W | Cable | Neocloud Giant | Amphenol | Amphenol | White Label | — | — | — | — | GB300 | Compute Tray | NG-GB300-CX8-IB-NV-2L-CPO | |
| $37.50 | 18,432 | 72.00 | 1.00 | $691,200.00 | $2,700.00 | 0 W | 0 W | 0 W | Cable | Neocloud Giant | Amphenol | Amphenol | White Label | — | — | — | — | GB300 | Compute Tray | NG-GB300-CX8-IB-NV-2L-CPO | |
| By fabric | |||||||||||||||||||||
| Total Scale-Up | $42,691,584.00 | $166,764.00 | 1,877,299 W | 7,333 W | |||||||||||||||||
| Total Backend | $198,104,064.00 | $661,644.00 | 3,666,432 W | 9,222 W | |||||||||||||||||
| Total Frontend | $42,019,272.67 | $164,137.78 | 519,448 W | 2,029 W | |||||||||||||||||
| Total Compute Tray | $1,025,280.00 | $4,005.00 | 0 W | 0 W | |||||||||||||||||
| Grand Total Cluster Networking | $283,840,200.67 | $996,550.78 | 6,063,179 W | 18,584 W | |||||||||||||||||
| By component | |||||||||||||||||||||
| Total Transceivers | $92,960,073.70 | $363,125.29 | 1,181,455 W | 4,615 W | |||||||||||||||||
| Total Switches | $92,150,995.09 | $359,964.82 | 1,622,025 W | 6,336 W | |||||||||||||||||
| Total Fiber | $24,586,477.71 | $96,040.93 | 0 W | 0 W | |||||||||||||||||
| Total Cables | $1,026,750.17 | $4,010.74 | 0 W | 0 W | |||||||||||||||||
| Total Connectors | $11,520.00 | $45.00 | 0 W | 0 W | |||||||||||||||||
| Total NICs | $30,412,800.00 | $6,600.00 | 1,382,400 W | 300 W | |||||||||||||||||