Live DB — analyst tables
Test
META-MI400X-THOR3-Eth-3L
META-MI400X-THOR3-Eth-3L
Meta · MI400X · Thor-3 800G NIC
Rack type
—
Cluster / location
MI400X - Ethernet Cluster
Buyer profile
Hyperscaler
Networking type
Ethernet
Number of XPUs
18,432
NIC used
Thor-3 800G NIC
NICs / XPU
3
Scale-out BW / XPU
2.4T
XPU / server
72
Scale-up network
7 rows
Assigned blockDefault
MI400X
Scale-UpXPU: MI400X7 linesshared by 5 SKUs
Scale-Up Parts Summary
7
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Tomahawk 6 102.4T ASIC | 3,072 | 12.00 | 0.17 |
| UALoE 224Gb/s 432 DP (Male) | 6,144 | 24.00 | 0.33 |
| UALoE 224Gb/s 432 DP (Female) | 6,144 | 24.00 | 0.33 |
| UALoE 224Gb/s 144 DP (Male) | 18,432 | 72.00 | 1.00 |
| UALoE 224Gb/s 144 DP (Female) | 18,432 | 72.00 | 1.00 |
| 224Gb/s SkewClear EXD Gen 2 Cable | 2,654,208 | 10,368.00 | 144.00 |
| Spine Chassis for MI400X | 256 | 1.00 | 0.01 |
Backend network
4 rows
Assigned blockDefault
MI400X - Thor3 - 3L - ETH - Minipack-4 OCP Rack - META
BackendXPU: MI400X4 linesshared by 1 SKU
Backend Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Generic 1.6T DR8 (SiPho) | 156,672 | 612.00 | 8.50 |
| Generic 800G Single Mode | 147,456 | 576.00 | 8.00 |
| Thor-3 800G NIC | 36,864 | 144.00 | 2.00 |
| Minipack-4 OCP Rack 102.4T | 2,160 | 8.44 | 0.12 |
Frontend network
11 rows
Assigned blockDefault
MI400X - WhiteBox TH6 - Generic
FrontendXPU: MI400X11 linesshared by 5 SKUs
Frontend Parts Summary
11
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| WhiteBox Tomahawk 6 102.4T | 1,573 | 6 | 0.0854 |
| WhiteBox Tomahawk 4 25.6T | 7 | 0 | 0.0004 |
| WhiteBox Tomahawk 3 12.8T | 234 | 1 | 0.0127 |
| WhiteBox Tomahawk 2 6.4T | 1,924 | 8 | 0.1044 |
| Generic 1.6T DR8 (SiPho) | 76,114 | 297 | 4.1295 |
| Generic 800G DR4 | 75,717 | 296 | 4.1079 |
| Generic 200G SR4 | 33,600 | 131 | 1.8229 |
| Generic 800G Multimode | 104,168 | 407 | 5.6515 |
| Generic 400G Multimode | 533 | 2 | 0.0289 |
| Generic 200G Multimode | 14,967 | 58 | 0.8120 |
| RJ45 Cables | 92,375 | 361 | 5.0116 |
Compute Tray Networking Content
4 rows
Assigned blockDefault
MI400X - Generic
Compute TrayXPU: MI400X4 linesshared by 5 SKUs
Compute Tray Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Paladin Board to Board 32 Pin 4p8c (Male) | 18,432 | 72.00 | 1.00 |
| Paladin Board to Board 64 Pin 4p16c (Male) | 73,728 | 288.00 | 4.00 |
| Paladin Board to Board 32 Pin 4p8c (Female) | 18,432 | 72.00 | 1.00 |
| Paladin Board to Board 64 Pin 4p16c (Female) | 73,728 | 288.00 | 4.00 |
2026 share
Tomahawk 6 102.4T ASICΣ 100%
%
UALoE 224Gb/s 432 DP (Male)Σ 100%
%
UALoE 224Gb/s 432 DP (Female)Σ 100%
%
UALoE 224Gb/s 144 DP (Male)Σ 100%
%
UALoE 224Gb/s 144 DP (Female)Σ 100%
%
224Gb/s SkewClear EXD Gen 2 CableΣ 100%
%
Spine Chassis for MI400XΣ 100%
%
| Item | Unit Cost | Quantity | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Per-server cost: $161,697.00 | |||||||||||||||||||||
| $10,000.00 | 3,072 | 12.00 | 0.17 | $30,720,000.00 | $120,000.00 | 1,000 W | 3,072,000 W | 12,000 W | Scale-Up Switch ASIC | Meta | Broadcom | — | L1 Abstraction | — | — | — | — | MI400X | Scale-Up | META-MI400X-THOR3-Eth-3L | |
