Live DB — analyst tables
Test
Default Hyperscaler 131072 Rubin Ultra NVL72 CX-9 Hyperscaler Spectrum X Cluster Configuration
HS-RU NVL72-CX9-SN6800-CPO
Default Hyperscaler · Rubin Ultra · CX-9
Rack type
NVL72
Cluster / location
Default Rubin Ultra
Buyer profile
Hyperscaler
Networking type
Spectrum X
Number of XPUs
131,072
NIC used
CX-9
NICs / XPU
4
Scale-out BW / XPU
3.2T
XPU / server
72
Scale-up network
7 rows
Assigned blockDefault
Rubin Ultra - NVL72
Scale-UpXPU: Rubin Ultra NVL727 linesshared by 11 SKUs
Scale-Up Parts Summary
7
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia NVSwitch 7.0 (NVLink 7) - 28.8T | 65,536 | 36.00 | 0.50 |
| NV Sentry HD 448Gb/s 144DP (Male) | 65,536 | 36.00 | 0.50 |
| NV Sentry HD 448Gb/s 144DP (Female) | 65,536 | 36.00 | 0.50 |
| NV Sentry HD 448Gb/s 72DP (Male) | 131,072 | 72.00 | 1.00 |
| NV Sentry HD 448Gb/s 72DP (Female) | 131,072 | 72.00 | 1.00 |
| NVL Blade Column Spine Chassis (NvLink 7) | 3,641 | 2.00 | 0.03 |
| NV 224Gb/s SkewClear EXD Gen 2 Bidi Cable | 9,437,184 | 5,184.00 | 72.00 |
Backend network
4 rows
Assigned blockDefault
Rubin Ultra - NVL72 - CX9 - 2L - ETH - SN6800 - Generic
BackendXPU: Rubin Ultra NVL724 linesshared by 2 SKUs
Backend Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia LinkX 800G DR4 | 524,288 | 288.00 | 4.00 |
| Nvidia LinkX 800G Single Mode | 1,048,576 | 576.00 | 8.00 |
| ConnectX-9 NIC - 800G | 524,288 | 288.00 | 4.00 |
| Spectrum-6 409.6T CPO (SN6800) | 3,072 | 1.69 | 0.02 |
Frontend network
11 rows
Assigned blockDefault
Rubin Ultra - NVL72 - SN6600 - Generic
FrontendXPU: Rubin Ultra NVL7211 linesshared by 11 SKUs
Frontend Parts Summary
11
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Spectrum-6 102.4T x1600 (SN6600) | 1,120 | 1 | 0.0085 |
| Spectrum-4 25.6T (SN5400) | 5 | 0 | 0.0000 |
| Spectrum-3 12.8T (SN4700) | 167 | 0 | 0.0013 |
| Spectrum-2 6.4T (SN3700) | 1,370 | 1 | 0.0105 |
| Nvidia LinkX 1.6T DR8 (SiPho) | 54,187 | 30 | 0.4134 |
| Nvidia LinkX 800G DR4 | 53,904 | 30 | 0.4113 |
| Nvidia LinkX 200G SR4 | 23,920 | 13 | 0.1825 |
| Nvidia LinkX 800G Multimode | 74,159 | 41 | 0.5658 |
| Nvidia LinkX 400G Multimode | 380 | 0 | 0.0029 |
| Nvidia LinkX 200G Multimode | 10,655 | 6 | 0.0813 |
| RJ45 Cables | 65,763 | 36 | 0.5017 |
Compute Tray Networking Content
4 rows
Assigned blockDefault
Rubin Ultra - NVL72 - Generic
Compute TrayXPU: Rubin Ultra NVL724 linesshared by 11 SKUs
Compute Tray Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| NV Paladin Board to Board 32 Pin 4p8c (Male) | 131,072 | 72.00 | 1.00 |
| NV Paladin Board to Board 64 Pin 4p16c (Male) | 524,288 | 288.00 | 4.00 |
| NV Paladin Board to Board 32 Pin 4p8c (Female) | 131,072 | 72.00 | 1.00 |
| NV Paladin Board to Board 64 Pin 4p16c (Female) | 524,288 | 288.00 | 4.00 |
2026 share
Nvidia NVSwitch 7.0 (NVLink 7) - 28.8TΣ 100%
%
NV Sentry HD 448Gb/s 144DP (Male)Σ 100%
%
NV Sentry HD 448Gb/s 144DP (Female)Σ 100%
%
NV Sentry HD 448Gb/s 72DP (Male)Σ 100%
%
NV Sentry HD 448Gb/s 72DP (Female)Σ 100%
%
NVL Blade Column Spine Chassis (NvLink 7)Σ 100%
%
NV 224Gb/s SkewClear EXD Gen 2 Bidi CableΣ 100%
%
| Item | Unit Cost | Quantity | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Per-server cost: $258,723.00 | |||||||||||||||||||||
| $4,000.00 | 65,536 | 36.00 | 0.50 | $262,144,000.00 | $144,000.00 | 800 W | 52,428,800 W | 28,800 W | Scale-Up Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | NVLink | — | Rubin Ultra | Scale-Up | HS-RU NVL72-CX9-SN6800-CPO | |
