Live DB — analyst tables
Test
Amazon 131072 Teton3 PD Nitro-v6 Hyperscaler Ethernet Cluster Configuration
AWS-Teton3 PD-Nv6-EFA-WB
Amazon · Trainium3 · Nitro-v6
Rack type
Teton3 PD
Cluster / location
AWS Teton3 PD Cluster
Buyer profile
Hyperscaler
Networking type
Ethernet
Number of XPUs
131,072
NIC used
Nitro-v6
NICs / XPU
1.031
Scale-out BW / XPU
412.5G
XPU / server
64
Scale-up network
4 rows
Assigned blockDefault
Trainium3 - Teton3 PD
Scale-UpXPU: Trainium3 Teton3 PD4 linesshared by 1 SKU
Scale-up Units are based on the scale-up world size (64 XPUs).
XPU World Size
2
WS| Scale-Up Network Layer | Part / Model | Units# | Unit BWGbit/s uni-d | Lane Count# | Lane BWGbit/s uni-d |
|---|---|---|---|---|---|
| XPUs per Node | · | 16 | · | · | · |
| Scale-Up World Size | · | 64 | 0 | · | · |
Switches
2
SW| Scale-Up Network Layer | Part / Model | Units# | Unit BWGbit/s uni-d | Lane Count# | Lane BWGbit/s uni-d |
|---|---|---|---|---|---|
| per Cluster | No Scale-Up Switch | 0 | · | · | · |
| Scale-Up Switch Total | · | · | 0 | · | · |
Connections & cabling
5
CN| Scale-Up Network Layer | Part / Model | Units# | BW / LaneGbit/s uni-d | Unit DP# | DP / Lane# | Total DPs# | BW / Connector | Cable / Model | Cable Units# |
|---|---|---|---|---|---|---|---|---|---|
| · | No Connectors on the Switch Side | · | · | · | · | · | · | · | · |
| · | Strada Whisper 112Gb/s 64 DP Absolute Connector (Male) | 192 | 64 | 64 | 2 | 12,288 | · | · | · |
| · | Strada Whisper 112Gb/s 64 DP Absolute Connector (Female) | 192 | 64 | 64 | 2 | 12,288 | · | 112Gb/s TE Connectivity Madison Cable (1DP per cable) | 6,144 |
| Switch Total | |||||||||
| XPU Total | ***Connectors between XPU Trays | · | · | · | · | · | · | · | · |
| · | Teton3 Backplane Chassis | 4 | · | · | · | · | · | · | · |
PCIe Lane Math
PCIe Lane Math
12
PCIe lane accounting for the Trainium scale-up domain. Values behave like spreadsheet cells: type = to start a formula, then click other Value cells to link them (hard-coded values read blue, pure cell links read white).
| Section | Metric | Value# | Note |
|---|---|---|---|
| · | DP per Lane | 2 | · |
| (a) | Number of Chips | 64 | · |
| · | DP per Connector Pair | 64 | · |
| · | Strada Whisper Units per (a) | 192 | · |
| (a) | Number of Chips | 64 | · |
| · | AEC Lanes per Chip | 0 | · |
| · | Lanes per AEC | 0 | · |
| · | AEC Units per (a) | 0 | · |
| · | Backplane Lanes | 96 | · |
| · | AEC Lanes | 0 | · |
| · | PCB Lanes | 32 | · |
| · | Total Lanes | 128 | · |
Scale-Up Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Strada Whisper 112Gb/s 64 DP Absolute Connector (Male) | 393,216 | 192.00 | 3.00 |
| Strada Whisper 112Gb/s 64 DP Absolute Connector (Female) | 393,216 | 192.00 | 3.00 |
| 112Gb/s TE Connectivity Madison Cable (1DP per cable) | 12,582,912 | 6,144.00 | 96.00 |
| Teton3 Backplane Chassis | 8,192 | 4.00 | 0.06 |
Backend network
7 rows
Assigned blockDefault
Trainium3 - Teton3 PD - EFAv4 - 3L - ETH - TH3 - AWS
BackendXPU: Trainium3 Teton3 PD7 linesshared by 1 SKU
Backend Units are based on the cluster size (131,072 XPUs).
