Live DB — analyst tables
Test
Meta 122880 H100 CX-7 Hyperscaler Ethernet Cluster Configuration
META-H100-CX7-Eth-ARWB-129K
Meta · H100 · CX-7
Rack type
NVL8
Cluster / location
129k Ethernet Cluster
Buyer profile
Hyperscaler
Networking type
Ethernet
Number of XPUs
122,880
NIC used
CX-7
NICs / XPU
1
Scale-out BW / XPU
400G
XPU / server
8
Scale-up network
1 rows
Assigned blockDefault
H100 - NVL8
Scale-UpXPU: H100 NVL81 lineshared by 17 SKUs
Scale-Up Parts Summary
1
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia NVSwitch 3.0 (NVLink 4) | 61,440 | 4.00 | 0.50 |
Backend network
9 rows
Assigned blockDefault
H100 - NVL8 - CX7 - 3L - ETH - Minipack-2 OCP Rack - META
BackendXPU: H100 NVL89 linesshared by 1 SKU
Backend Parts Summary
9
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Generic 400G DAC | 122,880 | 8.00 | 1.00 |
| Generic 400G DR4 | 261,120 | 17.00 | 2.13 |
| Generic 400G Single Mode | 138,240 | 9.00 | 1.13 |
| ConnectX-7 NIC - 400G | 122,880 | 8.00 | 1.00 |
| Generic 800G DR8 | 123,840 | 8.06 | 1.01 |
| Minipack-2 OCP Rack 25.6T | 7,680 | 0.50 | 0.06 |
| Generic 800G Single Mode | 27,360 | 1.78 | 0.22 |
| Arista 115.2T Modular Chassis (7804R4) | 1,100 | 0.07 | 0.01 |
| Generic 800G 2xFR4 | 27,360 | 1.78 | 0.22 |
Frontend network
11 rows
Assigned blockDefault
H100 - NVL8 - Minipack-3 - META
FrontendXPU: H100 NVL811 linesshared by 4 SKUs
Frontend Parts Summary
11
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Minipack-3 OCP Rack 51.2T | 197 | 0 | 0.0016 |
| Minipack-1 OCP Rack 12.8T | 1 | 0 | 0.0000 |
| WhiteBox Tomahawk 2 6.4T | 29 | 0 | 0.0002 |
| Generic 1GbE Ethernet | 241 | 0 | 0.0020 |
| Generic 800G DR8 | 9,514 | 1 | 0.0774 |
| Generic 400G DR4 | 9,465 | 1 | 0.0770 |
| Generic 100G DR4 QSFP28 | 4,200 | 0 | 0.0342 |
| Generic 800G Single Mode | 13,021 | 1 | 0.1060 |
| Generic 400G Single Mode | 67 | 0 | 0.0005 |
| Generic 100G Single Mode | 1,871 | 0 | 0.0152 |
| RJ45 Cables | 11,547 | 1 | 0.0940 |
Compute Tray Networking Content
1 rows
Assigned blockDefault
H100 - NVL8 - Generic
Compute TrayXPU: H100 NVL81 lineshared by 16 SKUs
Compute Tray Parts Summary
1
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| NVLink PCIe 5.0 x16 Retimer | 122,880 | 8.00 | 1.00 |
2026 share
Nvidia NVSwitch 3.0 (NVLink 4)Σ 100%
%
| Item | Unit Cost | Quantity | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Per-server cost: $4,800.00 | |||||||||||||||||||||
| $1,200.00 | 61,440 | 4.00 | 0.50 | $73,728,000.00 | $4,800.00 | 407 W | 25,030,656 W | 1,630 W | Scale-Up Switch | Meta | Nvidia | — | Device Level | — | — | NVLink | — | H100 | Scale-Up | META-H100-CX7-Eth-ARWB-129K | |
Per-server cost: $31,884.06 | |||||||||||||||||||||
| $40.00 | 122,880 | 8.00 | 1.00 | $4,915,200.00 | $320.00 | 0 W | 0 W | 0 W | DAC | Meta | Amphenol | — | Device Level | — | — | — | — | H100 | Backend | META-H100-CX7-Eth-ARWB-129K | |
| $260.00 | 261,120 | 17.00 | 2.13 | $67,891,200.00 | $4,420.00 | 10 W | 2,611,200 W | 170 W | Transceiver | Meta | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | H100 | Backend | META-H100-CX7-Eth-ARWB-129K | |
| $130.00 | 138,240 | 9.00 | 1.13 | $17,971,200.00 | $1,170.00 | 0 W | 0 W | 0 W | Fiber | Meta | Amphenol | — | Device Level | — | — | — | — | H100 | Backend | META-H100-CX7-Eth-ARWB-129K | |
| $800.00 | 122,880 | 8.00 | 1.00 | $98,304,000.00 | $6,400.00 | 50 W | 6,144,000 W | 400 W | NIC | Meta | Nvidia | — | Device Level | — | — | — | — | H100 | Backend | META-H100-CX7-Eth-ARWB-129K | |
| $500.00 | 123,840 | 8.06 | 1.01 | $61,920,000.00 | $4,031.25 | 16 W | 1,981,440 W | 129 W | Transceiver | Meta | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | H100 | Backend | META-H100-CX7-Eth-ARWB-129K | |
| $13,500.00 | 7,680 | 0.50 | 0.06 | $103,680,000.00 | $6,750.00 | 850 W | 6,528,000 W | 425 W | Switch | Meta | Celestica | — | Device Level | — | — | — | — | H100 | Backend | META-H100-CX7-Eth-ARWB-129K | |
| $180.00 | 27,360 | 1.78 | 0.22 | $4,924,800.00 | $320.63 | 0 W | 0 W | 0 W | Fiber | Meta | Corning | — | Device Level | — | — | — | — | H100 | Backend | META-H100-CX7-Eth-ARWB-129K | |
