Live DB — analyst tables
Test
Oracle 65536 B200 CX-7 Hyperscaler Infiniband Cluster Configuration
OCI-B200-IB-8R-3L
Oracle · B200 · CX-7
Rack type
NVL8
Cluster / location
Default B200
Buyer profile
Hyperscaler
Networking type
Infiniband
Number of XPUs
65,536
NIC used
CX-7
NICs / XPU
1
Scale-out BW / XPU
400G
XPU / server
8
Scale-up network
1 rows
Assigned blockDefault
B200 - NVL8
Scale-UpXPU: B200 NVL81 lineshared by 6 SKUs
Scale-up Units are based on the scale-up world size (8 XPUs).
XPU World Size
2
WS| Scale-Up Network Layer | Part / Model | Units# | Unit BWGbit/s uni-d | Port Count# | Port BWGbit/s uni-d |
|---|---|---|---|---|---|
| XPUs per Node | · | 8 | 7,200 | 18 | 400 |
| Scale-Up World Size | · | 8 | 57,600 | · | · |
Switches
2
SW| Scale-Up Network Layer | Part / Model | Units# | Unit BWGbit/s uni-d | Port Count# | Port BWGbit/s uni-d |
|---|---|---|---|---|---|
| per Switch | Nvidia NVSwitch 5.0 (NVLink 5) | 1 | 28,800 | 72 | 400 |
| Scale-Up Switch Total | Nvidia NVSwitch 5.0 (NVLink 5) | 2 | 57,600 | 72 | · |
Scale-Up Parts Summary
1
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia NVSwitch 5.0 (NVLink 5) | 16,384 | 2.00 | 0.25 |
Backend network
6 rows
Assigned blockDefault
B200 - NVL8 - CX7 - 3L - IB - QM9700 - Generic
BackendXPU: B200 NVL86 linesshared by 3 SKUs
Backend Units are based on the cluster size (65,536 XPUs).
Switches
5
SW Network Layer | Switch and Server Spec | Aggregate Port Utilization | Network Bandwidth Aggregate | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SwitchPart Name / Model | Units# | Unit BWGbit/s | Port BWGbit/s | Downlink Ports / SW# | Uplink Ports / SW# | Max Ports# | Downlink Ports# | Uplink Ports# | Total Ports# | Downlink BWTbit/s | Uplink BWTbit/s | OversubRatio | |
| XPUs | · | 65,536 | 400 | 400 | 0 | 65,536 | 65,536 | 0 | 65,536 | 65,536 | 0 | 26,214.4 | · |
| NICs per Node | ConnectX-7 NIC - 400G | 8 | 400 | 400 | · | · | 8 | · | · | · | · | · | · |
| Leaf | Quantum-2 InfiniBand (QM9700) | 2,048 | 25,600 | 800 | 16 | 16 | 32 | 32,768 | 32,768 | 65,536 | 26,214.4 | 26,214.4 | 1 |
| Spine | Quantum-2 InfiniBand (QM9700) | 2,048 | 25,600 | 800 | 16 | 16 | 32 | 32,768 | 32,768 | 65,536 | 26,214.4 | 26,214.4 | 1 |
| Core | Quantum-2 InfiniBand (QM9700) | 1,024 | 25,600 | 800 | 32 | 0 | 32 | 32,768 | 0 | 32,768 | 26,214.4 | 0 | · |
Transceivers
6
CN Network Layer | Transceiver / CablePart Name / Model | Total Units# | Units per SW/GPU# | Unit BWGbit/s | Lanes# | BW per LaneGbit/s | Agg. BWTbit/s |
|---|---|---|---|---|---|---|---|
| XPU Nodes | Nvidia LinkX 400G DR4 | 65,536 | 65,536 | 400 | 4 | 100 | 26,214.4 |
| Leaf | |||||||
| Downlink | Nvidia LinkX 800G DR8 | 32,768 | 16 | 800 | 8 | 100 | 26,214.4 |
| Uplink | Nvidia LinkX 800G DR8 | 32,768 | 16 | 800 | 8 | 100 | 26,214.4 |
| Spine | |||||||
| Downlink | Nvidia LinkX 800G DR8 | 32,768 | 16 | 800 | 8 | 100 | 26,214.4 |
| Uplink | Nvidia LinkX 800G DR8 | 32,768 | 16 | 800 | 8 | 100 | 26,214.4 |
| Core | |||||||
| Downlink | Nvidia LinkX 800G DR8 | 32,768 | 32 | 800 | 8 | 100 | 26,214.4 |
| Uplink | · | · | · | · | · | · | · |
| Super-Core | |||||||
