Meta 24576 MTIA Gen 2 NIC - 200G Hyperscaler Ethernet Cluster Configuration
META-MTIA Gen 2-200G-Eth-3L
Meta · MTIA Gen 2 · NIC - 200G
Rack type
—
Cluster / location
24k Ethernet Cluster
Buyer profile
Hyperscaler
Networking type
Ethernet
Number of XPUs
24,576
NIC used
NIC - 200G
NICs / XPU
0.333
Scale-out BW / XPU
33.33G
XPU / server
24
Scale-up network
1 rows
Assigned blockDefault
MTIA Gen 2
Scale-UpXPU: MTIA Gen 21 lineshared by 1 SKU
Scale-up Units are based on the scale-up world size (24 XPUs).
XPU World Size
2
WS| Scale-Up Network Layer | Part / Model | Units# | Unit BWGbit/s uni-d | Lane Count# | Lane BWGbit/s uni-d |
|---|---|---|---|---|---|
| XPUs per Node | · | 12 | 256 | 8 | 32 |
| Scale-Up World Size | · | 24 | 6,144 | · | · |
Switches
4
SW| Scale-Up Network Layer | Part / Model | Units# | Unit BWGbit/s uni-d | Lane Count# | Lane BWGbit/s uni-d |
|---|---|---|---|---|---|
| · | · | · | · | · | · |
| · | · | · | · | · | · |
| per Switch | 96-Lane PCIe Gen 5.0 Switch for MTIA | 2 | 3,072 | 96 | 32 |
| Scale-Up Switch Total | · | · | 6,144 | · | · |
Notes
- XPUs per Node — >>12 modules per chassis
- Scale-Up World Size — >>3 chassis per rack
- >>72 MTIA ASICs per rack
- >>2 MTIA ASICs per module
Scale-Up Parts Summary
1
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| 96-Lane PCIe Gen 5.0 Switch for MTIA | 2,048 | 2.00 | 0.08 |
Backend network
4 rows
Assigned blockDefault
MTIA Gen 2 - 200G NIC - 3L - ETH - Minipack-1 OCP Rack - META
BackendXPU: MTIA Gen 24 linesshared by 1 SKU
Backend Units are based on the cluster size (24,576 XPUs).
Switches
6
SW Network Layer | Switch and Server Spec | Aggregate Port Utilization | Network Bandwidth Aggregate | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SwitchPart Name / Model | Units# | Unit BWGbit/s | Port BWGbit/s | Downlink Ports / SW# | Uplink Ports / SW# | Max Ports# | Downlink Ports# | Uplink Ports# | Total Ports# | Downlink BWTbit/s | Uplink BWTbit/s | OversubRatio | |
| XPUs | · | 24,576 | 33.333 | · | · | 4,096 | 4,096 | · | 4,096 | 4,096 | 0 | 0 | · |
| XPUs per Chassis | · | 24 | 33.333 | · | · | · | · | · | · | · | · | · | · |
| NICs per Chassis | NIC - 200G | 4 | 200 | 200 | · | · | · | · | · | · | · | · | · |
| Leaf | Minipack-1 OCP Rack 12.8T | 128 | 12,800 | 200 | 32 | 32 | 64 | 4,096 | 4,096 | 8,192 | 819.2 | 819.2 | 1 |
| Spine | Minipack-1 OCP Rack 12.8T | 128 | 12,800 | 200 | 32 | 32 | 64 | 4,096 | 4,096 | 8,192 | 819.2 | 819.2 | 1 |
| Core | Minipack-1 OCP Rack 12.8T | 64 | 12,800 | 200 | 64 | 0 | 64 | 4,096 | 0 | 4,096 | 819.2 | 0 | · |
Transceivers
6
CN Network Layer | Transceiver / CablePart Name / Model | Total Units# | Units per SW/GPU# | Unit BWGbit/s | Lanes# | BW per LaneGbit/s | Agg. BWTbit/s |
|---|---|---|---|---|---|---|---|
| Leaf | |||||||
| Downlink | Generic 200G DR4 QSFP56 | 4,096 | 32 | 200 | 4 | 50 | 819.2 |
| Uplink | Generic 200G DR4 QSFP56 | 4,096 | #ERR | 200 | #ERR | 50 | 0 |
| Spine | |||||||
| Downlink | Generic 200G DR4 QSFP56 | 4,096 | 32 | 200 | 4 | 50 | 819.2 |
| Uplink | Generic 200G DR4 QSFP56 | 4,096 | #ERR | 200 | #ERR | 50 | 0 |
| Core | |||||||
| Downlink | Generic 200G DR4 QSFP56 | 4,096 | #ERR | 200 | #ERR | 50 | 0 |
| Uplink | · | · | · | · | · | · | · |
| Super-Core | |||||||
| 200G NICs | |||||||
| 200G NICs | Generic 200G DR4 QSFP56 | 4,096 | #ERR | 200 | #ERR | 50 | 0 |
Cables
6
CB Network Layer | Cable/ FiberType | Total Units# | Units per Transceiver# | Unit BWGbit/s | Lane Count# | SerDes BWGbit/s |
|---|---|---|---|---|---|---|
| Leaf | ||||||
| Downlink | Already counted above | · | · | · | · | · |
| Uplink | Generic 200G Single Mode | 4,096 | 1 | 200 | 4 | 50 |
| Spine | ||||||
| Downlink | Already counted above | · | · | · | · | · |
| Uplink | Generic 200G Single Mode | 4,096 | 1 | 200 | 4 | 50 |
| Core | ||||||
| Downlink | Already counted above | · | · | · | · | · |
| Uplink | · | · | · | · | · | · |
| Super-Core | ||||||
| 200G NICs | ||||||
| 200G NICs | Generic 200G Single Mode | 4,096 | 1 | 200 | 4 | 50 |
Backend Parts Summary
4
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Generic 200G DR4 QSFP56 | 24,576 | 24.00 | 1.00 |
| Generic 200G Single Mode | 12,288 | 12.00 | 0.50 |
| NIC - 200G | 8,192 | 8.00 | 0.33 |
| Minipack-1 OCP Rack 12.8T | 320 | 0.31 | 0.01 |
Frontend network
No converged frontend + storage fabric data for this cluster.
Frontend Parts Summary
0
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|