Live DB — analyst tables
Test
Oracle 73728 GB300 CX-8 Hyperscaler Ethernet Cluster Configuration
OCI-GB300-CX8-AR-Eth-3L
Oracle · GB300 · CX-8
Rack type
NVL72
Cluster / location
Default Neocloud GB300 SpectrumX Cluster
Buyer profile
Hyperscaler
Networking type
Ethernet
Number of XPUs
73,728
NIC used
CX-8
NICs / XPU
1
Scale-out BW / XPU
800G
XPU / server
72
Scale-up network
8 rows
Assigned blockDefault
GB300 - NVL72
Scale-UpXPU: GB300 NVL728 linesshared by 22 SKUs
Scale-Up Parts Summary
8
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia NVSwitch 5.0 (NVLink 5) | 18,432 | 18.00 | 0.25 |
| NV 2 UltraPass OverPass 144 DP 224Gb/s | 36,864 | 36.00 | 0.50 |
| NV Paladin HD2 224Gb/s 144 DP (Male) | 36,864 | 36.00 | 0.50 |
| NV Paladin HD2 224Gb/s 144 DP (Female) | 36,864 | 36.00 | 0.50 |
| NV Paladin HD2 224Gb/s 72 DP (Male) | 73,728 | 72.00 | 1.00 |
| NV Paladin HD2 224Gb/s 72 DP (Female) | 73,728 | 72.00 | 1.00 |
| NV 224Gb/s SkewClear EXD Gen 2 Cable | 5,308,416 | 5,184.00 | 72.00 |
| NVL Spine Chassis (NvLink 5) | 2,048 | 2.00 | 0.03 |
Backend network
5 rows
Assigned blockDefault
GB300 - NVL72 - CX8 - 3L - ETH - TH5 - OCI
BackendXPU: GB300 NVL725 linesshared by 1 SKU
Backend Parts Summary
5
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Credo 800G ZF Optics | 147,456 | 144.00 | 2.00 |
| Generic 800G Single Mode | 221,184 | 216.00 | 3.00 |
| Generic 800G DR8 | 294,912 | 288.00 | 4.00 |
| ConnectX-8 NIC - 800G | 73,728 | 72.00 | 1.00 |
| Arista Tomahawk 5 51.2T (7060X6-64PE) | 7,552 | 7.38 | 0.10 |
Frontend network
11 rows
Assigned blockDefault
GB300 - NVL72 - Arista TH5 - Generic
FrontendXPU: GB300 NVL7211 linesshared by 3 SKUs
Frontend Parts Summary
11
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Arista Tomahawk 5 51.2T (7060X6-64PE) | 1,573 | 2 | 0.0213 |
| Arista Tomahawk 3 12.8T (7050PX4-32S) | 7 | 0 | 0.0001 |
| Arista Tomahawk 2 6.4T (7050CX3-32S) | 234 | 0 | 0.0032 |
| Arista Ethernet 1GbE (7048-A) | 1,924 | 2 | 0.0261 |
| Generic 800G DR8 | 76,114 | 74 | 1.0324 |
| Generic 400G DR4 | 75,717 | 74 | 1.0270 |
| Generic 100G DR4 QSFP28 | 33,600 | 33 | 0.4557 |
| Generic 800G Single Mode | 104,168 | 102 | 1.4129 |
| Generic 400G Single Mode | 533 | 1 | 0.0072 |
| Generic 100G Single Mode | 14,967 | 15 | 0.2030 |
| RJ45 Cables | 92,375 | 90 | 1.2529 |
Compute Tray Networking Content
3 rows
Assigned blockDefault
GB300 - NVL72 - Generic
Compute TrayXPU: GB300 NVL723 linesshared by 20 SKUs
Compute Tray Parts Summary
3
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| NV MCIO PCIe x16 Connector | 36,864 | 36.00 | 0.50 |
| NV MCIO PCIe x16 Cable | 36,864 | 36.00 | 0.50 |
| NV DensiLink OverPass to OSFP Cage | 73,728 | 72.00 | 1.00 |
2026 share
Nvidia NVSwitch 5.0 (NVLink 5)Σ 100%
%
NV 2 UltraPass OverPass 144 DP 224Gb/sΣ 100%
%
NV Paladin HD2 224Gb/s 144 DP (Male)Σ 100%
%
NV Paladin HD2 224Gb/s 144 DP (Female)Σ 100%
%
NV Paladin HD2 224Gb/s 72 DP (Male)Σ 100%
%
NV Paladin HD2 224Gb/s 72 DP (Female)Σ 100%
%
NV 224Gb/s SkewClear EXD Gen 2 CableΣ 100%
%
NVL Spine Chassis (NvLink 5)Σ 100%
%
| Item | Unit Cost | Quantity | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Per-server cost: $166,764.00 | |||||||||||||||||||||
