Live DB — analyst tables
Test
XPU Shipments
NetworkingDB
Every Cluster BoM Summary row joined to its ClusterDB quarterly series — XPU counts, equipment units and equipment spend per quarter.
Live networking_db (read-only)6,421 rows · 4,391 with matched XPU seriesbuilt 7/23/2026, 11:16:18 AM
| # | Item | Unit Cost | Quantity (per Cluster) | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name | 1Q23 | 2Q23 | 3Q23 | 4Q23 | 1Q24 | 2Q24 | 3Q24 | 4Q24 | 1Q25 | 2Q25 | 3Q25 | 4Q25 | 1Q26 | 2Q26 | 3Q26 | 4Q26 | 1Q27 | 2Q27 | 3Q27 | 4Q27 | 1Q28 | 2Q28 | 3Q28 | 4Q28 | 1Q29 | 2Q29 | 3Q29 | 4Q29 | 1Q30 | 2Q30 | 3Q30 | 4Q30 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 401 | Generic 400G AEC | $250.00 | 33,792 | 16.50 | 0.26 | $8,448,000.00 | $4,125.00 | 12 W | 405,504 W | 198 W | AEC | Amazon | Astera | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | $32,226.56 | $296,484.38 | $1,385,742.19 | $2,152,734.38 | $2,255,859.38 | $2,255,859.38 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 402 | Generic 400G AEC | $250.00 | 74,342 | 36.30 | 0.57 | $18,585,600.00 | $9,075.00 | 12 W | 892,109 W | 436 W | AEC | Amazon | Credo | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | $70,898.44 | $652,265.63 | $3,048,632.81 | $4,736,015.63 | $4,962,890.63 | $4,962,890.63 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 403 | Generic 400G AEC | $250.00 | 27,034 | 13.20 | 0.21 | $6,758,400.00 | $3,300.00 | 12 W | 324,403 W | 158 W | AEC | Amazon | Marvell | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | $25,781.25 | $237,187.50 | $1,108,593.75 | $1,722,187.50 | $1,804,687.50 | $1,804,687.50 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 404 | Generic 400G DR4 | $260.00 | 13,517 | 6.60 | 0.10 | $3,514,368.00 | $1,716.00 | 10 W | 135,168 W | 66 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | $13,406.25 | $123,337.50 | $576,468.75 | $895,537.50 | $938,437.50 | $938,437.50 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 405 | Generic 400G DR4 | $260.00 | 20,275 | 9.90 | 0.15 | $5,271,552.00 | $2,574.00 | 10 W | 202,752 W | 99 W | Transceiver | Amazon | Coherent | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | $20,109.38 | $185,006.25 | $864,703.13 | $1,343,306.25 | $1,407,656.25 | $1,407,656.25 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 406 | Generic 400G DR4 | $260.00 | 67,584 | 33.00 | 0.52 | $17,571,840.00 | $8,580.00 | 10 W | 675,840 W | 330 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | $67,031.25 | $616,687.50 | $2,882,343.75 | $4,477,687.50 | $4,692,187.50 | $4,692,187.50 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 407 | Generic 400G DR4 | $260.00 | 33,792 | 16.50 | 0.26 | $8,785,920.00 | $4,290.00 | 10 W | 337,920 W | 165 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | $33,515.63 | $308,343.75 | $1,441,171.88 | $2,238,843.75 | $2,346,093.75 | $2,346,093.75 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 408 | Generic 400G Single Mode | $130.00 | 270,336 | 132.00 | 2.06 | $35,143,680.00 | $17,160.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | $134,062.50 | $1,233,375.00 | $5,764,687.50 | $8,955,375.00 | $9,384,375.00 | $9,384,375.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 409 | Generic 800G DR8 | $500.00 | 20,275 | 9.90 | 0.15 | $10,137,600.00 | $4,950.00 | 16 W | 324,403 W | 158 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | $38,671.88 | $355,781.25 | $1,662,890.63 | $2,583,281.25 | $2,707,031.25 | $2,707,031.25 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 410 | Generic 800G DR8 | $500.00 | 81,101 | 39.60 | 0.62 | $40,550,400.00 | $19,800.00 | 16 W | 1,297,613 W | 634 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | $154,687.50 | $1,423,125.00 | $6,651,562.50 | $10,333,125.00 | $10,828,125.00 | $10,828,125.