Live DB — analyst tables
Test
Amazon 131072 GB200 NVL72 Nitro-v6 Hyperscaler EFA Cluster Configuration

AWS-GB300 NVL72 JBOK-EFA-WB

Amazon · GB300 · Nitro-v6

Rack type
NVL72
Cluster / location
GB300 NVL72 Clusters
Buyer profile
Hyperscaler
Networking type
EFA
Number of XPUs
131,072
NIC used
Nitro-v6
NICs / XPU
2
Scale-out BW / XPU
800G
XPU / server
72

Scale-up network

8 rows
Assigned blockDefault
GB300 - NVL72
Scale-UpXPU: GB300 NVL728 linesshared by 22 SKUs

Scale-up Units are based on the scale-up world size (72 XPUs).

XPU World Size

2
WS
Scale-Up Network LayerPart / Model
Units#
Unit BWGbit/s uni-d
Port Count#
Port BWGbit/s uni-d
XPUs per Node·47,20018400
Scale-Up World Size·72518,400··

Switches

2
SW
Scale-Up Network LayerPart / Model
Units#
Unit BWGbit/s uni-d
Port Count#
Port BWGbit/s uni-d
per SwitchNvidia NVSwitch 5.0 (NVLink 5)128,80072400
Scale-Up Switch Total·18518,400··

Connections & cabling

8
CN
Scale-Up Network LayerPart / Model
Units#
BW / PortGbit/s uni-d
Unit DP#
DP / Port#
Total DPs#
BW / ConnectorCable / Model
Cable Units#
Ultrapass to SwitchNV 2 UltraPass OverPass 144 DP 224Gb/s3640014445,18414,400··
Male ConnectorsNV Paladin HD2 224Gb/s 144 DP (Male)3640014445,18414,400Already Counted Below·
Female ConnectorsNV Paladin HD2 224Gb/s 144 DP (Female)3640014445,18414,400Already Counted Below·
Switch Total** Two connectors per switch·····28,800··
Male ConnectorsNV Paladin HD2 224Gb/s 72 DP (Male)724007245,1847,200Already Counted Below·
Female ConnectorsNV Paladin HD2 224Gb/s 72 DP (Female)724007245,1847,200NV 224Gb/s SkewClear EXD Gen 2 Cable5,184
XPU Total** One connector per GPU·····7,200··
·NVL Spine Chassis (NvLink 5)2·······

Scale-Up Parts Summary

8
ItemQty/ClusterQty/ServerAttach/XPU
Nvidia NVSwitch 5.0 (NVLink 5)32,76818.000.25
NV 2 UltraPass OverPass 144 DP 224Gb/s65,53636.000.50
NV Paladin HD2 224Gb/s 144 DP (Male)65,53636.000.50
NV Paladin HD2 224Gb/s 144 DP (Female)65,53636.000.50
NV Paladin HD2 224Gb/s 72 DP (Male)131,07272.001.00
NV Paladin HD2 224Gb/s 72 DP (Female)131,07272.001.00
NV 224Gb/s SkewClear EXD Gen 2 Cable9,437,1845,184.0072.00
NVL Spine Chassis (NvLink 5)3,6412.000.03

Backend network

5 rows
Assigned blockDefault
GB300 - NVL72 - EFAv4 - 3L - ETH - TH5 - AWS
BackendXPU: GB300 NVL725 linesshared by 1 SKU

Backend Units are based on the cluster size (131,072 XPUs).

