| # | Item | Unit Cost | Quantity (per Cluster) | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name | 1Q23 | 2Q23 | 3Q23 | 4Q23 | 1Q24 | 2Q24 | 3Q24 | 4Q24 | 1Q25 | 2Q25 | 3Q25 | 4Q25 | 1Q26 | 2Q26 | 3Q26 | 4Q26 | 1Q27 | 2Q27 | 3Q27 | 4Q27 | 1Q28 | 2Q28 | 3Q28 | 4Q28 | 1Q29 | 2Q29 | 3Q29 | 4Q29 | 1Q30 | 2Q30 | 3Q30 | 4Q30 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 301 | Generic 400G DR4 | $260.00 | 13,517 | 6.60 | 0.10 | $3,514,368.00 | $1,716.00 | 10 W | 135,168 W | 66 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 302 | Generic 400G DR4 | $260.00 | 20,275 | 9.90 | 0.15 | $5,271,552.00 | $2,574.00 | 10 W | 202,752 W | 99 W | Transceiver | Amazon | Coherent | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 303 | Generic 400G DR4 | $260.00 | 67,584 | 33.00 | 0.52 | $17,571,840.00 | $8,580.00 | 10 W | 675,840 W | 330 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 304 | Generic 400G DR4 | $260.00 | 33,792 | 16.50 | 0.26 | $8,785,920.00 | $4,290.00 | 10 W | 337,920 W | 165 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 305 | Generic 400G Single Mode | $130.00 | 270,336 | 132.00 | 2.06 | $35,143,680.00 | $17,160.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 306 | Generic 800G DR8 | $500.00 | 20,275 | 9.90 | 0.15 | $10,137,600.00 | $4,950.00 | 16 W | 324,403 W | 158 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 307 | Generic 800G DR8 | $500.00 | 81,101 | 39.60 | 0.62 | $40,550,400.00 | $19,800.00 | 16 W | 1,297,613 W | 634 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 308 | Generic 800G DR8 | $500.00 | 101,376 | 49.50 | 0.77 | $50,688,000.00 | $24,750.00 | 16 W | 1,622,016 W | 792 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 309 | Generic PCIe Gen6 x16 (128Gb/s uni-di) 2-meter AEC | $420.00 | 131,072 | 64.00 | 1.00 | $55,050,240.00 | $26,880.00 | 4 W | 524,288 W | 256 W | AEC | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 310 | Strada Whisper 112Gb/s 64 DP Absolute Connector (Female) | $14.08 | 393,216 | 192.00 | 3.00 | $5,536,481.28 | $2,703.36 | 0 W | 0 W | 0 W | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 311 | Strada Whisper 112Gb/s 64 DP Absolute Connector (Male) | $42.24 | 393,216 | 192.00 | 3.00 | $16,609,443.84 | $8,110.08 | 0 W | 0 W | 0 W | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 312 | Teton3 Backplane Chassis | $7,728.00 | 8,192 | 4.00 | 0.06 | $63,307,776.00 | $30,912.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Others | — | Device Level | — | — | — | — | Trainium3 | Scale-Up | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 313 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 8,026 | 3.92 | 0.06 | $40,128,000.00 | $19,593.75 | 450 W | 3,611,520 W | 1,763 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 314 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 422 | 0.21 | 0.00 | $2,112,000.00 | $1,031.25 | 450 W | 190,080 W | 93 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 315 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 1,426 | 0.70 | 0.01 | $27,799,200.00 | $13,573.83 | 1,200 W | 1,710,720 W | 835 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 316 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 1,742 | 0.85 | 0.01 | $33,976,800.00 | $16,590.23 | 1,200 W | 2,090,880 W | 1,021 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 317 | EFAv2 Nitro-v4 100G NIC | $150.00 | 12,288 | 8.00 | 0.50 | $1,843,200.00 | $1,200.00 | 19 W | 233,472 W | 152 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | Trainium1 | Backend | AWS-Trainium1-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 318 | Generic 100G AEC | $70.00 | 11,059 | 7.20 | 0.45 | $774,144.00 | $504.00 | 8 W | 88,474 W | 58 W | AEC | Amazon | Credo | — | Device Level | — | — | — | — | Trainium1 | Backend | AWS-Trainium1-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 319 | Generic 100G AEC | $70.00 | 1,229 | 0.80 | 0.05 | $86,016.00 | $56.00 | 8 W | 9,830 W | 6 W | AEC | Amazon | Others | — | Device Level | — | — | — | — | Trainium1 | Backend | AWS-Trainium1-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 320 | Generic 100G Multimode | $150.00 | 19,661 | 12.80 | 0.80 | $2,949,120.00 | $1,920.