Live DB — analyst tables
Test
XPU Shipments
NetworkingDB
Every Cluster BoM Summary row joined to its ClusterDB quarterly series — XPU counts, equipment units and equipment spend per quarter.
Live networking_db (read-only)6,421 rows · 4,391 with matched XPU seriesbuilt 7/23/2026, 11:16:18 AM
| # | Item | Unit Cost | Quantity (per Cluster) | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name | 1Q23 | 2Q23 | 3Q23 | 4Q23 | 1Q24 | 2Q24 | 3Q24 | 4Q24 | 1Q25 | 2Q25 | 3Q25 | 4Q25 | 1Q26 | 2Q26 | 3Q26 | 4Q26 | 1Q27 | 2Q27 | 3Q27 | 4Q27 | 1Q28 | 2Q28 | 3Q28 | 4Q28 | 1Q29 | 2Q29 | 3Q29 | 4Q29 | 1Q30 | 2Q30 | 3Q30 | 4Q30 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 301 | Generic 400G DR4 | $260.00 | 131,072 | 72.00 | 1.00 | $34,078,720.00 | $18,720.00 | 10 W | 1,310,720 W | 720 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 3,960 | 1,872 | 4,064 | 1,968 | 1,656 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 302 | Generic 400G DR4 | $260.00 | 65,536 | 36.00 | 0.50 | $17,039,360.00 | $9,360.00 | 10 W | 655,360 W | 360 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 1,980 | 936 | 2,032 | 984 | 828 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 303 | Generic 400G Single Mode | $130.00 | 524,288 | 288.00 | 4.00 | $68,157,440.00 | $37,440.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 15,840 | 7,488 | 16,256 | 7,872 | 6,624 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 304 | Generic 800G DR8 | $500.00 | 39,322 | 21.60 | 0.30 | $19,660,800.00 | $10,800.00 | 16 W | 629,146 W | 346 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 1,188 | 562 | 1,219 | 590 | 497 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 305 | Generic 800G DR8 | $500.00 | 157,286 | 86.40 | 1.20 | $78,643,200.00 | $43,200.00 | 16 W | 2,516,582 W | 1,382 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 4,752 | 2,246 | 4,877 | 2,362 | 1,987 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 306 | Generic 800G DR8 | $500.00 | 196,608 | 108.00 | 1.50 | $98,304,000.00 | $54,000.00 | 16 W | 3,145,728 W | 1,728 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 5,940 | 2,808 | 6,096 | 2,952 | 2,484 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 307 | Generic PCIe Gen6 x16 2-meter DAC | $85.00 | 131,072 | 72.00 | 1.00 | $11,141,120.00 | $6,120.00 | 0 W | 0 W | 0 W | DAC | Amazon | Astera | — | Device Level | — | — | PCIe | — | B300 | Compute Tray | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 3,960 | 1,872 | 4,064 | 1,968 | 1,656 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 308 | Nvidia NVSwitch 5.0 (NVLink 5) | $3,200.00 | 32,768 | 18.00 | 0.25 | $104,857,600.00 | $57,600.00 | 407 W | 13,349,683 W | 7,333 W | Scale-Up Switch | Amazon | Nvidia | — | Device Level | — | — | NVLink | — | B300 | Scale-Up | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 990 | 468 | 1,016 | 492 | 414 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 309 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 1,638 | 0.90 | 0.01 | $8,192,000.00 | $4,500.00 | 450 W | 737,280 W | 405 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 50 | 23 | 51 | 25 | 21 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 310 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 14,746 | 8.10 | 0.11 | $73,728,000.00 | $40,500.00 | 450 W | 6,635,520 W | 3,645 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 446 | 211 | 457 | 221 | 186 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 311 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 307 | 0.17 | 0.00 | $5,990,400.00 | $3,290.63 | 1,200 W | 368,640 W | 203 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 9 | 4 | 10 | 5 | 4 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 