Live DB — analyst tables
Test
Default Hyperscaler 131072 VR200 CX-9 Hyperscaler Spectrum X Cluster Configuration

HS-VR200-CX9-SX6-SN6800-CPO

Default Hyperscaler · VR200 · CX-9

Rack type
NVL72
Cluster / location
Default VR200
Buyer profile
Hyperscaler
Networking type
Spectrum X
Number of XPUs
131,072
NIC used
CX-9
NICs / XPU
2
Scale-out BW / XPU
1.6T
XPU / server
72

Scale-up network

7 rows
Assigned blockDefault
VR200 - NVL72
Scale-UpXPU: VR200 NVL727 linesshared by 31 SKUs

Scale-Up Parts Summary

7
ItemQty/ClusterQty/ServerAttach/XPU
Nvidia NVSwitch 6.0 (NVLink 6)65,53636.000.50
NV Paladin HD2 224Gb/s 144 Bidi (Male)65,53636.000.50
NV Paladin HD2 224Gb/s 144 Bidi (Female)65,53636.000.50
NV Paladin HD2 224Gb/s 72 Bidi (Male)131,07272.001.00
NV Paladin HD2 224Gb/s 72 Bidi (Female)9,437,1845,184.0072.00
NV 224Gb/s SkewClear EXD Gen 2 Bidi Cable9,437,1845,184.0072.00
NVL Spine Chassis (NvLink 6)3,6412.000.03

Backend network

4 rows
Assigned blockDefault
VR200 - NVL72 - CX9 - 2L - ETH - SN6800 - Generic
BackendXPU: VR200 NVL724 linesshared by 2 SKUs

Backend Parts Summary

4
ItemQty/ClusterQty/ServerAttach/XPU
Nvidia LinkX 800G DR4262,144144.002.00
Nvidia LinkX 800G Single Mode524,288288.004.00
ConnectX-9 NIC - 800G262,144144.002.00
Spectrum-6 409.6T CPO (SN6800)1,5360.840.01

Frontend network

11 rows
Assigned blockDefault
VR200 - NVL72 - SN6600 - Generic - 2
FrontendXPU: VR200 NVL7211 linesshared by 8 SKUs

Frontend Parts Summary

11
ItemQty/ClusterQty/ServerAttach/XPU
Spectrum-6 102.4T x1600 (SN6600)1,57310.0120
Spectrum-4 25.6T (SN5400)700.0001
Spectrum-3 12.8T (SN4700)23400.0018
Spectrum-2 1GbE (SN2201)1,92410.0147
Nvidia LinkX 1.6T DR8 (SiPho)76,114420.5807
Nvidia LinkX 800G DR475,717420.5777
Nvidia LinkX 200G SR433,600180.2563
Nvidia LinkX 800G Multimode104,168570.7947
Nvidia LinkX 400G Multimode53300.0041
Nvidia LinkX 200G Multimode14,96780.1142
RJ45 Cables92,375510.7048

Compute Tray Networking Content

4 rows
Assigned blockDefault
VR200 - NVL72 - Generic
Compute TrayXPU: VR200 NVL724 linesshared by 31 SKUs

