Live DB — analyst tables
Test
Amazon 131072 Teton3 PD Ultra Nitro-v6 Hyperscaler Ethernet Cluster Configuration

AWS-Teton3 PD Ultra-Nv6-EFA

Amazon · Trainium3 · Nitro-v6

Rack type
Teton3 PD Ultra
Cluster / location
AWS Teton3 PD Ultra Cluster
Buyer profile
Hyperscaler
Networking type
Ethernet
Number of XPUs
131,072
NIC used
Nitro-v6
NICs / XPU
1.031
Scale-out BW / XPU
412.5G
XPU / server
64

Scale-up network

5 rows
Assigned blockDefault
Trainium3 - Teton3 PD Ultra
Scale-UpXPU: Trainium3 Teton3 PD Ultra5 linesshared by 1 SKU

Scale-up Units are based on the scale-up world size (64 XPUs).

XPU World Size

2
WS
Scale-Up Network LayerPart / Model
Units#
Unit BWGbit/s uni-d
Lane Count#
Lane BWGbit/s uni-d
XPUs per Node·16···
Scale-Up World Size·640··

Switches

2
SW
Scale-Up Network LayerPart / Model
Units#
Unit BWGbit/s uni-d
Lane Count#
Lane BWGbit/s uni-d
per ClusterNo Scale-Up Switch0···
Scale-Up Switch Total··0··

Connections & cabling

4
CN
Scale-Up Network LayerPart / Model
Units#
BW / LaneGbit/s uni-d
Unit DP#
DP / Lane#
Total DPs#
BW / ConnectorCable / Model
Cable Units#
·Strada Whisper 112Gb/s 64 DP Absolute Connector (Male)1923264212,288···
·Strada Whisper 112Gb/s 64 DP Absolute Connector (Female)1923264212,288·112Gb/s TE Connectivity Madison Cable (1DP per cable)6,144
·Generic PCIe Gen6 x16 (128Gb/s uni-di) 2-meter AEC64·······
·Teton3 Backplane Chassis4·······

PCIe Lane Math

PCIe Lane Math
10

PCIe lane accounting for the Trainium scale-up domain. Values behave like spreadsheet cells: type = to start a formula, then click other Value cells to link them (hard-coded values read blue, pure cell links read white).

SectionMetric
Value#
Note
·DP per Connector Pair64·
·Strada Whisper Units per (a)192·
(a)Number of Chips64·
·AEC Lanes per Chip32·
·Lanes per AEC16·
·AEC Units per (a)64·
·Backplane Lanes96·
·AEC Lanes32·
·PCB Lanes32·
·Total Lanes per Trainium160·

Scale-Up Parts Summary

5
ItemQty/ClusterQty/ServerAttach/XPU
Strada Whisper 112Gb/s 64 DP Absolute Connector (Male)393,216192.003.00
Strada Whisper 112Gb/s 64 DP Absolute Connector (Female)393,216192.003.00
112Gb/s TE Connectivity Madison Cable (1DP per cable)12,582,9126,144.0096.00
Generic PCIe Gen6 x16 (128Gb/s uni-di) 2-meter AEC131,07264.001.00
Teton3 Backplane Chassis8,1924.000.06

Backend network

7 rows
Assigned blockDefault
Trainium3 - Teton3 PD Ultra - EFAv4 - 3L - ETH - TH3 - AWS
BackendXPU: Trainium3 Teton3 PD Ultra7 linesshared by 1 SKU

Backend Units are based on the cluster size (131,072 XPUs).

Switches

5
SW
 Network Layer
Switch and Server SpecAggregate Port UtilizationNetwork Bandwidth Aggregate
SwitchPart Name / Model
Units#
Unit BWGbit/s
Port BWGbit/s
Downlink Ports / SW#
Uplink Ports / SW#
Max Ports#
Downlink Ports#
Uplink Ports#
Total Ports#
Downlink BWTbit/s
Uplink BWTbit/s
OversubRatio
XPUs·131,072412.52000270,336270,3360270,336270,336054,067.2·
NICs per NodeEFAv4 Nitro-v6 400G NIC17400200··8······
ToRWhiteBox Tomahawk 3 12.8T8,44812,800400161632135,168135,168270,33654,067.254,067.21
LeafWhiteBox Tomahawk 5 51.2T2,11251,2004006464128135,168135,168270,33654,067.254,067.21
SpineWhiteBox Tomahawk 5 51.2T1,05651,2004001280128135,1680135,16854,067.20·

Transceivers

8
CN
 Network Layer
Transceiver / CablePart Name / Model
Total Units#
Units per SW/GPU#
Unit BWGbit/s
Lanes#
BW per LaneGbit/s
Agg. BWTbit/s
XPU NodesNone - AECs are Used ->131,072131,072412.54103.12554,067.2
CPU NodesNone - AECs are Used ->8,192·····
Leaf
DownlinkGeneric 800G DR867,58432800810054,067.2
UplinkGeneric 800G DR867,584#ERR800#ERR1000
Spine
DownlinkGeneric 800G DR867,584#ERR800#ERR1000
Uplink·······
Core
Downlink·······
Uplink·······
Super-Core
ToR
DownlinkNone - AECs are Used ->135,1688400810054,067.2
UplinkGeneric 400G DR4135,1688400810054,067.2

Cables

8
CB
 Network Layer
Cable/ FiberType
Total Units#
Units per Transceiver#
Unit BWGbit/s
Lane Count#
SerDes BWGbit/s
XPU NodesGeneric 400G AEC135,1681.0314004100
CPU Nodes······
Leaf
DownlinkAlready counted above·····
UplinkGeneric 400G Single Mode135,16824004100
Spine
Downlink······
Uplink······
Core
Downlink······
Uplink······
Super-Core
ToR
DownlinkAlready counted above·····
UplinkGeneric 400G Single Mode135,16814004100

Backend Parts Summary

7
ItemQty/ClusterQty/ServerAttach/XPU
Generic 400G AEC135,16866.001.03
EFAv4 Nitro-v6 400G NIC139,26468.001.06
Generic 400G DR4135,16866.001.03
Generic 400G Single Mode270,336132.002.06
WhiteBox Tomahawk 3 12.8T8,4484.130.06
Generic 800G DR8202,75299.001.55
WhiteBox Tomahawk 5 51.2T3,1681.550.02

Frontend network

No converged frontend + storage fabric data for this cluster.

Frontend Parts Summary

0
ItemQty/ClusterQty/ServerAttach/XPU

Compute Tray Networking Content

2 rows

Networking components inside the compute tray — accelerators, board-to-board connectors, retimers, and their per-tray bandwidth.

Assigned blockDefault
Trainium3 - Teton3 PD Ultra - AWS
Compute TrayXPU: Trainium3 Teton3 PD Ultra2 linesshared by 1 SKU
Tray layerPart / ModelUnits per Tray
Unit BWGb/s
Lanes
Lane BWGb/s
Per switch
XPUs per TrayTrainium22····
·Aries PCIe 5.0 x16 Retimer4512···
·200G EFAv3 QSFP56 Flat Top DAC0.5200···

Compute Tray Parts Summary

2
ItemQty/ClusterQty/ServerAttach/XPU
Aries PCIe 5.0 x16 Retimer262,144128.002.00
200G EFAv3 QSFP56 Flat Top DAC32,76816.000.25