312 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 5,837 | 3.21 | 0.04 | $113,817,600.00 | $62,521.88 | 1,200 W | 7,004,160 W | 3,848 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 176 | 83 | 181 | 88 | 74 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 313 | 112Gb/s TE Connectivity Madison Cable (1DP per cable) | $1.00 | 12,582,912 | 6,144.00 | 96.00 | $12,582,912.00 | $6,144.00 | — | — | — | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium2 | Scale-Up | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 480,000 | 2,400,000 | 13,920,000 | 19,680,000 | 36,000,000 | 42,594,240 | 25,884,480 | 30,240,000 | 1,825,920 | — | 4,067,520 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 314 | 200G EFAv3 QSFP56 Flat Top DAC | $15.00 | 14,746 | 7.20 | 0.11 | $221,184.00 | $108.00 | 0 W | 0 W | 0 W | DAC | Amazon | Amphenol | — | Device Level | — | — | — | — | Trainium2 | Compute Tray | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 563 | 2,813 | 16,313 | 23,063 | 42,188 | 49,915 | 30,333 | 35,438 | 2,140 | — | 4,767 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 315 | 200G EFAv3 QSFP56 Flat Top DAC | $15.00 | 11,469 | 5.60 | 0.09 | $172,032.00 | $84.00 | 0 W | 0 W | 0 W | DAC | Amazon | Molex | — | Device Level | — | — | — | — | Trainium2 | Compute Tray | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 438 | 2,188 | 12,688 | 17,938 | 32,813 | 38,823 | 23,593 | 27,563 | 1,664 | — | 3,707 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 316 | 200G EFAv3 QSFP56 Flat Top DAC | $15.00 | 6,554 | 3.20 | 0.05 | $98,304.00 | $48.00 | 0 W | 0 W | 0 W | DAC | Amazon | TE | — | Device Level | — | — | — | — | Trainium2 | Compute Tray | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 250 | 1,250 | 7,250 | 10,250 | 18,750 | 22,185 | 13,482 | 15,750 | 951 | — | 2,119 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 317 | Aries PCIe 5.0 x16 Retimer | $35.00 | 262,144 | 128.00 | 2.00 | $9,175,040.00 | $4,480.00 | 9 W | 2,359,296 W | 1,152 W | Retimer | Amazon | Astera | — | L1 Abstraction | — | — | — | — | Trainium2 | Compute Tray | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 10,000 | 50,000 | 290,000 | 410,000 | 750,000 | 887,380 | 539,260 | 630,000 | 38,040 | — | 84,740 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 318 | EFAv3 Nitro-v5 200G NIC | $300.00 | 139,264 | 17.00 | 1.06 | $41,779,200.00 | $5,100.00 | 38 W | 5,292,032 W | 646 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 5,313 | 26,563 | 154,063 | 217,813 | 398,438 | 471,421 | 286,482 | 334,688 | 20,209 | — | 45,018 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 319 | Generic 400G DR4 | $260.00 | 6,554 | 3.20 | 0.05 | $1,703,936.00 | $832.00 | 10 W | 65,536 W | 32 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 250 | 1,250 | 7,250 | 10,250 | 18,750 | 22,185 | 13,482 | 15,750 | 951 | — | 2,119 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 320 | Generic 400G DR4 | $260.00 | 9,830 | 4.80 | 0.08 | $2,555,904.00 | $1,248.00 | 10 W | 98,304 W | 48 W | Transceiver | Amazon | Coherent | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 375 | 1,875 | 10,875 | 15,375 | 28,125 | 33,277 | 20,222 | 23,625 | 1,427 | — | 3,178 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 321 | Generic 400G DR4 | $260.00 | 32,768 | 16.00 | 0.25 | $8,519,680.00 | $4,160.00 | 10 W | 327,680 W | 160 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 1,250 | 6,250 | 36,250 | 51,250 | 93,750 | 110,923 | 67,408 | 78,750 | 4,755 | — | 10,593 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 322 | Generic 400G DR4 | $260.00 | 16,384 | 8.00 | 0.13 | $4,259,840.00 | $2,080.00 | 10 W | 163,840 W | 80 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 625 | 3,125 | 18,125 | 25,625 | 46,875 | 55,461 | 33,704 | 39,375 | 2,378 | — | 5,296 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 323 | Generic 400G Single Mode | $130.00 | 131,072 | 64.00 | 1.00 | $17,039,360.00 | $8,320.