Live DB — analyst tables
Test
Neocloud Giant 93312 Rubin Ultra NVL72 CX-9 Neocloud Giant Spectrum X Cluster Configuration
NG-RU NVL72-CX9-IB-4R CPO
Neocloud Giant · Rubin Ultra · CX-9
Rack type
NVL72
Cluster / location
Default Rubin Ultra
Buyer profile
Neocloud Giant
Networking type
Spectrum X
Number of XPUs
93,312
NIC used
CX-9
NICs / XPU
4
Scale-out BW / XPU
3.2T
XPU / server
72
Scale-up network
7 rows
Assigned blockDefault
Rubin Ultra - NVL72 - Generic - 2
Scale-UpXPU: Rubin Ultra NVL727 linesshared by 8 SKUs
Scale-up Units are based on the scale-up world size (72 XPUs).
XPU World Size
2
WS| Scale-Up Network Layer | Part / Model | Units# | Unit BWGbit/s uni-d | Port Count# | Port BWGbit/s uni-d |
|---|---|---|---|---|---|
| XPUs per Node | · | 4 | 14,400 | 72 | 200 |
| Scale-Up World Size | · | 72 | 1,036,800 | · | · |
Switches
3
SW| Scale-Up Network Layer | Part / Model | Units# | Unit BWGbit/s uni-d | Port Count# | Port BWGbit/s uni-d |
|---|---|---|---|---|---|
| per Switch | Nvidia NVSwitch 7.0 (NVLink 7) - 28.8T | 1 | 28,800 | 144 | 200 |
| Layer 1 Switches | Nvidia NVSwitch 7.0 (NVLink 7) - 28.8T | 36 | 1,036,800 | 144 | 200 |
| Scale-Up Switch Total | · | 36 | 1,036,800 | · | · |
Connections & cabling
12
CN| Scale-Up Network Layer | Part / Model | Units# | BW / PortGbit/s uni-d | Ports# | Bidi / Port# | Total BW# | BW / Connector | Cable / Model | Cable Units# |
|---|---|---|---|---|---|---|---|---|---|
| Optical Engines | NV 3.2T Optical Engine (OE) for NVLink Switch side CPO | · | 200 | 16 | · | 0 | 3,200 | NV 1.6T 8 Fiber Pair FAU | 0 |
| External Laser Source | NV External Laser Source (ELS) 8 LD 6.4T for NVLink CPO Switch | 0 | 200 | 32 | · | 0 | 6,400 | · | · |
| L2 Switch Total | |||||||||
| Male Connectors to GPU | NV Sentry HD 448Gb/s 144DP (Male) | 36 | 200 | 144 | · | 1,036,800 | 28,800 | Already Counted Below | · |
| Female Connectors to GPU | NV Sentry HD 448Gb/s 144DP (Female) | 36 | 200 | 144 | · | 1,036,800 | 28,800 | · | · |
| Optical Engines | NV 3.2T Optical Engine (OE) for NVLink Switch side CPO | · | 200 | 16 | · | 0 | 3,200 | NV 1.6T 8 Fiber Pair FAU | 0 |
| External Laser Source | NV External Laser Source (ELS) 8 LD 6.4T for NVLink CPO Switch | 0 | 200 | 32 | · | 0 | 6,400 | · | · |
| L1 Switch Total | · | · | · | · | · | · | 6,400 | · | · |
| Male Connectors | NV Sentry HD 448Gb/s 72DP (Male) | 72 | 200 | 72 | · | 1,036,800 | 14,400 | Uses a Midplane PCB to connect to NVSwitch Chips | · |
| Female Connectors | NV Sentry HD 448Gb/s 72DP (Female) | 72 | 200 | 72 | · | 1,036,800 | 14,400 | Uses a Midplane PCB to connect to NVSwitch Chips | · |
| XPU Total | ** One connector per GPU | · | · | · | · | · | 14,400 | · | · |
| · | NVL Blade Column Spine Chassis (NvLink 7) | · | · | · | · | · | · | NV 224Gb/s SkewClear EXD Gen 2 Bidi Cable | 5,184 |
| · | NVL Kyber Canister Midplane PCB (NvLink 7) | 0 | · | · | · | · | · | · | · |
Scale-Up Parts Summary
7
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia NVSwitch 7.0 (NVLink 7) - 28.8T | 46,656 | 36.00 | 0.50 |
| NV Sentry HD 448Gb/s 144DP (Male) | 46,656 | 36.00 | 0.50 |
| NV Sentry HD 448Gb/s 144DP (Female) | 46,656 | 36.00 | 0.50 |
| NV Sentry HD 448Gb/s 72DP (Male) | 93,312 | 72.00 | 1.00 |
| NV Sentry HD 448Gb/s 72DP (Female) | 93,312 | 72.00 | 1.00 |
| NVL Blade Column Spine Chassis (NvLink 7) | 6,718,464 | 5,184.00 | 72.00 |
| NV 224Gb/s SkewClear EXD Gen 2 Bidi Cable | 6,718,464 | 5,184.00 | 72.00 |
Backend network
4 rows
Assigned blockDefault
Rubin Ultra - NVL72 - CX9 - 3L - IB - X800-Q3450 CPO - Generic
BackendXPU: Rubin Ultra NVL724 linesshared by 2 SKUs
Backend Units are based on the cluster size (93,312 XPUs).
