Live DB — analyst tables
Test
Meta 16384 MTIA Gen 4 Thor-3 800G NIC Hyperscaler Ethernet Cluster Configuration
META-MTIA Gen 4-800G-Eth-3L
Meta · MTIA Gen 4 · Thor-3 800G NIC
Rack type
—
Cluster / location
All Other Clusters
Buyer profile
Hyperscaler
Networking type
Ethernet
Number of XPUs
16,384
NIC used
Thor-3 800G NIC
NICs / XPU
1
Scale-out BW / XPU
800G
XPU / server
72
Scale-up network
7 rows
Assigned blockDefault
MTIA Gen 4
Scale-UpXPU: MTIA Gen 47 linesshared by 1 SKU
Scale-Up Parts Summary
7
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Tomahawk 6 102.4T ASIC | 1,820 | 8.00 | 0.11 |
| 2 UltraPass OverPass 144 DP 224Gb/s | 10,923 | 48.00 | 0.67 |
| Paladin HD2 224Gb/s 144 DP (Male) | 10,923 | 48.00 | 0.67 |
| Paladin HD2 224Gb/s 144 DP (Female) | 10,923 | 48.00 | 0.67 |
| Paladin HD2 224Gb/s 96 DP (Male) | 16,384 | 72.00 | 1.00 |
| Paladin HD2 224Gb/s 96 DP (Female) | 16,384 | 72.00 | 1.00 |
| 224Gb/s SkewClear EXD Gen 2 Cable | 1,572,864 | 6,912.00 | 96.00 |
Backend network
5 rows
Assigned blockDefault
MTIA Gen 4 - Thor3 - 3L - ETH - Minipack-3 OCP Rack - META
BackendXPU: MTIA Gen 45 linesshared by 1 SKU
Backend Parts Summary
5
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Generic 800G AEC | 16,384 | 72.00 | 1.00 |
| Generic 800G DR8 | 65,536 | 288.00 | 4.00 |
| Generic 400G Single Mode | 65,536 | 288.00 | 4.00 |
| Thor-3 800G NIC | 16,384 | 72.00 | 1.00 |
| Minipack-3 OCP Rack 51.2T | 1,280 | 5.63 | 0.08 |
Frontend network
11 rows
Assigned blockDefault
MTIA Gen 4 - Minipack-3 - META
FrontendXPU: MTIA Gen 411 linesshared by 1 SKU
Frontend Parts Summary
11
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Minipack-3 OCP Rack 51.2T | 197 | 1 | 0.0120 |
| Minipack-1 OCP Rack 12.8T | 1 | 0 | 0.0001 |
| WhiteBox Tomahawk 2 6.4T | 29 | 0 | 0.0018 |
| Generic 1GbE Ethernet | 241 | 1 | 0.0147 |
| Generic 800G DR8 | 9,514 | 42 | 0.5807 |
| Generic 400G DR4 | 9,465 | 42 | 0.5777 |
| Generic 100G DR4 QSFP28 | 4,200 | 18 | 0.2563 |
| Generic 800G Single Mode | 13,021 | 57 | 0.7947 |
| Generic 400G Single Mode | 67 | 0 | 0.0041 |
| Generic 100G Single Mode | 1,871 | 8 | 0.1142 |
| RJ45 Cables | 11,547 | 51 | 0.7048 |
Compute Tray Networking Content
Assigned blockDefault
MTIA Gen 4 - META
Compute TrayXPU: MTIA Gen 40 linesshared by 1 SKU
Compute Tray Parts Summary
0
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|
2026 share
Tomahawk 6 102.4T ASICΣ 100%
%
2 UltraPass OverPass 144 DP 224Gb/sΣ 100%
%
Paladin HD2 224Gb/s 144 DP (Male)Σ 100%
%
Paladin HD2 224Gb/s 144 DP (Female)Σ 100%
%
Paladin HD2 224Gb/s 96 DP (Male)Σ 100%
%
Paladin HD2 224Gb/s 96 DP (Female)Σ 100%
%
224Gb/s SkewClear EXD Gen 2 CableΣ 100%
%
| Item | Unit Cost | Quantity | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Per-server cost: $121,472.00 | |||||||||||||||||||||
