Live DB — analyst tables
Test
Amazon 24576 Inferentia2 NIC - 100G Hyperscaler Ethernet Cluster Configuration

AWS-Inferentia2-Default

Amazon · Inferentia2 · NIC - 100G

Rack type
Cluster / location
Default Inferentia2
Buyer profile
Hyperscaler
Networking type
Ethernet
Number of XPUs
24,576
NIC used
NIC - 100G
NICs / XPU
0.083
Scale-out BW / XPU
8.33G
XPU / server
12

Scale-up network

Assigned blockDefault
Inferentia2
Scale-UpXPU: Inferentia20 linesshared by 1 SKU

Scale-up Units are based on the scale-up world size (12 XPUs).

XPU World Size

2
WS
Scale-Up Network LayerPart / Model
Units#
Unit BWGbit/s uni-d
Lane Count#
Lane BWGbit/s uni-d
XPUs per Node·····
Scale-Up World Size·12···

Switches

1
SW
Scale-Up Network LayerPart / Model
Units#
Unit BWGbit/s uni-d
Lane Count#
Lane BWGbit/s uni-d
per ClusterNo Scale-Up Switch····

Connections & cabling

1
CN
Scale-Up Network LayerPart / Model
Units#
BW / PortGbit/s uni-d
Unit DP#
DP / Port#
Total DPs#
BW / ConnectorCable / Model
Cable Units#
·No Connectors on the Switch Side········

Scale-Up Parts Summary

0
ItemQty/ClusterQty/ServerAttach/XPU

Backend network

6 rows
Assigned blockDefault
Inferentia2 - 100G NIC - 2L - ETH - TH2 - AWS
BackendXPU: Inferentia26 linesshared by 1 SKU

Backend Units are based on the cluster size (2,048 Number of Instances).

Switches

5
SW
 Network Layer
Switch and Server SpecAggregate Port UtilizationNetwork Bandwidth Aggregate
SwitchPart Name / Model
Units#
Unit BWGbit/s
Port BWGbit/s
Downlink Ports / SW#
Uplink Ports / SW#
Max Ports#
Downlink Ports#
Uplink Ports#
Total Ports#
Downlink BWTbit/s
Uplink BWTbit/s
OversubRatio
Number of Instances·2,04810010002,0482,04802,0482,0480204.8·
XPUs per Instance·12····8······
NICs per InstanceNIC - 100G1100100··8······
ToRWhiteBox Tomahawk 2 6.4T646,4001003232642,0482,0484,096204.8204.81
LeafWhiteBox Tomahawk 3 12.8T1612,80010012801282,04802,048204.80·

Transceivers

7
CN
 Network Layer
Transceiver / CablePart Name / Model
Total Units#
Units per SW/GPU#
Unit BWGbit/s
Lanes#
BW per LaneGbit/s
Agg. BWTbit/s
XPU NodesNone - AECs are Used ->2,048·100425204.8
CPU NodesNone - AECs are Used ->128·····
Leaf
DownlinkGeneric 100G SR4 QSFP282,048#ERR100#ERR250
UplinkGeneric 100G SR4 QSFP28······
Spine
Downlink·······
Uplink·······
Core
Downlink·······
Uplink·······
Super-Core
ToR
DownlinkNone - AECs are Used ->2,04832100425204.8
UplinkGeneric 100G SR4 QSFP282,048#ERR100#ERR250

Cables

7
CB
 Network Layer
Cable/ FiberType
Total Units#
Units per Transceiver#
Unit BWGbit/s
Lane Count#
SerDes BWGbit/s
XPU NodesGeneric 100G AEC2,0481100425
CPU Nodes······
Leaf
DownlinkAlready counted above·····
Uplink······
Spine
Downlink······
Uplink······
Core
Downlink······
Uplink······
Super-Core
ToR
DownlinkAlready counted above·····
UplinkGeneric 100G Multimode2,0481100425

Backend Parts Summary

6
ItemQty/ClusterQty/ServerAttach/XPU
Generic 100G AEC2,0481.000.08
NIC - 100G2,0481.000.08
Generic 100G SR4 QSFP284,0962.000.17
Generic 100G Multimode2,0481.000.08
WhiteBox Tomahawk 2 6.4T640.030.00
WhiteBox Tomahawk 3 12.8T160.010.00

Frontend network

No converged frontend + storage fabric data for this cluster.

Frontend Parts Summary

0
ItemQty/ClusterQty/ServerAttach/XPU