| $3,200.00 | 18,432 | 18.00 | 0.25 | $58,982,400.00 | $57,600.00 | 407 W | 7,509,197 W | 7,333 W | Scale-Up Switch | Oracle | Nvidia | — | Device Level | — | — | NVLink | — | GB300 | Scale-Up | OCI-GB300-CX8-AR-Eth-3L | |
| $720.00 | 36,864 | 36.00 | 0.50 | $26,542,080.00 | $25,920.00 | 0 W | 0 W | 0 W | Backplane | Oracle | Nvidia | Amphenol | White Label | — | — | — | — | GB300 | Scale-Up | OCI-GB300-CX8-AR-Eth-3L | |
| $576.00 | 36,864 | 36.00 | 0.50 | $21,233,664.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Oracle | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB300 | Scale-Up | OCI-GB300-CX8-AR-Eth-3L | |
| $288.00 | 36,864 | 36.00 | 0.50 | $10,616,832.00 | $10,368.00 | 0 W | 0 W | 0 W | Backplane | Oracle | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB300 | Scale-Up | OCI-GB300-CX8-AR-Eth-3L | |
| $288.00 | 73,728 | 72.00 | 1.00 | $21,233,664.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Oracle | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB300 | Scale-Up | OCI-GB300-CX8-AR-Eth-3L | |
| $144.00 | 73,728 | 72.00 | 1.00 | $10,616,832.00 | $10,368.00 | 0 W | 0 W | 0 W | Backplane | Oracle | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB300 | Scale-Up | OCI-GB300-CX8-AR-Eth-3L | |
| $4.00 | 5,308,416 | 5,184.00 | 72.00 | $21,233,664.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Oracle | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB300 | Scale-Up | OCI-GB300-CX8-AR-Eth-3L | |
| $150.00 | 2,048 | 2.00 | 0.03 | $307,200.00 | $300.00 | 0 W | 0 W | 0 W | Backplane | Oracle | Others | Others | Device Level | — | — | NVLink | — | GB300 | Scale-Up | OCI-GB300-CX8-AR-Eth-3L | |
Per-server cost: $464,870.00 | |||||||||||||||||||||
| $585.00 | 147,456 | 144.00 | 2.00 | $86,261,760.00 | $84,240.00 | 15 W | 2,211,840 W | 2,160 W | Transceiver | Oracle | Credo | — | Device Level | — | — | Ethernet | Fully Retimed | GB300 | Backend | OCI-GB300-CX8-AR-Eth-3L | |
| $180.00 | 221,184 | 216.00 | 3.00 | $39,813,120.00 | $38,880.00 | 0 W | 0 W | 0 W | Fiber | Oracle | Corning | — | Device Level | — | — | — | — | GB300 | Backend | OCI-GB300-CX8-AR-Eth-3L | |
| $500.00 | 294,912 | 288.00 | 4.00 | $147,456,000.00 | $144,000.00 | 16 W | 4,718,592 W | 4,608 W | Transceiver | Oracle | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | GB300 | Backend | OCI-GB300-CX8-AR-Eth-3L | |
| $1,500.00 | 73,728 | 4.00 | 1.00 | $110,592,000.00 | $6,000.00 | 75 W | 5,529,600 W | 300 W | NIC | Oracle | Nvidia | — | Device Level | — | — | — | — | GB300 | Backend | OCI-GB300-CX8-AR-Eth-3L | |
| $26,000.00 | 7,552 | 7.38 | 0.10 | $196,352,000.00 | $191,750.00 | 1,200 W | 9,062,400 W | 8,850 W | Switch | Oracle | Arista | — | Device Level | — | — | — | — | GB300 | Backend | OCI-GB300-CX8-AR-Eth-3L | |
Per-server cost: $70,650.07 | |||||||||||||||||||||
| $26,000.00 | 885 | 0.86 | 0.01 | $23,010,742.85 | $22,471.43 | 1,200 W | 1,062,034 W | 1,037 W | Switch | Oracle | Arista | — | Device Level | — | — | — | — | GB300 | Frontend | OCI-GB300-CX8-AR-Eth-3L | |
| $15,000.00 | 4 | 0.00 | 0.00 | $54,857.15 | $53.57 | 630 W | 2,304 W | 2 W | Switch | Oracle | Arista | — | Device Level | — | — | — | — | GB300 | Frontend | OCI-GB300-CX8-AR-Eth-3L | |
| $11,000.00 | 132 | 0.13 | 0.00 | $1,448,228.57 | $1,414.29 | 250 W | 32,914 W | 32 W | Switch | Oracle | Arista | — | Device Level | — | — | — | — | GB300 | Frontend | OCI-GB300-CX8-AR-Eth-3L | |