Switches
5
SW Network Layer | Switch and Server Spec | Aggregate Port Utilization | Network Bandwidth Aggregate | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SwitchPart Name / Model | Units# | Unit BWGbit/s | Port BWGbit/s | Downlink Ports / SW# | Uplink Ports / SW# | Max Ports# | Downlink Ports# | Uplink Ports# | Total Ports# | Downlink BWTbit/s | Uplink BWTbit/s | OversubRatio | |
| XPUs | · | 131,072 | 412.5 | 200 | 0 | 270,336 | 270,336 | 0 | 270,336 | 270,336 | 0 | 54,067.2 | · |
| NICs per Node | EFAv4 Nitro-v6 400G NIC | 17 | 400 | 200 | · | · | 8 | · | · | · | · | · | · |
| ToR | WhiteBox Tomahawk 3 12.8T | 8,448 | 12,800 | 400 | 16 | 16 | 32 | 135,168 | 135,168 | 270,336 | 54,067.2 | 54,067.2 | 1 |
| Leaf | WhiteBox Tomahawk 5 51.2T | 2,112 | 51,200 | 400 | 64 | 64 | 128 | 135,168 | 135,168 | 270,336 | 54,067.2 | 54,067.2 | 1 |
| Spine | WhiteBox Tomahawk 5 51.2T | 1,056 | 51,200 | 400 | 128 | 0 | 128 | 135,168 | 0 | 135,168 | 54,067.2 | 0 | · |
Transceivers
8
CN Network Layer | Transceiver / CablePart Name / Model | Total Units# | Units per SW/GPU# | Unit BWGbit/s | Lanes# | BW per LaneGbit/s | Agg. BWTbit/s |
|---|---|---|---|---|---|---|---|
| XPU Nodes | None - AECs are Used -> | 131,072 | 131,072 | 412.5 | 4 | 103.125 | 54,067.2 |
| CPU Nodes | None - AECs are Used -> | 8,192 | · | · | · | · | · |
| Leaf | |||||||
| Downlink | Generic 800G DR8 | 67,584 | 32 | 800 | 8 | 100 | 54,067.2 |
| Uplink | Generic 800G DR8 | 67,584 | #ERR | 800 | #ERR | 100 | 0 |
| Spine | |||||||
| Downlink | Generic 800G DR8 | 67,584 | #ERR | 800 | #ERR | 100 | 0 |
| Uplink | · | · | · | · | · | · | · |
| Core | |||||||
| Downlink | · | · | · | · | · | · | · |
| Uplink | · | · | · | · | · | · | · |
| Super-Core | |||||||
| ToR | |||||||
| Downlink | None - AECs are Used -> | 135,168 | 8 | 400 | 8 | 100 | 54,067.2 |
| Uplink | Generic 400G DR4 | 135,168 | 8 | 400 | 8 | 100 | 54,067.2 |
Cables
8
CB Network Layer | Cable/ FiberType | Total Units# | Units per Transceiver# | Unit BWGbit/s | Lane Count# | SerDes BWGbit/s |
|---|---|---|---|---|---|---|
| XPU Nodes | Generic 400G AEC | 135,168 | 1.031 | 400 | 4 | 100 |
| CPU Nodes | · | · | · | · | · | · |
| Leaf | ||||||
| Downlink | Already counted above | · | · | · | · | · |
| Uplink | Generic 400G Single Mode | 135,168 | 2 | 400 | 4 | 100 |
| Spine | ||||||
| Downlink | · | · | · | · | · | · |
| Uplink | · | · | · | · | · | · |
| Core | ||||||
| Downlink | · | · | · | · | · | · |
| Uplink | · | · | · | · | · | · |
| Super-Core | ||||||
| ToR | ||||||
| Downlink | Already counted above | · | · | · | · | · |
| Uplink | Generic 400G Single Mode | 135,168 | 1 | 400 | 4 | 100 |
Backend Parts Summary
7
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Generic 400G AEC | 135,168 | 66.00 | 1.03 |
| EFAv4 Nitro-v6 400G NIC | 139,264 | 68.00 | 1.06 |
| Generic 400G DR4 | 135,168 | 66.00 | 1.03 |
| Generic 400G Single Mode | 270,336 | 132.00 | 2.06 |
| WhiteBox Tomahawk 3 12.8T | 8,448 | 4.13 | 0.06 |
| Generic 800G DR8 | 202,752 | 99.00 | 1.55 |
| WhiteBox Tomahawk 5 51.2T | 3,168 | 1.55 | 0.02 |
Frontend network
No converged frontend + storage fabric data for this cluster.
Frontend Parts Summary
0
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|
Compute Tray Networking Content
2 rows
Networking components inside the compute tray — accelerators, board-to-board connectors, retimers, and their per-tray bandwidth.
Assigned blockDefault
Trainium3 - Teton3 PD - AWS
Compute TrayXPU: Trainium3 Teton3 PD2 linesshared by 1 SKU
| Tray layer | Part / Model | Units per Tray | Unit BWGb/s | Lanes | Lane BWGb/s | Per switch |
|---|---|---|---|---|---|---|
| XPUs per Tray | Trainium3 | 2 | · | · | · | · |
| · | Aries PCIe 6.0 x16 Retimer | 2 | 512 | · | · | · |
| · | 200G EFAv4 QSFP56 Flat Top DAC | 0.5 | 200 | · | · | · |
Compute Tray Parts Summary
2
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Aries PCIe 6.0 x16 Retimer | 131,072 | 64.00 | 1.00 |
| 200G EFAv4 QSFP56 Flat Top DAC | 32,768 | 16.00 | 0.25 |