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Corning | — | Device Level | — | — | — | — | Trainium1 | Backend | AWS-Trainium1-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 321 | Generic 100G Multimode | $150.00 | 4,915 | 3.20 | 0.20 | $737,280.00 | $480.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | Trainium1 | Backend | AWS-Trainium1-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 322 | Generic 100G SR4 QSFP28 | $49.50 | 12,288 | 8.00 | 0.50 | $608,224.97 | $395.98 | 3 W | 36,864 W | 24 W | Transceiver | Amazon | Coherent | — | Device Level | — | 28G | Ethernet | Fully Retimed | Trainium1 | Backend | AWS-Trainium1-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 323 | Generic 100G SR4 QSFP28 | $49.50 | 12,288 | 8.00 | 0.50 | $608,224.97 | $395.98 | 3 W | 36,864 W | 24 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 28G | Ethernet | Fully Retimed | Trainium1 | Backend | AWS-Trainium1-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 324 | Generic 100G SR4 QSFP28 | $49.50 | 9,830 | 6.40 | 0.40 | $486,579.98 | $316.78 | 3 W | 29,491 W | 19 W | Transceiver | Amazon | Innolight | — | Device Level | — | 28G | Ethernet | Fully Retimed | Trainium1 | Backend | AWS-Trainium1-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 325 | Generic 100G SR4 QSFP28 | $49.50 | 14,746 | 9.60 | 0.60 | $729,869.97 | $475.18 | 3 W | 44,237 W | 29 W | Transceiver | Amazon | Others | — | Device Level | — | 28G | Ethernet | Fully Retimed | Trainium1 | Backend | AWS-Trainium1-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 326 | WhiteBox Tomahawk 2 6.4T | $3,072.57 | 365 | 0.24 | 0.01 | $1,120,873.88 | $729.74 | 250 W | 91,200 W | 59 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium1 | Backend | AWS-Trainium1-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 327 | WhiteBox Tomahawk 2 6.4T | $3,072.57 | 19 | 0.01 | 0.00 | $58,993.36 | $38.41 | 250 W | 4,800 W | 3 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium1 | Backend | AWS-Trainium1-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 328 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 29 | 0.02 | 0.00 | $144,000.00 | $93.75 | 450 W | 12,960 W | 8 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium1 | Backend | AWS-Trainium1-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 329 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 259 | 0.17 | 0.01 | $1,296,000.00 | $843.75 | 450 W | 116,640 W | 76 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium1 | Backend | AWS-Trainium1-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 330 | EFAv2 Nitro-v4 100G NIC | $150.00 | 24,576 | 16.00 | 1.00 | $3,686,400.00 | $2,400.00 | 19 W | 466,944 W | 304 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | Trainium1n | Backend | AWS-Trainium1n-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 331 | Generic 100G AEC | $70.00 | 22,118 | 14.40 | 0.90 | $1,548,288.00 | $1,008.00 | 8 W | 176,947 W | 115 W | AEC | Amazon | Credo | — | Device Level | — | — | — | — | Trainium1n | Backend | AWS-Trainium1n-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 332 | Generic 100G AEC | $70.00 | 2,458 | 1.60 | 0.10 | $172,032.00 | $112.00 | 8 W | 19,661 W | 13 W | AEC | Amazon | Others | — | Device Level | — | — | — | — | Trainium1n | Backend | AWS-Trainium1n-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 333 | Generic 100G Multimode | $150.00 | 39,322 | 25.60 | 1.60 | $5,898,240.00 | $3,840.