Live DB — analyst tables
Test
Amazon 131072 GB200 NVL72 ConnectX-8 NIC - 800G Hyperscaler Ethernet Cluster Configuration
AWS-GB300 NVL72-CX8-Eth-WB
Amazon · GB300 · ConnectX-8 NIC - 800G
Rack type
NVL72
Cluster / location
GB300 NVL72 Clusters
Buyer profile
Hyperscaler
Networking type
Ethernet
Number of XPUs
131,072
NIC used
ConnectX-8 NIC - 800G
NICs / XPU
1
Scale-out BW / XPU
800G
XPU / server
72
Scale-up network
8 rows
Assigned blockDefault
GB300 - NVL72
Scale-UpXPU: GB300 NVL728 linesshared by 22 SKUs
Scale-Up Parts Summary
8
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia NVSwitch 5.0 (NVLink 5) | 32,768 | 18.00 | 0.25 |
| NV 2 UltraPass OverPass 144 DP 224Gb/s | 65,536 | 36.00 | 0.50 |
| NV Paladin HD2 224Gb/s 144 DP (Male) | 65,536 | 36.00 | 0.50 |
| NV Paladin HD2 224Gb/s 144 DP (Female) | 65,536 | 36.00 | 0.50 |
| NV Paladin HD2 224Gb/s 72 DP (Male) | 131,072 | 72.00 | 1.00 |
| NV Paladin HD2 224Gb/s 72 DP (Female) | 131,072 | 72.00 | 1.00 |
| NV 224Gb/s SkewClear EXD Gen 2 Cable | 9,437,184 | 5,184.00 | 72.00 |
| NVL Spine Chassis (NvLink 5) | 3,641 | 2.00 | 0.03 |
Backend network
7 rows
Assigned blockDefault
GB300 - NVL72 - CX8 - 3L - ETH - TH3 - AWS
BackendXPU: GB300 NVL727 linesshared by 1 SKU
Backend Parts Summary
7
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Generic 400G AEC | 262,144 | 144.00 | 2.00 |
| ConnectX-8 NIC - 800G | 131,072 | 72.00 | 1.00 |
| Generic 400G DR4 | 262,144 | 144.00 | 2.00 |
| Generic 400G Single Mode | 524,288 | 288.00 | 4.00 |
| WhiteBox Tomahawk 3 12.8T | 16,384 | 9.00 | 0.13 |
| Generic 800G DR8 | 393,216 | 216.00 | 3.00 |
| WhiteBox Tomahawk 5 51.2T | 6,144 | 3.38 | 0.05 |
Frontend network
Frontend Parts Summary
0
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|
Compute Tray Networking Content
4 rows
Assigned blockDefault
GB300 - NVL72 - AWS - Eth-WB
Compute TrayXPU: GB300 NVL724 linesshared by 1 SKU
Compute Tray Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| MCIO PCIe x16 Connector | 65,536 | 36.00 | 0.50 |
| MCIO PCIe x16 Cable | 65,536 | 36.00 | 0.50 |
| DensiLink OverPass to OSFP Cage | 131,072 | 72.00 | 1.00 |
| Astera Labs Scorpio-P 64-Lane PCIe Gen 5.0 | 131,072 | 72.00 | 1.00 |
2026 share
Nvidia NVSwitch 5.0 (NVLink 5)Σ 100%
%
NV 2 UltraPass OverPass 144 DP 224Gb/sΣ 100%
%
NV Paladin HD2 224Gb/s 144 DP (Male)Σ 100%
%
NV Paladin HD2 224Gb/s 144 DP (Female)Σ 100%
%
NV Paladin HD2 224Gb/s 72 DP (Male)Σ 100%
%
NV Paladin HD2 224Gb/s 72 DP (Female)Σ 100%
%
NV 224Gb/s SkewClear EXD Gen 2 CableΣ 100%
%
NVL Spine Chassis (NvLink 5)Σ 100%
%
| Item | Unit Cost | Quantity | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Per-server cost: $166,764.00 | |||||||||||||||||||||
| $3,200.00 | 32,768 | 18.00 | 0.25 | $104,857,600.00 | $57,600.00 | 407 W | 13,349,683 W | 7,333 W | Scale-Up Switch | Amazon | Nvidia | — | Device Level | — | — | NVLink | — | GB300 | Scale-Up | AWS-GB300 NVL72-CX8-Eth-WB | |
| $720.00 | 65,536 | 36.00 | 0.50 | $47,185,920.00 | $25,920.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | — | — | — | GB300 | Scale-Up | AWS-GB300 NVL72-CX8-Eth-WB | |
| $576.00 | 65,536 | 36.00 | 0.50 | $37,748,736.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB300 | Scale-Up | AWS-GB300 NVL72-CX8-Eth-WB | |
| $288.00 | 65,536 | 36.00 | 0.50 | $18,874,368.00 | $10,368.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB300 | Scale-Up | AWS-GB300 NVL72-CX8-Eth-WB | |
| $288.00 | 131,072 | 72.00 | 1.00 | $37,748,736.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB300 | Scale-Up | AWS-GB300 NVL72-CX8-Eth-WB | |
| $144.00 | 131,072 | 72.00 | 1.00 | $18,874,368.00 | $10,368.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB300 | Scale-Up | AWS-GB300 NVL72-CX8-Eth-WB | |
