Live DB — analyst tables
Test
Oracle 4096 MI300X Pollara NIC - 400G Hyperscaler Ethernet Cluster Configuration

OCI-MI300X-Pollara-Eth-2L

Oracle · MI300X · Pollara NIC - 400G

Rack type
Cluster / location
MI300X - Infiniband Cluster
Buyer profile
Hyperscaler
Networking type
Ethernet
Number of XPUs
4,096
NIC used
Pollara NIC - 400G
NICs / XPU
1
Scale-out BW / XPU
400G
XPU / server
8

Scale-up network

Assigned blockDefault
MI300X
Scale-UpXPU: MI300X0 linesshared by 8 SKUs

Scale-up Units are based on the scale-up world size (8 XPUs).

XPU World Size

2
WS
Scale-Up Network LayerPart / Model
Units#
Unit BWGbit/s uni-d
Port Count#
Port BWGbit/s uni-d
XPUs per Node·84481432
Scale-Up World Size·83,584··

Switches

1
SW
Scale-Up Network LayerPart / Model
Units#
Unit BWGbit/s uni-d
Port Count#
Port BWGbit/s uni-d
Scale-Up Switch Total··0··

Connections & cabling

3
CN
Scale-Up Network LayerPart / Model
Units#
BW / PortGbit/s uni-d
Unit DP#
DP / Port#
Total DPs#
BW / ConnectorCable / Model
Cable Units#
Male Connectors·······Already Counted Below·
Female Connectors·······Already Counted Below·
Switch Total
Male Connectors·······Already Counted Below·
Notes
  • XPUs per Node — >>Mesh, 7x64Gb/s links per chip

Scale-Up Parts Summary

0
ItemQty/ClusterQty/ServerAttach/XPU

Backend network

7 rows
Assigned blockDefault
MI300X - Pollara - 3L - ETH - 7050PX4-32S - OCI
BackendXPU: MI300X7 linesshared by 1 SKU

Backend Units are based on the cluster size (4,096 XPUs).

Switches

5
SW
 Network Layer
Switch and Server SpecAggregate Port UtilizationNetwork Bandwidth Aggregate
SwitchPart Name / Model
Units#
Unit BWGbit/s
Port BWGbit/s
Downlink Ports / SW#
Uplink Ports / SW#
Max Ports#
Downlink Ports#
Uplink Ports#
Total Ports#
Downlink BWTbit/s
Uplink BWTbit/s
OversubRatio
XPUs·4,09640040004,0964,09604,0964,09601,638.4·
NICs per NodePollara NIC - 400G8400400··8······
ToRArista Tomahawk 3 12.8T (7050PX4-32S)25612,8004001616324,0964,0968,1921,638.41,638.41
LeafArista Tomahawk 4 25.6T (7060DX5-64S)12825,6008001616322,0482,0484,0961,638.41,638.41
SpineArista Tomahawk 4 25.6T (7060DX5-64S)6425,60080032·322,04802,0481,638.40·

Transceivers

6
CN
 Network Layer
Transceiver / CablePart Name / Model
Total Units#
Units per SW/GPU#
Unit BWGbit/s
Lanes#
BW per LaneGbit/s
Agg. BWTbit/s
XPU NodesNone - AECs are Used ->2,0482,04880081001,638.4
Leaf
DownlinkGeneric 800G SR82,0481680081001,638.4
UplinkGeneric 800G SR82,048#ERR800#ERR1000
Spine
DownlinkGeneric 800G SR82,048#ERR800#ERR1000
Uplink·······
Core
Downlink·······
Uplink·······
Super-Core
ToR
DownlinkNone - AECs are Used ->4,09684008501,638.4
UplinkGeneric 400G SR44,09684008501,638.4

Cables

6
CB
 Network Layer
Cable/ FiberType
Total Units#
Units per Transceiver#
Unit BWGbit/s
Lane Count#
SerDes BWGbit/s
XPU NodesGeneric 800G Y Cable AEC2,04818008100
Leaf
DownlinkAlready counted above·····
UplinkGeneric 400G Multimode4,09624004100
Spine
DownlinkAlready counted above·····
Uplink······
Core
Downlink······
Uplink······
Super-Core
ToR
DownlinkAlready counted above·····
UplinkGeneric 400G Multimode4,09614004100