| $864.00 | 65,536 | 36.00 | 0.50 | $56,623,104.00 | $31,104.00 | 0 W | 0 W | 0 W | Backplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 448G | NVLink | — | Rubin Ultra | Scale-Up | HS-RU NVL72-CX9-SN6800-CPO | |
| $432.00 | 65,536 | 36.00 | 0.50 | $28,311,552.00 | $15,552.00 | 0 W | 0 W | 0 W | Backplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 448G | NVLink | — | Rubin Ultra | Scale-Up | HS-RU NVL72-CX9-SN6800-CPO | |
| $432.00 | 131,072 | 72.00 | 1.00 | $56,623,104.00 | $31,104.00 | 0 W | 0 W | 0 W | Backplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 448G | NVLink | — | Rubin Ultra | Scale-Up | HS-RU NVL72-CX9-SN6800-CPO | |
| $216.00 | 131,072 | 72.00 | 1.00 | $28,311,552.00 | $15,552.00 | 0 W | 0 W | 0 W | Backplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 448G | NVLink | — | Rubin Ultra | Scale-Up | HS-RU NVL72-CX9-SN6800-CPO | |
| $337.50 | 3,641 | 2.00 | 0.03 | $1,228,800.00 | $675.00 | 0 W | 0 W | 0 W | Backplane | Default Hyperscaler | Others | Others | Device Level | — | — | NVLink | — | Rubin Ultra | Scale-Up | HS-RU NVL72-CX9-SN6800-CPO | |
| $4.00 | 9,437,184 | 5,184.00 | 72.00 | $37,748,736.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Rubin Ultra | Scale-Up | HS-RU NVL72-CX9-SN6800-CPO | |
Per-server cost: $1,156,138.26 | |||||||||||||||||||||
| $1,511.63 | 524,288 | 288.00 | 4.00 | $792,528,372.11 | $435,348.84 | 17 W | 8,912,896 W | 4,896 W | Transceiver | Default Hyperscaler | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | Rubin Ultra | Backend | HS-RU NVL72-CX9-SN6800-CPO | |
| $450.00 | 1,048,576 | 576.00 | 8.00 | $471,859,200.00 | $259,200.00 | 0 W | 0 W | 0 W | Fiber | Default Hyperscaler | Others | — | White Label | — | — | — | — | Rubin Ultra | Backend | HS-RU NVL72-CX9-SN6800-CPO | |
| $1,650.00 | 524,288 | 16.00 | 4.00 | $865,075,200.00 | $26,400.00 | 90 W | 47,185,920 W | 1,440 W | NIC | Default Hyperscaler | Nvidia | — | Device Level | — | — | — | — | Rubin Ultra | Backend | HS-RU NVL72-CX9-SN6800-CPO | |
| $257,890.03 | 3,072 | 1.69 | 0.02 | $792,238,161.92 | $435,189.42 | 12,615 W | 38,753,621 W | 21,288 W | Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | Ethernet | CPO | Rubin Ultra | Backend | HS-RU NVL72-CX9-SN6800-CPO | |
Per-server cost: $219,188.36 | |||||||||||||||||||||
| $32,526.91 | 1,573 | 0.86 | 0.01 | $51,177,326.94 | $28,112.55 | 1,344 W | 2,113,846 W | 1,161 W | Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | Ethernet | — | Rubin Ultra | Frontend | HS-RU NVL72-CX9-SN6800-CPO | |
| $15,000.00 | 7 | 0.00 | 0.00 | $97,523.81 | $53.57 | 670 W | 4,356 W | 2 W | Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | Ethernet | — | Rubin Ultra | Frontend | HS-RU NVL72-CX9-SN6800-CPO | |
| $21,600.00 | 234 | 0.13 | 0.00 | $5,055,634.29 | $2,777.14 | 630 W | 147,456 W | 81 W | Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | Ethernet | — | Rubin Ultra | Frontend | HS-RU NVL72-CX9-SN6800-CPO | |
| $13,273.51 | 1,924 | 1.06 | 0.01 | $25,544,462.89 | $14,031.99 | 250 W | 481,117 W | 264 W | Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | Ethernet | — | Rubin Ultra | Frontend | HS-RU NVL72-CX9-SN6800-CPO | |