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 5,000 | 25,000 | 145,000 | 205,000 | 375,000 | 443,690 | 269,630 | 315,000 | 19,020 | — | 42,370 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 324 | Generic 400G Y Cable AEC | $270.00 | 10,445 | 5.10 | 0.08 | $2,820,096.00 | $1,377.00 | 12 W | 125,338 W | 61 W | AEC | Amazon | Astera | — | Device Level | — | — | — | — | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 398 | 1,992 | 11,555 | 16,336 | 29,883 | 35,357 | 21,486 | 25,102 | 1,516 | — | 3,376 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 325 | Generic 400G Y Cable AEC | $270.00 | 59,187 | 28.90 | 0.45 | $15,980,544.00 | $7,803.00 | 12 W | 710,246 W | 347 W | AEC | Amazon | Credo | — | Device Level | — | — | — | — | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 2,258 | 11,289 | 65,477 | 92,570 | 169,336 | 200,354 | 121,755 | 142,242 | 8,589 | — | 19,133 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 326 | Generic 800G DR8 | $500.00 | 19,661 | 9.60 | 0.15 | $9,830,400.00 | $4,800.00 | 16 W | 314,573 W | 154 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 750 | 3,750 | 21,750 | 30,750 | 56,250 | 66,554 | 40,445 | 47,250 | 2,853 | — | 6,356 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 327 | Generic 800G DR8 | $500.00 | 78,643 | 38.40 | 0.60 | $39,321,600.00 | $19,200.00 | 16 W | 1,258,291 W | 614 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 3,000 | 15,000 | 87,000 | 123,000 | 225,000 | 266,214 | 161,778 | 189,000 | 11,412 | — | 25,422 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 328 | Generic 800G DR8 | $500.00 | 98,304 | 48.00 | 0.75 | $49,152,000.00 | $24,000.00 | 16 W | 1,572,864 W | 768 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 3,750 | 18,750 | 108,750 | 153,750 | 281,250 | 332,768 | 202,223 | 236,250 | 14,265 | — | 31,778 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 329 | Generic PCIe Gen5 x16 (32Gb/s uni-di) 2-meter AEC | $350.00 | 131,072 | 64.00 | 1.00 | $45,875,200.00 | $22,400.00 | 3 W | 393,216 W | 192 W | AEC | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium2 | Scale-Up | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 5,000 | 25,000 | 145,000 | 205,000 | 375,000 | 443,690 | 269,630 | 315,000 | 19,020 | — | 42,370 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 330 | Strada Whisper 112Gb/s 64 DP Absolute Connector (Female) | $14.08 | 393,216 | 192.00 | 3.00 | $5,536,481.28 | $2,703.36 | 0 W | 0 W | 0 W | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium2 | Scale-Up | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 15,000 | 75,000 | 435,000 | 615,000 | 1,125,000 | 1,331,070 | 808,890 | 945,000 | 57,060 | — | 127,110 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 331 | Strada Whisper 112Gb/s 64 DP Absolute Connector (Male) | $42.24 | 393,216 | 192.00 | 3.00 | $16,609,443.84 | $8,110.08 | 0 W | 0 W | 0 W | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium2 | Scale-Up | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 15,000 | 75,000 | 435,000 | 615,000 | 1,125,000 | 1,331,070 | 808,890 | 945,000 | 57,060 | — | 127,110 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 332 | Teton2 Backplane Chassis | $7,728.00 | 8,192 | 4.00 | 0.06 | $63,307,776.00 | $30,912.