Compute Tray Parts Summary

4
ItemQty/ClusterQty/ServerAttach/XPU
NV Paladin Board to Board 32 Pin 4p8c (Male)131,07272.001.00
NV Paladin Board to Board 64 Pin 4p16c (Male)524,288288.004.00
NV Paladin Board to Board 32 Pin 4p8c (Female)131,07272.001.00
NV Paladin Board to Board 64 Pin 4p16c (Female)524,288288.004.00
2026 share
Nvidia NVSwitch 6.0 (NVLink 6)Σ 100%
%
NV Paladin HD2 224Gb/s 144 Bidi (Male)Σ 100%
%
NV Paladin HD2 224Gb/s 144 Bidi (Female)Σ 100%
%
NV Paladin HD2 224Gb/s 72 Bidi (Male)Σ 100%
%
NV Paladin HD2 224Gb/s 72 Bidi (Female)Σ 100%
%
NV 224Gb/s SkewClear EXD Gen 2 Bidi CableΣ 100%
%
ItemUnit CostQuantityQuantity (per Server)Quantity (per XPU)Extended Price for ClusterExtended Price per ServerPower (W) per UnitExtended Power (W) per ClusterExtended Power (W) per ServerDevice TypeHyperscalerVendorManufacturerComponentSpeedSerDes SpeedProtocolTechnologyXPUNetworkTab Name
Per-server cost: $963,522.00
$4,000.0065,53636.000.50$262,144,000.00$144,000.00650 W42,598,400 W23,400 WScale-Up SwitchDefault HyperscalerNvidiaDevice LevelNVLinkVR200Scale-UpHS-VR200-CX9-SX6-SN6800-CPO
$576.0065,53636.000.50$37,748,736.00$20,736.000 W0 W0 WBackplaneDefault HyperscalerNvidiaAmphenolWhite Label224GNVLinkVR200Scale-UpHS-VR200-CX9-SX6-SN6800-CPO
$288.0065,53636.000.50$18,874,368.00$10,368.000 W0 W0 WBackplaneDefault HyperscalerNvidiaAmphenolWhite Label224GNVLinkVR200Scale-UpHS-VR200-CX9-SX6-SN6800-CPO
$288.00131,07272.001.00$37,748,736.00$20,736.000 W0 W0 WBackplaneDefault HyperscalerNvidiaAmphenolWhite Label224GNVLinkVR200Scale-UpHS-VR200-CX9-SX6-SN6800-CPO
$144.009,437,1845,184.0072.00$1,358,954,496.00$746,496.000 W0 W0 WBackplaneDefault HyperscalerNvidiaAmphenolWhite Label224GNVLinkVR200Scale-UpHS-VR200-CX9-SX6-SN6800-CPO
$4.009,437,1845,184.0072.00$37,748,736.00$20,736.000 W0 W0 WBackplaneDefault HyperscalerNvidiaAmphenolWhite Label224GNVLinkVR200Scale-UpHS-VR200-CX9-SX6-SN6800-CPO
$225.003,6412.000.03$819,200.00$450.000 W0 W0 WBackplaneDefault HyperscalerOthersOthersDevice LevelNVLinkVR200Scale-UpHS-VR200-CX9-SX6-SN6800-CPO
Per-server cost: $578,069.13
$1,511.63262,144144.002.00$396,264,186.05$217,674.4217 W4,456,448 W2,448 WTransceiverDefault HyperscalerNvidiaCoherent, Eoptolink, Innolight, MellanoxWhite Label224GInfiniBandFully RetimedVR200BackendHS-VR200-CX9-SX6-SN6800-CPO
$450.00524,288288.004.00$235,929,600.00$129,600.000 W0 W0 WFiberDefault HyperscalerOthersWhite LabelVR200BackendHS-VR200-CX9-SX6-SN6800-CPO
$1,650.00262,1448.002.00$432,537,600.00$13,200.0090 W23,592,960 W720 WNICDefault HyperscalerNvidiaDevice LevelVR200BackendHS-VR200-CX9-SX6-SN6800-CPO
$257,890.031,5360.840.01$396,119,080.96$217,594.7112,615 W19,376,811 W10,644 WSwitchDefault HyperscalerNvidiaDevice LevelEthernetCPOVR200BackendHS-VR200-CX9-SX6-SN6800-CPO
Per-server cost: $207,693.51
$32,526.911,5730.860.01$51,177,326.94$28,112.551,344 W2,113,846 W1,161 WSwitchDefault HyperscalerNvidiaDevice LevelEthernetVR200FrontendHS-VR200-CX9-SX6-SN6800-CPO