Switches
5
SW Network Layer | Switch and Server Spec | Aggregate Port Utilization | Network Bandwidth Aggregate | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SwitchPart Name / Model | Units# | Unit BWGbit/s | Port BWGbit/s | Downlink Ports / SW# | Uplink Ports / SW# | Max Ports# | Downlink Ports# | Uplink Ports# | Total Ports# | Downlink BWTbit/s | Uplink BWTbit/s | OversubRatio | |
| XPUs | · | 93,312 | 3,200 | 3,200 | 0 | 93,312 | 93,312 | 0 | 93,312 | 93,312 | 0 | 298,598.4 | · |
| NICs per Node | ConnectX-9 NIC - 800G | 16 | 800 | 100 | · | · | 8 | · | · | · | · | · | · |
| Leaf | Quantum-X800-Q3450 CPO | 5,184 | 115,200 | 800 | 72 | 72 | 144 | 373,248 | 373,248 | 746,496 | 298,598.4 | 298,598.4 | 1 |
| Spine | Quantum-X800-Q3450 CPO | 5,184 | 115,200 | 800 | 72 | 72 | 144 | 373,248 | 373,248 | 746,496 | 298,598.4 | 298,598.4 | 1 |
| Core | Quantum-X800-Q3450 CPO | 2,592 | 115,200 | 800 | 144 | · | 144 | 373,248 | 0 | 373,248 | 298,598.4 | 0 | · |
Transceivers
7
CN Network Layer | Transceiver / CablePart Name / Model | Total Units# | Units per SW/GPU# | Unit BWGbit/s | Lanes# | BW per LaneGbit/s | Agg. BWTbit/s |
|---|---|---|---|---|---|---|---|
| XPU Nodes | Nvidia LinkX 1.6T DR8 (SiPho) | 93,312 | 93,312 | 1,600 | 8 | 200 | 149,299.2 |
| Leaf | |||||||
| Downlink | Nvidia LinkX 1.6T DR8 (SiPho) | 0 | 0 | 1,600 | 8 | 200 | 0 |
| Uplink | Nvidia LinkX 1.6T DR8 (SiPho) | 0 | 0 | 1,600 | 8 | 200 | 0 |
| Spine | |||||||
| Downlink | Nvidia LinkX 1.6T DR8 (SiPho) | 0 | 0 | 1,600 | 8 | 200 | 0 |
| Uplink | Nvidia LinkX 1.6T DR8 (SiPho) | 0 | 0 | 1,600 | 8 | 200 | 0 |
| Core | |||||||
| Downlink | Nvidia LinkX 1.6T DR8 (SiPho) | 0 | 0 | 1,600 | 8 | 200 | 0 |
| Uplink | · | · | · | · | · | · | · |
| Super-Core | This configuration uses CPO - so there will be no transceivers in switches | · | · | · | · | · | · |
Cables
7
CB Network Layer | Cable/ FiberType | Total Units# | Units per Transceiver# | Unit BWGbit/s | Lane Count# | SerDes BWGbit/s |
|---|---|---|---|---|---|---|
| XPU Nodes | Nvidia LinkX 800G Single Mode | 186,624 | 2 | 800 | 4 | 200 |
| Leaf | ||||||
| Downlink | Already counted above | · | · | · | · | · |
| Uplink | Nvidia LinkX 800G Single Mode | 186,624 | 7 | 800 | 4 | 200 |
| Spine | ||||||
| Downlink | Already counted above | · | · | · | · | · |
| Uplink | Nvidia LinkX 800G Single Mode | 186,624 | 7 | 800 | 4 | 200 |
| Core | ||||||
| Downlink | Already counted above | · | · | · | · | · |
| Uplink | · | · | · | · | · | · |
| Super-Core | · | · | · | · | · | · |
Backend Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia LinkX 1.6T DR8 (SiPho) | 93,312 | 72.00 | 1.00 |
| Nvidia LinkX 800G Single Mode | 559,872 | 432.00 | 6.00 |
| ConnectX-9 NIC - 800G | 373,248 | 288.00 | 4.00 |
| Quantum-X800-Q3450 CPO | 12,960 | 10.00 | 0.14 |
Frontend network
11 rows
Assigned blockDefault
Rubin Ultra - NVL72 - SN6600 - Generic
FrontendXPU: Rubin Ultra NVL7211 linesshared by 11 SKUs
