| # | Item | Unit Cost | Quantity (per Cluster) | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name | 1Q23 | 2Q23 | 3Q23 | 4Q23 | 1Q24 | 2Q24 | 3Q24 | 4Q24 | 1Q25 | 2Q25 | 3Q25 | 4Q25 | 1Q26 | 2Q26 | 3Q26 | 4Q26 | 1Q27 | 2Q27 | 3Q27 | 4Q27 | 1Q28 | 2Q28 | 3Q28 | 4Q28 | 1Q29 | 2Q29 | 3Q29 | 4Q29 | 1Q30 | 2Q30 | 3Q30 | 4Q30 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 501 | Generic 100G Multimode | $150.00 | 4,915 | 3.20 | 0.20 | $737,280.00 | $480.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | Trainium1 | Backend | AWS-Trainium1-Default | $705,600.00 | $559,280.00 | $1,018,480.00 | $1,342,560.00 | $1,129,600.00 | $1,615,760.00 | $2,200,000.00 | $1,900,000.00 | $1,400,000.00 | $70,530.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 502 | Generic 100G SR4 QSFP28 | $49.50 | 12,288 | 8.00 | 0.50 | $608,224.97 | $395.98 | 3 W | 36,864 W | 24 W | Transceiver | Amazon | Coherent | — | Device Level | — | 28G | Ethernet | Fully Retimed | Trainium1 | Backend | AWS-Trainium1-Default | $582,090.31 | $461,382.46 | $840,203.14 | $1,107,555.50 | $931,872.46 | $1,332,934.00 | $1,814,907.42 | $1,567,420.04 | $1,154,941.08 | $58,184.28 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 503 | Generic 100G SR4 QSFP28 | $49.50 | 12,288 | 8.00 | 0.50 | $608,224.97 | $395.98 | 3 W | 36,864 W | 24 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 28G | Ethernet | Fully Retimed | Trainium1 | Backend | AWS-Trainium1-Default | $582,090.31 | $461,382.46 | $840,203.14 | $1,107,555.50 | $931,872.46 | $1,332,934.00 | $1,814,907.42 | $1,567,420.04 | $1,154,941.08 | $58,184.28 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 504 | Generic 100G SR4 QSFP28 | $49.50 | 9,830 | 6.40 | 0.40 | $486,579.98 | $316.78 | 3 W | 29,491 W | 19 W | Transceiver | Amazon | Innolight | — | Device Level | — | 28G | Ethernet | Fully Retimed | Trainium1 | Backend | AWS-Trainium1-Default | $465,672.24 | $369,105.97 | $672,162.51 | $886,044.40 | $745,497.97 | $1,066,347.20 | $1,451,925.93 | $1,253,936.03 | $923,952.87 | $46,547.43 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 505 | Generic 100G SR4 QSFP28 | $49.50 | 14,746 | 9.60 | 0.60 | $729,869.97 | $475.18 | 3 W | 44,237 W | 29 W | Transceiver | Amazon | Others | — | Device Level | — | 28G | Ethernet | Fully Retimed | Trainium1 | Backend | AWS-Trainium1-Default | $698,508.37 | $553,658.96 | $1,008,243.77 | $1,329,066.60 | $1,118,246.95 | $1,599,520.81 | $2,177,888.90 | $1,880,904.05 | $1,385,929.30 | $69,821.14 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 506 | WhiteBox Tomahawk 2 6.4T | $3,072.57 | 365 | 0.24 | 0.01 | $1,120,873.88 | $729.74 | 250 W | 91,200 W | 59 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium1 | Backend | AWS-Trainium1-Default | $1,072,711.33 | $850,263.60 | $1,548,377.32 | $2,041,070.47 | $1,717,311.11 | $2,456,411.65 | $3,344,621.49 | $2,888,536.74 | $2,128,395.50 | $107,225.52 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 507 | WhiteBox Tomahawk 2 6.4T | $3,072.57 | 19 | 0.01 | 0.00 | $58,993.36 | $38.41 | 250 W | 4,800 W | 3 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium1 | Backend | AWS-Trainium1-Default | $56,458.49 | $44,750.72 | $81,493.54 | $107,424.76 | $90,384.80 | $129,284.82 | $176,032.71 | $152,028.25 | $112,020.82 | $5,643.45 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 508 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 29 | 0.02 | 0.00 | $144,000.00 | $93.75 | 450 W | 12,960 W | 8 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium1 | Backend | AWS-Trainium1-Default | $137,812.50 | $109,234.38 | $198,921.87 | $262,218.75 | $220,625.00 | $315,578.13 | $429,687.50 | $371,093.75 | $273,437.50 | $13,775.39 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 509 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 259 | 0.17 | 0.01 | $1,296,000.00 | $843.75 | 450 W | 116,640 W | 76 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium1 | Backend | AWS-Trainium1-Default | $1,240,312.50 | $983,109.38 | $1,790,296.87 | $2,359,968.75 | $1,985,625.00 | $2,840,203.13 | $3,867,187.50 | $3,339,843.75 | $2,460,937.50 | $123,978.52 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 510 | EFAv2 Nitro-v4 100G NIC | $150.00 | 24,576 | 16.00 | 1.00 | $3,686,400.00 | $2,400.00 | 19 W | 466,944 W | 304 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | Trainium1n | Backend | AWS-Trainium1n-Default | $3,528,000.00 | $2,796,400.01 | $5,092,400.00 | $6,712,800.00 | $5,648,000.00 | $8,078,800.01 | $11,000,000.00 | $9,500,000.00 | $7,000,000.01 | $352,650.