$15,000.0070.000.00$97,523.81$53.57670 W4,356 W2 WSwitchDefault HyperscalerNvidiaDevice LevelEthernetVR200FrontendHS-VR200-CX9-SX6-SN6800-CPO
$21,600.002340.130.00$5,055,634.29$2,777.14630 W147,456 W81 WSwitchDefault HyperscalerNvidiaDevice LevelEthernetVR200FrontendHS-VR200-CX9-SX6-SN6800-CPO
$2,400.001,9241.060.01$4,618,727.62$2,537.14150 W288,670 W159 WSwitchDefault HyperscalerNvidiaDevice LevelEthernetVR200FrontendHS-VR200-CX9-SX6-SN6800-CPO
$1,723.4076,11441.810.58$131,175,333.71$72,056.7622 W1,674,510 W920 WTransceiverDefault HyperscalerNvidiaCoherent, Eoptolink, Innolight, MellanoxWhite Label224GInfiniBandFully RetimedVR200FrontendHS-VR200-CX9-SX6-SN6800-CPO
$1,511.6375,71741.590.58$114,456,664.45$62,872.9217 W1,287,197 W707 WTransceiverDefault HyperscalerNvidiaCoherent, Eoptolink, Innolight, MellanoxWhite Label224GInfiniBandFully RetimedVR200FrontendHS-VR200-CX9-SX6-SN6800-CPO
$325.0033,60018.460.26$10,920,066.03$5,998.575 W168,001 W92 WTransceiverDefault HyperscalerNvidiaMellanox, OthersWhite Label56GInfiniBandFully RetimedVR200FrontendHS-VR200-CX9-SX6-SN6800-CPO
$525.00104,16857.220.79$54,688,426.67$30,041.250 W0 W0 WFiberDefault HyperscalerOthersWhite LabelVR200FrontendHS-VR200-CX9-SX6-SN6800-CPO
$375.005330.290.00$199,923.81$109.820 W0 W0 WFiberDefault HyperscalerOthersWhite LabelVR200FrontendHS-VR200-CX9-SX6-SN6800-CPO
$375.0014,9678.220.11$5,612,495.24$3,083.040 W0 W0 WFiberDefault HyperscalerOthersWhite LabelVR200FrontendHS-VR200-CX9-SX6-SN6800-CPO
$1.0092,37550.740.70$92,374.55$50.740 W0 W0 WCableDefault HyperscalerAmphenolDevice LevelVR200FrontendHS-VR200-CX9-SX6-SN6800-CPO
Per-server cost: $62,208.00
$64.00131,07272.001.00$8,388,608.00$4,608.000 W0 W0 WMidplaneDefault HyperscalerNvidiaAmphenolWhite Label224GNVLinkVR200Compute TrayHS-VR200-CX9-SX6-SN6800-CPO
$128.00524,288288.004.00$67,108,864.00$36,864.000 W0 W0 WMidplaneDefault HyperscalerNvidiaAmphenolWhite Label224GNVLinkVR200Compute TrayHS-VR200-CX9-SX6-SN6800-CPO
$32.00131,07272.001.00$4,194,304.00$2,304.000 W0 W0 WMidplaneDefault HyperscalerNvidiaAmphenolWhite Label224GNVLinkVR200Compute TrayHS-VR200-CX9-SX6-SN6800-CPO
$64.00524,288288.004.00$33,554,432.00$18,432.000 W0 W0 WMidplaneDefault HyperscalerNvidiaAmphenolWhite Label224GNVLinkVR200Compute TrayHS-VR200-CX9-SX6-SN6800-CPO
By fabric
Total Scale-Up$1,754,038,272.00$963,522.0042,598,400 W23,400 W
Total Backend$1,460,850,467.01$578,069.1347,426,219 W13,812 W
Total Frontend$378,094,497.12$207,693.515,684,037 W3,122 W
Total Compute Tray$113,246,208.00$62,208.000 W0 W
Grand Total Cluster Networking$3,706,229,444.13$1,811,492.6495,708,655 W40,334 W
By component
Total Transceivers$652,816,250.25$358,602.687,586,156 W4,167 W
Total Switches$457,068,293.61$251,075.1121,931,139 W12,047 W
Total Fiber$296,430,445.71$162,834.110 W0 W
Total Cables$92,374.55$50.740 W0 W
Total Connectors
Total NICs$432,537,600.00$13,200.0023,592,960 W720 W