| $1,723.40 | 76,114 | 41.81 | 0.58 | $131,175,333.71 | $72,056.76 | 22 W | 1,674,510 W | 920 W | Transceiver | Default Hyperscaler | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | Rubin Ultra | Frontend | HS-RU NVL72-CX9-SN6800-CPO | |
| $1,511.63 | 75,717 | 41.59 | 0.58 | $114,456,664.45 | $62,872.92 | 17 W | 1,287,197 W | 707 W | Transceiver | Default Hyperscaler | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | Rubin Ultra | Frontend | HS-RU NVL72-CX9-SN6800-CPO | |
| $325.00 | 33,600 | 18.46 | 0.26 | $10,920,066.03 | $5,998.57 | 5 W | 168,001 W | 92 W | Transceiver | Default Hyperscaler | Nvidia | Mellanox, Others | White Label | — | 56G | InfiniBand | Fully Retimed | Rubin Ultra | Frontend | HS-RU NVL72-CX9-SN6800-CPO | |
| $525.00 | 104,168 | 57.22 | 0.79 | $54,688,426.67 | $30,041.25 | 0 W | 0 W | 0 W | Fiber | Default Hyperscaler | Others | — | White Label | — | — | — | — | Rubin Ultra | Frontend | HS-RU NVL72-CX9-SN6800-CPO | |
| $375.00 | 533 | 0.29 | 0.00 | $199,923.81 | $109.82 | 0 W | 0 W | 0 W | Fiber | Default Hyperscaler | Others | — | White Label | — | — | — | — | Rubin Ultra | Frontend | HS-RU NVL72-CX9-SN6800-CPO | |
| $375.00 | 14,967 | 8.22 | 0.11 | $5,612,495.24 | $3,083.04 | 0 W | 0 W | 0 W | Fiber | Default Hyperscaler | Others | — | White Label | — | — | — | — | Rubin Ultra | Frontend | HS-RU NVL72-CX9-SN6800-CPO | |
| $1.00 | 92,375 | 50.74 | 0.70 | $92,374.55 | $50.74 | 0 W | 0 W | 0 W | Cable | Default Hyperscaler | Amphenol | — | Device Level | — | — | — | — | Rubin Ultra | Frontend | HS-RU NVL72-CX9-SN6800-CPO | |
Per-server cost: $62,208.00 | |||||||||||||||||||||
| $64.00 | 131,072 | 72.00 | 1.00 | $8,388,608.00 | $4,608.00 | 0 W | 0 W | 0 W | Midplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Rubin Ultra | Compute Tray | HS-RU NVL72-CX9-SN6800-CPO | |
| $128.00 | 524,288 | 288.00 | 4.00 | $67,108,864.00 | $36,864.00 | 0 W | 0 W | 0 W | Midplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Rubin Ultra | Compute Tray | HS-RU NVL72-CX9-SN6800-CPO | |
| $32.00 | 131,072 | 72.00 | 1.00 | $4,194,304.00 | $2,304.00 | 0 W | 0 W | 0 W | Midplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Rubin Ultra | Compute Tray | HS-RU NVL72-CX9-SN6800-CPO | |
| $64.00 | 524,288 | 288.00 | 4.00 | $33,554,432.00 | $18,432.00 | 0 W | 0 W | 0 W | Midplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Rubin Ultra | Compute Tray | HS-RU NVL72-CX9-SN6800-CPO | |
| By fabric | |||||||||||||||||||||
| Total Scale-Up | $470,990,848.00 | $258,723.00 | 52,428,800 W | 28,800 W | |||||||||||||||||
| Total Backend | $2,921,700,934.03 | $1,156,138.26 | 94,852,437 W | 27,624 W | |||||||||||||||||
| Total Frontend | $399,020,232.39 | $219,188.36 | 5,876,484 W | 3,228 W | |||||||||||||||||
| Total Compute Tray | $113,246,208.00 | $62,208.00 | 0 W | 0 W | |||||||||||||||||
| Grand Total Cluster Networking | $3,904,958,222.42 | $1,696,257.62 | 153,157,721 W | 59,652 W | |||||||||||||||||
| By component | |||||||||||||||||||||
| Total Transceivers | $1,049,080,436.31 | $576,277.10 | 12,042,604 W | 6,615 W | |||||||||||||||||
| Total Switches | $874,113,109.85 | $480,164.67 | 41,500,397 W | 22,797 W | |||||||||||||||||
| Total Fiber | $532,360,045.71 | $292,434.11 | 0 W | 0 W | |||||||||||||||||
| Total Cables | $92,374.55 | $50.74 | 0 W | 0 W | |||||||||||||||||
| Total Connectors | — | — | — | — | |||||||||||||||||
| Total NICs | $865,075,200.00 | $26,400.00 | 47,185,920 W | 1,440 W | |||||||||||||||||