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 511 | Generic 100G AEC | $70.00 | 22,118 | 14.40 | 0.90 | $1,548,288.00 | $1,008.00 | 8 W | 176,947 W | 115 W | AEC | Amazon | Credo | — | Device Level | — | — | — | — | Trainium1n | Backend | AWS-Trainium1n-Default | $1,481,760.00 | $1,174,488.00 | $2,138,808.00 | $2,819,376.00 | $2,372,160.00 | $3,393,096.00 | $4,620,000.00 | $3,990,000.00 | $2,940,000.00 | $148,113.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 512 | Generic 100G AEC | $70.00 | 2,458 | 1.60 | 0.10 | $172,032.00 | $112.00 | 8 W | 19,661 W | 13 W | AEC | Amazon | Others | — | Device Level | — | — | — | — | Trainium1n | Backend | AWS-Trainium1n-Default | $164,640.00 | $130,498.67 | $237,645.33 | $313,264.00 | $263,573.33 | $377,010.67 | $513,333.33 | $443,333.33 | $326,666.67 | $16,457.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 513 | Generic 100G Multimode | $150.00 | 39,322 | 25.60 | 1.60 | $5,898,240.00 | $3,840.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Corning | — | Device Level | — | — | — | — | Trainium1n | Backend | AWS-Trainium1n-Default | $5,644,800.00 | $4,474,240.01 | $8,147,839.99 | $10,740,480.00 | $9,036,799.99 | $12,926,080.01 | $17,599,999.99 | $15,199,999.99 | $11,200,000.01 | $564,240.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 514 | Generic 100G Multimode | $150.00 | 9,830 | 6.40 | 0.40 | $1,474,560.00 | $960.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | Trainium1n | Backend | AWS-Trainium1n-Default | $1,411,200.00 | $1,118,560.00 | $2,036,960.00 | $2,685,120.00 | $2,259,200.00 | $3,231,520.00 | $4,400,000.00 | $3,800,000.00 | $2,800,000.00 | $141,060.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 515 | Generic 100G SR4 QSFP28 | $49.50 | 24,576 | 16.00 | 1.00 | $1,216,449.95 | $791.96 | 3 W | 73,728 W | 48 W | Transceiver | Amazon | Coherent | — | Device Level | — | 28G | Ethernet | Fully Retimed | Trainium1n | Backend | AWS-Trainium1n-Default | $1,164,180.61 | $922,764.93 | $1,680,406.28 | $2,215,111.00 | $1,863,744.92 | $2,665,868.01 | $3,629,814.83 | $3,134,840.08 | $2,309,882.17 | $116,368.56 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 516 | Generic 100G SR4 QSFP28 | $49.50 | 24,576 | 16.00 | 1.00 | $1,216,449.95 | $791.96 | 3 W | 73,728 W | 48 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 28G | Ethernet | Fully Retimed | Trainium1n | Backend | AWS-Trainium1n-Default | $1,164,180.61 | $922,764.93 | $1,680,406.28 | $2,215,111.00 | $1,863,744.92 | $2,665,868.01 | $3,629,814.83 | $3,134,840.08 | $2,309,882.17 | $116,368.56 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 517 | Generic 100G SR4 QSFP28 | $49.50 | 19,661 | 12.80 | 0.80 | $973,159.96 | $633.57 | 3 W | 58,982 W | 38 W | Transceiver | Amazon | Innolight | — | Device Level | — | 28G | Ethernet | Fully Retimed | Trainium1n | Backend | AWS-Trainium1n-Default | $931,344.49 | $738,211.94 | $1,344,325.02 | $1,772,088.80 | $1,490,995.94 | $2,132,694.41 | $2,903,851.87 | $2,507,872.07 | $1,847,905.73 | $93,094.85 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 518 | Generic 100G SR4 QSFP28 | $49.50 | 29,491 | 19.20 | 1.20 | $1,459,739.93 | $950.35 | 3 W | 88,474 W | 58 W | Transceiver | Amazon | Others | — | Device Level | — | 28G | Ethernet | Fully Retimed | Trainium1n | Backend | AWS-Trainium1n-Default | $1,397,016.73 | $1,107,317.91 | $2,016,487.53 | $2,658,133.20 | $2,236,493.91 | $3,199,041.61 | $4,355,777.80 | $3,761,808.10 | $2,771,858.60 | $139,642.28 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 519 | WhiteBox Tomahawk 2 6.4T | $3,072.57 | 730 | 0.48 | 0.03 | $2,241,747.76 | $1,459.47 | 250 W | 182,400 W | 119 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium1n | Backend | AWS-Trainium1n-Default | $2,145,422.66 | $1,700,527.19 | $3,096,754.63 | $4,082,140.94 | $3,434,622.22 | $4,912,823.30 | $6,689,242.99 | $5,777,073.49 | $4,256,791.00 | $214,451.05 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 520 | WhiteBox Tomahawk 2 6.4T | $3,072.57 | 38 | 0.03 | 0.00 | $117,986.72 | $76.81 | 250 W | 9,600 W | 6 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium1n | Backend | AWS-Trainium1n-Default | $112,916.98 | $89,501.43 | $162,987.09 | $214,849.52 | $180,769.59 | $258,569.65 | $352,065.42 | $304,056.50 | $224,041.63 | $11,286.90 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 521 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 58 | 0.04 | 0.00 | $288,000.00 | $187.50 | 450 W | 25,920 W | 17 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium1n | Backend | AWS-Trainium1n-Default | $275,625.00 | $218,468.75 | $397,843.75 | $524,437.50 | $441,250.00 | $631,156.25 | $859,375.00 | $742,187.50 | $546,875.00 | $27,550.78 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 522 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 518 | 0.34 | 0.02 | $2,592,000.00 | $1,687.50 | 450 W | 233,280 W | 152 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium1n | Backend | AWS-Trainium1n-Default | $2,480,625.00 | $1,966,218.75 | $3,580,593.75 | $4,719,937.50 | $3,971,250.00 | $5,680,406.25 | $7,734,375.00 | $6,679,687.50 | $4,921,875.00 | $247,957.03 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 523 | 112Gb/s SkewClear EXD Cable | $1.00 | 16,773,120 | 18,432.00 | 128.00 | $16,773,120.00 | $18,432.