Live DB — analyst tables
Test
Meta 18144 GB300 CX-8 Hyperscaler DSF Ethernet Cluster Configuration

META-GB300-CX8-DSF-AR-18k

Meta · GB300 · CX-8

Rack type
NVL72
Cluster / location
All Other Clusters
Buyer profile
Hyperscaler
Networking type
DSF Ethernet
Number of XPUs
18,144
NIC used
CX-8
NICs / XPU
1
Scale-out BW / XPU
800G
XPU / server
72

Scale-up network

8 rows
Assigned blockDefault
GB300 - NVL72
Scale-UpXPU: GB300 NVL728 linesshared by 22 SKUs

Scale-Up Parts Summary

8
ItemQty/ClusterQty/ServerAttach/XPU
Nvidia NVSwitch 5.0 (NVLink 5)4,53618.000.25
NV 2 UltraPass OverPass 144 DP 224Gb/s9,07236.000.50
NV Paladin HD2 224Gb/s 144 DP (Male)9,07236.000.50
NV Paladin HD2 224Gb/s 144 DP (Female)9,07236.000.50
NV Paladin HD2 224Gb/s 72 DP (Male)18,14472.001.00
NV Paladin HD2 224Gb/s 72 DP (Female)18,14472.001.00
NV 224Gb/s SkewClear EXD Gen 2 Cable1,306,3685,184.0072.00
NVL Spine Chassis (NvLink 5)5042.000.03

Backend network

6 rows
Assigned blockDefault
GB300 - NVL72 - CX8 - 3L - ETH - 7700R4C - META
BackendXPU: GB300 NVL726 linesshared by 1 SKU

Backend Parts Summary

6
ItemQty/ClusterQty/ServerAttach/XPU
Generic 800G DR8117,568466.546.48
Generic 800G Single Mode18,14472.001.00
Generic 400G Single Mode81,280322.544.48
ConnectX-8 NIC - 800G18,14472.001.00
Arista 14.4T DSF Leaf (7700R4C)1,0084.000.06
Arista 102.4T DSF Spine (7720R4)5762.290.03

Frontend network

11 rows
Assigned blockDefault
GB300 - NVL72 - Minipack-3 - META
FrontendXPU: GB300 NVL7211 linesshared by 4 SKUs

Frontend Parts Summary

11
ItemQty/ClusterQty/ServerAttach/XPU
Minipack-3 OCP Rack 51.2T32710.0180
Minipack-1 OCP Rack 12.8T100.0001
WhiteBox Tomahawk 2 6.4T3200.0018
Generic 1GbE Ethernet26610.0147
Generic 800G DR810,536420.5807
Generic 400G DR410,481420.5777
Generic 100G DR4 QSFP284,651180.2563
Generic 800G Single Mode14,420570.7947
Generic 400G Single Mode7400.0041
Generic 100G Single Mode2,07280.1142
RJ45 Cables12,787510.7048

Compute Tray Networking Content

3 rows
Assigned blockDefault
GB300 - NVL72 - Generic
Compute TrayXPU: GB300 NVL723 linesshared by 20 SKUs