Switches

5
SW
 Network Layer
Switch and Server SpecAggregate Port UtilizationNetwork Bandwidth Aggregate
SwitchPart Name / Model
Units#
Unit BWGbit/s
Port BWGbit/s
Downlink Ports / SW#
Uplink Ports / SW#
Max Ports#
Downlink Ports#
Uplink Ports#
Total Ports#
Downlink BWTbit/s
Uplink BWTbit/s
OversubRatio
XPUs·131,0728008000131,072131,0720131,072131,0720104,857.6·
NICs per NodeEFAv4 Nitro-v6 400G NIC8400800··8······
ToRWhiteBox Tomahawk 5 51.2T4,09651,200400161612865,53665,536524,28826,214.426,214.41
LeafWhiteBox Tomahawk 5 51.2T4,09651,2004006464128262,144262,144524,288104,857.6104,857.61
SpineWhiteBox Tomahawk 5 51.2T2,04851,2004001280128262,1440262,144104,857.60·

Transceivers

7
CN
 Network Layer
Transceiver / CablePart Name / Model
Total Units#
Units per SW/GPU#
Unit BWGbit/s
Lanes#
BW per LaneGbit/s
Agg. BWTbit/s
GPU NodesGeneric 400G DR4262,144262,1444004100104,857.6
Leaf
DownlinkGeneric 800G DR8131,072328008100104,857.6
UplinkGeneric 800G DR8131,07232800#ERR1000
Spine
DownlinkGeneric 800G DR8131,07264800#ERR1000
Uplink·······
Core
Downlink·······
Uplink·······
Super-CoreNote - GPU Nodes here means the JBOK. It is PCIe AEC from Compute tray to JBOK, then optical from there······
ToR
DownlinkGeneric 400G DR465,536164008100104,857.6
UplinkGeneric 400G DR465,536164008100104,857.6

Cables

7
CB
 Network Layer
Cable/ FiberType
Total Units#
Units per Transceiver#
Unit BWGbit/s
Lane Count#
SerDes BWGbit/s
GPU NodesGeneric 400G Single Mode262,14414004100
Leaf
DownlinkAlready counted above·····
UplinkGeneric 400G Single Mode262,14424004100
Spine
Downlink······
Uplink······
Core
Downlink······
Uplink······
Super-CoreNote - GPU Nodes here means the JBOK. It is PCIe AEC from Compute tray to JBOK, then optical from there·····
ToR
DownlinkAlready counted above·····
UplinkGeneric 400G Single Mode65,53614004100

Backend Parts Summary

5
ItemQty/ClusterQty/ServerAttach/XPU
Generic 400G DR4393,216216.003.00
Generic 400G Single Mode589,824324.004.50
EFAv4 Nitro-v6 400G NIC262,144144.002.00
Generic 800G DR8393,216216.003.00
WhiteBox Tomahawk 5 51.2T10,2405.630.08

Frontend network

No converged frontend + storage fabric data for this cluster.

Frontend Parts Summary

0
ItemQty/ClusterQty/ServerAttach/XPU

Compute Tray Networking Content

5 rows

Networking components inside the compute tray — accelerators, board-to-board connectors, retimers, and their per-tray bandwidth.

Assigned blockDefault
GB300 - NVL72 - AWS - JBOK
Compute TrayXPU: GB300 NVL725 linesshared by 1 SKU
Tray layerPart / ModelUnits per Tray
Unit BWGb/s
Lanes
Lane BWGb/s
Per switch
XPUs per TrayBlackwell 3004····
Bianca BoardNV MCIO PCIe x16 Connector2····
Bianca BoardNV MCIO PCIe x16 Cable2····
Mezz Board to OSFPNV DensiLink OverPass to OSFP Cage4····
Daughter BoardAstera Labs Scorpio-P 64-Lane PCIe Gen 5.04····
PCIe from Compute to JBOKGeneric PCIe Gen5 x16 (32Gb/s uni-di) 2-meter AEC8····

Compute Tray Parts Summary

5
ItemQty/ClusterQty/ServerAttach/XPU
NV MCIO PCIe x16 Connector65,53636.000.50
NV MCIO PCIe x16 Cable65,53636.000.50
NV DensiLink OverPass to OSFP Cage131,07272.001.00
Astera Labs Scorpio-P 64-Lane PCIe Gen 5.0131,07272.001.00
Generic PCIe Gen5 x16 (32Gb/s uni-di) 2-meter AEC262,144144.002.00