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Others | — | Device Level | — | — | — | — | Trainium2 | Scale-Up | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 313 | 1,563 | 9,063 | 12,813 | 23,438 | 27,731 | 16,852 | 19,688 | 1,189 | — | 2,648 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 333 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 1,024 | 0.50 | 0.01 | $5,120,000.00 | $2,500.00 | 450 W | 460,800 W | 225 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 39 | 195 | 1,133 | 1,602 | 2,930 | 3,466 | 2,106 | 2,461 | 149 | — | 331 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 334 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 9,216 | 4.50 | 0.07 | $46,080,000.00 | $22,500.00 | 450 W | 4,147,200 W | 2,025 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 352 | 1,758 | 10,195 | 14,414 | 26,367 | 31,197 | 18,958 | 22,148 | 1,337 | — | 2,979 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 335 | Aries PCIe 6.0 x16 Retimer | $43.75 | 131,072 | 144.00 | 1.00 | $5,734,400.00 | $6,300.00 | 11 W | 1,441,792 W | 1,584 W | Retimer | Amazon | Astera | — | L1 Abstraction | — | — | — | — | Trainium3 | Compute Tray | AWS-Teton3 MAX-320L Switch Tray | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 336 | Aries PG6032 16L/32L Gearbox | $20.00 | 65,536 | 72.00 | 0.50 | $1,310,720.00 | $1,440.00 | 3 W | 196,608 W | 216 W | Gearbox | Amazon | Astera | — | L1 Abstraction | — | — | — | — | Trainium3 | Compute Tray | AWS-Teton3 MAX-320L Switch Tray | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 337 | Astera Labs Scorpio-P 32-Lane PCIe Gen 6.0 | $70.00 | 65,536 | 72.00 | 0.50 | $4,587,520.00 | $5,040.00 | 80 W | 5,242,880 W | 5,760 W | Scale-Up Switch | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium3 | Compute Tray | AWS-Teton3 MAX-320L Switch Tray | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 338 | Astera Labs Scorpio X 320-lane PCIe Gen 6.0 | $2,000.00 | 36,409 | 40.00 | 0.28 | $72,817,777.78 | $80,000.00 | 300 W | 10,922,667 W | 12,000 W | Scale-Up Switch | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-320L Switch Tray | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 339 | 112Gb/s SkewClear EXD Cable | $1.00 | 23,301,689 | 25,600.00 | 177.78 | $23,301,688.89 | $25,600.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 340 | Aries PCIe 6.0 x16 Retimer | $43.75 | 131,072 | 144.00 | 1.00 | $5,734,400.00 | $6,300.00 | 11 W | 1,441,792 W | 1,584 W | Retimer | Amazon | Astera | — | L1 Abstraction | — | — | — | — | Trainium3 | Compute Tray | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 341 | Aries PG6032 16L/32L Gearbox | $20.00 | 65,536 | 72.00 | 0.50 | $1,310,720.00 | $1,440.00 | 3 W | 196,608 W | 216 W | Gearbox | Amazon | Astera | — | L1 Abstraction | — | — | — | — | Trainium3 | Compute Tray | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 342 | Astera Labs Scorpio-P 32-Lane PCIe Gen 6.0 | $70.00 | 65,536 | 72.00 | 0.50 | $4,587,520.00 | $5,040.00 | 80 W | 5,242,880 W | 5,760 W | Scale-Up Switch | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium3 | Compute Tray | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 343 | Astera Labs Scorpio-P 32-Lane PCIe Gen 6.0 | $70.00 | 262,144 | 288.00 | 2.00 | $18,350,080.00 | $20,160.00 | 80 W | 20,971,520 W | 23,040 W | Scale-Up Switch | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 344 | Astera Labs Scorpio X 160-lane PCIe Gen 6.0 | $1,000.00 | 72,818 | 80.00 | 0.56 | $72,817,777.78 | $80,000.00 | 250 W | 18,204,444 W | 20,000 W | Scale-Up Switch | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 345 | EFAv4 Nitro-v6 400G NIC | $480.00 | 131,072 | 4.00 | 1.00 | $62,914,560.00 | $1,920.00 | 50 W | 6,553,600 W | 200 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 346 | Generic 400G AEC | $250.00 | 19,661 | 21.60 | 0.15 | $4,915,200.00 | $5,400.00 | 12 W | 235,930 W | 259 W | AEC | Amazon | Astera | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 347 | Generic 400G AEC | $250.00 | 91,750 | 100.80 | 0.70 | $22,937,600.00 | $25,200.00 | 12 W | 1,101,005 W | 1,210 W | AEC | Amazon | Credo | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 348 | Generic 400G AEC | $250.00 | 19,661 | 21.60 | 0.15 | $4,915,200.00 | $5,400.00 | 12 W | 235,930 W | 259 W | AEC | Amazon | Marvell | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 349 | Generic 400G DR4 | $260.00 | 13,107 | 14.40 | 0.10 | $3,407,872.00 | $3,744.00 | 10 W | 131,072 W | 144 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 350 | Generic 400G DR4 | $260.00 | 19,661 | 21.60 | 0.15 | $5,111,808.00 | $5,616.00 | 10 W | 196,608 W | 216 W | Transceiver | Amazon | Coherent | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 351 | Generic 400G DR4 | $260.00 | 65,536 | 72.00 | 0.50 | $17,039,360.00 | $18,720.00 | 10 W | 655,360 W | 720 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 352 | Generic 400G DR4 | $260.00 | 32,768 | 36.00 | 0.25 | $8,519,680.00 | $9,360.00 | 10 W | 327,680 W | 360 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 353 | Generic 400G Single Mode | $130.00 | 262,144 | 288.00 | 2.00 | $34,078,720.00 | $37,440.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 354 | Generic 800G DR8 | $500.00 | 19,661 | 21.60 | 0.15 | $9,830,400.00 | $10,800.00 | 16 W | 314,573 W | 346 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 355 | Generic 800G DR8 | $500.00 | 78,643 | 86.40 | 0.60 | $39,321,600.00 | $43,200.00 | 16 W | 1,258,291 W | 1,382 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 356 | Generic 800G DR8 | $500.00 | 98,304 | 108.00 | 0.75 | $49,152,000.00 | $54,000.00 | 16 W | 1,572,864 W | 1,728 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 357 | Generic PCIe Gen6 x16 (128Gb/s uni-di) 2-meter AEC | $420.00 | 65,536 | 72.00 | 0.50 | $27,525,120.00 | $30,240.00 | 4 W | 262,144 W | 288 W | AEC | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 358 | Paladin HD 112Gb/s 320 DP (Female) | $73.60 | 72,818 | 80.00 | 0.56 | $5,359,388.44 | $5,888.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 359 | Paladin HD 112Gb/s 320 DP (Male) | $220.80 | 72,818 | 80.00 | 0.56 | $16,078,165.33 | $17,664.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 360 | Strada Whisper 112Gb/s 80 DP Absolute Connector (Female) | $17.60 | 262,144 | 288.00 | 2.00 | $4,613,734.40 | $5,068.80 | 0 W | 0 W | 0 W | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 361 | Strada Whisper 112Gb/s 80 DP Absolute Connector (Male) | $52.80 | 262,144 | 288.00 | 2.00 | $13,841,203.20 | $15,206.40 | 0 W | 0 W | 0 W | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 362 | Teton3 Backplane Chassis | $7,728.00 | 1,820 | 2.00 | 0.01 | $14,068,394.67 | $15,456.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Others | — | Device Level | — | — | — | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 363 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 819 | 0.90 | 0.01 | $4,096,000.00 | $4,500.00 | 450 W | 368,640 W | 405 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 364 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 7,373 | 8.10 | 0.06 | $36,864,000.00 | $40,500.00 | 450 W | 3,317,760 W | 3,645 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 365 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 154 | 0.17 | 0.00 | $2,995,200.00 | $3,290.63 | 1,200 W | 184,320 W | 203 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 366 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 2,918 | 3.21 | 0.02 | $56,908,800.00 | $62,521.88 | 1,200 W | 3,502,080 W | 3,848 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-160L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 367 | 112Gb/s SkewClear EXD Cable | $1.00 | 23,301,689 | 25,600.00 | 177.78 | $23,301,688.89 | $25,600.