Live DB — analyst tables
Test
Neoclouds/AI Lab/SovAI 131072 MI400X Vulcano 800G NIC Neocloud Giant Ethernet Cluster Configuration
NG-MI400X-Vulcano-Eth-2L-AR-1.6
Neocloud Giant · MI400X · Vulcano 800G NIC
Rack type
—
Cluster / location
MI400X - Ethernet Cluster
Buyer profile
Neocloud Giant
Networking type
Ethernet
Number of XPUs
131,072
NIC used
Vulcano 800G NIC
NICs / XPU
2
Scale-out BW / XPU
1.6T
XPU / server
72
Scale-up network
7 rows
Assigned blockDefault
MI400X
Scale-UpXPU: MI400X7 linesshared by 5 SKUs
Scale-Up Parts Summary
7
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Tomahawk 6 102.4T ASIC | 21,845 | 12.00 | 0.17 |
| UALoE 224Gb/s 432 DP (Male) | 43,691 | 24.00 | 0.33 |
| UALoE 224Gb/s 432 DP (Female) | 43,691 | 24.00 | 0.33 |
| UALoE 224Gb/s 144 DP (Male) | 131,072 | 72.00 | 1.00 |
| UALoE 224Gb/s 144 DP (Female) | 131,072 | 72.00 | 1.00 |
| 224Gb/s SkewClear EXD Gen 2 Cable | 18,874,368 | 10,368.00 | 144.00 |
| Spine Chassis for MI400X | 1,820 | 1.00 | 0.01 |
Backend network
5 rows
Assigned blockDefault
MI400X - Vulcano - 2L - ETH - TH6 - Generic
BackendXPU: MI400X5 linesshared by 2 SKUs
Backend Parts Summary
5
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Generic 800G DR4 | 262,144 | 144.00 | 2.00 |
| Generic 800G Single Mode | 524,288 | 288.00 | 4.00 |
| Generic 1.6T DR8 (SiPho) | 393,216 | 216.00 | 3.00 |
| Vulcano 800G NIC | 262,144 | 144.00 | 2.00 |
| Arista Tomahawk 6 102.4T | 6,144 | 3.38 | 0.05 |
Frontend network
11 rows
Assigned blockDefault
MI400X - WhiteBox TH6 - Generic
FrontendXPU: MI400X11 linesshared by 5 SKUs
Frontend Parts Summary
11
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| WhiteBox Tomahawk 6 102.4T | 1,573 | 1 | 0.0120 |
| WhiteBox Tomahawk 4 25.6T | 7 | 0 | 0.0001 |
| WhiteBox Tomahawk 3 12.8T | 234 | 0 | 0.0018 |
| WhiteBox Tomahawk 2 6.4T | 1,924 | 1 | 0.0147 |
| Generic 1.6T DR8 (SiPho) | 76,114 | 42 | 0.5807 |
| Generic 800G DR4 | 75,717 | 42 | 0.5777 |
| Generic 200G SR4 | 33,600 | 18 | 0.2563 |
| Generic 800G Multimode | 104,168 | 57 | 0.7947 |
| Generic 400G Multimode | 533 | 0 | 0.0041 |
| Generic 200G Multimode | 14,967 | 8 | 0.1142 |
| RJ45 Cables | 92,375 | 51 | 0.7048 |
Compute Tray Networking Content
4 rows
Assigned blockDefault
MI400X - Generic
Compute TrayXPU: MI400X4 linesshared by 5 SKUs
Compute Tray Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Paladin Board to Board 32 Pin 4p8c (Male) | 131,072 | 72.00 | 1.00 |
| Paladin Board to Board 64 Pin 4p16c (Male) | 524,288 | 288.00 | 4.00 |
| Paladin Board to Board 32 Pin 4p8c (Female) | 131,072 | 72.00 | 1.00 |
| Paladin Board to Board 64 Pin 4p16c (Female) | 524,288 | 288.00 | 4.00 |
2026 share
Tomahawk 6 102.4T ASICΣ 100%
%
224Gb/s SkewClear EXD Gen 2 CableΣ 100%
%
| Item | Unit Cost | Quantity | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Per-server cost: $185,697.00 | |||||||||||||||||||||
| $12,000.00 | 21,845 | 12.00 | 0.17 | $262,144,000.00 | $144,000.00 | 1,000 W | 21,845,333 W | 12,000 W | Scale-Up Switch ASIC | Neocloud Giant | Broadcom | — | L1 Abstraction | — | — | — | — | MI400X | Scale-Up | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
| $432.00 | 43,691 | 24.00 | 0.33 | $18,874,368.00 | $10,368.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Others | — | Device Level | — | 224G | UALoE | — | MI400X | Scale-Up | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
| $216.00 | 43,691 | 24.00 | 0.33 | $9,437,184.00 | $5,184.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Others | — | Device Level | — | 224G | UALoE | — | MI400X | Scale-Up | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
| $144.00 | 131,072 | 72.00 | 1.00 | $18,874,368.00 | $10,368.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Others | — | Device Level | — | 224G | UALoE | — | MI400X | Scale-Up | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
| $72.00 | 131,072 | 72.00 | 1.00 | $9,437,184.00 | $5,184.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Others | — | Device Level | — | 224G | UALoE | — | MI400X | Scale-Up | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
| $1.00 | 18,874,368 | 10,368.00 | 144.00 | $18,874,368.00 | $10,368.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Amphenol | — | Device Level | — | 224G | — | — | MI400X | Scale-Up | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
| $225.00 | 1,820 | 1.00 | 0.01 | $409,600.00 | $225.00 | — | — | — | Backplane | Neocloud Giant | Others | — | Device Level | — | — | — | — | MI400X | Scale-Up | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
Per-server cost: $594,189.00 | |||||||||||||||||||||
| $715.00 | 262,144 | 144.00 | 2.00 | $187,432,960.00 | $102,960.00 | 17 W | 4,456,448 W | 2,448 W | Transceiver | Neocloud Giant | AAOI | — | Device Level | — | 224G | Ethernet | Fully Retimed | MI400X | Backend | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
| $216.00 | 524,288 | 288.00 | 4.00 | $113,246,208.00 | $62,208.00 | 0 W | 0 W | 0 W | Fiber | Neocloud Giant | Corning | — | Device Level | — | — | — | — | MI400X | Backend | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
| $891.00 | 393,216 | 216.00 | 3.00 | $350,355,456.00 | $192,456.00 | 22 W | 8,650,752 W | 4,752 W | Transceiver | Neocloud Giant | AAOI | — | Device Level | — | 224G | Ethernet | Fully Retimed | MI400X | Backend | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
| $1,305.00 | 262,144 | 8.00 | 2.00 | $342,097,920.00 | $10,440.00 | 75 W | 19,660,800 W | 600 W | NIC | Neocloud Giant | AMD | — | Device Level | — | — | — | — | MI400X | Backend | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
| $67,000.00 | 6,144 | 3.38 | 0.05 | $411,648,000.00 | $226,125.00 | 1,500 W | 9,216,000 W | 5,063 W | Switch | Neocloud Giant | Arista | — | Device Level | — | — | — | — | MI400X | Backend | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
Per-server cost: $115,637.14 | |||||||||||||||||||||
| $30,334.88 | 1,573 | 0.86 | 0.01 | $47,728,420.12 | $26,218.00 | 1,697 W | 2,670,121 W | 1,467 W | Switch | Neocloud Giant | Accton | — | Device Level | — | — | — | — | MI400X | Frontend | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
| $14,850.00 | 7 | 0.00 | 0.00 | $96,548.57 | $53.04 | 850 W | 5,526 W | 3 W | Switch | Neocloud Giant | Accton | — | Device Level | — | — | — | — | MI400X | Frontend | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
| $5,500.00 | 234 | 0.13 | 0.00 | $1,287,314.29 | $707.14 | 450 W | 105,326 W | 58 W | Switch | Neocloud Giant | Accton | — | Device Level | — | — | — | — | MI400X | Frontend | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
| $2,974.25 | 1,924 | 1.06 | 0.01 | $5,723,851.87 | $3,144.21 | 250 W | 481,117 W | 264 W | Switch | Neocloud Giant | Accton | — | Device Level | — | — | — | — | MI400X | Frontend | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
| $891.00 | 76,114 | 41.81 | 0.58 | $67,817,647.54 | $37,253.35 | 22 W | 1,674,510 W | 920 W | Transceiver | Neocloud Giant | AAOI | — | Device Level | — | 224G | Ethernet | Fully Retimed | MI400X | Frontend | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
| $715.00 | 75,717 | 41.59 | 0.58 | $54,138,002.29 | $29,738.89 | 17 W | 1,287,197 W | 707 W | Transceiver | Neocloud Giant | AAOI | — | Device Level | — | 224G | Ethernet | Fully Retimed | MI400X | Frontend | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
| $136.50 | 33,600 | 18.46 | 0.26 | $4,586,427.73 | $2,519.40 | 5 W | 168,001 W | 92 W | Transceiver | Neocloud Giant | AAOI | — | Device Level | — | 56G | Ethernet | Fully Retimed | MI400X | Frontend | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
| $252.00 | 104,168 | 57.22 | 0.79 | $26,250,444.80 | $14,419.80 | 0 W | 0 W | 0 W | Fiber | Neocloud Giant | Others | — | Device Level | — | — | — | — | MI400X | Frontend | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
| $180.00 | 533 | 0.29 | 0.00 | $95,963.43 | $52.71 | 0 W | 0 W | 0 W | Fiber | Neocloud Giant | Others | — | Device Level | — | — | — | — | MI400X | Frontend | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
| $180.00 | 14,967 | 8.22 | 0.11 | $2,693,997.71 | $1,479.86 | 0 W | 0 W | 0 W | Fiber | Neocloud Giant | Corning | — | Device Level | — | — | — | — | MI400X | Frontend | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
| $1.00 | 92,375 | 50.74 | 0.70 | $92,374.55 | $50.74 | 0 W | 0 W | 0 W | Cable | Neocloud Giant | Amphenol | — | Device Level | — | — | — | — | MI400X | Frontend | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
Per-server cost: $15,552.00 | |||||||||||||||||||||
| $16.00 | 131,072 | 72.00 | 1.00 | $2,097,152.00 | $1,152.00 | 0 W | 0 W | 0 W | Midplane | Neocloud Giant | Amphenol | — | Device Level | — | 224G | — | — | MI400X | Compute Tray | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
| $32.00 | 524,288 | 288.00 | 4.00 | $16,777,216.00 | $9,216.00 | 0 W | 0 W | 0 W | Midplane | Neocloud Giant | Amphenol | — | Device Level | — | 224G | — | — | MI400X | Compute Tray | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
| $8.00 | 131,072 | 72.00 | 1.00 | $1,048,576.00 | $576.00 | 0 W | 0 W | 0 W | Midplane | Neocloud Giant | Amphenol | — | Device Level | — | 224G | — | — | MI400X | Compute Tray | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
| $16.00 | 524,288 | 288.00 | 4.00 | $8,388,608.00 | $4,608.00 | 0 W | 0 W | 0 W | Midplane | Neocloud Giant | Amphenol | — | Device Level | — | 224G | — | — | MI400X | Compute Tray | NG-MI400X-Vulcano-Eth-2L-AR-1.6 | |
| By fabric | |||||||||||||||||||||
| Total Scale-Up | $338,051,072.00 | $185,697.00 | 21,845,333 W | 12,000 W | |||||||||||||||||
| Total Backend | $1,404,780,544.00 | $594,189.00 | 41,984,000 W | 12,863 W | |||||||||||||||||
| Total Frontend | $210,510,992.90 | $115,637.14 | 6,391,799 W | 3,511 W | |||||||||||||||||
| Total Compute Tray | $28,311,552.00 | $15,552.00 | 0 W | 0 W | |||||||||||||||||
| Grand Total Cluster Networking | $1,981,654,160.90 | $911,075.14 | 70,221,132 W | 28,374 W | |||||||||||||||||
| By component | |||||||||||||||||||||
| Total Transceivers | $664,330,493.56 | $364,927.64 | 16,236,908 W | 8,919 W | |||||||||||||||||
| Total Switches | $466,484,134.85 | $256,247.39 | 12,478,091 W | 6,854 W | |||||||||||||||||
| Total Fiber | $142,286,613.94 | $78,160.37 | 0 W | 0 W | |||||||||||||||||
| Total Cables | $92,374.55 | $50.74 | 0 W | 0 W | |||||||||||||||||
| Total Connectors | — | — | — | — | |||||||||||||||||
| Total NICs | $342,097,920.00 | $10,440.00 | 19,660,800 W | 600 W | |||||||||||||||||