Cables
6
CB Network Layer | Cable/ FiberType | Total Units# | Units per Transceiver# | Unit BWGbit/s | Lane Count# | SerDes BWGbit/s |
|---|---|---|---|---|---|---|
| XPU Nodes | Nvidia LinkX 400G Single Mode | 65,536 | 1 | 400 | 4 | 100 |
| Leaf | ||||||
| Downlink | Already counted above | · | · | · | · | · |
| Uplink | Nvidia LinkX 800G Single Mode | 32,768 | 1 | 800 | 8 | 100 |
| Spine | ||||||
| Downlink | Already counted above | · | · | · | · | · |
| Uplink | Nvidia LinkX 800G Single Mode | 32,768 | 1 | 800 | 8 | 100 |
| Core | ||||||
| Downlink | Already counted above | · | · | · | · | · |
| Uplink | · | · | · | · | · | · |
| Super-Core | ||||||
Backend Parts Summary
6
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Nvidia LinkX 400G DR4 | 65,536 | 8.00 | 1.00 |
| Nvidia LinkX 400G Single Mode | 65,536 | 8.00 | 1.00 |
| Nvidia LinkX 800G DR8 | 163,840 | 20.00 | 2.50 |
| Nvidia LinkX 800G Single Mode | 65,536 | 8.00 | 1.00 |
| ConnectX-7 NIC - 400G | 65,536 | 8.00 | 1.00 |
| Quantum-2 InfiniBand (QM9700) | 5,120 | 0.63 | 0.08 |
Frontend network
11 rows
Assigned blockDefault
B200 - NVL8 - SN5600 - Generic
FrontendXPU: B200 NVL811 linesshared by 4 SKUs
Converged Frontend + Storage Fabric
11
| Layer | Part / Model | Units | Attach / XPU |
|---|---|---|---|
| · | Spectrum-4 51.2T (SN5600) | 787 | 0.0120 |
| · | Spectrum-3 12.8T (SN4700) | 3 | 0.0000 |
| · | Spectrum-2 6.4T (SN3700) | 117 | 0.0018 |
| · | Spectrum-2 1GbE (SN2201) | 962 | 0.0147 |
| · | Nvidia LinkX 800G SR8 | 38,057 | 0.5807 |
| · | Nvidia LinkX 400G SR4 | 37,859 | 0.5777 |
| · | Nvidia LinkX 100G SR4 QSFP28 | 16,800 | 0.2563 |
| · | Nvidia LinkX 800G Multimode | 52,084 | 0.7947 |
| · | Nvidia LinkX 400G Multimode | 267 | 0.0041 |
| · | Nvidia LinkX 100G Multimode | 7,483 | 0.1142 |
| · | RJ45 Cables | 46,187 | 0.7048 |
Frontend Parts Summary
11
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| Spectrum-4 51.2T (SN5600) | 787 | 0 | 0.0120 |
| Spectrum-3 12.8T (SN4700) | 3 | 0 | 0.0001 |
| Spectrum-2 6.4T (SN3700) | 117 | 0 | 0.0018 |
| Spectrum-2 1GbE (SN2201) | 962 | 0 | 0.0147 |
| Nvidia LinkX 800G SR8 | 38,057 | 5 | 0.5807 |
| Nvidia LinkX 400G SR4 | 37,859 | 5 | 0.5777 |
| Nvidia LinkX 100G SR4 QSFP28 | 16,800 | 2 | 0.2563 |
| Nvidia LinkX 800G Multimode | 52,084 | 6 | 0.7947 |
| Nvidia LinkX 400G Multimode | 267 | 0 | 0.0041 |
| Nvidia LinkX 100G Multimode | 7,483 | 1 | 0.1142 |
| RJ45 Cables | 46,187 | 6 | 0.7048 |
Compute Tray Networking Content
1 rows
Networking components inside the compute tray — accelerators, board-to-board connectors, retimers, and their per-tray bandwidth.
Assigned blockDefault
B200 - NVL8 - Generic
Compute TrayXPU: B200 NVL81 lineshared by 5 SKUs
| Tray layer | Part / Model | Units per Tray | Unit BWGb/s | Lanes | Lane BWGb/s | Per switch |
|---|---|---|---|---|---|---|
| XPUs per Tray | Blackwell 200 | 8 | · | · | · | · |
| B200 Server | NVLink PCIe 5.0 x16 Retimer | 8 | 512 | · | · | · |
Compute Tray Parts Summary
1
| Item | Qty/Cluster | Qty/Server | Attach/XPU |
|---|---|---|---|
| NVLink PCIe 5.0 x16 Retimer | 65,536 | 8.00 | 1.00 |