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 368 | Aries PCIe 6.0 x16 Retimer | $43.75 | 131,072 | 144.00 | 1.00 | $5,734,400.00 | $6,300.00 | 11 W | 1,441,792 W | 1,584 W | Retimer | Amazon | Astera | — | L1 Abstraction | — | — | — | — | Trainium3 | Compute Tray | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 369 | Aries PG6032 16L/32L Gearbox | $20.00 | 65,536 | 72.00 | 0.50 | $1,310,720.00 | $1,440.00 | 3 W | 196,608 W | 216 W | Gearbox | Amazon | Astera | — | L1 Abstraction | — | — | — | — | Trainium3 | Compute Tray | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 370 | Astera Labs Scorpio-P 32-Lane PCIe Gen 6.0 | $70.00 | 65,536 | 72.00 | 0.50 | $4,587,520.00 | $5,040.00 | 80 W | 5,242,880 W | 5,760 W | Scale-Up Switch | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium3 | Compute Tray | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 371 | Astera Labs Scorpio-P 32-Lane PCIe Gen 6.0 | $70.00 | 262,144 | 288.00 | 2.00 | $18,350,080.00 | $20,160.00 | 80 W | 20,971,520 W | 23,040 W | Scale-Up Switch | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 372 | Astera Labs Scorpio X 320-lane PCIe Gen 6.0 | $2,000.00 | 36,409 | 40.00 | 0.28 | $72,817,777.78 | $80,000.00 | 300 W | 10,922,667 W | 12,000 W | Scale-Up Switch | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 373 | EFAv4 Nitro-v6 400G NIC | $480.00 | 65,536 | 2.00 | 0.50 | $31,457,280.00 | $960.00 | 50 W | 3,276,800 W | 100 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 374 | Generic 400G AEC | $250.00 | 19,661 | 21.60 | 0.15 | $4,915,200.00 | $5,400.00 | 12 W | 235,930 W | 259 W | AEC | Amazon | Astera | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 375 | Generic 400G AEC | $250.00 | 91,750 | 100.80 | 0.70 | $22,937,600.00 | $25,200.00 | 12 W | 1,101,005 W | 1,210 W | AEC | Amazon | Credo | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 376 | Generic 400G AEC | $250.00 | 19,661 | 21.60 | 0.15 | $4,915,200.00 | $5,400.00 | 12 W | 235,930 W | 259 W | AEC | Amazon | Marvell | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 377 | Generic 400G DR4 | $260.00 | 13,107 | 14.40 | 0.10 | $3,407,872.00 | $3,744.00 | 10 W | 131,072 W | 144 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 378 | Generic 400G DR4 | $260.00 | 19,661 | 21.60 | 0.15 | $5,111,808.00 | $5,616.00 | 10 W | 196,608 W | 216 W | Transceiver | Amazon | Coherent | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 379 | Generic 400G DR4 | $260.00 | 65,536 | 72.00 | 0.50 | $17,039,360.00 | $18,720.00 | 10 W | 655,360 W | 720 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 380 | Generic 400G DR4 | $260.00 | 32,768 | 36.00 | 0.25 | $8,519,680.00 | $9,360.00 | 10 W | 327,680 W | 360 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 381 | Generic 400G Single Mode | $130.00 | 262,144 | 288.00 | 2.00 | $34,078,720.00 | $37,440.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 382 | Generic 800G DR8 | $500.00 | 19,661 | 21.60 | 0.15 | $9,830,400.00 | $10,800.00 | 16 W | 314,573 W | 346 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 383 | Generic 800G DR8 | $500.00 | 78,643 | 86.40 | 0.60 | $39,321,600.00 | $43,200.00 | 16 W | 1,258,291 W | 1,382 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 384 | Generic 800G DR8 | $500.00 | 98,304 | 108.00 | 0.75 | $49,152,000.00 | $54,000.00 | 16 W | 1,572,864 W | 1,728 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 385 | Generic PCIe Gen6 x16 (128Gb/s uni-di) 2-meter AEC | $420.00 | 65,536 | 72.00 | 0.50 | $27,525,120.00 | $30,240.00 | 4 W | 262,144 W | 288 W | AEC | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 386 | Paladin HD 112Gb/s 320 DP (Female) | $73.60 | 72,818 | 80.00 | 0.56 | $5,359,388.44 | $5,888.