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 411 | Generic 800G DR8 | $500.00 | 101,376 | 49.50 | 0.77 | $50,688,000.00 | $24,750.00 | 16 W | 1,622,016 W | 792 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | $193,359.38 | $1,778,906.25 | $8,314,453.13 | $12,916,406.25 | $13,535,156.25 | $13,535,156.25 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 412 | Strada Whisper 112Gb/s 64 DP Absolute Connector (Female) | $14.08 | 393,216 | 192.00 | 3.00 | $5,536,481.28 | $2,703.36 | 0 W | 0 W | 0 W | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | $21,120.00 | $194,304.00 | $908,160.00 | $1,410,816.00 | $1,478,400.00 | $1,478,400.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 413 | Strada Whisper 112Gb/s 64 DP Absolute Connector (Male) | $42.24 | 393,216 | 192.00 | 3.00 | $16,609,443.84 | $8,110.08 | 0 W | 0 W | 0 W | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | $63,360.00 | $582,912.00 | $2,724,480.00 | $4,232,448.00 | $4,435,200.00 | $4,435,200.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 414 | Teton3 Backplane Chassis | $7,728.00 | 8,192 | 4.00 | 0.06 | $63,307,776.00 | $30,912.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Others | — | Device Level | — | — | — | — | Trainium3 | Scale-Up | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | $241,500.00 | $2,221,800.00 | $10,384,500.00 | $16,132,200.00 | $16,905,000.00 | $16,905,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 415 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 8,026 | 3.92 | 0.06 | $40,128,000.00 | $19,593.75 | 450 W | 3,611,520 W | 1,763 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | $153,076.17 | $1,408,300.78 | $6,582,275.39 | $10,225,488.28 | $10,715,332.03 | $10,715,332.03 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 416 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 422 | 0.21 | 0.00 | $2,112,000.00 | $1,031.25 | 450 W | 190,080 W | 93 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | $8,056.64 | $74,121.09 | $346,435.55 | $538,183.59 | $563,964.84 | $563,964.84 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 417 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 1,426 | 0.70 | 0.01 | $27,799,200.00 | $13,573.83 | 1,200 W | 1,710,720 W | 835 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | $106,045.53 | $975,618.90 | $4,559,957.89 | $7,083,841.55 | $7,423,187.26 | $7,423,187.26 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 418 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 1,742 | 0.85 | 0.01 | $33,976,800.00 | $16,590.23 | 1,200 W | 2,090,880 W | 1,021 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | $129,611.21 | $1,192,423.10 | $5,573,281.86 | $8,658,028.56 | $9,072,784.42 | $9,072,784.42 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 419 | Aries PCIe 6.0 x16 Retimer | $43.75 | — | — | — | — | — | 11 W | — | — | Retimer | Amazon | Astera | — | L1 Abstraction | — | — | — | — | Trainium3 | Compute Tray | AWS-Teton3 PDS-320L Switch Tray | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 420 | Astera Labs Scorpio X 320-lane PCIe Gen 6.0 | $2,000.00 | 32,768 | 16.00 | 0.25 | $65,536,000.00 | $32,000.00 | 300 W | 9,830,400 W | 4,800 W | Scale-Up Switch | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 PDS-320L Switch Tray | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 421 | 112Gb/s SkewClear EXD Cable | $1.00 | 20,971,520 | 10,240.00 | 160.00 | $20,971,520.00 | $10,240.