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | Trainium4 | Scale-Up | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $1,824,000.00 | $29,184,000.00 | $58,368,000.00 | $124,160,000.00 | $131,456,000.00 | $136,320,000.00 | $89,600,000.00 | $24,320,000.00 | $9,856,000.00 | — | — | — |
| 524 | Aries PCIe 7.0 x16 Retimer | $54.69 | — | — | — | — | — | 11 W | — | — | Retimer | Amazon | Astera | — | L1 Abstraction | — | — | — | — | Trainium4 | Compute Tray | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 525 | Aries PG6032 16L/32L Gearbox | $20.00 | — | — | — | — | — | 3 W | — | — | Gearbox | Amazon | Astera | — | L1 Abstraction | — | — | — | — | Trainium4 | Compute Tray | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 526 | Astera Labs Scorpio-P 32-Lane PCIe Gen 6.0 | $70.00 | — | — | — | — | — | 80 W | — | — | Scale-Up Switch | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium4 | Compute Tray | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 527 | Astera Labs UALink 57.6T Switch | $7,000.00 | 58,240 | 64.00 | 0.44 | $407,680,000.00 | $448,000.00 | 650 W | 37,856,000 W | 41,600 W | Scale-Up Switch | Amazon | Astera | — | Device Level | — | — | UALink | — | Trainium4 | Scale-Up | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $44,333,333.33 | $709,333,333.33 | $1,418,666,666.67 | $3,017,777,777.78 | $3,195,111,111.11 | $3,313,333,333.33 | $2,177,777,777.78 | $591,111,111.11 | $239,555,555.56 | — | — | — |
| 528 | Generic 800G AEC | $350.00 | 32,760 | 36.00 | 0.25 | $11,466,000.00 | $12,600.00 | 22 W | 733,824 W | 806 W | AEC | Amazon | Astera | — | Device Level | — | — | — | — | Trainium4 | Backend | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $1,246,875.00 | $19,950,000.00 | $39,900,000.00 | $84,875,000.00 | $89,862,500.00 | $93,187,500.00 | $61,250,000.00 | $16,625,000.00 | $6,737,500.00 | — | — | — |
| 529 | Generic 800G AEC | $350.00 | 65,520 | 72.00 | 0.50 | $22,932,000.00 | $25,200.00 | 22 W | 1,467,648 W | 1,613 W | AEC | Amazon | Credo | — | Device Level | — | — | — | — | Trainium4 | Backend | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $2,493,750.00 | $39,900,000.00 | $79,800,000.00 | $169,750,000.00 | $179,725,000.00 | $186,375,000.00 | $122,500,000.00 | $33,250,000.00 | $13,475,000.00 | — | — | — |
| 530 | Generic 800G AEC | $350.00 | 32,760 | 36.00 | 0.25 | $11,466,000.00 | $12,600.00 | 22 W | 733,824 W | 806 W | AEC | Amazon | Marvell | — | Device Level | — | — | — | — | Trainium4 | Backend | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $1,246,875.00 | $19,950,000.00 | $39,900,000.00 | $84,875,000.00 | $89,862,500.00 | $93,187,500.00 | $61,250,000.00 | $16,625,000.00 | $6,737,500.00 | — | — | — |
| 531 | Generic 800G DR8 | $500.00 | 52,416 | 57.60 | 0.40 | $26,208,000.00 | $28,800.00 | 16 W | 838,656 W | 922 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium4 | Backend | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $2,850,000.00 | $45,600,000.00 | $91,200,000.00 | $194,000,000.00 | $205,400,000.00 | $213,000,000.00 | $140,000,000.00 | $38,000,000.00 | $15,400,000.00 | — | — | — |
| 532 | Generic 800G DR8 | $500.00 | 209,664 | 230.40 | 1.60 | $104,832,000.00 | $115,200.00 | 16 W | 3,354,624 W | 3,686 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium4 | Backend | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $11,400,000.00 | $182,400,000.00 | $364,800,000.00 | $776,000,000.00 | $821,600,000.00 | $852,000,000.00 | $560,000,000.00 | $152,000,000.00 | $61,600,000.00 | — | — | — |
| 533 | Generic 800G DR8 | $500.00 | 262,080 | 288.00 | 2.00 | $131,040,000.00 | $144,000.00 | 16 W | 4,193,280 W | 4,608 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium4 | Backend | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $14,250,000.00 | $228,000,000.00 | $456,000,000.00 | $970,000,000.00 | $1,027,000,000.00 | $1,065,000,000.00 | $700,000,000.00 | $190,000,000.00 | $77,000,000.00 | — | — | — |
| 534 | Generic 800G Single Mode | $180.00 | 262,080 | 288.00 | 2.00 | $47,174,400.00 | $51,840.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | Trainium4 | Backend | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $5,130,000.00 | $82,080,000.00 | $164,160,000.00 | $349,200,000.00 | $369,720,000.00 | $383,400,000.00 | $252,000,000.00 | $68,400,000.00 | $27,720,000.00 | — | — | — |