| $106,363.64 | 1,100 | 0.07 | 0.01 | $117,000,000.00 | $7,617.19 | 9,000 W | 9,900,000 W | 645 W | Switch | Meta | Arista | — | Device Level | — | — | — | — | H100 | Backend | META-H100-CX7-Eth-ARWB-129K | |
| $480.00 | 27,360 | 1.78 | 0.22 | $13,132,800.00 | $855.00 | 15 W | 410,400 W | 27 W | Transceiver | Meta | Coherent | — | Device Level | — | 112G | Ethernet | Fully Retimed | H100 | Backend | META-H100-CX7-Eth-ARWB-129K | |
Per-server cost: $7,415.17 | |||||||||||||||||||||
| $25,200.00 | 1,475 | 0.10 | 0.01 | $37,171,200.00 | $2,420.00 | 1,200 W | 1,770,057 W | 115 W | Switch | Meta | Accton | — | Device Level | — | — | — | — | H100 | Frontend | META-H100-CX7-Eth-ARWB-129K | |
| $5,000.00 | 6 | 0.00 | 0.00 | $30,476.19 | $1.98 | 450 W | 2,743 W | 0 W | Switch | Meta | Celestica | — | Device Level | — | — | — | — | H100 | Frontend | META-H100-CX7-Eth-ARWB-129K | |
| $3,072.57 | 219 | 0.01 | 0.00 | $674,209.85 | $43.89 | 250 W | 54,857 W | 4 W | Switch | Meta | Accton | — | Device Level | — | — | — | — | H100 | Frontend | META-H100-CX7-Eth-ARWB-129K | |
| $350.00 | 1,804 | 0.12 | 0.01 | $631,466.67 | $41.11 | 100 W | 180,419 W | 12 W | Switch | Meta | Accton | — | Device Level | — | — | — | — | H100 | Frontend | META-H100-CX7-Eth-ARWB-129K | |
| $500.00 | 71,357 | 4.65 | 0.58 | $35,678,476.19 | $2,322.82 | 16 W | 1,141,711 W | 74 W | Transceiver | Meta | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | H100 | Frontend | META-H100-CX7-Eth-ARWB-129K | |
| $260.00 | 70,985 | 4.62 | 0.58 | $18,456,137.14 | $1,201.57 | 10 W | 709,851 W | 46 W | Transceiver | Meta | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | H100 | Frontend | META-H100-CX7-Eth-ARWB-129K | |
| $54.00 | 31,500 | 2.05 | 0.26 | $1,701,010.29 | $110.74 | 3 W | 94,501 W | 6 W | Transceiver | Meta | AAOI | — | Device Level | — | 28G | Ethernet | Fully Retimed | H100 | Frontend | META-H100-CX7-Eth-ARWB-129K | |
| $180.00 | 97,658 | 6.36 | 0.79 | $17,578,422.86 | $1,144.43 | 0 W | 0 W | 0 W | Fiber | Meta | Corning | — | Device Level | — | — | — | — | H100 | Frontend | META-H100-CX7-Eth-ARWB-129K | |
| $130.00 | 500 | 0.03 | 0.00 | $64,975.24 | $4.23 | 0 W | 0 W | 0 W | Fiber | Meta | Amphenol | — | Device Level | — | — | — | — | H100 | Frontend | META-H100-CX7-Eth-ARWB-129K | |
| $130.00 | 14,031 | 0.91 | 0.11 | $1,824,060.95 | $118.75 | 0 W | 0 W | 0 W | Fiber | Meta | Corning | — | Device Level | — | — | — | — | H100 | Frontend | META-H100-CX7-Eth-ARWB-129K | |
| $1.00 | 86,601 | 5.64 | 0.70 | $86,601.14 | $5.64 | 0 W | 0 W | 0 W | Cable | Meta | Amphenol | — | Device Level | — | — | — | — | H100 | Frontend | META-H100-CX7-Eth-ARWB-129K | |
Per-server cost: $466.67 | |||||||||||||||||||||
| $58.33 | 122,880 | 8.00 | 1.00 | $7,167,999.96 | $466.67 | 9 W | 1,105,920 W | 72 W | Retimer | Meta | Astera | Astera | L1 Abstraction | — | — | — | — | H100 | Compute Tray | META-H100-CX7-Eth-ARWB-129K | |
| By fabric | |||||||||||||||||||||
| Total Scale-Up | $73,728,000.00 | $4,800.00 | 25,030,656 W | 1,630 W | |||||||||||||||||
| Total Backend | $489,739,200.00 | $31,884.06 | 27,575,040 W | 1,795 W | |||||||||||||||||
| Total Frontend | $113,897,036.52 | $7,415.17 | 3,954,139 W | 257 W | |||||||||||||||||
| Total Compute Tray | $7,167,999.96 | $466.67 | 1,105,920 W | 72 W | |||||||||||||||||
| Grand Total Cluster Networking | $684,532,236.48 | $44,565.90 | 57,665,755 W | 3,754 W | |||||||||||||||||
| By component | |||||||||||||||||||||
| Total Transceivers | $198,779,623.62 | $12,941.38 | 6,949,103 W | 452 W | |||||||||||||||||
| Total Switches | $259,187,352.71 | $16,874.18 | 18,436,076 W | 1,200 W | |||||||||||||||||
| Total Fiber | $42,363,459.05 | $2,758.04 | 0 W | 0 W | |||||||||||||||||
| Total Cables | $86,601.14 | $5.64 | 0 W | 0 W | |||||||||||||||||
| Total Connectors | — | — | — | — | |||||||||||||||||
| Total NICs | $98,304,000.00 | $6,400.00 | 6,144,000 W | 400 W | |||||||||||||||||