Live DB — analyst tables
Test
Google 147456 TPUv10t NIC - 1.6T Hyperscaler Ethernet Cluster Configuration

GOOG-TPUv10t-Dragonfly

Google · TPUv10t · NIC - 1.6T

Rack type
Cluster / location
TPUv10t Dragonfly Cluster
Buyer profile
Hyperscaler
Networking type
Ethernet
Number of XPUs
147,456
NIC used
NIC - 1.6T
NICs / XPU
1
Scale-out BW / XPU
1.6T
XPU / server
64

Scale-up network

Assigned blockDefault
TPUv10t
Scale-UpXPU: TPUv10t0 linesshared by 2 SKUs

Scale-up Units are based on the scale-up world size (64 XPUs).

XPU World Size

2
WS
Scale-Up Network LayerPart / Model
Units#
Unit BWGbit/s uni-d
Lane Count#
Lane BWGbit/s uni-d
XPUs per Node·64···
Scale-Up World Size·64···

Switches

2
SW
Scale-Up Network LayerPart / Model
Units#
Unit BWGbit/s uni-d
Lane Count#
Lane BWGbit/s uni-d
per World144x144 Port OCS48···
per Cluster·3,072···

336G SerDes Dragonfly Topology

Dragonfly Worksheet
10

Scale-Up Network Worksheet (per Scale-Up World Size) — from the config workbook.

ConnectorPart / ModelTPUs
per TPU Units#
Units#
Unit BWGbit/s
Lane Count#
SerDes BWGbit/s
BandwidthGbit/s
Attach Ratio# per GPU
Cluster Total#
TPU Rack64
TPU Tray4
PCBPCB14
Flyover2.4T Flyover DAC282,40016336
TPU Cartridge16
Copper cables
Flyover2.4T Flyover DAC2322,400336
DP16x 300G DP487682,400336
PCBPCB116
Total for TPU Rack64
Copper cables
Flyover2.4T Flyover DAC21282,400336
DP300G DP483,0722,400336
DACGeneric 2.4T DAC0.5322,400336
AECGeneric 2.4T AEC1642,400336
Optical2.4T DR8 OSFP31922,400336

Scale-Up Parts Summary

0
ItemQty/ClusterQty/ServerAttach/XPU

Backend network

6 rows
Assigned blockDefault
TPUv10t - 1.6T NIC - ETH - TH7 - GOOG
BackendXPU: TPUv10t6 linesshared by 1 SKU

Backend Units are based on the cluster size (147,456 TPUs).

Switches

5
SW
 Network Layer
Switch and Server SpecAggregate Port UtilizationNetwork Bandwidth Aggregate
SwitchPart Name / Model
Units#
Unit BWGbit/s
Port BWGbit/s
Downlink Ports / SW#
Uplink Ports / SW#
Max Ports#
Downlink Ports#
Uplink Ports#
Total Ports#
Downlink BWTbit/s
Uplink BWTbit/s
OversubRatio
TPUs·147,4561,6001,6000147,456147,456-18,432147,456147,456-29,491.2235,929.6·
TPUs per Node·4····1······
NICs per NodeNIC - 1.6T41,6001,600··1······
L1 switchWhiteBox Tomahawk 7 204.8T2,016204,8001,6006464128129,024129,024258,048206,438.4206,438.41
L2 switchWhiteBox Tomahawk 6 102.4T2,016102,4001,60064064129,0240129,024206,438.40·

Transceivers

5
CN
 Network Layer
Transceiver / CablePart Name / Model
Total Units#
Units per SW/GPU#
Unit BWGbit/s
Lanes#
BW per LaneGbit/s
Agg. BWTbit/s
XPU NodesGeneric 1.6T DR8 (EML)129,024129,0241,6004200206,438.4
·······0
DownlinkGeneric 12.8T XPO 8x1.6T (LPO)16,128812,80064200206,438.4
UplinkGeneric 12.8T XPO 8x1.6T (LPO)16,128812,80064200206,438.4
Leaf
DownlinkGeneric 1.6T DR8 (EML)129,024641,6004400206,438.4
Uplink·······
Spine
Downlink·······
Uplink·······
Core
Downlink·······
Uplink·······
Super-Core

Cables

5
CB
 Network Layer
Cable/ FiberType
Total Units#
Units per Transceiver#
Unit BWGbit/s
Lane Count#
SerDes BWGbit/s
XPU NodesGeneric 1.6T Single Mode129,02411,6004400
·Already counted above·····
DownlinkAlready counted above·····
UplinkGeneric 1.6T Single Mode129,02481,6008200
Leaf
DownlinkAlready counted above·····
Uplink······
Spine
Downlink······
Uplink······
Core
Downlink······
Uplink······
Super-Core

Backend Parts Summary

6
ItemQty/ClusterQty/ServerAttach/XPU
Generic 1.6T DR8 (EML)258,048112.001.75
Generic 1.6T Single Mode258,048112.001.75
Generic 12.8T XPO 8x1.6T (LPO)32,25614.000.22
NIC - 1.6T9,2164.000.06
WhiteBox Tomahawk 7 204.8T2,0160.880.01
WhiteBox Tomahawk 6 102.4T2,0160.880.01

Frontend network

No converged frontend + storage fabric data for this cluster.

Frontend Parts Summary

0
ItemQty/ClusterQty/ServerAttach/XPU

Compute Tray Networking Content

1 rows

Networking components inside the compute tray — accelerators, board-to-board connectors, retimers, and their per-tray bandwidth.

Assigned blockDefault
TPUv10t - Generic
Compute TrayXPU: TPUv10t1 lineshared by 2 SKUs
Tray layerPart / ModelUnits per Tray
Unit BWGb/s
Lanes
Lane BWGb/s
Per switch
XPUs per TrayTPUv9t (Humufish)4····
TPU Tray to Host TrayPCIe 5.0 x16 Cable4512···

Compute Tray Parts Summary

1
ItemQty/ClusterQty/ServerAttach/XPU
PCIe 5.0 x16 Cable147,45664.001.00