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 387 | Paladin HD 112Gb/s 320 DP (Male) | $220.80 | 72,818 | 80.00 | 0.56 | $16,078,165.33 | $17,664.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 388 | Strada Whisper 112Gb/s 80 DP Absolute Connector (Female) | $17.60 | 262,144 | 288.00 | 2.00 | $4,613,734.40 | $5,068.80 | 0 W | 0 W | 0 W | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 389 | Strada Whisper 112Gb/s 80 DP Absolute Connector (Male) | $52.80 | 262,144 | 288.00 | 2.00 | $13,841,203.20 | $15,206.40 | 0 W | 0 W | 0 W | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 390 | Teton3 Backplane Chassis | $7,728.00 | 1,820 | 2.00 | 0.01 | $14,068,394.67 | $15,456.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Others | — | Device Level | — | — | — | — | Trainium3 | Scale-Up | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 391 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 819 | 0.90 | 0.01 | $4,096,000.00 | $4,500.00 | 450 W | 368,640 W | 405 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 392 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 7,373 | 8.10 | 0.06 | $36,864,000.00 | $40,500.00 | 450 W | 3,317,760 W | 3,645 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 393 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 154 | 0.17 | 0.00 | $2,995,200.00 | $3,290.63 | 1,200 W | 184,320 W | 203 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 394 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 2,918 | 3.21 | 0.02 | $56,908,800.00 | $62,521.88 | 1,200 W | 3,502,080 W | 3,848 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 MAX-Nv6-EFA-WB-320L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 395 | 112Gb/s TE Connectivity Madison Cable (1DP per cable) | $1.00 | 12,582,912 | 6,144.00 | 96.00 | $12,582,912.00 | $6,144.00 | — | — | — | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 48,000 | 441,600 | 2,064,000 | 3,206,400 | 3,360,000 | 3,360,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 396 | 200G EFAv4 QSFP56 Flat Top DAC | $15.00 | 14,746 | 7.20 | 0.11 | $221,184.00 | $108.00 | 0 W | 0 W | 0 W | DAC | Amazon | Amphenol | — | Device Level | — | — | — | — | Trainium3 | Compute Tray | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 56 | 518 | 2,419 | 3,758 | 3,938 | 3,938 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 397 | 200G EFAv4 QSFP56 Flat Top DAC | $15.00 | 11,469 | 5.60 | 0.09 | $172,032.00 | $84.00 | 0 W | 0 W | 0 W | DAC | Amazon | Molex | — | Device Level | — | — | — | — | Trainium3 | Compute Tray | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 44 | 403 | 1,881 | 2,923 | 3,063 | 3,063 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 398 | 200G EFAv4 QSFP56 Flat Top DAC | $15.00 | 6,554 | 3.20 | 0.05 | $98,304.00 | $48.00 | 0 W | 0 W | 0 W | DAC | Amazon | TE | — | Device Level | — | — | — | — | Trainium3 | Compute Tray | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 25 | 230 | 1,075 | 1,670 | 1,750 | 1,750 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 399 | Aries PCIe 6.0 x16 Retimer | $43.75 | 131,072 | 64.00 | 1.00 | $5,734,400.00 | $2,800.00 | 11 W | 1,441,792 W | 704 W | Retimer | Amazon | Astera | — | L1 Abstraction | — | — | — | — | Trainium3 | Compute Tray | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 400 | EFAv4 Nitro-v6 400G NIC | $480.00 | 139,264 | 17.00 | 1.06 | $66,846,720.00 | $8,160.00 | 50 W | 6,963,200 W | 850 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 531 | 4,888 | 22,844 | 35,488 | 37,188 | 37,188 | — | — | — | — | — | — | — | — | — | — | — | — | — |