| $432.00 | 6,144 | 24.00 | 0.33 | $2,654,208.00 | $10,368.00 | 0 W | 0 W | 0 W | Backplane | Meta | Others | — | Device Level | — | 224G | UALoE | — | MI400X | Scale-Up | META-MI400X-THOR3-Eth-3L | |
| $216.00 | 6,144 | 24.00 | 0.33 | $1,327,104.00 | $5,184.00 | 0 W | 0 W | 0 W | Backplane | Meta | Others | — | Device Level | — | 224G | UALoE | — | MI400X | Scale-Up | META-MI400X-THOR3-Eth-3L | |
| $144.00 | 18,432 | 72.00 | 1.00 | $2,654,208.00 | $10,368.00 | 0 W | 0 W | 0 W | Backplane | Meta | Others | — | Device Level | — | 224G | UALoE | — | MI400X | Scale-Up | META-MI400X-THOR3-Eth-3L | |
| $72.00 | 18,432 | 72.00 | 1.00 | $1,327,104.00 | $5,184.00 | 0 W | 0 W | 0 W | Backplane | Meta | Others | — | Device Level | — | 224G | UALoE | — | MI400X | Scale-Up | META-MI400X-THOR3-Eth-3L | |
| $1.00 | 2,654,208 | 10,368.00 | 144.00 | $2,654,208.00 | $10,368.00 | 0 W | 0 W | 0 W | Backplane | Meta | Amphenol | — | Device Level | — | 224G | — | — | MI400X | Scale-Up | META-MI400X-THOR3-Eth-3L | |
| $225.00 | 256 | 1.00 | 0.01 | $57,600.00 | $225.00 | — | — | — | Backplane | Meta | Others | — | Device Level | — | — | — | — | MI400X | Scale-Up | META-MI400X-THOR3-Eth-3L | |
Per-server cost: $989,487.50 | |||||||||||||||||||||
| $810.00 | 156,672 | 612.00 | 8.50 | $126,904,320.00 | $495,720.00 | 22 W | 3,446,784 W | 13,464 W | Transceiver | Meta | AAOI | — | Device Level | — | 224G | Ethernet | Fully Retimed | MI400X | Backend | META-MI400X-THOR3-Eth-3L | |
| $180.00 | 147,456 | 576.00 | 8.00 | $26,542,080.00 | $103,680.00 | 0 W | 0 W | 0 W | Fiber | Meta | Corning | — | Device Level | — | — | — | — | MI400X | Backend | META-MI400X-THOR3-Eth-3L | |
| $1,300.00 | 36,864 | 8.00 | 2.00 | $47,923,200.00 | $10,400.00 | 75 W | 2,764,800 W | 600 W | NIC | Meta | Broadcom | — | Device Level | — | — | — | — | MI400X | Backend | META-MI400X-THOR3-Eth-3L | |
| $45,000.00 | 2,160 | 8.44 | 0.12 | $97,200,000.00 | $379,687.50 | 1,300 W | 2,808,000 W | 10,969 W | Switch | Meta | Celestica | — | Device Level | — | — | — | — | MI400X | Backend | META-MI400X-THOR3-Eth-3L | |
Per-server cost: $115,156.50 | |||||||||||||||||||||
| $40,000.00 | 221 | 0.86 | 0.01 | $8,850,285.72 | $34,571.43 | 1,697 W | 375,486 W | 1,467 W | Switch | Meta | Accton | — | Device Level | — | — | — | — | MI400X | Frontend | META-MI400X-THOR3-Eth-3L | |
| $13,500.00 | 1 | 0.00 | 0.00 | $12,342.86 | $48.21 | 850 W | 777 W | 3 W | Switch | Meta | Accton | — | Device Level | — | — | — | — | MI400X | Frontend | META-MI400X-THOR3-Eth-3L | |
| $5,000.00 | 33 | 0.13 | 0.00 | $164,571.43 | $642.86 | 450 W | 14,811 W | 58 W | Switch | Meta | Accton | — | Device Level | — | — | — | — | MI400X | Frontend | META-MI400X-THOR3-Eth-3L | |
| $3,072.57 | 271 | 1.06 | 0.01 | $831,525.48 | $3,248.15 | 250 W | 67,657 W | 264 W | Switch | Meta | Accton | — | Device Level | — | — | — | — | MI400X | Frontend | META-MI400X-THOR3-Eth-3L | |
| $810.00 | 10,704 | 41.81 | 0.58 | $8,669,869.71 | $33,866.68 | 22 W | 235,478 W | 920 W | Transceiver | Meta | AAOI | — | Device Level | — | 224G | Ethernet | Fully Retimed | MI400X | Frontend | META-MI400X-THOR3-Eth-3L | |
| $650.00 | 10,648 | 41.59 | 0.58 | $6,921,051.43 | $27,035.36 | 17 W | 181,012 W | 707 W | Transceiver | Meta | AAOI | — | Device Level | — | 224G | Ethernet | Fully Retimed | MI400X | Frontend | META-MI400X-THOR3-Eth-3L | |
| $130.00 | 4,725 | 18.46 | 0.26 | $614,253.71 | $2,399.43 | 5 W | 23,625 W | 92 W | Transceiver | Meta | AAOI | — | Device Level | — | 56G | Ethernet | Fully Retimed | MI400X | Frontend | META-MI400X-THOR3-Eth-3L | |
| $210.00 | 14,649 | 57.22 | 0.79 | $3,076,224.00 | $12,016.50 | 0 W | 0 W | 0 W | Fiber | Meta | Others | — | Device Level | — | — | — | — | MI400X | Frontend | META-MI400X-THOR3-Eth-3L | |
| $150.00 | 75 | 0.29 | 0.00 | $11,245.71 | $43.93 | 0 W | 0 W | 0 W | Fiber | Meta | Others | — | Device Level | — | — | — | — | MI400X | Frontend | META-MI400X-THOR3-Eth-3L | |
| $150.00 | 2,105 | 8.22 | 0.11 | $315,702.86 | $1,233.21 | 0 W | 0 W | 0 W | Fiber | Meta | Corning | — | Device Level | — | — | — | — | MI400X | Frontend | META-MI400X-THOR3-Eth-3L | |
| $1.00 | 12,990 | 50.74 | 0.70 | $12,990.17 | $50.74 | 0 W | 0 W | 0 W | Cable | Meta | Amphenol | — | Device Level | — | — | — | — | MI400X | Frontend | META-MI400X-THOR3-Eth-3L | |
Per-server cost: $15,552.00 | |||||||||||||||||||||
| $16.00 | 18,432 | 72.00 | 1.00 | $294,912.00 | $1,152.00 | 0 W | 0 W | 0 W | Midplane | Meta | Amphenol | — | Device Level | — | 224G | — | — | MI400X | Compute Tray | META-MI400X-THOR3-Eth-3L | |
| $32.00 | 73,728 | 288.00 | 4.00 | $2,359,296.00 | $9,216.00 | 0 W | 0 W | 0 W | Midplane | Meta | Amphenol | — | Device Level | — | 224G | — | — | MI400X | Compute Tray | META-MI400X-THOR3-Eth-3L | |
| $8.00 | 18,432 | 72.00 | 1.00 | $147,456.00 | $576.00 | 0 W | 0 W | 0 W | Midplane | Meta | Amphenol | — | Device Level | — | 224G | — | — | MI400X | Compute Tray | META-MI400X-THOR3-Eth-3L | |
| $16.00 | 73,728 | 288.00 | 4.00 | $1,179,648.00 | $4,608.00 | 0 W | 0 W | 0 W | Midplane | Meta | Amphenol | — | Device Level | — | 224G | — | — | MI400X | Compute Tray | META-MI400X-THOR3-Eth-3L | |
| By fabric | |||||||||||||||||||||
| Total Scale-Up | $41,394,432.00 | $161,697.00 | 3,072,000 W | 12,000 W | |||||||||||||||||
| Total Backend | $298,569,600.00 | $989,487.50 | 9,019,584 W | 25,033 W | |||||||||||||||||
| Total Frontend | $29,480,063.09 | $115,156.50 | 898,847 W | 3,511 W | |||||||||||||||||
| Total Compute Tray | $3,981,312.00 | $15,552.00 | 0 W | 0 W | |||||||||||||||||
| Grand Total Cluster Networking | $373,425,407.09 | $1,281,893.00 | 12,990,431 W | 40,544 W | |||||||||||||||||
| By component | |||||||||||||||||||||
| Total Transceivers | $143,109,494.86 | $559,021.46 | 3,886,899 W | 15,183 W | |||||||||||||||||
| Total Switches | $107,058,725.49 | $418,198.15 | 3,266,732 W | 12,761 W | |||||||||||||||||
| Total Fiber | $29,945,252.57 | $116,973.64 | 0 W | 0 W | |||||||||||||||||
| Total Cables | $12,990.17 | $50.74 | 0 W | 0 W | |||||||||||||||||
| Total Connectors | — | — | — | — | |||||||||||||||||
| Total NICs | $47,923,200.00 | $10,400.00 | 2,764,800 W | 600 W | |||||||||||||||||