Live DB — analyst tables
Test
Meta 24576 MTIA Gen 2 NIC - 200G Hyperscaler Ethernet Cluster Configuration

META-MTIA Gen 2-200G-Eth-3L

Meta · MTIA Gen 2 · NIC - 200G

Rack type
Cluster / location
24k Ethernet Cluster
Buyer profile
Hyperscaler
Networking type
Ethernet
Number of XPUs
24,576
NIC used
NIC - 200G
NICs / XPU
0.333
Scale-out BW / XPU
33.33G
XPU / server
24

Scale-up network

1 rows
Assigned blockDefault
MTIA Gen 2
Scale-UpXPU: MTIA Gen 21 lineshared by 1 SKU

Scale-up Units are based on the scale-up world size (24 XPUs).

XPU World Size

2
WS
Scale-Up Network LayerPart / Model
Units#
Unit BWGbit/s uni-d
Lane Count#
Lane BWGbit/s uni-d
XPUs per Node·12256832
Scale-Up World Size·246,144··

Switches

4
SW
Scale-Up Network LayerPart / Model
Units#
Unit BWGbit/s uni-d
Lane Count#
Lane BWGbit/s uni-d
······
······
per Switch96-Lane PCIe Gen 5.0 Switch for MTIA23,0729632
Scale-Up Switch Total··6,144··
Notes
  • XPUs per Node — >>12 modules per chassis
  • Scale-Up World Size — >>3 chassis per rack
  • >>72 MTIA ASICs per rack
  • >>2 MTIA ASICs per module

Scale-Up Parts Summary

1
ItemQty/ClusterQty/ServerAttach/XPU
96-Lane PCIe Gen 5.0 Switch for MTIA2,0482.000.08

Backend network

4 rows
Assigned blockDefault
MTIA Gen 2 - 200G NIC - 3L - ETH - Minipack-1 OCP Rack - META
BackendXPU: MTIA Gen 24 linesshared by 1 SKU

Backend Units are based on the cluster size (24,576 XPUs).

Switches

6
SW
 Network Layer
Switch and Server SpecAggregate Port UtilizationNetwork Bandwidth Aggregate
SwitchPart Name / Model
Units#
Unit BWGbit/s
Port BWGbit/s
Downlink Ports / SW#
Uplink Ports / SW#
Max Ports#
Downlink Ports#
Uplink Ports#
Total Ports#
Downlink BWTbit/s
Uplink BWTbit/s
OversubRatio
XPUs·24,57633.333··4,0964,096·4,0964,09600·
XPUs per Chassis·2433.333··········
NICs per ChassisNIC - 200G4200200·········
LeafMinipack-1 OCP Rack 12.8T12812,8002003232644,0964,0968,192819.2819.21
SpineMinipack-1 OCP Rack 12.8T12812,8002003232644,0964,0968,192819.2819.21
CoreMinipack-1 OCP Rack 12.8T6412,800200640644,09604,096819.20·

Transceivers

6
CN
 Network Layer
Transceiver / CablePart Name / Model
Total Units#
Units per SW/GPU#
Unit BWGbit/s
Lanes#
BW per LaneGbit/s
Agg. BWTbit/s
Leaf
DownlinkGeneric 200G DR4 QSFP564,09632200450819.2
UplinkGeneric 200G DR4 QSFP564,096#ERR200#ERR500
Spine
DownlinkGeneric 200G DR4 QSFP564,09632200450819.2
UplinkGeneric 200G DR4 QSFP564,096#ERR200#ERR500
Core
DownlinkGeneric 200G DR4 QSFP564,096#ERR200#ERR500
Uplink·······
Super-Core
200G NICs
200G NICsGeneric 200G DR4 QSFP564,096#ERR200#ERR500

Cables

6
CB
 Network Layer
Cable/ FiberType
Total Units#
Units per Transceiver#
Unit BWGbit/s
Lane Count#
SerDes BWGbit/s
Leaf
DownlinkAlready counted above·····
UplinkGeneric 200G Single Mode4,0961200450
Spine
DownlinkAlready counted above·····
UplinkGeneric 200G Single Mode4,0961200450
Core
DownlinkAlready counted above·····
Uplink······
Super-Core
200G NICs
200G NICsGeneric 200G Single Mode4,0961200450

Backend Parts Summary

4
ItemQty/ClusterQty/ServerAttach/XPU
Generic 200G DR4 QSFP5624,57624.001.00
Generic 200G Single Mode12,28812.000.50
NIC - 200G8,1928.000.33
Minipack-1 OCP Rack 12.8T3200.310.01

Frontend network

No converged frontend + storage fabric data for this cluster.

Frontend Parts Summary

0
ItemQty/ClusterQty/ServerAttach/XPU