Backend Parts Summary

7
ItemQty/ClusterQty/ServerAttach/XPU
Generic 800G Y Cable AEC2,0484.000.50
Generic 400G SR44,0968.001.00
Generic 400G Multimode8,19216.002.00
Pollara NIC - 400G4,0968.001.00
Generic 800G SR86,14412.001.50
Arista Tomahawk 3 12.8T (7050PX4-32S)2560.500.06
Arista Tomahawk 4 25.6T (7060DX5-64S)1920.380.05

Frontend network

11 rows
Assigned blockDefault
MI300X - Arista TH5 - Generic
FrontendXPU: MI300X11 linesshared by 2 SKUs

Converged Frontend + Storage Fabric

11
LayerPart / ModelUnitsAttach / XPU
·Arista Tomahawk 5 51.2T (7060X6-64PE)490.0120
·Arista Tomahawk 3 12.8T (7050PX4-32S)00.0000
·Arista Tomahawk 2 6.4T (7050CX3-32S)70.0018
·Arista Ethernet 1GbE (7048-A)600.0147
·Generic 800G DR82,3790.5807
·Generic 400G DR42,3660.5777
·Generic 100G DR4 QSFP281,0500.2563
·Generic 800G Single Mode3,2550.7947
·Generic 400G Single Mode170.0041
·Generic 100G Single Mode4680.1142
·RJ45 Cables2,8870.7048

Frontend Parts Summary

11
ItemQty/ClusterQty/ServerAttach/XPU
Arista Tomahawk 5 51.2T (7060X6-64PE)2500.0060
Arista Tomahawk 3 12.8T (7050PX4-32S)000.0000
Arista Tomahawk 2 6.4T (7050CX3-32S)400.0009
Arista Ethernet 1GbE (7048-A)3000.0073
Generic 800G DR81,18920.2904
Generic 400G DR41,18320.2888
Generic 100G DR4 QSFP2852510.1282
Generic 800G Single Mode1,62830.3974
Generic 400G Single Mode800.0020
Generic 100G Single Mode23400.0571
RJ45 Cables1,44330.3524

Compute Tray Networking Content

4 rows

Networking components inside the compute tray — accelerators, board-to-board connectors, retimers, and their per-tray bandwidth.

Assigned blockDefault
MI300X - Generic
Compute TrayXPU: MI300X4 linesshared by 8 SKUs
Tray layerPart / ModelUnits per Tray
Unit BWGb/s
Lanes
Lane BWGb/s
Per switch
XPUs per TrayRubin 2004····
PCIe 6.0 Connector (Male)Paladin Board to Board 32 Pin 4p8c (Male)2512···
PCIe 6.0 Connector (Male)Paladin Board to Board 64 Pin 4p16c (Male)81,024···
PCIe 6.0 Connector (Female)Paladin Board to Board 32 Pin 4p8c (Female)4512···
PCIe 6.0 Connector (Female)Paladin Board to Board 64 Pin 4p16c (Female)161,024···
PCIe 6.0 Connector (Male)Paladin Board to Board 32 Pin 4p8c (Male)2512···
PCIe 6.0 Connector (Male)Paladin Board to Board 64 Pin 4p16c (Male)81,024···
Notes
  • PCIe 6.0 Connector (Male) · Paladin Board to Board 32 Pin 4p8c (Male) — 2 pins = 1DP
  • PCIe 6.0 Connector (Male) · Paladin Board to Board 64 Pin 4p16c (Male) — 2DP = 1Lane

Compute Tray Parts Summary

4
ItemQty/ClusterQty/ServerAttach/XPU
Paladin Board to Board 32 Pin 4p8c (Male)4,0968.001.00
Paladin Board to Board 64 Pin 4p16c (Male)16,38432.004.00
Paladin Board to Board 32 Pin 4p8c (Female)4,0968.001.00
Paladin Board to Board 64 Pin 4p16c (Female)16,38432.004.00