| 535 | Nitro-v7 800G NIC | $900.00 | 131,040 | 4.00 | 1.00 | $117,936,000.00 | $3,600.00 | 75 W | 9,828,000 W | 300 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | Trainium4 | Backend | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $12,825,000.00 | $205,200,000.00 | $410,400,000.00 | $873,000,000.00 | $924,300,000.00 | $958,500,000.00 | $630,000,000.00 | $171,000,000.00 | $69,300,000.00 | — | — | — |
| 536 | Paladin HD2 224Gb/s 144 DP (Female) | $72.00 | 247,520 | 272.00 | 1.89 | $17,821,440.00 | $19,584.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | Trainium4 | Scale-Up | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $1,938,000.00 | $31,008,000.00 | $62,016,000.00 | $131,920,000.00 | $139,672,000.00 | $144,840,000.00 | $95,200,000.00 | $25,840,000.00 | $10,472,000.00 | — | — | — |
| 537 | Paladin HD2 224Gb/s 144 DP (Male) | $144.00 | 247,520 | 272.00 | 1.89 | $35,642,880.00 | $39,168.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | Trainium4 | Scale-Up | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $3,876,000.00 | $62,016,000.00 | $124,032,000.00 | $263,840,000.00 | $279,344,000.00 | $289,680,000.00 | $190,400,000.00 | $51,680,000.00 | $20,944,000.00 | — | — | — |
| 538 | Teton4 Backplane Chassis | $8,500.80 | 1,820 | 2.00 | 0.01 | $15,471,456.00 | $17,001.60 | 0 W | 0 W | 0 W | Backplane | Amazon | Others | — | Device Level | — | — | — | — | Trainium4 | Scale-Up | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $1,682,450.00 | $26,919,200.00 | $53,838,400.00 | $114,524,666.67 | $121,254,466.67 | $125,741,000.00 | $82,646,666.67 | $22,432,666.67 | $9,091,133.33 | — | — | — |
| 539 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 512 | 0.56 | 0.00 | $9,981,562.50 | $10,968.75 | 1,200 W | 614,250 W | 675 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium4 | Backend | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $1,085,449.22 | $17,367,187.50 | $34,734,375.00 | $73,886,718.75 | $78,228,515.63 | $81,123,046.88 | $53,320,312.50 | $14,472,656.25 | $5,865,234.38 | — | — | — |
| 540 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 9,726 | 10.69 | 0.07 | $189,649,687.50 | $208,406.25 | 1,200 W | 11,670,750 W | 12,825 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium4 | Backend | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $20,623,535.16 | $329,976,562.50 | $659,953,125.00 | $1,403,847,656.25 | $1,486,341,796.88 | $1,541,337,890.63 | $1,013,085,937.50 | $274,980,468.75 | $111,439,453.13 | — | — | — |
| 541 | 112Gb/s SkewClear EXD Cable | $1.00 | 37,739,520 | 41,472.00 | 288.00 | $37,739,520.00 | $41,472.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | Trainium4 | Scale-Up | AWS-Trn4 EFA-WB NL144 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 542 | Aries PCIe 7.0 x16 Retimer | $54.69 | — | — | — | — | — | 11 W | — | — | Retimer | Amazon | Unassigned | — | L1 Abstraction | — | — | — | — | Trainium4 | Compute Tray | AWS-Trn4 EFA-WB NL144 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 543 | Aries PG6032 16L/32L Gearbox | $20.00 | — | — | — | — | — | 3 W | — | — | Gearbox | Amazon | Astera | — | L1 Abstraction | — | — | — | — | Trainium4 | Compute Tray | AWS-Trn4 EFA-WB NL144 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 544 | Astera Labs Scorpio-P 32-Lane PCIe Gen 6.0 | $70.00 | — | — | — | — | — | 80 W | — | — | Scale-Up Switch | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium4 | Compute Tray | AWS-Trn4 EFA-WB NL144 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 545 | Astera Labs UALink 57.6T Switch | $7,000.00 | 65,520 | 72.00 | 0.50 | $458,640,000.00 | $504,000.00 | 650 W | 42,588,000 W | 46,800 W | Scale-Up Switch | Amazon | Astera | — | Device Level | — | — | UALink | — | Trainium4 | Scale-Up | AWS-Trn4 EFA-WB NL144 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 546 | Generic 800G AEC | $350.00 | 32,760 | 36.00 | 0.25 | $11,466,000.00 | $12,600.00 | 22 W | 733,824 W | 806 W | AEC | Amazon | Astera | — | Device Level | — | — | — | — | Trainium4 | Backend | AWS-Trn4 EFA-WB NL144 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 547 | Generic 800G AEC | $350.00 | 65,520 | 72.00 | 0.50 | $22,932,000.00 | $25,200.00 | 22 W | 1,467,648 W | 1,613 W | AEC | Amazon | Credo | — | Device Level | — | — | — | — | Trainium4 | Backend | AWS-Trn4 EFA-WB NL144 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 548 | Generic 800G AEC | $350.00 | 32,760 | 36.00 | 0.25 | $11,466,000.00 | $12,600.00 | 22 W | 733,824 W | 806 W | AEC | Amazon | Marvell | — | Device Level | — | — | — | — | Trainium4 | Backend | AWS-Trn4 EFA-WB NL144 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 549 | Generic 800G DR8 | $500.00 | 52,416 | 57.60 | 0.40 | $26,208,000.00 | $28,800.00 | 16 W | 838,656 W | 922 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium4 | Backend | AWS-Trn4 EFA-WB NL144 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 550 | Generic 800G DR8 | $500.00 | 209,664 | 230.40 | 1.60 | $104,832,000.00 | $115,200.00 | 16 W | 3,354,624 W | 3,686 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium4 | Backend | AWS-Trn4 EFA-WB NL144 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 551 | Generic 800G DR8 | $500.00 | 262,080 | 288.00 | 2.00 | $131,040,000.00 | $144,000.00 | 16 W | 4,193,280 W | 4,608 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium4 | Backend | AWS-Trn4 EFA-WB NL144 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 552 | Generic 800G Single Mode | $180.00 | 262,080 | 288.00 | 2.00 | $47,174,400.00 | $51,840.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | Trainium4 | Backend | AWS-Trn4 EFA-WB NL144 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 553 | Generic PCIe Gen6 x16 (128Gb/s uni-di) 2-meter AEC | $420.00 | 131,040 | 144.00 | 1.00 | $55,036,800.00 | $60,480.00 | 4 W | 524,160 W | 576 W | AEC | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium4 | Scale-Up | AWS-Trn4 EFA-WB NL144 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 554 | Nitro-v7 800G NIC | $900.00 | 131,040 | 4.00 | 1.00 | $117,936,000.00 | $3,600.00 | 75 W | 9,828,000 W | 300 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | Trainium4 | Backend | AWS-Trn4 EFA-WB NL144 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 555 | Paladin HD2 224Gb/s 144 DP (Female) | $72.00 | 524,160 | 576.00 | 4.00 | $37,739,520.00 | $41,472.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | Trainium4 | Scale-Up | AWS-Trn4 EFA-WB NL144 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 556 | Paladin HD2 224Gb/s 144 DP (Male) | $144.00 | 524,160 | 576.00 | 4.00 | $75,479,040.00 | $82,944.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | Trainium4 | Scale-Up | AWS-Trn4 EFA-WB NL144 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 557 | Teton4 Backplane Chassis | $8,500.80 | 1,820 | 2.00 | 0.01 | $15,471,456.00 | $17,001.60 | 0 W | 0 W | 0 W | Backplane | Amazon | Others | — | Device Level | — | — | — | — | Trainium4 | Scale-Up | AWS-Trn4 EFA-WB NL144 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 558 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 512 | 0.56 | 0.00 | $9,981,562.50 | $10,968.75 | 1,200 W | 614,250 W | 675 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium4 | Backend | AWS-Trn4 EFA-WB NL144 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 559 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 9,726 | 10.69 | 0.07 | $189,649,687.50 | $208,406.25 | 1,200 W | 11,670,750 W | 12,825 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium4 | Backend | AWS-Trn4 EFA-WB NL144 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 560 | Generic 1.6T DR8 (SiPho) | $810.00 | 78,643 | 43.20 | 0.60 | $63,700,992.00 | $34,992.00 | 22 W | 1,730,150 W | 950 W | Transceiver | Amazon | Coherent | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Backend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $6,998,400.00 | $41,990,400.00 | $58,320,000.00 | $72,900,000.00 | $72,900,000.00 | $19,516,904.64 | $8,310,600.00 | $3,936,600.00 | — | — | — | — | — | — | — | — | — |
| 561 | Generic 1.6T DR8 (SiPho) | $810.00 | 117,965 | 64.80 | 0.90 | $95,551,488.00 | $52,488.00 | 22 W | 2,595,226 W | 1,426 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Backend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $10,497,600.00 | $62,985,600.00 | $87,480,000.00 | $109,350,000.00 | $109,350,000.00 | $29,275,356.96 | $12,465,900.00 | $5,904,900.00 | — | — | — | — | — | — | — | — | — |
| 562 | Generic 1.6T DR8 (SiPho) | $810.00 | 196,608 | 108.00 | 1.50 | $159,252,480.00 | $87,480.00 | 22 W | 4,325,376 W | 2,376 W | Transceiver | Amazon | Innolight | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Backend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $17,496,000.00 | $104,976,000.00 | $145,800,000.00 | $182,250,000.00 | $182,250,000.00 | $48,792,261.60 | $20,776,500.00 | $9,841,500.00 | — | — | — | — | — | — | — | — | — |
| 563 | Generic 1.6T DR8 (SiPho) | $810.00 | 15,223 | 8.36 | 0.12 | $12,330,481.37 | $6,773.34 | 22 W | 334,902 W | 184 W | Transceiver | Amazon | Coherent | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $1,354,667.14 | $8,128,002.86 | $11,288,892.86 | $14,111,116.07 | $14,111,116.07 | $3,777,850.57 | $1,608,667.23 | $762,000.27 | — | — | — | — | — | — | — | — | — |
