Live DB — analyst tables
Test
HS-Feynman NVL144-CX10-TH7-NPO
HS-Feynman NVL144-CX10-TH7-NPO
Default Hyperscaler · Feynman · CX10
Rack type
Kyber NVL144
Cluster / location
Default Hyperscaler Kyber NVL144 TH6 NPO (NPO)
Buyer profile
Hyperscaler
Networking type
Ethernet
Number of XPUs
131,072
NIC used
CX10
NICs / XPU
3
Scale-out BW / XPU
4.8T
XPU / server
144
Scale-up network
5 rows
Assigned blockDefault
Feynman - Kyber NVL144
Scale-UpXPU: Feynman Kyber NVL1445 linesshared by 11 SKUs
Scale-Up Parts Summary
5
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia NVSwitch 8.0 (NVLink 8) | 32,768 | 36.00 | 0.25 |
| NV Sentry HD 448Gb/s 144DP (Male) | 262,144 | 288.00 | 2.00 |
| NV Sentry HD 448Gb/s 144DP (Female) | 262,144 | 288.00 | 2.00 |
| NVL Blade Column Spine Chassis (NvLink 7) | 1,820 | 2.00 | 0.01 |
| NVL Kyber Canister Midplane PCB (NvLink 7) | 910 | 1.00 | 0.01 |
Backend network
4 rows
Assigned blockDefault
Feynman - Kyber NVL144 - CX10 - 2L - ETH - TH7 - Generic
BackendXPU: Feynman Kyber NVL1444 linesshared by 1 SKU
Backend Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia LinkX 800G DR4 | 786,432 | 864.00 | 6.00 |
| Nvidia LinkX 800G Single Mode | 1,572,864 | 1,728.00 | 12.00 |
| ConnectX-10 NIC - 1.6T | 393,216 | 432.00 | 3.00 |
| Generic Tomahawk 7 204.8T NPO | 9,216 | 10.13 | 0.07 |
Frontend network
11 rows
Assigned blockDefault
Feynman - Kyber NVL144 - SN6600 - Generic
FrontendXPU: Feynman Kyber NVL14411 linesshared by 11 SKUs
Frontend Parts Summary
11
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Spectrum-6 102.4T x1600 (SN6600) | 1,120 | 1 | 0.0085 |
| Spectrum-4 25.6T (SN5400) | 5 | 0 | 0.0000 |
| Spectrum-3 12.8T (SN4700) | 167 | 0 | 0.0013 |
| Spectrum-2 6.4T (SN3700) | 1,370 | 2 | 0.0105 |
| Nvidia LinkX 1.6T DR8 (SiPho) | 54,187 | 60 | 0.4134 |
| Nvidia LinkX 800G DR4 | 53,904 | 59 | 0.4113 |
| Nvidia LinkX 200G SR4 | 23,920 | 26 | 0.1825 |
| Nvidia LinkX 800G Multimode | 74,159 | 81 | 0.5658 |
| Nvidia LinkX 400G Multimode | 380 | 0 | 0.0029 |
| Nvidia LinkX 200G Multimode | 10,655 | 12 | 0.0813 |
| RJ45 Cables | 65,763 | 72 | 0.5017 |
Compute Tray Networking Content
4 rows
Assigned blockDefault
Feynman - Kyber NVL144 - Generic
Compute TrayXPU: Feynman Kyber NVL1444 linesshared by 11 SKUs
Compute Tray Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| NV Paladin Board to Board 32 Pin 4p8c (Male) | 131,072 | 144.00 | 1.00 |
| NV Paladin Board to Board 64 Pin 4p16c (Male) | 524,288 | 576.00 | 4.00 |
| NV Paladin Board to Board 32 Pin 4p8c (Female) | 131,072 | 144.00 | 1.00 |
| NV Paladin Board to Board 64 Pin 4p16c (Female) | 524,288 | 576.00 | 4.00 |
2026 share
Generic Tomahawk 7 204.8T NPOΣ 100%
%
| Item | Unit Cost | Quantity | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Per-server cost: $1,065,351.57 | |||||||||||||||||||||
| $16,428.57 | 32,768 | 36.00 | 0.25 | $538,331,428.59 | $591,428.57 | 800 W | 26,214,400 W | 28,800 W | Scale-Up Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | NVLink | — | Feynman | Scale-Up | HS-Feynman NVL144-CX10-TH7-NPO | |
| $864.00 | 262,144 | 288.00 | 2.00 | $226,492,416.00 | $248,832.00 | 0 W | 0 W | 0 W | Backplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 448G | NVLink | — | Feynman | Scale-Up | HS-Feynman NVL144-CX10-TH7-NPO | |
| $432.00 | 262,144 | 288.00 | 2.00 | $113,246,208.00 | $124,416.00 | 0 W | 0 W | 0 W | Backplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 448G | NVLink | — | Feynman | Scale-Up | HS-Feynman NVL144-CX10-TH7-NPO | |
| $337.50 | 1,820 | 2.00 | 0.01 | $614,400.00 | $675.00 | 0 W | 0 W | 0 W | Backplane | Default Hyperscaler | Others | Others | Device Level | — | — | NVLink | — | Feynman | Scale-Up | HS-Feynman NVL144-CX10-TH7-NPO | |
| $100,000.00 | 910 | 1.00 | 0.01 | $91,022,222.22 | $100,000.00 | 0 W | 0 W | 0 W | Backplane | Default Hyperscaler | Others | Others | Device Level | — | — | NVLink | — | Feynman | Scale-Up | HS-Feynman NVL144-CX10-TH7-NPO | |
Per-server cost: $3,046,109.15 | |||||||||||||||||||||
| $1,511.63 | 786,432 | 864.00 | 6.00 | $1,188,792,558.16 | $1,306,046.51 | 17 W | 13,369,344 W | 14,688 W | Transceiver | Default Hyperscaler | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | Feynman | Backend | HS-Feynman NVL144-CX10-TH7-NPO | |
| $450.00 | 1,572,864 | 1,728.00 | 12.00 | $707,788,800.00 | $777,600.00 | 0 W | 0 W | 0 W | Fiber | Default Hyperscaler | Others | — | White Label | — | — | — | — | Feynman | Backend | HS-Feynman NVL144-CX10-TH7-NPO | |
| $3,500.00 | 393,216 | 12.00 | 3.00 | $1,376,256,000.00 | $42,000.00 | 100 W | 39,321,600 W | 1,200 W | NIC | Default Hyperscaler | Nvidia | — | Device Level | — | — | — | — | Feynman | Backend | HS-Feynman NVL144-CX10-TH7-NPO | |
| $90,909.89 | 9,216 | 10.13 | 0.07 | $837,825,550.20 | $920,462.64 | 1,500 W | 13,824,000 W | 15,188 W | Switch | Default Hyperscaler | Broadcom | — | Device Level | — | 224G | Ethernet | NPO | Feynman | Backend | HS-Feynman NVL144-CX10-TH7-NPO | |
Per-server cost: $438,376.72 | |||||||||||||||||||||
| $32,526.91 | 1,573 | 1.73 | 0.01 | $51,177,326.94 | $56,225.09 | 1,344 W | 2,113,846 W | 2,322 W | Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | Ethernet | — | Feynman | Frontend | HS-Feynman NVL144-CX10-TH7-NPO | |
| $15,000.00 | 7 | 0.01 | 0.00 | $97,523.81 | $107.14 | 670 W | 4,356 W | 5 W | Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | Ethernet | — | Feynman | Frontend | HS-Feynman NVL144-CX10-TH7-NPO | |
| $21,600.00 | 234 | 0.26 | 0.00 | $5,055,634.29 | $5,554.29 | 630 W | 147,456 W | 162 W | Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | Ethernet | — | Feynman | Frontend | HS-Feynman NVL144-CX10-TH7-NPO | |
| $13,273.51 | 1,924 | 2.11 | 0.01 | $25,544,462.89 | $28,063.99 | 250 W | 481,117 W | 529 W | Switch | Default Hyperscaler | Nvidia | — | Device Level | — | — | Ethernet | — | Feynman | Frontend | HS-Feynman NVL144-CX10-TH7-NPO | |
| $1,723.40 | 76,114 | 83.62 | 0.58 | $131,175,333.71 | $144,113.53 | 22 W | 1,674,510 W | 1,840 W | Transceiver | Default Hyperscaler | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | Feynman | Frontend | HS-Feynman NVL144-CX10-TH7-NPO | |
| $1,511.63 | 75,717 | 83.19 | 0.58 | $114,456,664.45 | $125,745.85 | 17 W | 1,287,197 W | 1,414 W | Transceiver | Default Hyperscaler | Nvidia | Coherent, Eoptolink, Innolight, Mellanox | White Label | — | 224G | InfiniBand | Fully Retimed | Feynman | Frontend | HS-Feynman NVL144-CX10-TH7-NPO | |
| $325.00 | 33,600 | 36.91 | 0.26 | $10,920,066.03 | $11,997.14 | 5 W | 168,001 W | 185 W | Transceiver | Default Hyperscaler | Nvidia | Mellanox, Others | White Label | — | 56G | InfiniBand | Fully Retimed | Feynman | Frontend | HS-Feynman NVL144-CX10-TH7-NPO | |
| $525.00 | 104,168 | 114.44 | 0.79 | $54,688,426.67 | $60,082.50 | 0 W | 0 W | 0 W | Fiber | Default Hyperscaler | Others | — | White Label | — | — | — | — | Feynman | Frontend | HS-Feynman NVL144-CX10-TH7-NPO | |
| $375.00 | 533 | 0.59 | 0.00 | $199,923.81 | $219.64 | 0 W | 0 W | 0 W | Fiber | Default Hyperscaler | Others | — | White Label | — | — | — | — | Feynman | Frontend | HS-Feynman NVL144-CX10-TH7-NPO | |
| $375.00 | 14,967 | 16.44 | 0.11 | $5,612,495.24 | $6,166.07 | 0 W | 0 W | 0 W | Fiber | Default Hyperscaler | Others | — | White Label | — | — | — | — | Feynman | Frontend | HS-Feynman NVL144-CX10-TH7-NPO | |
| $1.00 | 92,375 | 101.49 | 0.70 | $92,374.55 | $101.49 | 0 W | 0 W | 0 W | Cable | Default Hyperscaler | Amphenol | — | Device Level | — | — | — | — | Feynman | Frontend | HS-Feynman NVL144-CX10-TH7-NPO | |
Per-server cost: $124,416.00 | |||||||||||||||||||||
| $64.00 | 131,072 | 144.00 | 1.00 | $8,388,608.00 | $9,216.00 | 0 W | 0 W | 0 W | Midplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Feynman | Compute Tray | HS-Feynman NVL144-CX10-TH7-NPO | |
| $128.00 | 524,288 | 576.00 | 4.00 | $67,108,864.00 | $73,728.00 | 0 W | 0 W | 0 W | Midplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Feynman | Compute Tray | HS-Feynman NVL144-CX10-TH7-NPO | |
| $32.00 | 131,072 | 144.00 | 1.00 | $4,194,304.00 | $4,608.00 | 0 W | 0 W | 0 W | Midplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Feynman | Compute Tray | HS-Feynman NVL144-CX10-TH7-NPO | |
| $64.00 | 524,288 | 576.00 | 4.00 | $33,554,432.00 | $36,864.00 | 0 W | 0 W | 0 W | Midplane | Default Hyperscaler | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | Feynman | Compute Tray | HS-Feynman NVL144-CX10-TH7-NPO | |
| By fabric | |||||||||||||||||||||
| Total Scale-Up | $969,706,674.81 | $1,065,351.57 | 26,214,400 W | 28,800 W | |||||||||||||||||
| Total Backend | $4,110,662,908.36 | $3,046,109.15 | 66,514,944 W | 31,076 W | |||||||||||||||||
| Total Frontend | $399,020,232.39 | $438,376.72 | 5,876,484 W | 6,456 W | |||||||||||||||||
| Total Compute Tray | $113,246,208.00 | $124,416.00 | 0 W | 0 W | |||||||||||||||||
| Grand Total Cluster Networking | $5,592,636,023.56 | $4,674,253.44 | 98,605,828 W | 66,332 W | |||||||||||||||||
| By component | |||||||||||||||||||||
| Total Transceivers | $1,445,344,622.36 | $1,587,903.03 | 16,499,052 W | 18,126 W | |||||||||||||||||
| Total Switches | $919,700,498.13 | $1,010,413.14 | 16,570,776 W | 18,205 W | |||||||||||||||||
| Total Fiber | $768,289,645.71 | $844,068.21 | 0 W | 0 W | |||||||||||||||||
| Total Cables | $92,374.55 | $101.49 | 0 W | 0 W | |||||||||||||||||
| Total Connectors | — | — | — | — | |||||||||||||||||
| Total NICs | $1,376,256,000.00 | $42,000.00 | 39,321,600 W | 1,200 W | |||||||||||||||||