Live DB — analyst tables
Test
Neoclouds/AI Lab/SovAI 18432 VR300 CPX CX-10 Neocloud Giant Infiniband Cluster Configuration
OTHER-RubinUltra CPX-IB-4R
Neoclouds/AI Lab/SovAI · VR300 CPX · CX-10
Rack type
—
Cluster / location
Default VR300 CPX
Buyer profile
Emerging Neocloud
Networking type
Infiniband
Number of XPUs
18,432
NIC used
CX-10
NICs / XPU
1
Scale-out BW / XPU
1.6T
XPU / server
144
Scale-up network
Assigned blockDefault
VR300 CPX
Scale-UpXPU: VR300 CPX0 linesshared by 2 SKUs
Scale-up Units are based on the scale-up world size (144 XPUs).
XPU World Size
2
WS| Scale-Up Network Layer | Part / Model | Units# | Unit BWGbit/s uni-d | Lane Count# | Lane BWGbit/s uni-d |
|---|---|---|---|---|---|
| XPUs per Node | · | 8 | · | · | · |
| Scale-Up World Size | · | 144 | 0 | · | · |
Switches
1
SW| Scale-Up Network Layer | Part / Model | Units# | Unit BWGbit/s uni-d | Lane Count# | Lane BWGbit/s uni-d |
|---|---|---|---|---|---|
| Scale-Up Switch Total | · | · | 0 | · | · |
Connections & cabling
3
CN| Scale-Up Network Layer | Part / Model | Units# | BW / PortGbit/s uni-d | Unit DP# | DP / Port# | Total DPs# | BW / Connector | Cable / Model | Cable Units# |
|---|---|---|---|---|---|---|---|---|---|
| Male Connectors | · | · | · | · | · | · | · | Already Counted Below | · |
| Female Connectors | · | · | · | · | · | · | · | Already Counted Below | · |
| Switch Total | |||||||||
| Male Connectors | · | · | · | · | · | · | · | Already Counted Below | · |
Notes
- Scale-Up World Size — >>18 trays of 8 CPX per rack
Scale-Up Parts Summary
0
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|
Backend network
4 rows
Assigned blockDefault
VR300 CPX - CX10 - 3L - IB - X800-Q3400-RA - Generic
BackendXPU: VR300 CPX4 linesshared by 1 SKU
Backend Units are based on the cluster size (18,432 XPUs).
Switches
5
SW Network Layer | Switch and Server Spec | Aggregate Port Utilization | Network Bandwidth Aggregate | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SwitchPart Name / Model | Units# | Unit BWGbit/s | Port BWGbit/s | Downlink Ports / SW# | Uplink Ports / SW# | Max Ports# | Downlink Ports# | Uplink Ports# | Total Ports# | Downlink BWTbit/s | Uplink BWTbit/s | OversubRatio | |
| XPUs | · | 18,432 | 1,600 | 1,600 | 0 | 18,432 | 18,432 | 0 | 18,432 | 18,432 | 0 | 29,491.2 | · |
| NICs per Node | ConnectX-10 NIC - 1.6T | 8 | 1,600 | · | · | · | 8 | · | · | · | · | · | · |
| Leaf | Quantum-X800-Q3400-RA (Air Cooled) | 512 | 115,200 | 1,600 | 36 | 36 | 72 | 18,432 | 18,432 | 36,864 | 29,491.2 | 29,491.2 | 1 |
| Spine | Quantum-X800-Q3400-RA (Air Cooled) | 512 | 115,200 | 1,600 | 36 | 36 | 72 | 18,432 | 18,432 | 36,864 | 29,491.2 | 29,491.2 | 1 |
| Core | Quantum-X800-Q3400-RA (Air Cooled) | 256 | 115,200 | 1,600 | 72 | · | 72 | 18,432 | 0 | 18,432 | 29,491.2 | 0 | · |
Transceivers
6
CN Network Layer | Transceiver / CablePart Name / Model | Total Units# | Units per SW/GPU# | Unit BWGbit/s | Lanes# | BW per LaneGbit/s | Agg. BWTbit/s |
|---|---|---|---|---|---|---|---|
| XPU Nodes | Nvidia LinkX 1.6T DR8 (SiPho) | 36,864 | 36,864 | 1,600 | 8 | 200 | 58,982.4 |
| Leaf | |||||||
| Downlink | Nvidia LinkX 1.6T DR8 (SiPho) | 18,432 | 36 | 1,600 | 8 | 200 | 29,491.2 |
| Uplink | Nvidia LinkX 1.6T DR8 (SiPho) | 18,432 | 36 | 1,600 | 8 | 200 | 29,491.2 |
| Spine | |||||||
| Downlink | Nvidia LinkX 1.6T DR8 (SiPho) | 18,432 | 36 | 1,600 | 8 | 200 | 29,491.2 |
| Uplink | Nvidia LinkX 1.6T DR8 (SiPho) | 18,432 | 36 | 1,600 | 8 | 200 | 29,491.2 |
| Core | |||||||
| Downlink | Nvidia LinkX 1.6T DR8 (SiPho) | 18,432 | 72 | 1,600 | 8 | 200 | 29,491.2 |
| Uplink | · | · | · | · | · | · | · |
| Super-Core | |||||||
Cables
6
CB Network Layer | Cable/ FiberType | Total Units# | Units per Transceiver# | Unit BWGbit/s | Lane Count# | SerDes BWGbit/s |
|---|---|---|---|---|---|---|
| XPU Nodes | Nvidia LinkX 800G DR4 Single Mode | 73,728 | 2 | 800 | 4 | 200 |
| Leaf | ||||||
| Downlink | Already counted above | · | · | · | · | · |
| Uplink | Nvidia LinkX 800G DR4 Single Mode | 36,864 | 2 | 800 | 4 | 200 |
| Spine | ||||||
| Downlink | Already counted above | · | · | · | · | · |
| Uplink | Nvidia LinkX 800G DR4 Single Mode | 36,864 | 2 | 800 | 4 | 200 |
| Core | ||||||
| Downlink | Already counted above | · | · | · | · | · |
| Uplink | · | · | · | · | · | · |
| Super-Core | ||||||
Backend Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia LinkX 1.6T DR8 (SiPho) | 129,024 | 1,008.00 | 7.00 |
| Nvidia LinkX 800G DR4 Single Mode | 147,456 | 1,152.00 | 8.00 |
| ConnectX-10 NIC - 1.6T | 36,864 | 288.00 | 2.00 |
| Quantum-X800-Q3400-RA (Air Cooled) | 1,280 | 10.00 | 0.07 |
Frontend network
No converged frontend + storage fabric data for this cluster.
Frontend Parts Summary
0
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|
Compute Tray Networking Content
Networking components inside the compute tray — accelerators, board-to-board connectors, retimers, and their per-tray bandwidth.
Assigned blockDefault
VR300 CPX - Generic
Compute TrayXPU: VR300 CPX0 linesshared by 2 SKUs
| Tray layer | Part / Model | Units per Tray | Unit BWGb/s | Lanes | Lane BWGb/s | Per switch |
|---|
Compute Tray Parts Summary
0
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|