Live DB — analyst tables
Test
NG-Feynman NVL1152-CX10-SN6800-4R CPO
NG-Feynman NVL1152-CX10-SN6800-4R CPO
Neocloud Giant · Feynman · CX10
Rack type
Kyber NVL1152
Cluster / location
Neocloud Giant Kyber NVL 1152 SN6800 (CPO)
Buyer profile
Neocloud Giant
Networking type
Ethernet
Number of XPUs
131,072
NIC used
CX10
NICs / XPU
3
Scale-out BW / XPU
4.8T
XPU / server
1,152
Scale-up network
8 rows
Assigned blockDefault
Feynman - Kyber NVL1152
Scale-UpXPU: Feynman Kyber NVL11528 linesshared by 11 SKUs
Scale-Up Parts Summary
8
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia NVSwitch 8.0 (NVLink 8) | 65,536 | 576.00 | 0.50 |
| NV 3.2T Optical Engine (OE) for NVLink Switch side CPO | 688,128 | 6,048.00 | 5.25 |
| NV 1.6T 8 Fiber Pair FAU | 2,752,512 | 24,192.00 | 21.00 |
| NV External Laser Source (ELS) 8 LD 6.4T for NVLink CPO Switch | 344,064 | 3,024.00 | 2.63 |
| NV Sentry HD 448Gb/s 144DP (Male) | 262,144 | 2,304.00 | 2.00 |
| NV Sentry HD 448Gb/s 144DP (Female) | 262,144 | 2,304.00 | 2.00 |
| NVL Blade Column Spine Chassis (NvLink 7) | 1,820 | 16.00 | 0.01 |
| NVL Kyber Canister Midplane PCB (NvLink 7) | 910 | 8.00 | 0.01 |
Backend network
4 rows
Assigned blockDefault
Feynman - Kyber NVL1152 - CX10 - 2L - ETH - SN6800 - Generic
BackendXPU: Feynman Kyber NVL11524 linesshared by 2 SKUs
Backend Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia LinkX 800G DR4 | 786,432 | 6,912.00 | 6.00 |
| Nvidia LinkX 800G Single Mode | 1,572,864 | 13,824.00 | 12.00 |
| ConnectX-10 NIC - 1.6T | 393,216 | 3,456.00 | 3.00 |
| Spectrum-6 409.6T CPO (SN6800) | 4,608 | 40.50 | 0.04 |
Frontend network
11 rows
Assigned blockDefault
Feynman - Kyber NVL1152 - SN6600 - Generic
FrontendXPU: Feynman Kyber NVL115211 linesshared by 11 SKUs
Frontend Parts Summary
11
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Spectrum-6 102.4T x1600 (SN6600) | 1,120 | 10 | 0.0085 |
| Spectrum-4 25.6T (SN5400) | 5 | 0 | 0.0000 |
| Spectrum-3 12.8T (SN4700) | 167 | 1 | 0.0013 |
| Spectrum-2 6.4T (SN3700) | 1,370 | 12 | 0.0105 |
| Nvidia LinkX 1.6T DR8 (SiPho) | 54,187 | 476 | 0.4134 |
| Nvidia LinkX 800G DR4 | 53,904 | 474 | 0.4113 |
| Nvidia LinkX 200G SR4 | 23,920 | 210 | 0.1825 |
| Nvidia LinkX 800G Multimode | 74,159 | 652 | 0.5658 |
| Nvidia LinkX 400G Multimode | 380 | 3 | 0.0029 |
| Nvidia LinkX 200G Multimode | 10,655 | 94 | 0.0813 |
| RJ45 Cables | 65,763 | 578 | 0.5017 |
Compute Tray Networking Content
4 rows
Assigned blockDefault
Feynman - Kyber NVL1152 - Generic
Compute TrayXPU: Feynman Kyber NVL11524 linesshared by 11 SKUs
Compute Tray Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| NV Paladin Board to Board 32 Pin 4p8c (Male) | 131,072 | 1,152.00 | 1.00 |
| NV Paladin Board to Board 64 Pin 4p16c (Male) | 524,288 | 4,608.00 | 4.00 |
| NV Paladin Board to Board 32 Pin 4p8c (Female) | 131,072 | 1,152.00 | 1.00 |
| NV Paladin Board to Board 64 Pin 4p16c (Female) | 524,288 | 4,608.00 | 4.00 |
2026 share
RJ45 CablesΣ 100%
%
| Item | Unit Cost | Quantity | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Per-server cost: $24,562,126.86 | |||||||||||||||||||||
| $18,071.43 | 65,536 | 576.00 | 0.50 | $1,184,329,142.83 | $10,409,142.86 | 800 W | 52,428,800 W | 460,800 W | Scale-Up Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | NVLink | — | Feynman | Scale-Up | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
| $400.00 | 688,128 | 6,048.00 | 5.25 | $275,251,200.00 | $2,419,200.00 | 13 W | 8,670,413 W | 76,205 W | — | Neocloud Giant | Others | Others | White Label | — | — | NVLink | — | Feynman | Scale-Up | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