Compute Tray Parts Summary

3
ItemQty/ClusterQty/ServerAttach/XPU
NV MCIO PCIe x16 Connector9,07236.000.50
NV MCIO PCIe x16 Cable9,07236.000.50
NV DensiLink OverPass to OSFP Cage18,14472.001.00
2026 share
Nvidia NVSwitch 5.0 (NVLink 5)Σ 100%
%
NV 2 UltraPass OverPass 144 DP 224Gb/sΣ 100%
%
NV Paladin HD2 224Gb/s 144 DP (Male)Σ 100%
%
NV Paladin HD2 224Gb/s 144 DP (Female)Σ 100%
%
NV Paladin HD2 224Gb/s 72 DP (Male)Σ 100%
%
NV Paladin HD2 224Gb/s 72 DP (Female)Σ 100%
%
NV 224Gb/s SkewClear EXD Gen 2 CableΣ 100%
%
NVL Spine Chassis (NvLink 5)Σ 100%
%
ItemUnit CostQuantityQuantity (per Server)Quantity (per XPU)Extended Price for ClusterExtended Price per ServerPower (W) per UnitExtended Power (W) per ClusterExtended Power (W) per ServerDevice TypeHyperscalerVendorManufacturerComponentSpeedSerDes SpeedProtocolTechnologyXPUNetworkTab Name
Per-server cost: $166,764.00
$3,200.004,53618.000.25$14,515,200.00$57,600.00407 W1,847,966 W7,333 WScale-Up SwitchMetaNvidiaDevice LevelNVLinkGB300Scale-UpMETA-GB300-CX8-DSF-AR-18k
$720.009,07236.000.50$6,531,840.00$25,920.000 W0 W0 WBackplaneMetaNvidiaAmphenolWhite LabelGB300Scale-UpMETA-GB300-CX8-DSF-AR-18k
$576.009,07236.000.50$5,225,472.00$20,736.000 W0 W0 WBackplaneMetaNvidiaAmphenolWhite Label224GNVLinkGB300Scale-UpMETA-GB300-CX8-DSF-AR-18k
$288.009,07236.000.50$2,612,736.00$10,368.000 W0 W0 WBackplaneMetaNvidiaAmphenolWhite Label224GNVLinkGB300Scale-UpMETA-GB300-CX8-DSF-AR-18k
$288.0018,14472.001.00$5,225,472.00$20,736.000 W0 W0 WBackplaneMetaNvidiaAmphenolWhite Label224GNVLinkGB300Scale-UpMETA-GB300-CX8-DSF-AR-18k
$144.0018,14472.001.00$2,612,736.00$10,368.000 W0 W0 WBackplaneMetaNvidiaAmphenolWhite Label224GNVLinkGB300Scale-UpMETA-GB300-CX8-DSF-AR-18k
$4.001,306,3685,184.0072.00$5,225,472.00$20,736.000 W0 W0 WBackplaneMetaNvidiaAmphenolWhite Label224GNVLinkGB300Scale-UpMETA-GB300-CX8-DSF-AR-18k
$150.005042.000.03$75,600.00$300.000 W0 W0 WBackplaneMetaOthersOthersDevice LevelNVLinkGB300Scale-UpMETA-GB300-CX8-DSF-AR-18k
Per-server cost: $436,052.00
$500.00117,568466.546.48$58,784,000.00$233,269.8416 W1,881,088 W7,465 WTransceiverMetaAAOIDevice Level112GEthernetFully RetimedGB300BackendMETA-GB300-CX8-DSF-AR-18k
$180.0018,14472.001.00$3,265,920.00$12,960.000 W0 W0 WFiberMetaCorningDevice LevelGB300BackendMETA-GB300-CX8-DSF-AR-18k
$130.0081,280322.544.48$10,566,400.00$41,930.160 W0 W0 WFiberMetaAmphenolDevice LevelGB300BackendMETA-GB300-CX8-DSF-AR-18k
$1,500.0018,1444.001.00$27,216,000.00$6,000.0075 W1,360,800 W300 WNICMetaNvidiaDevice LevelGB300BackendMETA-GB300-CX8-DSF-AR-18k
$15,000.001,0084.000.06$15,120,000.00$60,000.00593 W597,744 W2,372 WSwitchMetaAristaDevice LevelGB300BackendMETA-GB300-CX8-DSF-AR-18k
$35,827.755762.290.03$20,636,784.69$81,892.001,400 W806,400 W3,200 WSwitchMetaAristaDevice LevelGB300BackendMETA-GB300-CX8-DSF-AR-18k
Per-server cost: $77,626.54
$25,200.003271.300.02$8,232,840.00$32,670.001,200 W392,040 W1,556 WSwitchMetaAcctonDevice LevelGB300FrontendMETA-GB300-CX8-DSF-AR-18k
$5,000.0010.000.00$4,500.00$17.86450 W405 W2 WSwitchMetaCelesticaDevice LevelGB300FrontendMETA-GB300-CX8-DSF-AR-18k
$3,072.57320.130.00$99,551.30$395.04250 W8,100 W32 WSwitchMetaAcctonDevice LevelGB300FrontendMETA-GB300-CX8-DSF-AR-18k
$350.002661.060.01$93,240.00$370.00100 W26,640 W106 WSwitchMetaAcctonDevice LevelGB300FrontendMETA-GB300-CX8-DSF-AR-18k
$500.0010,53641.810.58$5,268,150.00$20,905.3616 W168,581 W669 WTransceiverMetaAAOIDevice Level112GEthernetFully RetimedGB300FrontendMETA-GB300-CX8-DSF-AR-18k
$260.0010,48141.590.58$2,725,164.00$10,814.1410 W104,814 W416 WTransceiverMetaAAOIDevice Level112GEthernetFully RetimedGB300FrontendMETA-GB300-CX8-DSF-AR-18k
$54.004,65118.460.26$251,164.80$996.693 W13,954 W55 WTransceiverMetaAAOIDevice Level28GEthernetFully RetimedGB300FrontendMETA-GB300-CX8-DSF-AR-18k
$180.0014,42057.220.79$2,595,564.00$10,299.860 W0 W0 WFiberMetaCorningDevice LevelGB300FrontendMETA-GB300-CX8-DSF-AR-18k
$130.00740.290.00$9,594.00$38.070 W0 W0 WFiberMetaAmphenolDevice LevelGB300FrontendMETA-GB300-CX8-DSF-AR-18k
$130.002,0728.220.11$269,334.00$1,068.790 W0 W0 WFiberMetaCorningDevice LevelGB300FrontendMETA-GB300-CX8-DSF-AR-18k
$1.0012,78750.740.70$12,787.20$50.740 W0 W0 WCableMetaAmphenolDevice LevelGB300FrontendMETA-GB300-CX8-DSF-AR-18k
Per-server cost: $4,005.00
$1.259,07236.000.50$11,340.00$45.000 W0 W0 WConnectorMetaAmphenolAmphenolWhite LabelGB300Compute TrayMETA-GB300-CX8-DSF-AR-18k
$35.009,07236.000.50$317,520.00$1,260.000 W0 W0 WCableMetaAmphenolAmphenolWhite LabelGB300Compute TrayMETA-GB300-CX8-DSF-AR-18k
$37.5018,14472.001.00$680,400.00$2,700.000 W0 W0 WCableMetaAmphenolAmphenolWhite LabelGB300Compute TrayMETA-GB300-CX8-DSF-AR-18k
By fabric
Total Scale-Up$42,024,528.00$166,764.001,847,966 W7,333 W
Total Backend$135,589,104.69$436,052.004,646,032 W13,337 W
Total Frontend$19,561,889.30$77,626.54714,533 W2,835 W
Total Compute Tray$1,009,260.00$4,005.000 W0 W
Grand Total Cluster Networking$198,184,781.99$684,447.557,208,532 W23,505 W
By component
Total Transceivers$67,028,478.80$265,986.032,168,436 W8,605 W
Total Switches$44,186,915.99$175,344.901,831,329 W7,267 W
Total Fiber$16,706,812.00$66,296.870 W0 W
Total Cables$1,010,707.20$4,010.740 W0 W
Total Connectors$11,340.00$45.000 W0 W
Total NICs$27,216,000.00$6,000.001,360,800 W300 W