| $10,000.00 | 1,820 | 8.00 | 0.11 | $18,204,444.44 | $80,000.00 | 1,000 W | 1,820,444 W | 8,000 W | Scale-Up Switch ASIC | Meta | Broadcom | — | L1 Abstraction | — | — | — | — | MTIA Gen 4 | Scale-Up | META-MTIA Gen 4-800G-Eth-3L | |
| $288.00 | 10,923 | 48.00 | 0.67 | $3,145,728.00 | $13,824.00 | 0 W | 0 W | 0 W | Backplane | Meta | Amphenol | — | Device Level | — | — | — | — | MTIA Gen 4 | Scale-Up | META-MTIA Gen 4-800G-Eth-3L | |
| $144.00 | 10,923 | 48.00 | 0.67 | $1,572,864.00 | $6,912.00 | 0 W | 0 W | 0 W | Backplane | Meta | Amphenol | — | Device Level | — | 224G | — | — | MTIA Gen 4 | Scale-Up | META-MTIA Gen 4-800G-Eth-3L | |
| $72.00 | 10,923 | 48.00 | 0.67 | $786,432.00 | $3,456.00 | 0 W | 0 W | 0 W | Backplane | Meta | Amphenol | — | Device Level | — | 224G | — | — | MTIA Gen 4 | Scale-Up | META-MTIA Gen 4-800G-Eth-3L | |
| $96.00 | 16,384 | 72.00 | 1.00 | $1,572,864.00 | $6,912.00 | 0 W | 0 W | 0 W | Backplane | Meta | Amphenol | — | Device Level | — | 224G | — | — | MTIA Gen 4 | Scale-Up | META-MTIA Gen 4-800G-Eth-3L | |
| $48.00 | 16,384 | 72.00 | 1.00 | $786,432.00 | $3,456.00 | 0 W | 0 W | 0 W | Backplane | Meta | Amphenol | — | Device Level | — | 224G | — | — | MTIA Gen 4 | Scale-Up | META-MTIA Gen 4-800G-Eth-3L | |
| $1.00 | 1,572,864 | 6,912.00 | 96.00 | $1,572,864.00 | $6,912.00 | 0 W | 0 W | 0 W | Backplane | Meta | Amphenol | — | Device Level | — | 224G | — | — | MTIA Gen 4 | Scale-Up | META-MTIA Gen 4-800G-Eth-3L | |
Per-server cost: $353,590.00 | |||||||||||||||||||||
| $350.00 | 16,384 | 72.00 | 1.00 | $5,734,400.00 | $25,200.00 | 22 W | 367,002 W | 1,613 W | AEC | Meta | Astera | — | Device Level | — | — | — | — | MTIA Gen 4 | Backend | META-MTIA Gen 4-800G-Eth-3L | |
| $500.00 | 65,536 | 288.00 | 4.00 | $32,768,000.00 | $144,000.00 | 16 W | 1,048,576 W | 4,608 W | Transceiver | Meta | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | MTIA Gen 4 | Backend | META-MTIA Gen 4-800G-Eth-3L | |
| $130.00 | 65,536 | 288.00 | 4.00 | $8,519,680.00 | $37,440.00 | 0 W | 0 W | 0 W | Fiber | Meta | Amphenol | — | Device Level | — | — | — | — | MTIA Gen 4 | Backend | META-MTIA Gen 4-800G-Eth-3L | |
| $1,300.00 | 16,384 | 4.00 | 1.00 | $21,299,200.00 | $5,200.00 | 75 W | 1,228,800 W | 300 W | NIC | Meta | Broadcom | — | Device Level | — | — | — | — | MTIA Gen 4 | Backend | META-MTIA Gen 4-800G-Eth-3L | |
| $25,200.00 | 1,280 | 5.63 | 0.08 | $32,256,000.00 | $141,750.00 | 1,200 W | 1,536,000 W | 6,750 W | Switch | Meta | Accton | — | Device Level | — | — | — | — | MTIA Gen 4 | Backend | META-MTIA Gen 4-800G-Eth-3L | |
Per-server cost: $66,736.54 | |||||||||||||||||||||
| $25,200.00 | 197 | 0.86 | 0.01 | $4,956,160.00 | $21,780.00 | 1,200 W | 236,008 W | 1,037 W | Switch | Meta | Accton | — | Device Level | — | — | — | — | MTIA Gen 4 | Frontend | META-MTIA Gen 4-800G-Eth-3L | |