Converged Frontend + Storage Fabric
11
| Layer | Part / Model | Units | Attach / XPU |
|---|---|---|---|
| · | Spectrum-6 102.4T x1600 (SN6600) | 1,120 | 0.0120 |
| · | Spectrum-4 25.6T (SN5400) | 5 | 0.0000 |
| · | Spectrum-3 12.8T (SN4700) | 167 | 0.0018 |
| · | Spectrum-2 6.4T (SN3700) | 1,370 | 0.0147 |
| · | Nvidia LinkX 1.6T DR8 (SiPho) | 54,187 | 0.5807 |
| · | Nvidia LinkX 800G DR4 | 53,904 | 0.5777 |
| · | Nvidia LinkX 200G SR4 | 23,920 | 0.2563 |
| · | Nvidia LinkX 800G Multimode | 74,159 | 0.7947 |
| · | Nvidia LinkX 400G Multimode | 380 | 0.0041 |
| · | Nvidia LinkX 200G Multimode | 10,655 | 0.1142 |
| · | RJ45 Cables | 65,763 | 0.7048 |
Frontend Parts Summary
11
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Spectrum-6 102.4T x1600 (SN6600) | 1,120 | 1 | 0.0120 |
| Spectrum-4 25.6T (SN5400) | 5 | 0 | 0.0001 |
| Spectrum-3 12.8T (SN4700) | 167 | 0 | 0.0018 |
| Spectrum-2 6.4T (SN3700) | 1,370 | 1 | 0.0147 |
| Nvidia LinkX 1.6T DR8 (SiPho) | 54,187 | 42 | 0.5807 |
| Nvidia LinkX 800G DR4 | 53,904 | 42 | 0.5777 |
| Nvidia LinkX 200G SR4 | 23,920 | 18 | 0.2563 |
| Nvidia LinkX 800G Multimode | 74,159 | 57 | 0.7947 |
| Nvidia LinkX 400G Multimode | 380 | 0 | 0.0041 |
| Nvidia LinkX 200G Multimode | 10,655 | 8 | 0.1142 |
| RJ45 Cables | 65,763 | 51 | 0.7048 |
Compute Tray Networking Content
4 rows
Networking components inside the compute tray — accelerators, board-to-board connectors, retimers, and their per-tray bandwidth.
Assigned blockDefault
Rubin Ultra - NVL72 - Generic
Compute TrayXPU: Rubin Ultra NVL724 linesshared by 11 SKUs
| Tray layer | Part / Model | Units per Tray | Unit BWGb/s | Lanes | Lane BWGb/s | Per switch |
|---|---|---|---|---|---|---|
| XPUs per Tray | Rubin 200 | 4 | · | · | · | · |
| PCIe 6.0 Connector (Male) | NV Paladin Board to Board 32 Pin 4p8c (Male) | 2 | 512 | · | · | · |
| PCIe 6.0 Connector (Male) | NV Paladin Board to Board 64 Pin 4p16c (Male) | 8 | 1,024 | · | · | · |
| PCIe 6.0 Connector (Female) | NV Paladin Board to Board 32 Pin 4p8c (Female) | 4 | 512 | · | · | · |
| PCIe 6.0 Connector (Female) | NV Paladin Board to Board 64 Pin 4p16c (Female) | 16 | 1,024 | · | · | · |
| PCIe 6.0 Connector (Male) | NV Paladin Board to Board 32 Pin 4p8c (Male) | 2 | 512 | · | · | · |
| PCIe 6.0 Connector (Male) | NV Paladin Board to Board 64 Pin 4p16c (Male) | 8 | 1,024 | · | · | · |
Notes
- PCIe 6.0 Connector (Male) · NV Paladin Board to Board 32 Pin 4p8c (Male) — 2 pins = 1DP
- PCIe 6.0 Connector (Male) · NV Paladin Board to Board 64 Pin 4p16c (Male) — 2DP = 1Lane
Compute Tray Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| NV Paladin Board to Board 32 Pin 4p8c (Male) | 93,312 | 72.00 | 1.00 |
| NV Paladin Board to Board 64 Pin 4p16c (Male) | 373,248 | 288.00 | 4.00 |
| NV Paladin Board to Board 32 Pin 4p8c (Female) | 93,312 | 72.00 | 1.00 |
| NV Paladin Board to Board 64 Pin 4p16c (Female) | 373,248 | 288.00 | 4.00 |