| $4.00 | 9,437,184 | 5,184.00 | 72.00 | $37,748,736.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB300 | Scale-Up | AWS-GB300 NVL72-CX8-Eth-WB | |
| $150.00 | 3,641 | 2.00 | 0.03 | $546,133.33 | $300.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Others | Others | Device Level | — | — | NVLink | — | GB300 | Scale-Up | AWS-GB300 NVL72-CX8-Eth-WB | |
Per-server cost: $335,692.50 | |||||||||||||||||||||
| $250.00 | 262,144 | 144.00 | 2.00 | $65,536,000.00 | $36,000.00 | 12 W | 3,145,728 W | 1,728 W | AEC | Amazon | Astera | — | Device Level | — | — | — | — | GB300 | Backend | AWS-GB300 NVL72-CX8-Eth-WB | |
| $1,500.00 | 131,072 | 4.00 | 1.00 | $196,608,000.00 | $6,000.00 | 75 W | 9,830,400 W | 300 W | NIC | Amazon | Nvidia | — | Device Level | — | — | — | — | GB300 | Backend | AWS-GB300 NVL72-CX8-Eth-WB | |
| $260.00 | 262,144 | 144.00 | 2.00 | $68,157,440.00 | $37,440.00 | 10 W | 2,621,440 W | 1,440 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | GB300 | Backend | AWS-GB300 NVL72-CX8-Eth-WB | |
| $130.00 | 524,288 | 288.00 | 4.00 | $68,157,440.00 | $37,440.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Amphenol | — | Device Level | — | — | — | — | GB300 | Backend | AWS-GB300 NVL72-CX8-Eth-WB | |
| $5,000.00 | 16,384 | 9.00 | 0.13 | $81,920,000.00 | $45,000.00 | 450 W | 7,372,800 W | 4,050 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | GB300 | Backend | AWS-GB300 NVL72-CX8-Eth-WB | |
| $500.00 | 393,216 | 216.00 | 3.00 | $196,608,000.00 | $108,000.00 | 16 W | 6,291,456 W | 3,456 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | GB300 | Backend | AWS-GB300 NVL72-CX8-Eth-WB | |
| $19,500.00 | 6,144 | 3.38 | 0.05 | $119,808,000.00 | $65,812.50 | 1,200 W | 7,372,800 W | 4,050 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | GB300 | Backend | AWS-GB300 NVL72-CX8-Eth-WB | |
Per-server cost: $12,402.00 | |||||||||||||||||||||
| $0.50 | 65,536 | 36.00 | 0.50 | $32,768.00 | $18.00 | 0 W | 0 W | 0 W | Connector | Amazon | Amphenol | — | White Label | — | — | — | — | GB300 | Compute Tray | AWS-GB300 NVL72-CX8-Eth-WB | |
| $14.00 | 65,536 | 36.00 | 0.50 | $917,504.00 | $504.00 | 0 W | 0 W | 0 W | Cable | Amazon | Amphenol | — | Device Level | — | — | — | — | GB300 | Compute Tray | AWS-GB300 NVL72-CX8-Eth-WB | |
| $15.00 | 131,072 | 72.00 | 1.00 | $1,966,080.00 | $1,080.00 | 0 W | 0 W | 0 W | Cable | Amazon | Amphenol | — | Device Level | — | — | — | — | GB300 | Compute Tray | AWS-GB300 NVL72-CX8-Eth-WB | |
| $150.00 | 131,072 | 72.00 | 1.00 | $19,660,800.00 | $10,800.00 | 130 W | 17,039,360 W | 9,360 W | Scale-Up Switch | Amazon | Astera | — | Device Level | — | — | PCIe | — | GB300 | Compute Tray | AWS-GB300 NVL72-CX8-Eth-WB | |
| By fabric | |||||||||||||||||||||
| Total Scale-Up | $303,584,597.33 | $166,764.00 | 13,349,683 W | 7,333 W | |||||||||||||||||
| Total Backend | $796,794,880.00 | $335,692.50 | 36,634,624 W | 15,024 W | |||||||||||||||||
| Total Compute Tray | $22,577,152.00 | $12,402.00 | 17,039,360 W | 9,360 W | |||||||||||||||||
| Grand Total Cluster Networking | $1,122,956,629.33 | $514,858.50 | 67,023,667 W | 31,717 W | |||||||||||||||||
| By component | |||||||||||||||||||||
| Total Transceivers | $264,765,440.00 | $145,440.00 | 8,912,896 W | 4,896 W | |||||||||||||||||
| Total Switches | $201,728,000.00 | $110,812.50 | 14,745,600 W | 8,100 W | |||||||||||||||||
| Total Fiber | $68,157,440.00 | $37,440.00 | 0 W | 0 W | |||||||||||||||||
| Total Cables | $2,883,584.00 | $1,584.00 | 0 W | 0 W | |||||||||||||||||
| Total Connectors | $32,768.00 | $18.00 | 0 W | 0 W | |||||||||||||||||
| Total NICs | $196,608,000.00 | $6,000.00 | 9,830,400 W | 300 W | |||||||||||||||||