| $5,000.00 | 1 | 0.00 | 0.00 | $4,063.49 | $17.86 | 450 W | 366 W | 2 W | Switch | Meta | Celestica | — | Device Level | — | — | — | — | MTIA Gen 4 | Frontend | META-MTIA Gen 4-800G-Eth-3L | |
| $3,072.57 | 29 | 0.13 | 0.00 | $89,894.65 | $395.04 | 250 W | 7,314 W | 32 W | Switch | Meta | Accton | — | Device Level | — | — | — | — | MTIA Gen 4 | Frontend | META-MTIA Gen 4-800G-Eth-3L | |
| $350.00 | 241 | 1.06 | 0.01 | $84,195.56 | $370.00 | 100 W | 24,056 W | 106 W | Switch | Meta | Accton | — | Device Level | — | — | — | — | MTIA Gen 4 | Frontend | META-MTIA Gen 4-800G-Eth-3L | |
| $500.00 | 9,514 | 41.81 | 0.58 | $4,757,130.16 | $20,905.36 | 16 W | 152,228 W | 669 W | Transceiver | Meta | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | MTIA Gen 4 | Frontend | META-MTIA Gen 4-800G-Eth-3L | |
| $260.00 | 9,465 | 41.59 | 0.58 | $2,460,818.29 | $10,814.14 | 10 W | 94,647 W | 416 W | Transceiver | Meta | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | MTIA Gen 4 | Frontend | META-MTIA Gen 4-800G-Eth-3L | |
| $54.00 | 4,200 | 18.46 | 0.26 | $226,801.37 | $996.69 | 3 W | 12,600 W | 55 W | Transceiver | Meta | AAOI | — | Device Level | — | 28G | Ethernet | Fully Retimed | MTIA Gen 4 | Frontend | META-MTIA Gen 4-800G-Eth-3L | |
| $180.00 | 13,021 | 57.22 | 0.79 | $2,343,789.71 | $10,299.86 | 0 W | 0 W | 0 W | Fiber | Meta | Corning | — | Device Level | — | — | — | — | MTIA Gen 4 | Frontend | META-MTIA Gen 4-800G-Eth-3L | |
| $130.00 | 67 | 0.29 | 0.00 | $8,663.37 | $38.07 | 0 W | 0 W | 0 W | Fiber | Meta | Amphenol | — | Device Level | — | — | — | — | MTIA Gen 4 | Frontend | META-MTIA Gen 4-800G-Eth-3L | |
| $130.00 | 1,871 | 8.22 | 0.11 | $243,208.13 | $1,068.79 | 0 W | 0 W | 0 W | Fiber | Meta | Corning | — | Device Level | — | — | — | — | MTIA Gen 4 | Frontend | META-MTIA Gen 4-800G-Eth-3L | |
| $1.00 | 11,547 | 50.74 | 0.70 | $11,546.82 | $50.74 | 0 W | 0 W | 0 W | Cable | Meta | Amphenol | — | Device Level | — | — | — | — | MTIA Gen 4 | Frontend | META-MTIA Gen 4-800G-Eth-3L | |
| By fabric | |||||||||||||||||||||
| Total Scale-Up | $27,641,628.44 | $121,472.00 | 1,820,444 W | 8,000 W | |||||||||||||||||
| Total Backend | $100,577,280.00 | $353,590.00 | 4,180,378 W | 13,271 W | |||||||||||||||||
| Total Frontend | $15,186,271.54 | $66,736.54 | 527,219 W | 2,317 W | |||||||||||||||||
| Grand Total Cluster Networking | $143,405,179.98 | $541,798.54 | 6,528,041 W | 23,588 W | |||||||||||||||||
| By component | |||||||||||||||||||||
| Total Transceivers | $40,212,749.82 | $176,716.19 | 1,308,051 W | 5,748 W | |||||||||||||||||
| Total Switches | $37,390,313.70 | $164,312.90 | 1,803,743 W | 7,927 W | |||||||||||||||||
| Total Fiber | $11,115,341.21 | $48,846.71 | 0 W | 0 W | |||||||||||||||||
| Total Cables | $11,546.82 | $50.74 | 0 W | 0 W | |||||||||||||||||
| Total Connectors | — | — | — | — | |||||||||||||||||
| Total NICs | $21,299,200.00 | $5,200.00 | 1,228,800 W | 300 W | |||||||||||||||||