| $160.00 | 2,752,512 | 24,192.00 | 21.00 | $440,401,920.00 | $3,870,720.00 | 0 W | 0 W | 0 W | — | Neocloud Giant | Others | Others | White Label | — | — | NVLink | — | Feynman | Scale-Up | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
| $1,320.00 | 344,064 | 3,024.00 | 2.63 | $454,164,480.00 | $3,991,680.00 | 8 W | 2,752,512 W | 24,192 W | — | Neocloud Giant | Others | Others | White Label | — | — | NVLink | — | Feynman | Scale-Up | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
| $864.00 | 262,144 | 2,304.00 | 2.00 | $226,492,416.00 | $1,990,656.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 448G | NVLink | — | Feynman | Scale-Up | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
| $432.00 | 262,144 | 2,304.00 | 2.00 | $113,246,208.00 | $995,328.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 448G | NVLink | — | Feynman | Scale-Up | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
| $337.50 | 1,820 | 16.00 | 0.01 | $614,400.00 | $5,400.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Others | Others | Device Level | — | — | NVLink | — | Feynman | Scale-Up | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
| $110,000.00 | 910 | 8.00 | 0.01 | $100,124,444.44 | $880,000.00 | 0 W | 0 W | 0 W | Backplane | Neocloud Giant | Others | Others | Device Level | — | — | NVLink | — | Feynman | Scale-Up | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
Per-server cost: $40,142,452.80 | |||||||||||||||||||||
| $1,200.00 | 786,432 | 6,912.00 | 6.00 | $943,718,400.00 | $8,294,400.00 | 17 W | 13,369,344 W | 117,504 W | Transceiver | Neocloud Giant | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | Feynman | Backend | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
| $540.00 | 1,572,864 | 13,824.00 | 12.00 | $849,346,560.00 | $7,464,960.00 | 0 W | 0 W | 0 W | Fiber | Neocloud Giant | Others | — | White Label | — | — | — | — | Feynman | Backend | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
| $3,850.00 | 393,216 | 12.00 | 3.00 | $1,513,881,600.00 | $46,200.00 | 100 W | 39,321,600 W | 1,200 W | NIC | Neocloud Giant | Nvidia | — | Device Level | — | — | — | — | Feynman | Backend | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
| $600,910.93 | 4,608 | 40.50 | 0.04 | $2,768,997,580.80 | $24,336,892.80 | 12,615 W | 58,130,432 W | 510,912 W | Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | Ethernet | CPO | Feynman | Backend | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
Per-server cost: $4,467,960.10 | |||||||||||||||||||||
| $98,000.00 | 1,573 | 13.83 | 0.01 | $154,191,644.45 | $1,355,200.00 | 1,344 W | 2,113,846 W | 18,579 W | Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | Ethernet | — | Feynman | Frontend | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
| $16,500.00 | 7 | 0.06 | 0.00 | $107,276.19 | $942.86 | 670 W | 4,356 W | 38 W | Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | Ethernet | — | Feynman | Frontend | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
| $27,000.00 | 234 | 2.06 | 0.00 | $6,319,542.86 | $55,542.86 | 630 W | 147,456 W | 1,296 W | Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | Ethernet | — | Feynman | Frontend | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
| $14,600.86 | 1,924 | 16.91 | 0.01 | $28,098,909.18 | $246,963.07 | 250 W | 481,117 W | 4,229 W | Switch | Neocloud Giant | Nvidia | — | Device Level | — | — | Ethernet | — | Feynman | Frontend | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