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | Trainium3 | Scale-Up | AWS-Teton3 PDS-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 422 | Aries PCIe 6.0 x16 Retimer | $43.75 | — | — | — | — | — | 11 W | — | — | Retimer | Amazon | Astera | — | L1 Abstraction | — | — | — | — | Trainium3 | Compute Tray | AWS-Teton3 PDS-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 423 | Astera Labs Scorpio X 160-lane PCIe Gen 6.0 | $1,000.00 | 65,536 | 32.00 | 0.50 | $65,536,000.00 | $32,000.00 | 250 W | 16,384,000 W | 8,000 W | Scale-Up Switch | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 PDS-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 424 | EFAv4 Nitro-v6 400G NIC | $480.00 | 139,264 | 17.00 | 1.06 | $66,846,720.00 | $8,160.00 | 50 W | 6,963,200 W | 850 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 425 | Generic 400G AEC | $250.00 | 21,504 | 10.50 | 0.16 | $5,376,000.00 | $2,625.00 | 12 W | 258,048 W | 126 W | AEC | Amazon | Astera | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 426 | Generic 400G AEC | $250.00 | 100,352 | 49.00 | 0.77 | $25,088,000.00 | $12,250.00 | 12 W | 1,204,224 W | 588 W | AEC | Amazon | Credo | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 427 | Generic 400G AEC | $250.00 | 21,504 | 10.50 | 0.16 | $5,376,000.00 | $2,625.00 | 12 W | 258,048 W | 126 W | AEC | Amazon | Marvell | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 428 | Generic 400G DR4 | $260.00 | 13,517 | 6.60 | 0.10 | $3,514,368.00 | $1,716.00 | 10 W | 135,168 W | 66 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 429 | Generic 400G DR4 | $260.00 | 20,275 | 9.90 | 0.15 | $5,271,552.00 | $2,574.00 | 10 W | 202,752 W | 99 W | Transceiver | Amazon | Coherent | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 430 | Generic 400G DR4 | $260.00 | 67,584 | 33.00 | 0.52 | $17,571,840.00 | $8,580.00 | 10 W | 675,840 W | 330 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 431 | Generic 400G DR4 | $260.00 | 33,792 | 16.50 | 0.26 | $8,785,920.00 | $4,290.00 | 10 W | 337,920 W | 165 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 432 | Generic 400G Single Mode | $130.00 | 270,336 | 132.00 | 2.06 | $35,143,680.00 | $17,160.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 433 | Generic 800G DR8 | $500.00 | 20,275 | 9.90 | 0.15 | $10,137,600.00 | $4,950.00 | 16 W | 324,403 W | 158 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 434 | Generic 800G DR8 | $500.00 | 81,101 | 39.60 | 0.62 | $40,550,400.00 | $19,800.00 | 16 W | 1,297,613 W | 634 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 435 | Generic 800G DR8 | $500.00 | 101,376 | 49.50 | 0.77 | $50,688,000.00 | $24,750.00 | 16 W | 1,622,016 W | 792 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 436 | Generic PCIe Gen6 x16 (128Gb/s uni-di) 2-meter AEC | $420.00 | 131,072 | 64.00 | 1.00 | $55,050,240.00 | $26,880.00 | 4 W | 524,288 W | 256 W | AEC | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 PDS-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 437 | Paladin HD 112Gb/s 320 DP (Female) | $73.60 | 65,536 | 32.00 | 0.50 | $4,823,449.60 | $2,355.20 | 0 W | 0 W | 0 W | Backplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | Trainium3 | Scale-Up | AWS-Teton3 PDS-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 438 | Paladin HD 112Gb/s 320 DP (Male) | $220.80 | 65,536 | 32.00 | 0.50 | $14,470,348.80 | $7,065.60 | 0 W | 0 W | 0 W | Backplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | Trainium3 | Scale-Up | AWS-Teton3 PDS-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 439 | Strada Whisper 112Gb/s 80 DP Absolute Connector (Female) | $17.60 | 262,144 | 128.00 | 2.00 | $4,613,734.40 | $2,252.80 | 0 W | 0 W | 0 W | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 PDS-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 440 | Strada Whisper 112Gb/s 80 DP Absolute Connector (Male) | $52.80 | 262,144 | 128.00 | 2.00 | $13,841,203.20 | $6,758.40 | 0 W | 0 W | 0 W | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 PDS-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 441 | Teton3 Backplane Chassis | $7,728.00 | 4,096 | 2.00 | 0.03 | $31,653,888.00 | $15,456.