| 564 | Generic 1.6T DR8 (SiPho) | $810.00 | 22,834 | 12.54 | 0.17 | $18,495,722.06 | $10,160.00 | 22 W | 502,353 W | 276 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $2,032,000.71 | $12,192,004.29 | $16,933,339.29 | $21,166,674.11 | $21,166,674.11 | $5,666,775.86 | $2,413,000.85 | $1,143,000.40 | — | — | — | — | — | — | — | — | — |
| 565 | Generic 1.6T DR8 (SiPho) | $810.00 | 38,057 | 20.91 | 0.29 | $30,826,203.43 | $16,933.34 | 22 W | 837,255 W | 460 W | Transceiver | Amazon | Innolight | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $3,386,667.86 | $20,320,007.14 | $28,222,232.14 | $35,277,790.18 | $35,277,790.18 | $9,444,626.43 | $4,021,668.08 | $1,905,000.67 | — | — | — | — | — | — | — | — | — |
| 566 | Generic 200G Multimode | $150.00 | 14,967 | 8.22 | 0.11 | $2,244,998.10 | $1,233.21 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $246,642.86 | $1,479,857.14 | $2,055,357.14 | $2,569,196.43 | $2,569,196.43 | $687,829.38 | $292,888.39 | $138,736.61 | — | — | — | — | — | — | — | — | — |
| 567 | Generic 200G SR4 | $130.00 | 3,360 | 1.85 | 0.03 | $436,802.64 | $239.94 | 5 W | 16,800 W | 9 W | Transceiver | Amazon | AAOI | — | Device Level | — | 56G | Ethernet | Fully Retimed | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $47,988.57 | $287,931.43 | $399,904.76 | $499,880.95 | $499,880.95 | $133,828.93 | $56,986.43 | $26,993.57 | — | — | — | — | — | — | — | — | — |
| 568 | Generic 200G SR4 | $130.00 | 3,360 | 1.85 | 0.03 | $436,802.64 | $239.94 | 5 W | 16,800 W | 9 W | Transceiver | Amazon | Coherent | — | Device Level | — | 56G | Ethernet | Fully Retimed | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $47,988.57 | $287,931.43 | $399,904.76 | $499,880.95 | $499,880.95 | $133,828.93 | $56,986.43 | $26,993.57 | — | — | — | — | — | — | — | — | — |
| 569 | Generic 200G SR4 | $130.00 | 18,480 | 10.15 | 0.14 | $2,402,414.53 | $1,319.69 | 5 W | 92,401 W | 51 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 56G | Ethernet | Fully Retimed | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $263,937.14 | $1,583,622.86 | $2,199,476.19 | $2,749,345.24 | $2,749,345.24 | $736,059.11 | $313,425.36 | $148,464.64 | — | — | — | — | — | — | — | — | — |
| 570 | Generic 200G SR4 | $130.00 | 8,400 | 4.61 | 0.06 | $1,092,006.60 | $599.86 | 5 W | 42,000 W | 23 W | Transceiver | Amazon | Innolight | — | Device Level | — | 56G | Ethernet | Fully Retimed | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $119,971.43 | $719,828.57 | $999,761.90 | $1,249,702.38 | $1,249,702.38 | $334,572.32 | $142,466.07 | $67,483.93 | — | — | — | — | — | — | — | — | — |
| 571 | Generic 400G Multimode | $150.00 | 533 | 0.29 | 0.00 | $79,969.52 | $43.93 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $8,785.71 | $52,714.29 | $73,214.29 | $91,517.86 | $91,517.86 | $24,501.31 | $10,433.04 | $4,941.96 | — | — | — | — | — | — | — | — | — |
| 572 | Generic 800G DR4 | $650.00 | 26,214 | 14.40 | 0.20 | $17,039,360.00 | $9,360.00 | 17 W | 445,645 W | 245 W | Transceiver | Amazon | AAOI | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Backend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $1,872,000.00 | $11,232,000.00 | $15,600,000.00 | $19,500,000.00 | $19,500,000.00 | $5,220,571.20 | $2,223,000.00 | $1,053,000.00 | — | — | — | — | — | — | — | — | — |
| 573 | Generic 800G DR4 | $650.00 | 104,858 | 57.60 | 0.80 | $68,157,440.00 | $37,440.00 | 17 W | 1,782,579 W | 979 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Backend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $7,488,000.00 | $44,928,000.00 | $62,400,000.00 | $78,000,000.00 | $78,000,000.00 | $20,882,284.80 | $8,892,000.00 | $4,212,000.00 | — | — | — | — | — | — | — | — | — |
| 574 | Generic 800G DR4 | $650.00 | 131,072 | 72.00 | 1.00 | $85,196,800.00 | $46,800.00 | 17 W | 2,228,224 W | 1,224 W | Transceiver | Amazon | Innolight | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Backend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $9,360,000.00 | $56,160,000.00 | $78,000,000.00 | $97,500,000.00 | $97,500,000.00 | $26,102,856.00 | $11,115,000.00 | $5,265,000.00 | — | — | — | — | — | — | — | — | — |
| 575 | Generic 800G DR4 | $650.00 | 7,572 | 4.16 | 0.06 | $4,921,636.57 | $2,703.54 | 17 W | 128,720 W | 71 W | Transceiver | Amazon | AAOI | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $540,707.14 | $3,244,242.86 | $4,505,892.86 | $5,632,366.07 | $5,632,366.07 | $1,507,906.06 | $642,089.73 | $304,147.77 | — | — | — | — | — | — | — | — | — |
| 576 | Generic 800G DR4 | $650.00 | 30,287 | 16.64 | 0.23 | $19,686,546.29 | $10,814.14 | 17 W | 514,879 W | 283 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $2,162,828.57 | $12,976,971.43 | $18,023,571.43 | $22,529,464.29 | $22,529,464.29 | $6,031,624.23 | $2,568,358.93 | $1,216,591.07 | — | — | — | — | — | — | — | — | — |
| 577 | Generic 800G DR4 | $650.00 | 37,859 | 20.80 | 0.29 | $24,608,182.86 | $13,517.68 | 17 W | 643,599 W | 354 W | Transceiver | Amazon | Innolight | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $2,703,535.71 | $16,221,214.29 | $22,529,464.29 | $28,161,830.36 | $28,161,830.36 | $7,539,530.28 | $3,210,448.66 | $1,520,738.84 | — | — | — | — | — | — | — | — | — |
| 578 | Generic 800G DR4 Single Mode | $130.00 | 524,288 | 288.00 | 4.00 | $68,157,440.00 | $37,440.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | VR200 | Backend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $7,488,000.00 | $44,928,000.00 | $62,400,000.00 | $78,000,000.00 | $78,000,000.00 | $20,882,284.80 | $8,892,000.00 | $4,212,000.00 | — | — | — | — | — | — | — | — | — |
| 579 | Generic 800G Multimode | $210.00 | 104,168 | 57.22 | 0.79 | $21,875,370.67 | $12,016.50 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $2,403,300.00 | $14,419,800.00 | $20,027,500.00 | $25,034,375.00 | $25,034,375.00 | $6,702,242.93 | $2,853,918.75 | $1,351,856.25 | — | — | — | — | — | — | — | — | — |
| 580 | Nitro-v7 800G NIC | $900.00 | 262,144 | 8.00 | 2.00 | $235,929,600.00 | $7,200.00 | 75 W | 19,660,800 W | 600 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | VR200 | Backend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $25,920,000.00 | $155,520,000.00 | $216,000,000.00 | $270,000,000.00 | $270,000,000.00 | $72,284,832.00 | $30,780,000.00 | $14,580,000.00 | — | — | — | — | — | — | — | — | — |
| 581 | NV 224Gb/s SkewClear EXD Gen 2 Bidi Cable | $4.00 | 9,437,184 | 5,184.00 | 72.00 | $37,748,736.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Scale-Up | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $4,147,200.00 | $24,883,200.00 | $34,560,000.00 | $43,200,000.00 | $43,200,000.00 | $11,565,573.12 | $4,924,800.00 | $2,332,800.00 | — | — | — | — | — | — | — | — | — |
| 582 | Nvidia NVSwitch 6.0 (NVLink 6) | $4,000.00 | 65,536 | 36.00 | 0.50 | $262,144,000.00 | $144,000.00 | 650 W | 42,598,400 W | 23,400 W | Scale-Up Switch | Amazon | Nvidia | — | Device Level | — | — | NVLink | — | VR200 | Scale-Up | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $28,800,000.00 | $172,800,000.00 | $240,000,000.00 | $300,000,000.00 | $300,000,000.00 | $80,316,480.00 | $34,200,000.00 | $16,200,000.00 | — | — | — | — | — | — | — | — | — |
| 583 | NVL Spine Chassis (NvLink 6) | $225.00 | 3,641 | 2.00 | 0.03 | $819,200.00 | $450.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Unassigned | Others | Device Level | — | — | NVLink | — | VR200 | Scale-Up | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $90,000.00 | $540,000.00 | $750,000.00 | $937,500.00 | $937,500.00 | $250,989.00 | $106,875.00 | $50,625.00 | — | — | — | — | — | — | — | — | — |
| 584 | NV Paladin Board to Board 32 Pin 4p8c (Female) | $32.00 | 131,072 | 72.00 | 1.00 | $4,194,304.00 | $2,304.00 | 0 W | 0 W | 0 W | Midplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Compute Tray | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $460,800.00 | $2,764,800.00 | $3,840,000.00 | $4,800,000.00 | $4,800,000.00 | $1,285,063.68 | $547,200.00 | $259,200.00 | — | — | — | — | — | — | — | — | — |
| 585 | NV Paladin Board to Board 32 Pin 4p8c (Male) | $64.00 | 131,072 | 72.00 | 1.00 | $8,388,608.00 | $4,608.00 | 0 W | 0 W | 0 W | Midplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Compute Tray | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $921,600.00 | $5,529,600.00 | $7,680,000.00 | $9,600,000.00 | $9,600,000.00 | $2,570,127.36 | $1,094,400.00 | $518,400.00 | — | — | — | — | — | — | — | — | — |
| 586 | NV Paladin Board to Board 64 Pin 4p16c (Female) | $64.00 | 524,288 | 288.00 | 4.00 | $33,554,432.00 | $18,432.00 | 0 W | 0 W | 0 W | Midplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Compute Tray | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $3,686,400.00 | $22,118,400.00 | $30,720,000.00 | $38,400,000.00 | $38,400,000.00 | $10,280,509.44 | $4,377,600.00 | $2,073,600.00 | — | — | — | — | — | — | — | — | — |
| 587 | NV Paladin Board to Board 64 Pin 4p16c (Male) | $128.00 | 524,288 | 288.00 | 4.00 | $67,108,864.00 | $36,864.00 | 0 W | 0 W | 0 W | Midplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Compute Tray | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $7,372,800.00 | $44,236,800.00 | $61,440,000.00 | $76,800,000.00 | $76,800,000.00 | $20,561,018.88 | $8,755,200.00 | $4,147,200.00 | — | — | — | — | — | — | — | — | — |
| 588 | NV Paladin HD2 224Gb/s 144 Bidi (Female) | $288.00 | 65,536 | 36.00 | 0.50 | $18,874,368.00 | $10,368.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Scale-Up | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $2,073,600.00 | $12,441,600.00 | $17,280,000.00 | $21,600,000.00 | $21,600,000.00 | $5,782,786.56 | $2,462,400.00 | $1,166,400.00 | — | — | — | — | — | — | — | — | — |
| 589 | NV Paladin HD2 224Gb/s 144 Bidi (Male) | $576.00 | 65,536 | 36.00 | 0.50 | $37,748,736.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Scale-Up | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $4,147,200.00 | $24,883,200.00 | $34,560,000.00 | $43,200,000.00 | $43,200,000.00 | $11,565,573.12 | $4,924,800.00 | $2,332,800.00 | — | — | — | — | — | — | — | — | — |
| 590 | NV Paladin HD2 224Gb/s 72 Bidi (Female) | $144.00 | 9,437,184 | 5,184.00 | 72.00 | $1,358,954,496.00 | $746,496.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Scale-Up | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $149,299,200.00 | $895,795,200.00 | $1,244,160,000.00 | $1,555,200,000.00 | $1,555,200,000.00 | $416,360,632.32 | $177,292,800.00 | $83,980,800.00 | — | — | — | — | — | — | — | — | — |
| 591 | NV Paladin HD2 224Gb/s 72 Bidi (Male) | $288.00 | 131,072 | 72.00 | 1.00 | $37,748,736.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Scale-Up | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $4,147,200.00 | $24,883,200.00 | $34,560,000.00 | $43,200,000.00 | $43,200,000.00 | $11,565,573.12 | $4,924,800.00 | $2,332,800.00 | — | — | — | — | — | — | — | — | — |
| 592 | RJ45 Cables | $1.00 | 92,375 | 50.74 | 0.70 | $92,374.55 | $50.74 | 0 W | 0 W | 0 W | Cable | Amazon | Amphenol | — | Device Level | — | — | — | — | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $10,148.57 | $60,891.43 | $84,571.43 | $105,714.29 | $105,714.29 | $28,302.00 | $12,051.43 | $5,708.57 | — | — | — | — | — | — | — | — | — |
| 593 | WhiteBox Tomahawk 2 6.4T | $3,072.57 | 1,828 | 1.00 | 0.01 | $5,617,416.61 | $3,085.74 | 250 W | 457,062 W | 251 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $617,147.82 | $3,702,886.92 | $5,142,898.51 | $6,428,623.13 | $6,428,623.13 | $1,721,081.27 | $732,863.04 | $347,145.65 | — | — | — | — | — | — | — | — | — |
| 594 | WhiteBox Tomahawk 2 6.4T | $3,072.57 | 96 | 0.05 | 0.00 | $295,653.51 | $162.41 | 250 W | 24,056 W | 13 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $32,481.46 | $194,888.79 | $270,678.87 | $338,348.59 | $338,348.59 | $90,583.22 | $38,571.74 | $18,270.82 | — | — | — | — | — | — | — | — | — |
| 595 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 23 | 0.01 | 0.00 | $117,028.57 | $64.29 | 450 W | 10,533 W | 6 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $12,857.14 | $77,142.86 | $107,142.86 | $133,928.57 | $133,928.57 | $35,855.57 | $15,267.86 | $7,232.14 | — | — | — | — | — | — | — | — | — |
| 596 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 211 | 0.12 | 0.00 | $1,053,257.14 | $578.57 | 450 W | 94,793 W | 52 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $115,714.29 | $694,285.71 | $964,285.71 | $1,205,357.14 | $1,205,357.14 | $322,700.14 | $137,410.71 | $65,089.29 | — | — | — | — | — | — | — | — | — |
| 597 | WhiteBox Tomahawk 4 25.6T | $13,500.00 | 6 | 0.00 | 0.00 | $83,382.85 | $45.80 | 850 W | 5,250 W | 3 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $9,160.71 | $54,964.28 | $76,339.28 | $95,424.10 | $95,424.10 | $25,547.09 | $10,878.35 | $5,152.90 | — | — | — | — | — | — | — | — | — |
| 598 | WhiteBox Tomahawk 4 25.6T | $13,500.00 | 0 | 0.00 | 0.00 | $4,388.57 | $2.41 | 850 W | 276 W | 0 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $482.14 | $2,892.86 | $4,017.86 | $5,022.32 | $5,022.32 | $1,344.58 | $572.54 | $271.21 | — | — | — | — | — | — | — | — | — |
| 599 | WhiteBox Tomahawk 6 102.4T | $40,000.00 | 2,765 | 1.52 | 0.02 | $110,592,000.00 | $60,750.00 | 1,697 W | 4,692,021 W | 2,577 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | VR200 | Backend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $12,150,000.00 | $72,900,000.00 | $101,250,000.00 | $126,562,500.00 | $126,562,500.00 | $33,883,515.00 | $14,428,125.00 | $6,834,375.00 | — | — | — | — | — | — | — | — | — |
| 600 | WhiteBox Tomahawk 6 102.4T | $40,000.00 | 3,379 | 1.86 | 0.03 | $135,168,000.00 | $74,250.00 | 1,697 W | 5,734,693 W | 3,150 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | VR200 | Backend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | $14,850,000.00 | $89,100,000.00 | $123,750,000.00 | $154,687,500.00 | $154,687,500.00 | $41,413,185.00 | $17,634,375.00 | $8,353,125.00 | — | — | — | — | — | — | — | — | — |