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Corning | — | Device Level | — | — | — | — | Trainium1n | Backend | AWS-Trainium1n-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 334 | Generic 100G Multimode | $150.00 | 9,830 | 6.40 | 0.40 | $1,474,560.00 | $960.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | Trainium1n | Backend | AWS-Trainium1n-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 335 | Generic 100G SR4 QSFP28 | $49.50 | 24,576 | 16.00 | 1.00 | $1,216,449.95 | $791.96 | 3 W | 73,728 W | 48 W | Transceiver | Amazon | Coherent | — | Device Level | — | 28G | Ethernet | Fully Retimed | Trainium1n | Backend | AWS-Trainium1n-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 336 | Generic 100G SR4 QSFP28 | $49.50 | 24,576 | 16.00 | 1.00 | $1,216,449.95 | $791.96 | 3 W | 73,728 W | 48 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 28G | Ethernet | Fully Retimed | Trainium1n | Backend | AWS-Trainium1n-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 337 | Generic 100G SR4 QSFP28 | $49.50 | 19,661 | 12.80 | 0.80 | $973,159.96 | $633.57 | 3 W | 58,982 W | 38 W | Transceiver | Amazon | Innolight | — | Device Level | — | 28G | Ethernet | Fully Retimed | Trainium1n | Backend | AWS-Trainium1n-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 338 | Generic 100G SR4 QSFP28 | $49.50 | 29,491 | 19.20 | 1.20 | $1,459,739.93 | $950.35 | 3 W | 88,474 W | 58 W | Transceiver | Amazon | Others | — | Device Level | — | 28G | Ethernet | Fully Retimed | Trainium1n | Backend | AWS-Trainium1n-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 339 | WhiteBox Tomahawk 2 6.4T | $3,072.57 | 730 | 0.48 | 0.03 | $2,241,747.76 | $1,459.47 | 250 W | 182,400 W | 119 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium1n | Backend | AWS-Trainium1n-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 340 | WhiteBox Tomahawk 2 6.4T | $3,072.57 | 38 | 0.03 | 0.00 | $117,986.72 | $76.81 | 250 W | 9,600 W | 6 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium1n | Backend | AWS-Trainium1n-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 341 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 58 | 0.04 | 0.00 | $288,000.00 | $187.50 | 450 W | 25,920 W | 17 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium1n | Backend | AWS-Trainium1n-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 342 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 518 | 0.34 | 0.02 | $2,592,000.00 | $1,687.50 | 450 W | 233,280 W | 152 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium1n | Backend | AWS-Trainium1n-Default | 23,520 | 18,643 | 33,949 | 44,752 | 37,653 | 53,859 | 73,333 | 63,333 | 46,667 | 2,351 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 343 | 112Gb/s SkewClear EXD Cable | $1.00 | 16,773,120 | 18,432.00 | 128.00 | $16,773,120.00 | $18,432.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | Trainium4 | Scale-Up | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,250 | 228,000 | 456,000 | 970,000 | 1,027,000 | 1,065,000 | 700,000 | 190,000 | 77,000 | — | — | — |
| 344 | Aries PCIe 7.0 x16 Retimer | $54.69 | — | — | — | — | — | 11 W | — | — | Retimer | Amazon | Astera | — | L1 Abstraction | — | — | — | — | Trainium4 | Compute Tray | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,250 | 228,000 | 456,000 | 970,000 | 1,027,000 | 1,065,000 | 700,000 | 190,000 | 77,000 | — | — | — |
| 345 | Aries PG6032 16L/32L Gearbox | $20.00 | — | — | — | — | — | 3 W | — | — | Gearbox | Amazon | Astera | — | L1 Abstraction | — | — | — | — | Trainium4 | Compute Tray | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,250 | 228,000 | 456,000 | 970,000 | 1,027,000 | 1,065,000 | 700,000 | 190,000 | 77,000 | — | — | — |
| 346 | Astera Labs Scorpio-P 32-Lane PCIe Gen 6.0 | $70.00 | — | — | — | — | — | 80 W | — | — | Scale-Up Switch | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium4 | Compute Tray | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,250 | 228,000 | 456,000 | 970,000 | 1,027,000 | 1,065,000 | 700,000 | 190,000 | 77,000 | — | — | — |
| 347 | Astera Labs UALink 57.6T Switch | $7,000.00 | 58,240 | 64.00 | 0.44 | $407,680,000.00 | $448,000.00 | 650 W | 37,856,000 W | 41,600 W | Scale-Up Switch | Amazon | Astera | — | Device Level | — | — | UALink | — | Trainium4 | Scale-Up | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,250 | 228,000 | 456,000 | 970,000 | 1,027,000 | 1,065,000 | 700,000 | 190,000 | 77,000 | — | — | — |
| 348 | Generic 800G AEC | $350.00 | 32,760 | 36.00 | 0.25 | $11,466,000.00 | $12,600.00 | 22 W | 733,824 W | 806 W | AEC | Amazon | Astera | — | Device Level | — | — | — | — | Trainium4 | Backend | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,250 | 228,000 | 456,000 | 970,000 | 1,027,000 | 1,065,000 | 700,000 | 190,000 | 77,000 | — | — | — |
| 349 | Generic 800G AEC | $350.00 | 65,520 | 72.00 | 0.50 | $22,932,000.00 | $25,200.00 | 22 W | 1,467,648 W | 1,613 W | AEC | Amazon | Credo | — | Device Level | — | — | — | — | Trainium4 | Backend | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,250 | 228,000 | 456,000 | 970,000 | 1,027,000 | 1,065,000 | 700,000 | 190,000 | 77,000 | — | — | — |
| 350 | Generic 800G AEC | $350.00 | 32,760 | 36.00 | 0.25 | $11,466,000.00 | $12,600.00 | 22 W | 733,824 W | 806 W | AEC | Amazon | Marvell | — | Device Level | — | — | — | — | Trainium4 | Backend | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,250 | 228,000 | 456,000 | 970,000 | 1,027,000 | 1,065,000 | 700,000 | 190,000 | 77,000 | — | — | — |
| 351 | Generic 800G DR8 | $500.00 | 52,416 | 57.60 | 0.40 | $26,208,000.00 | $28,800.00 | 16 W | 838,656 W | 922 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium4 | Backend | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,250 | 228,000 | 456,000 | 970,000 | 1,027,000 | 1,065,000 | 700,000 | 190,000 | 77,000 | — | — | — |
| 352 | Generic 800G DR8 | $500.00 | 209,664 | 230.40 | 1.60 | $104,832,000.00 | $115,200.00 | 16 W | 3,354,624 W | 3,686 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium4 | Backend | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,250 | 228,000 | 456,000 | 970,000 | 1,027,000 | 1,065,000 | 700,000 | 190,000 | 77,000 | — | — | — |
| 353 | Generic 800G DR8 | $500.00 | 262,080 | 288.00 | 2.00 | $131,040,000.00 | $144,000.00 | 16 W | 4,193,280 W | 4,608 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium4 | Backend | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,250 | 228,000 | 456,000 | 970,000 | 1,027,000 | 1,065,000 | 700,000 | 190,000 | 77,000 | — | — | — |
| 354 | Generic 800G Single Mode | $180.00 | 262,080 | 288.00 | 2.00 | $47,174,400.00 | $51,840.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | Trainium4 | Backend | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,250 | 228,000 | 456,000 | 970,000 | 1,027,000 | 1,065,000 | 700,000 | 190,000 | 77,000 | — | — | — |
| 355 | Nitro-v7 800G NIC | $900.00 | 131,040 | 4.00 | 1.00 | $117,936,000.00 | $3,600.00 | 75 W | 9,828,000 W | 300 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | Trainium4 | Backend | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,250 | 228,000 | 456,000 | 970,000 | 1,027,000 | 1,065,000 | 700,000 | 190,000 | 77,000 | — | — | — |
| 356 | Paladin HD2 224Gb/s 144 DP (Female) | $72.00 | 247,520 | 272.00 | 1.89 | $17,821,440.00 | $19,584.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | Trainium4 | Scale-Up | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,250 | 228,000 | 456,000 | 970,000 | 1,027,000 | 1,065,000 | 700,000 | 190,000 | 77,000 | — | — | — |
| 357 | Paladin HD2 224Gb/s 144 DP (Male) | $144.00 | 247,520 | 272.00 | 1.89 | $35,642,880.00 | $39,168.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | Trainium4 | Scale-Up | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,250 | 228,000 | 456,000 | 970,000 | 1,027,000 | 1,065,000 | 700,000 | 190,000 | 77,000 | — | — | — |
| 358 | Teton4 Backplane Chassis | $8,500.80 | 1,820 | 2.00 | 0.01 | $15,471,456.00 | $17,001.60 | 0 W | 0 W | 0 W | Backplane | Amazon | Others | — | Device Level | — | — | — | — | Trainium4 | Scale-Up | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,250 | 228,000 | 456,000 | 970,000 | 1,027,000 | 1,065,000 | 700,000 | 190,000 | 77,000 | — | — | — |
| 359 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 512 | 0.56 | 0.00 | $9,981,562.50 | $10,968.75 | 1,200 W | 614,250 W | 675 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium4 | Backend | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,250 | 228,000 | 456,000 | 970,000 | 1,027,000 | 1,065,000 | 700,000 | 190,000 | 77,000 | — | — | — |
| 360 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 9,726 | 10.69 | 0.07 | $189,649,687.50 | $208,406.25 | 1,200 W | 11,670,750 W | 12,825 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium4 | Backend | AWS-Trn4 EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,250 | 228,000 | 456,000 | 970,000 | 1,027,000 | 1,065,000 | 700,000 | 190,000 | 77,000 | — | — | — |
| 361 | Generic 1.6T DR8 (SiPho) | $810.00 | 78,643 | 43.20 | 0.60 | $63,700,992.00 | $34,992.00 | 22 W | 1,730,150 W | 950 W | Transceiver | Amazon | Coherent | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Backend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 362 | Generic 1.6T DR8 (SiPho) | $810.00 | 117,965 | 64.80 | 0.90 | $95,551,488.00 | $52,488.00 | 22 W | 2,595,226 W | 1,426 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Backend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 363 | Generic 1.6T DR8 (SiPho) | $810.00 | 196,608 | 108.00 | 1.50 | $159,252,480.00 | $87,480.00 | 22 W | 4,325,376 W | 2,376 W | Transceiver | Amazon | Innolight | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Backend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 364 | Generic 1.6T DR8 (SiPho) | $810.00 | 15,223 | 8.36 | 0.12 | $12,330,481.37 | $6,773.34 | 22 W | 334,902 W | 184 W | Transceiver | Amazon | Coherent | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 365 | Generic 1.6T DR8 (SiPho) | $810.00 | 22,834 | 12.54 | 0.17 | $18,495,722.06 | $10,160.00 | 22 W | 502,353 W | 276 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 366 | Generic 1.6T DR8 (SiPho) | $810.00 | 38,057 | 20.91 | 0.29 | $30,826,203.43 | $16,933.34 | 22 W | 837,255 W | 460 W | Transceiver | Amazon | Innolight | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 367 | Generic 200G Multimode | $150.00 | 14,967 | 8.22 | 0.11 | $2,244,998.10 | $1,233.21 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 368 | Generic 200G SR4 | $130.00 | 3,360 | 1.85 | 0.03 | $436,802.64 | $239.94 | 5 W | 16,800 W | 9 W | Transceiver | Amazon | AAOI | — | Device Level | — | 56G | Ethernet | Fully Retimed | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 369 | Generic 200G SR4 | $130.00 | 3,360 | 1.85 | 0.03 | $436,802.64 | $239.94 | 5 W | 16,800 W | 9 W | Transceiver | Amazon | Coherent | — | Device Level | — | 56G | Ethernet | Fully Retimed | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 370 | Generic 200G SR4 | $130.00 | 18,480 | 10.15 | 0.14 | $2,402,414.53 | $1,319.69 | 5 W | 92,401 W | 51 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 56G | Ethernet | Fully Retimed | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 371 | Generic 200G SR4 | $130.00 | 8,400 | 4.61 | 0.06 | $1,092,006.60 | $599.86 | 5 W | 42,000 W | 23 W | Transceiver | Amazon | Innolight | — | Device Level | — | 56G | Ethernet | Fully Retimed | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 372 | Generic 400G Multimode | $150.00 | 533 | 0.29 | 0.00 | $79,969.52 | $43.93 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 373 | Generic 800G DR4 | $650.00 | 26,214 | 14.40 | 0.20 | $17,039,360.00 | $9,360.00 | 17 W | 445,645 W | 245 W | Transceiver | Amazon | AAOI | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Backend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 374 | Generic 800G DR4 | $650.00 | 104,858 | 57.60 | 0.80 | $68,157,440.00 | $37,440.00 | 17 W | 1,782,579 W | 979 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Backend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 375 | Generic 800G DR4 | $650.00 | 131,072 | 72.00 | 1.00 | $85,196,800.00 | $46,800.00 | 17 W | 2,228,224 W | 1,224 W | Transceiver | Amazon | Innolight | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Backend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 376 | Generic 800G DR4 | $650.00 | 7,572 | 4.16 | 0.06 | $4,921,636.57 | $2,703.54 | 17 W | 128,720 W | 71 W | Transceiver | Amazon | AAOI | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 377 | Generic 800G DR4 | $650.00 | 30,287 | 16.64 | 0.23 | $19,686,546.29 | $10,814.14 | 17 W | 514,879 W | 283 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 378 | Generic 800G DR4 | $650.00 | 37,859 | 20.80 | 0.29 | $24,608,182.86 | $13,517.68 | 17 W | 643,599 W | 354 W | Transceiver | Amazon | Innolight | — | Device Level | — | 224G | Ethernet | Fully Retimed | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 379 | Generic 800G DR4 Single Mode | $130.00 | 524,288 | 288.00 | 4.00 | $68,157,440.00 | $37,440.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | VR200 | Backend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 380 | Generic 800G Multimode | $210.00 | 104,168 | 57.22 | 0.79 | $21,875,370.67 | $12,016.50 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 381 | Nitro-v7 800G NIC | $900.00 | 262,144 | 8.00 | 2.00 | $235,929,600.00 | $7,200.00 | 75 W | 19,660,800 W | 600 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | VR200 | Backend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 382 | NV 224Gb/s SkewClear EXD Gen 2 Bidi Cable | $4.00 | 9,437,184 | 5,184.00 | 72.00 | $37,748,736.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Scale-Up | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 383 | Nvidia NVSwitch 6.0 (NVLink 6) | $4,000.00 | 65,536 | 36.00 | 0.50 | $262,144,000.00 | $144,000.00 | 650 W | 42,598,400 W | 23,400 W | Scale-Up Switch | Amazon | Nvidia | — | Device Level | — | — | NVLink | — | VR200 | Scale-Up | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 384 | NVL Spine Chassis (NvLink 6) | $225.00 | 3,641 | 2.00 | 0.03 | $819,200.00 | $450.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Unassigned | Others | Device Level | — | — | NVLink | — | VR200 | Scale-Up | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 385 | NV Paladin Board to Board 32 Pin 4p8c (Female) | $32.00 | 131,072 | 72.00 | 1.00 | $4,194,304.00 | $2,304.00 | 0 W | 0 W | 0 W | Midplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Compute Tray | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 386 | NV Paladin Board to Board 32 Pin 4p8c (Male) | $64.00 | 131,072 | 72.00 | 1.00 | $8,388,608.00 | $4,608.00 | 0 W | 0 W | 0 W | Midplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Compute Tray | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 387 | NV Paladin Board to Board 64 Pin 4p16c (Female) | $64.00 | 524,288 | 288.00 | 4.00 | $33,554,432.00 | $18,432.00 | 0 W | 0 W | 0 W | Midplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Compute Tray | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 388 | NV Paladin Board to Board 64 Pin 4p16c (Male) | $128.00 | 524,288 | 288.00 | 4.00 | $67,108,864.00 | $36,864.00 | 0 W | 0 W | 0 W | Midplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Compute Tray | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 389 | NV Paladin HD2 224Gb/s 144 Bidi (Female) | $288.00 | 65,536 | 36.00 | 0.50 | $18,874,368.00 | $10,368.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Scale-Up | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 390 | NV Paladin HD2 224Gb/s 144 Bidi (Male) | $576.00 | 65,536 | 36.00 | 0.50 | $37,748,736.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Scale-Up | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 391 | NV Paladin HD2 224Gb/s 72 Bidi (Female) | $144.00 | 9,437,184 | 5,184.00 | 72.00 | $1,358,954,496.00 | $746,496.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Scale-Up | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 392 | NV Paladin HD2 224Gb/s 72 Bidi (Male) | $288.00 | 131,072 | 72.00 | 1.00 | $37,748,736.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | VR200 | Scale-Up | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 393 | RJ45 Cables | $1.00 | 92,375 | 50.74 | 0.70 | $92,374.55 | $50.74 | 0 W | 0 W | 0 W | Cable | Amazon | Amphenol | — | Device Level | — | — | — | — | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 394 | WhiteBox Tomahawk 2 6.4T | $3,072.57 | 1,828 | 1.00 | 0.01 | $5,617,416.61 | $3,085.74 | 250 W | 457,062 W | 251 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 395 | WhiteBox Tomahawk 2 6.4T | $3,072.57 | 96 | 0.05 | 0.00 | $295,653.51 | $162.41 | 250 W | 24,056 W | 13 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 396 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 23 | 0.01 | 0.00 | $117,028.57 | $64.29 | 450 W | 10,533 W | 6 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 397 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 211 | 0.12 | 0.00 | $1,053,257.14 | $578.57 | 450 W | 94,793 W | 52 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 398 | WhiteBox Tomahawk 4 25.6T | $13,500.00 | 6 | 0.00 | 0.00 | $83,382.85 | $45.80 | 850 W | 5,250 W | 3 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 399 | WhiteBox Tomahawk 4 25.6T | $13,500.00 | 0 | 0.00 | 0.00 | $4,388.57 | $2.41 | 850 W | 276 W | 0 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | VR200 | Frontend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |
| 400 | WhiteBox Tomahawk 6 102.4T | $40,000.00 | 2,765 | 1.52 | 0.02 | $110,592,000.00 | $60,750.00 | 1,697 W | 4,692,021 W | 2,577 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | VR200 | Backend | AWS-VR200 NVL144-EFA-WB-8P-2L | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | 14,400 | 86,400 | 120,000 | 150,000 | 150,000 | 40,158 | 17,100 | 8,100 | — | — | — | — | — | — | — | — | — |