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Others | — | Device Level | — | — | — | — | Trainium3 | Scale-Up | AWS-Teton3 PDS-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 442 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 845 | 0.41 | 0.01 | $4,224,000.00 | $2,062.50 | 450 W | 380,160 W | 186 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 443 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 7,603 | 3.71 | 0.06 | $38,016,000.00 | $18,562.50 | 450 W | 3,421,440 W | 1,671 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 444 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 158 | 0.08 | 0.00 | $3,088,800.00 | $1,508.20 | 1,200 W | 190,080 W | 93 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 445 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 3,010 | 1.47 | 0.02 | $58,687,200.00 | $28,655.86 | 1,200 W | 3,611,520 W | 1,763 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 446 | 112Gb/s SkewClear EXD Cable | $1.00 | 20,971,520 | 10,240.00 | 160.00 | $20,971,520.00 | $10,240.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | Trainium3 | Scale-Up | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 447 | Aries PCIe 6.0 x16 Retimer | $43.75 | — | — | — | — | — | 11 W | — | — | Retimer | Amazon | Astera | — | L1 Abstraction | — | — | — | — | Trainium3 | Compute Tray | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 448 | Astera Labs Scorpio X 320-lane PCIe Gen 6.0 | $2,000.00 | 32,768 | 16.00 | 0.25 | $65,536,000.00 | $32,000.00 | 300 W | 9,830,400 W | 4,800 W | Scale-Up Switch | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 449 | EFAv4 Nitro-v6 400G NIC | $480.00 | 139,264 | 17.00 | 1.06 | $66,846,720.00 | $8,160.00 | 50 W | 6,963,200 W | 850 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 450 | Generic 400G AEC | $250.00 | 1,229 | 0.60 | 0.01 | $307,200.00 | $150.00 | 12 W | 14,746 W | 7 W | AEC | Amazon | Astera | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 451 | Generic 400G AEC | $250.00 | 5,734 | 2.80 | 0.04 | $1,433,600.00 | $700.00 | 12 W | 68,813 W | 34 W | AEC | Amazon | Credo | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 452 | Generic 400G AEC | $250.00 | 1,229 | 0.60 | 0.01 | $307,200.00 | $150.00 | 12 W | 14,746 W | 7 W | AEC | Amazon | Marvell | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 453 | Generic 400G DR4 | $260.00 | 13,517 | 6.60 | 0.10 | $3,514,368.00 | $1,716.00 | 10 W | 135,168 W | 66 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 454 | Generic 400G DR4 | $260.00 | 20,275 | 9.90 | 0.15 | $5,271,552.00 | $2,574.00 | 10 W | 202,752 W | 99 W | Transceiver | Amazon | Coherent | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 455 | Generic 400G DR4 | $260.00 | 67,584 | 33.00 | 0.52 | $17,571,840.00 | $8,580.00 | 10 W | 675,840 W | 330 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 456 | Generic 400G DR4 | $260.00 | 33,792 | 16.50 | 0.26 | $8,785,920.00 | $4,290.00 | 10 W | 337,920 W | 165 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 457 | Generic 400G Single Mode | $130.00 | 270,336 | 132.00 | 2.06 | $35,143,680.00 | $17,160.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 458 | Generic 400G Y Cable AEC | $270.00 | 33,792 | 16.50 | 0.26 | $9,123,840.00 | $4,455.00 | 12 W | 405,504 W | 198 W | AEC | Amazon | Astera | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 459 | Generic 400G Y Cable AEC | $270.00 | 74,342 | 36.30 | 0.57 | $20,072,448.00 | $9,801.00 | 12 W | 892,109 W | 436 W | AEC | Amazon | Credo | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 460 | Generic 400G Y Cable AEC | $270.00 | 27,034 | 13.20 | 0.21 | $7,299,072.00 | $3,564.00 | 12 W | 324,403 W | 158 W | AEC | Amazon | Marvell | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 461 | Generic 800G DR8 | $500.00 | 20,275 | 9.90 | 0.15 | $10,137,600.00 | $4,950.00 | 16 W | 324,403 W | 158 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 462 | Generic 800G DR8 | $500.00 | 81,101 | 39.60 | 0.62 | $40,550,400.00 | $19,800.00 | 16 W | 1,297,613 W | 634 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 463 | Generic 800G DR8 | $500.00 | 101,376 | 49.50 | 0.77 | $50,688,000.00 | $24,750.00 | 16 W | 1,622,016 W | 792 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 464 | Generic PCIe Gen6 x16 (128Gb/s uni-di) 2-meter AEC | $420.00 | 131,072 | 64.00 | 1.00 | $55,050,240.00 | $26,880.00 | 4 W | 524,288 W | 256 W | AEC | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 465 | Paladin HD 112Gb/s 320 DP (Female) | $73.60 | 65,536 | 32.00 | 0.50 | $4,823,449.60 | $2,355.20 | 0 W | 0 W | 0 W | Backplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | Trainium3 | Scale-Up | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 466 | Paladin HD 112Gb/s 320 DP (Male) | $220.80 | 65,536 | 32.00 | 0.50 | $14,470,348.80 | $7,065.60 | 0 W | 0 W | 0 W | Backplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | Trainium3 | Scale-Up | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 467 | Strada Whisper 112Gb/s 80 DP Absolute Connector (Female) | $17.60 | 262,144 | 128.00 | 2.00 | $4,613,734.40 | $2,252.80 | 0 W | 0 W | 0 W | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 468 | Strada Whisper 112Gb/s 80 DP Absolute Connector (Male) | $52.80 | 262,144 | 128.00 | 2.00 | $13,841,203.20 | $6,758.40 | 0 W | 0 W | 0 W | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 469 | Teton3 Backplane Chassis | $7,728.00 | 4,096 | 2.00 | 0.03 | $31,653,888.00 | $15,456.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Others | — | Device Level | — | — | — | — | Trainium3 | Scale-Up | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 470 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 845 | 0.41 | 0.01 | $4,224,000.00 | $2,062.50 | 450 W | 380,160 W | 186 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 471 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 7,603 | 3.71 | 0.06 | $38,016,000.00 | $18,562.50 | 450 W | 3,421,440 W | 1,671 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 472 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 158 | 0.08 | 0.00 | $3,088,800.00 | $1,508.20 | 1,200 W | 190,080 W | 93 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 473 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 3,010 | 1.47 | 0.02 | $58,687,200.00 | $28,655.86 | 1,200 W | 3,611,520 W | 1,763 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PDS-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 474 | 112Gb/s TE Connectivity Madison Cable (1DP per cable) | $1.00 | 12,582,912 | 6,144.00 | 96.00 | $12,582,912.00 | $6,144.00 | — | — | — | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | $48,000.00 | $441,600.00 | $2,064,000.00 | $3,206,400.00 | $3,360,000.00 | $3,360,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 475 | 200G EFAv3 QSFP56 Flat Top DAC | $15.00 | 32,768 | 16.00 | 0.25 | $491,520.00 | $240.00 | 0 W | 0 W | 0 W | DAC | Amazon | Unassigned | — | Device Level | — | — | — | — | Trainium3 | Compute Tray | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | $1,875.00 | $17,250.00 | $80,625.00 | $125,250.00 | $131,250.00 | $131,250.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 476 | Aries PCIe 5.0 x16 Retimer | $35.00 | 262,144 | 128.00 | 2.00 | $9,175,040.00 | $4,480.00 | 9 W | 2,359,296 W | 1,152 W | Retimer | Amazon | Astera | — | L1 Abstraction | — | — | — | — | Trainium3 | Compute Tray | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | $35,000.00 | $322,000.00 | $1,505,000.00 | $2,338,000.00 | $2,450,000.00 | $2,450,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 477 | EFAv4 Nitro-v6 400G NIC | $480.00 | 139,264 | 17.00 | 1.06 | $66,846,720.00 | $8,160.00 | 50 W | 6,963,200 W | 850 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | $255,000.00 | $2,346,000.00 | $10,965,000.00 | $17,034,000.00 | $17,850,000.00 | $17,850,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 478 | Generic 400G AEC | $250.00 | 33,792 | 16.50 | 0.26 | $8,448,000.00 | $4,125.00 | 12 W | 405,504 W | 198 W | AEC | Amazon | Astera | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | $32,226.56 | $296,484.38 | $1,385,742.19 | $2,152,734.38 | $2,255,859.38 | $2,255,859.38 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 479 | Generic 400G AEC | $250.00 | 74,342 | 36.30 | 0.57 | $18,585,600.00 | $9,075.00 | 12 W | 892,109 W | 436 W | AEC | Amazon | Credo | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | $70,898.44 | $652,265.63 | $3,048,632.81 | $4,736,015.63 | $4,962,890.63 | $4,962,890.63 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 480 | Generic 400G AEC | $250.00 | 27,034 | 13.20 | 0.21 | $6,758,400.00 | $3,300.00 | 12 W | 324,403 W | 158 W | AEC | Amazon | Marvell | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | $25,781.25 | $237,187.50 | $1,108,593.75 | $1,722,187.50 | $1,804,687.50 | $1,804,687.50 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 481 | Generic 400G DR4 | $260.00 | 13,517 | 6.60 | 0.10 | $3,514,368.00 | $1,716.00 | 10 W | 135,168 W | 66 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | $13,406.25 | $123,337.50 | $576,468.75 | $895,537.50 | $938,437.50 | $938,437.50 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 482 | Generic 400G DR4 | $260.00 | 20,275 | 9.90 | 0.15 | $5,271,552.00 | $2,574.00 | 10 W | 202,752 W | 99 W | Transceiver | Amazon | Coherent | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | $20,109.38 | $185,006.25 | $864,703.13 | $1,343,306.25 | $1,407,656.25 | $1,407,656.25 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 483 | Generic 400G DR4 | $260.00 | 67,584 | 33.00 | 0.52 | $17,571,840.00 | $8,580.00 | 10 W | 675,840 W | 330 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | $67,031.25 | $616,687.50 | $2,882,343.75 | $4,477,687.50 | $4,692,187.50 | $4,692,187.50 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 484 | Generic 400G DR4 | $260.00 | 33,792 | 16.50 | 0.26 | $8,785,920.00 | $4,290.00 | 10 W | 337,920 W | 165 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | $33,515.63 | $308,343.75 | $1,441,171.88 | $2,238,843.75 | $2,346,093.75 | $2,346,093.75 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 485 | Generic 400G Single Mode | $130.00 | 270,336 | 132.00 | 2.06 | $35,143,680.00 | $17,160.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | $134,062.50 | $1,233,375.00 | $5,764,687.50 | $8,955,375.00 | $9,384,375.00 | $9,384,375.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 486 | Generic 800G DR8 | $500.00 | 20,275 | 9.90 | 0.15 | $10,137,600.00 | $4,950.00 | 16 W | 324,403 W | 158 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | $38,671.88 | $355,781.25 | $1,662,890.63 | $2,583,281.25 | $2,707,031.25 | $2,707,031.25 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 487 | Generic 800G DR8 | $500.00 | 81,101 | 39.60 | 0.62 | $40,550,400.00 | $19,800.00 | 16 W | 1,297,613 W | 634 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | $154,687.50 | $1,423,125.00 | $6,651,562.50 | $10,333,125.00 | $10,828,125.00 | $10,828,125.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 488 | Generic 800G DR8 | $500.00 | 101,376 | 49.50 | 0.77 | $50,688,000.00 | $24,750.00 | 16 W | 1,622,016 W | 792 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | $193,359.38 | $1,778,906.25 | $8,314,453.13 | $12,916,406.25 | $13,535,156.25 | $13,535,156.25 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 489 | Generic PCIe Gen6 x16 (128Gb/s uni-di) 2-meter AEC | $420.00 | 131,072 | 64.00 | 1.00 | $55,050,240.00 | $26,880.00 | 4 W | 524,288 W | 256 W | AEC | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | $210,000.00 | $1,932,000.00 | $9,030,000.00 | $14,028,000.00 | $14,700,000.00 | $14,700,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 490 | Strada Whisper 112Gb/s 64 DP Absolute Connector (Female) | $14.08 | 393,216 | 192.00 | 3.00 | $5,536,481.28 | $2,703.36 | 0 W | 0 W | 0 W | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | $21,120.00 | $194,304.00 | $908,160.00 | $1,410,816.00 | $1,478,400.00 | $1,478,400.