| $2,400.00 | 1,083 | 1.06 | 0.01 | $2,598,034.29 | $2,537.14 | 150 W | 162,377 W | 159 W | Switch | Oracle | Arista | — | Device Level | — | — | — | — | GB300 | Frontend | OCI-GB300-CX8-AR-Eth-3L | |
| $500.00 | 42,814 | 41.81 | 0.58 | $21,407,085.71 | $20,905.36 | 16 W | 685,027 W | 669 W | Transceiver | Oracle | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | GB300 | Frontend | OCI-GB300-CX8-AR-Eth-3L | |
| $260.00 | 42,591 | 41.59 | 0.58 | $11,073,682.29 | $10,814.14 | 10 W | 425,911 W | 416 W | Transceiver | Oracle | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | GB300 | Frontend | OCI-GB300-CX8-AR-Eth-3L | |
| $54.00 | 18,900 | 18.46 | 0.26 | $1,020,606.17 | $996.69 | 3 W | 56,700 W | 55 W | Transceiver | Oracle | AAOI | — | Device Level | — | 28G | Ethernet | Fully Retimed | GB300 | Frontend | OCI-GB300-CX8-AR-Eth-3L | |
| $180.00 | 58,595 | 57.22 | 0.79 | $10,547,053.71 | $10,299.86 | 0 W | 0 W | 0 W | Fiber | Oracle | Corning | — | Device Level | — | — | — | — | GB300 | Frontend | OCI-GB300-CX8-AR-Eth-3L | |
| $130.00 | 300 | 0.29 | 0.00 | $38,985.14 | $38.07 | 0 W | 0 W | 0 W | Fiber | Oracle | Amphenol | — | Device Level | — | — | — | — | GB300 | Frontend | OCI-GB300-CX8-AR-Eth-3L | |
| $130.00 | 8,419 | 8.22 | 0.11 | $1,094,436.57 | $1,068.79 | 0 W | 0 W | 0 W | Fiber | Oracle | Corning | — | Device Level | — | — | — | — | GB300 | Frontend | OCI-GB300-CX8-AR-Eth-3L | |
| $1.00 | 51,961 | 50.74 | 0.70 | $51,960.69 | $50.74 | 0 W | 0 W | 0 W | Cable | Oracle | Amphenol | — | Device Level | — | — | — | — | GB300 | Frontend | OCI-GB300-CX8-AR-Eth-3L | |
Per-server cost: $4,005.00 | |||||||||||||||||||||
| $1.25 | 36,864 | 36.00 | 0.50 | $46,080.00 | $45.00 | 0 W | 0 W | 0 W | Connector | Oracle | Amphenol | Amphenol | White Label | — | — | — | — | GB300 | Compute Tray | OCI-GB300-CX8-AR-Eth-3L | |
| $35.00 | 36,864 | 36.00 | 0.50 | $1,290,240.00 | $1,260.00 | 0 W | 0 W | 0 W | Cable | Oracle | Amphenol | Amphenol | White Label | — | — | — | — | GB300 | Compute Tray | OCI-GB300-CX8-AR-Eth-3L | |
| $37.50 | 73,728 | 72.00 | 1.00 | $2,764,800.00 | $2,700.00 | 0 W | 0 W | 0 W | Cable | Oracle | Amphenol | Amphenol | White Label | — | — | — | — | GB300 | Compute Tray | OCI-GB300-CX8-AR-Eth-3L | |
| By fabric | |||||||||||||||||||||
| Total Scale-Up | $170,766,336.00 | $166,764.00 | 7,509,197 W | 7,333 W | |||||||||||||||||
| Total Backend | $580,474,880.00 | $464,870.00 | 21,522,432 W | 15,918 W | |||||||||||||||||
| Total Frontend | $72,345,673.14 | $70,650.07 | 2,427,268 W | 2,370 W | |||||||||||||||||
| Total Compute Tray | $4,101,120.00 | $4,005.00 | 0 W | 0 W | |||||||||||||||||
| Grand Total Cluster Networking | $827,688,009.14 | $706,289.07 | 31,458,896 W | 25,622 W | |||||||||||||||||
| By component | |||||||||||||||||||||
| Total Transceivers | $267,219,134.17 | $260,956.19 | 8,098,070 W | 7,908 W | |||||||||||||||||
| Total Switches | $223,463,862.85 | $218,226.43 | 10,322,030 W | 10,080 W | |||||||||||||||||
| Total Fiber | $51,493,595.43 | $50,286.71 | 0 W | 0 W | |||||||||||||||||
| Total Cables | $4,107,000.69 | $4,010.74 | 0 W | 0 W | |||||||||||||||||
| Total Connectors | $46,080.00 | $45.00 | 0 W | 0 W | |||||||||||||||||
| Total NICs | $110,592,000.00 | $6,000.00 | 5,529,600 W | 300 W | |||||||||||||||||