| $1,900.00 | 76,114 | 668.97 | 0.58 | $144,616,756.83 | $1,271,045.71 | 22 W | 1,674,510 W | 14,717 W | Transceiver | Neocloud Giant | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | Feynman | Frontend | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
| $1,200.00 | 75,717 | 665.49 | 0.58 | $90,860,982.86 | $798,582.86 | 17 W | 1,287,197 W | 11,313 W | Transceiver | Neocloud Giant | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | Feynman | Frontend | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
| $341.25 | 33,600 | 295.31 | 0.26 | $11,466,069.33 | $100,776.00 | 5 W | 168,001 W | 1,477 W | Transceiver | Neocloud Giant | Nvidia | Mellanox, Others | White Label | — | 56G | InfiniBand | Fully Retimed | Feynman | Frontend | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
| $630.00 | 104,168 | 915.54 | 0.79 | $65,626,112.00 | $576,792.00 | 0 W | 0 W | 0 W | Fiber | Neocloud Giant | Others | — | White Label | — | — | — | — | Feynman | Frontend | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
| $450.00 | 533 | 4.69 | 0.00 | $239,908.57 | $2,108.57 | 0 W | 0 W | 0 W | Fiber | Neocloud Giant | Others | — | White Label | — | — | — | — | Feynman | Frontend | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
| $450.00 | 14,967 | 131.54 | 0.11 | $6,734,994.29 | $59,194.29 | 0 W | 0 W | 0 W | Fiber | Neocloud Giant | Others | — | White Label | — | — | — | — | Feynman | Frontend | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
| $1.00 | 92,375 | 811.89 | 0.70 | $92,374.55 | $811.89 | 0 W | 0 W | 0 W | Cable | Neocloud Giant | Amphenol | — | Device Level | — | — | — | — | Feynman | Frontend | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
Per-server cost: $995,328.00 | |||||||||||||||||||||
| $64.00 | 131,072 | 1,152.00 | 1.00 | $8,388,608.00 | $73,728.00 | 0 W | 0 W | 0 W | Midplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Feynman | Compute Tray | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
| $128.00 | 524,288 | 4,608.00 | 4.00 | $67,108,864.00 | $589,824.00 | 0 W | 0 W | 0 W | Midplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Feynman | Compute Tray | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
| $32.00 | 131,072 | 1,152.00 | 1.00 | $4,194,304.00 | $36,864.00 | 0 W | 0 W | 0 W | Midplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Feynman | Compute Tray | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
| $64.00 | 524,288 | 4,608.00 | 4.00 | $33,554,432.00 | $294,912.00 | 0 W | 0 W | 0 W | Midplane | Neocloud Giant | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Feynman | Compute Tray | NG-Feynman NVL1152-CX10-SN6800-4R CPO | |
| By fabric | |||||||||||||||||||||
| Total Scale-Up | $2,794,624,211.27 | $24,562,126.86 | 63,851,725 W | 561,197 W | |||||||||||||||||
| Total Backend | $6,075,944,140.80 | $40,142,452.80 | 110,821,376 W | 629,616 W | |||||||||||||||||
| Total Frontend | $508,354,571.10 | $4,467,960.10 | 5,876,484 W | 51,649 W | |||||||||||||||||
| Total Compute Tray | $113,246,208.00 | $995,328.00 | 0 W | 0 W | |||||||||||||||||
| Grand Total Cluster Networking | $9,492,169,131.17 | $70,167,867.75 | 180,549,585 W | 1,242,462 W | |||||||||||||||||
| By component | |||||||||||||||||||||
| Total Transceivers | $1,190,662,209.02 | $10,464,804.57 | 16,499,052 W | 145,011 W | |||||||||||||||||
| Total Switches | $2,957,714,953.47 | $25,995,541.58 | 60,877,208 W | 535,054 W | |||||||||||||||||
| Total Fiber | $921,947,574.86 | $8,103,054.86 | 0 W | 0 W | |||||||||||||||||
| Total Cables | $92,374.55 | $811.89 | 0 W | 0 W | |||||||||||||||||
| Total Connectors | — | — | — | — | |||||||||||||||||
| Total NICs | $1,513,881,600.00 | $46,200.00 | 39,321,600 W | 1,200 W | |||||||||||||||||