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 491 | Strada Whisper 112Gb/s 64 DP Absolute Connector (Male) | $42.24 | 393,216 | 192.00 | 3.00 | $16,609,443.84 | $8,110.08 | 0 W | 0 W | 0 W | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | $63,360.00 | $582,912.00 | $2,724,480.00 | $4,232,448.00 | $4,435,200.00 | $4,435,200.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 492 | Teton3 Backplane Chassis | $7,728.00 | 8,192 | 4.00 | 0.06 | $63,307,776.00 | $30,912.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Others | — | Device Level | — | — | — | — | Trainium3 | Scale-Up | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | $241,500.00 | $2,221,800.00 | $10,384,500.00 | $16,132,200.00 | $16,905,000.00 | $16,905,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 493 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 8,026 | 3.92 | 0.06 | $40,128,000.00 | $19,593.75 | 450 W | 3,611,520 W | 1,763 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | $153,076.17 | $1,408,300.78 | $6,582,275.39 | $10,225,488.28 | $10,715,332.03 | $10,715,332.03 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 494 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 422 | 0.21 | 0.00 | $2,112,000.00 | $1,031.25 | 450 W | 190,080 W | 93 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | $8,056.64 | $74,121.09 | $346,435.55 | $538,183.59 | $563,964.84 | $563,964.84 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 495 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 1,426 | 0.70 | 0.01 | $27,799,200.00 | $13,573.83 | 1,200 W | 1,710,720 W | 835 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | $106,045.53 | $975,618.90 | $4,559,957.89 | $7,083,841.55 | $7,423,187.26 | $7,423,187.26 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 496 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 1,742 | 0.85 | 0.01 | $33,976,800.00 | $16,590.23 | 1,200 W | 2,090,880 W | 1,021 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | $129,611.21 | $1,192,423.10 | $5,573,281.86 | $8,658,028.56 | $9,072,784.42 | $9,072,784.42 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 497 | EFAv2 Nitro-v4 100G NIC | $150.00 | 12,288 | 8.00 | 0.50 | $1,843,200.00 | $1,200.00 | 19 W | 233,472 W | 152 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | Trainium1 | Backend | AWS-Trainium1-Default | $1,764,000.00 | $1,398,200.00 | $2,546,200.00 | $3,356,400.00 | $2,824,000.00 | $4,039,400.00 | $5,500,000.00 | $4,750,000.00 | $3,500,000.00 | $176,325.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 498 | Generic 100G AEC | $70.00 | 11,059 | 7.20 | 0.45 | $774,144.00 | $504.00 | 8 W | 88,474 W | 58 W | AEC | Amazon | Credo | — | Device Level | — | — | — | — | Trainium1 | Backend | AWS-Trainium1-Default | $740,880.00 | $587,244.00 | $1,069,404.00 | $1,409,688.00 | $1,186,080.00 | $1,696,548.00 | $2,310,000.00 | $1,995,000.00 | $1,470,000.00 | $74,056.50 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 499 | Generic 100G AEC | $70.00 | 1,229 | 0.80 | 0.05 | $86,016.00 | $56.00 | 8 W | 9,830 W | 6 W | AEC | Amazon | Others | — | Device Level | — | — | — | — | Trainium1 | Backend | AWS-Trainium1-Default | $82,320.00 | $65,249.33 | $118,822.67 | $156,632.00 | $131,786.67 | $188,505.33 | $256,666.67 | $221,666.67 | $163,333.33 | $8,228.50 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 500 | Generic 100G Multimode | $150.00 | 19,661 | 12.80 | 0.80 | $2,949,120.00 | $1,920.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Corning | — | Device Level | — | — | — | — | Trainium1 | Backend | AWS-Trainium1-Default | $2,822,400.00 | $2,237,120.00 | $4,073,920.00 | $5,370,240.00 | $4,518,400.00 | $6,463,040.00 | $8,800,000.00 | $7,600,000.00 | $5,600,000.00 | $282,120.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |