| # | Item | Unit Cost | Quantity (per Cluster) | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name | 1Q23 | 2Q23 | 3Q23 | 4Q23 | 1Q24 | 2Q24 | 3Q24 | 4Q24 | 1Q25 | 2Q25 | 3Q25 | 4Q25 | 1Q26 | 2Q26 | 3Q26 | 4Q26 | 1Q27 | 2Q27 | 3Q27 | 4Q27 | 1Q28 | 2Q28 | 3Q28 | 4Q28 | 1Q29 | 2Q29 | 3Q29 | 4Q29 | 1Q30 | 2Q30 | 3Q30 | 4Q30 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 201 | Generic 400G Single Mode | $130.00 | 262,144 | 16.00 | 2.00 | $34,078,720.00 | $2,080.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | H100 | Backend | AWS-P5en-H100 NVL8-EFA-WB | 4,120 | 3,952 | 11,816 | 11,232 | 53,808 | 81,136 | 99,912 | 105,384 | 48,544 | 30,000 | 20,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 202 | Generic 400G Y Cable AEC | $270.00 | 43,691 | 2.67 | 0.33 | $11,796,480.00 | $720.00 | 12 W | 524,288 W | 32 W | AEC | Amazon | Astera | — | Device Level | — | — | — | — | H100 | Backend | AWS-P5en-H100 NVL8-EFA-WB | 4,120 | 3,952 | 11,816 | 11,232 | 53,808 | 81,136 | 99,912 | 105,384 | 48,544 | 30,000 | 20,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 203 | Generic 400G Y Cable AEC | $270.00 | 43,691 | 2.67 | 0.33 | $11,796,480.00 | $720.00 | 12 W | 524,288 W | 32 W | AEC | Amazon | Credo | — | Device Level | — | — | — | — | H100 | Backend | AWS-P5en-H100 NVL8-EFA-WB | 4,120 | 3,952 | 11,816 | 11,232 | 53,808 | 81,136 | 99,912 | 105,384 | 48,544 | 30,000 | 20,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 204 | Generic 400G Y Cable AEC | $270.00 | 43,691 | 2.67 | 0.33 | $11,796,480.00 | $720.00 | 12 W | 524,288 W | 32 W | AEC | Amazon | Marvell | — | Device Level | — | — | — | — | H100 | Backend | AWS-P5en-H100 NVL8-EFA-WB | 4,120 | 3,952 | 11,816 | 11,232 | 53,808 | 81,136 | 99,912 | 105,384 | 48,544 | 30,000 | 20,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 205 | Generic PCIe Gen5 x16 2-meter DAC | $82.00 | 131,072 | 8.00 | 1.00 | $10,747,904.00 | $656.00 | 0 W | 0 W | 0 W | DAC | Amazon | Astera | — | Device Level | — | — | PCIe | — | H100 | Compute Tray | AWS-P5en-H100 NVL8-EFA-WB | 4,120 | 3,952 | 11,816 | 11,232 | 53,808 | 81,136 | 99,912 | 105,384 | 48,544 | 30,000 | 20,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 206 | Nvidia NVSwitch 3.0 (NVLink 4) | $1,200.00 | 65,536 | 4.00 | 0.50 | $78,643,200.00 | $4,800.00 | 407 W | 26,699,366 W | 1,630 W | Scale-Up Switch | Amazon | Nvidia | — | Device Level | — | — | NVLink | — | H100 | Scale-Up | AWS-P5en-H100 NVL8-EFA-WB | 4,120 | 3,952 | 11,816 | 11,232 | 53,808 | 81,136 | 99,912 | 105,384 | 48,544 | 30,000 | 20,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 207 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 2,048 | 0.13 | 0.02 | $10,240,000.00 | $625.00 | 450 W | 921,600 W | 56 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | H100 | Backend | AWS-P5en-H100 NVL8-EFA-WB | 4,120 | 3,952 | 11,816 | 11,232 | 53,808 | 81,136 | 99,912 | 105,384 | 48,544 | 30,000 | 20,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 208 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 18,432 | 1.13 | 0.14 | $92,160,000.00 | $5,625.00 | 450 W | 8,294,400 W | 506 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | H100 | Backend | AWS-P5en-H100 NVL8-EFA-WB | 4,120 | 3,952 | 11,816 | 11,232 | 53,808 | 81,136 | 99,912 | 105,384 | 48,544 | 30,000 | 20,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 209 | Broadcom PEX89144 Gen 5.0 144L | $664.62 | 65,536 | 4.00 | 0.50 | $43,556,233.87 | $2,658.46 | 240 W | 15,728,640 W | 960 W | Switch | Amazon | Broadcom | — | Device Level | — | — | — | — | B200 | Compute Tray | AWS-P6-B200 NVL8-EFA-WB | — | — | — | — | — | — | — | — | 37,136 | 40,688 | 46,752 | 16,808 | 7,000 | 3,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 210 | EFAv3 Nitro-v5 200G NIC | $300.00 | 262,144 | 16.00 | 2.00 | $78,643,200.00 | $4,800.00 | 38 W | 9,961,472 W | 608 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | B200 | Backend | AWS-P6-B200 NVL8-EFA-WB | — | — | — | — | — | — | — | — | 37,136 | 40,688 | 46,752 | 16,808 | 7,000 | 3,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 211 | Generic 400G DR4 | $260.00 | 13,107 | 0.80 | 0.10 | $3,407,872.00 | $208.00 | 10 W | 131,072 W | 8 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | B200 | Backend | AWS-P6-B200 NVL8-EFA-WB | — | — | — | — | — | — | — | — | 37,136 | 40,688 | 46,752 | 16,808 | 7,000 | 3,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 212 | Generic 400G DR4 | $260.00 | 19,661 | 1.20 | 0.15 | $5,111,808.00 | $312.00 | 10 W | 196,608 W | 12 W | Transceiver | Amazon | Coherent | — | Device Level | — | 112G | Ethernet | Fully Retimed | B200 | Backend | AWS-P6-B200 NVL8-EFA-WB | — | — | — | — | — | — | — | — | 37,136 | 40,688 | 46,752 | 16,808 | 7,000 | 3,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 213 | Generic 400G DR4 | $260.00 | 65,536 | 4.00 | 0.50 | $17,039,360.00 | $1,040.00 | 10 W | 655,360 W | 40 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | B200 | Backend | AWS-P6-B200 NVL8-EFA-WB | — | — | — | — | — | — | — | — | 37,136 | 40,688 | 46,752 | 16,808 | 7,000 | 3,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 214 | Generic 400G DR4 | $260.00 | 32,768 | 2.00 | 0.25 | $8,519,680.00 | $520.00 | 10 W | 327,680 W | 20 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | B200 | Backend | AWS-P6-B200 NVL8-EFA-WB | — | — | — | — | — | — | — | — | 37,136 | 40,688 | 46,752 | 16,808 | 7,000 | 3,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 215 | Generic 400G Single Mode | $130.00 | 262,144 | 16.00 | 2.00 | $34,078,720.00 | $2,080.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | B200 | Backend | AWS-P6-B200 NVL8-EFA-WB | — | — | — | — | — | — | — | — | 37,136 | 40,688 | 46,752 | 16,808 | 7,000 | 3,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 216 | Generic 400G Y Cable AEC | $270.00 | 43,691 | 2.67 | 0.33 | $11,796,480.00 | $720.00 | 12 W | 524,288 W | 32 W | AEC | Amazon | Astera | — | Device Level | — | — | — | — | B200 | Backend | AWS-P6-B200 NVL8-EFA-WB | — | — | — | — | — | — | — | — | 37,136 | 40,688 | 46,752 | 16,808 | 7,000 | 3,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 217 | Generic 400G Y Cable AEC | $270.00 | 43,691 | 2.67 | 0.33 | $11,796,480.00 | $720.00 | 12 W | 524,288 W | 32 W | AEC | Amazon | Credo | — | Device Level | — | — | — | — | B200 | Backend | AWS-P6-B200 NVL8-EFA-WB | — | — | — | — | — | — | — | — | 37,136 | 40,688 | 46,752 | 16,808 | 7,000 | 3,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 218 | Generic 400G Y Cable AEC | $270.00 | 43,691 | 2.67 | 0.33 | $11,796,480.00 | $720.00 | 12 W | 524,288 W | 32 W | AEC | Amazon | Marvell | — | Device Level | — | — | — | — | B200 | Backend | AWS-P6-B200 NVL8-EFA-WB | — | — | — | — | — | — | — | — | 37,136 | 40,688 | 46,752 | 16,808 | 7,000 | 3,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 219 | Generic 800G DR8 | $500.00 | 19,661 | 1.20 | 0.15 | $9,830,400.00 | $600.00 | 16 W | 314,573 W | 19 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | B200 | Backend | AWS-P6-B200 NVL8-EFA-WB | — | — | — | — | — | — | — | — | 37,136 | 40,688 | 46,752 | 16,808 | 7,000 | 3,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 220 | Generic 800G DR8 | $500.00 | 78,643 | 4.80 | 0.60 | $39,321,600.00 | $2,400.00 | 16 W | 1,258,291 W | 77 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | B200 | Backend | AWS-P6-B200 NVL8-EFA-WB | — | — | — | — | — | — | — | — | 37,136 | 40,688 | 46,752 | 16,808 | 7,000 | 3,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 221 | Generic 800G DR8 | $500.00 | 98,304 | 6.00 | 0.75 | $49,152,000.00 | $3,000.00 | 16 W | 1,572,864 W | 96 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | B200 | Backend | AWS-P6-B200 NVL8-EFA-WB | — | — | — | — | — | — | — | — | 37,136 | 40,688 | 46,752 | 16,808 | 7,000 | 3,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 222 | Generic PCIe Gen5 x16 2-meter DAC | $82.00 | 131,072 | 8.00 | 1.00 | $10,747,904.00 | $656.00 | 0 W | 0 W | 0 W | DAC | Amazon | Astera | — | Device Level | — | — | PCIe | — | B200 | Compute Tray | AWS-P6-B200 NVL8-EFA-WB | — | — | — | — | — | — | — | — | 37,136 | 40,688 | 46,752 | 16,808 | 7,000 | 3,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 223 | Nvidia NVSwitch 5.0 (NVLink 5) | $3,200.00 | 32,768 | 2.00 | 0.25 | $104,857,600.00 | $6,400.00 | 407 W | 13,349,683 W | 815 W | Scale-Up Switch | Amazon | Nvidia | — | Device Level | — | — | NVLink | — | B200 | Scale-Up | AWS-P6-B200 NVL8-EFA-WB | — | — | — | — | — | — | — | — | 37,136 | 40,688 | 46,752 | 16,808 | 7,000 | 3,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 224 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 819 | 0.05 | 0.01 | $4,096,000.00 | $250.00 | 450 W | 368,640 W | 23 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | B200 | Backend | AWS-P6-B200 NVL8-EFA-WB | — | — | — | — | — | — | — | — | 37,136 | 40,688 | 46,752 | 16,808 | 7,000 | 3,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 225 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 7,373 | 0.45 | 0.06 | $36,864,000.00 | $2,250.00 | 450 W | 3,317,760 W | 203 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | B200 | Backend | AWS-P6-B200 NVL8-EFA-WB | — | — | — | — | — | — | — | — | 37,136 | 40,688 | 46,752 | 16,808 | 7,000 | 3,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 226 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 154 | 0.01 | 0.00 | $2,995,200.00 | $182.81 | 1,200 W | 184,320 W | 11 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | B200 | Backend | AWS-P6-B200 NVL8-EFA-WB | — | — | — | — | — | — | — | — | 37,136 | 40,688 | 46,752 | 16,808 | 7,000 | 3,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 227 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 2,918 | 0.18 | 0.02 | $56,908,800.00 | $3,473.44 | 1,200 W | 3,502,080 W | 214 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | B200 | Backend | AWS-P6-B200 NVL8-EFA-WB | — | — | — | — | — | — | — | — | 37,136 | 40,688 | 46,752 | 16,808 | 7,000 | 3,000 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 228 | Astera Labs Scorpio-P 64-Lane PCIe Gen 6.0 | $220.00 | 131,072 | 72.00 | 1.00 | $28,835,840.00 | $15,840.00 | 130 W | 17,039,360 W | 9,360 W | Scale-Up Switch | Amazon | Astera | — | Device Level | — | — | PCIe | — | B300 | Compute Tray | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 3,960 | 1,872 | 4,064 | 1,968 | 1,656 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 229 | ConnectX-8 NIC - 800G | $1,500.00 | 131,072 | 72.00 | 1.00 | $196,608,000.00 | $108,000.00 | 75 W | 9,830,400 W | 5,400 W | NIC | Amazon | Nvidia | — | Device Level | — | — | — | — | B300 | Compute Tray | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 3,960 | 1,872 | 4,064 | 1,968 | 1,656 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 230 | EFAv4 Nitro-v6 400G NIC | $480.00 | 262,144 | 16.00 | 2.00 | $125,829,120.00 | $7,680.00 | 50 W | 13,107,200 W | 800 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 3,960 | 1,872 | 4,064 | 1,968 | 1,656 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 231 | Generic 400G AEC | $250.00 | 87,381 | 48.00 | 0.67 | $21,845,333.33 | $12,000.00 | 12 W | 1,048,576 W | 576 W | AEC | Amazon | Astera | — | Device Level | — | — | — | — | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 3,960 | 1,872 | 4,064 | 1,968 | 1,656 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 232 | Generic 400G AEC | $250.00 | 87,381 | 48.00 | 0.67 | $21,845,333.33 | $12,000.00 | 12 W | 1,048,576 W | 576 W | AEC | Amazon | Credo | — | Device Level | — | — | — | — | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 3,960 | 1,872 | 4,064 | 1,968 | 1,656 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 233 | Generic 400G AEC | $250.00 | 87,381 | 48.00 | 0.67 | $21,845,333.33 | $12,000.00 | 12 W | 1,048,576 W | 576 W | AEC | Amazon | Marvell | — | Device Level | — | — | — | — | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 3,960 | 1,872 | 4,064 | 1,968 | 1,656 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 234 | Generic 400G DR4 | $260.00 | 26,214 | 14.40 | 0.20 | $6,815,744.00 | $3,744.00 | 10 W | 262,144 W | 144 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 3,960 | 1,872 | 4,064 | 1,968 | 1,656 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 235 | Generic 400G DR4 | $260.00 | 39,322 | 21.60 | 0.30 | $10,223,616.00 | $5,616.00 | 10 W | 393,216 W | 216 W | Transceiver | Amazon | Coherent | — | Device Level | — | 112G | Ethernet | Fully Retimed | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 3,960 | 1,872 | 4,064 | 1,968 | 1,656 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 236 | Generic 400G DR4 | $260.00 | 131,072 | 72.00 | 1.00 | $34,078,720.00 | $18,720.00 | 10 W | 1,310,720 W | 720 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 3,960 | 1,872 | 4,064 | 1,968 | 1,656 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 237 | Generic 400G DR4 | $260.00 | 65,536 | 36.00 | 0.50 | $17,039,360.00 | $9,360.00 | 10 W | 655,360 W | 360 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 3,960 | 1,872 | 4,064 | 1,968 | 1,656 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 238 | Generic 400G Single Mode | $130.00 | 524,288 | 288.00 | 4.00 | $68,157,440.00 | $37,440.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 3,960 | 1,872 | 4,064 | 1,968 | 1,656 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 239 | Generic 800G DR8 | $500.00 | 39,322 | 21.60 | 0.30 | $19,660,800.00 | $10,800.00 | 16 W | 629,146 W | 346 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 3,960 | 1,872 | 4,064 | 1,968 | 1,656 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 240 | Generic 800G DR8 | $500.00 | 157,286 | 86.40 | 1.20 | $78,643,200.00 | $43,200.00 | 16 W | 2,516,582 W | 1,382 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 3,960 | 1,872 | 4,064 | 1,968 | 1,656 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 241 | Generic 800G DR8 | $500.00 | 196,608 | 108.00 | 1.50 | $98,304,000.00 | $54,000.00 | 16 W | 3,145,728 W | 1,728 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 3,960 | 1,872 | 4,064 | 1,968 | 1,656 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 242 | Generic PCIe Gen6 x16 2-meter DAC | $85.00 | 131,072 | 72.00 | 1.00 | $11,141,120.00 | $6,120.00 | 0 W | 0 W | 0 W | DAC | Amazon | Astera | — | Device Level | — | — | PCIe | — | B300 | Compute Tray | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 3,960 | 1,872 | 4,064 | 1,968 | 1,656 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 243 | Nvidia NVSwitch 5.0 (NVLink 5) | $3,200.00 | 32,768 | 18.00 | 0.25 | $104,857,600.00 | $57,600.00 | 407 W | 13,349,683 W | 7,333 W | Scale-Up Switch | Amazon | Nvidia | — | Device Level | — | — | NVLink | — | B300 | Scale-Up | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 3,960 | 1,872 | 4,064 | 1,968 | 1,656 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 244 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 1,638 | 0.90 | 0.01 | $8,192,000.00 | $4,500.00 | 450 W | 737,280 W | 405 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 3,960 | 1,872 | 4,064 | 1,968 | 1,656 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 245 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 14,746 | 8.10 | 0.11 | $73,728,000.00 | $40,500.00 | 450 W | 6,635,520 W | 3,645 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 3,960 | 1,872 | 4,064 | 1,968 | 1,656 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 246 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 307 | 0.17 | 0.00 | $5,990,400.00 | $3,290.63 | 1,200 W | 368,640 W | 203 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 3,960 | 1,872 | 4,064 | 1,968 | 1,656 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 247 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 5,837 | 3.21 | 0.04 | $113,817,600.00 | $62,521.88 | 1,200 W | 7,004,160 W | 3,848 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | B300 | Backend | AWS-P6-B300 NVL8-EFA-WB | — | — | — | — | — | — | — | — | — | — | 3,960 | 1,872 | 4,064 | 1,968 | 1,656 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 248 | 112Gb/s TE Connectivity Madison Cable (1DP per cable) | $1.00 | 12,582,912 | 6,144.00 | 96.00 | $12,582,912.00 | $6,144.00 | — | — | — | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium2 | Scale-Up | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 5,000 | 25,000 | 145,000 | 205,000 | 375,000 | 443,690 | 269,630 | 315,000 | 19,020 | — | 42,370 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 249 | 200G EFAv3 QSFP56 Flat Top DAC | $15.00 | 14,746 | 7.20 | 0.11 | $221,184.00 | $108.00 | 0 W | 0 W | 0 W | DAC | Amazon | Amphenol | — | Device Level | — | — | — | — | Trainium2 | Compute Tray | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 5,000 | 25,000 | 145,000 | 205,000 | 375,000 | 443,690 | 269,630 | 315,000 | 19,020 | — | 42,370 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 250 | 200G EFAv3 QSFP56 Flat Top DAC | $15.00 | 11,469 | 5.60 | 0.09 | $172,032.00 | $84.00 | 0 W | 0 W | 0 W | DAC | Amazon | Molex | — | Device Level | — | — | — | — | Trainium2 | Compute Tray | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 5,000 | 25,000 | 145,000 | 205,000 | 375,000 | 443,690 | 269,630 | 315,000 | 19,020 | — | 42,370 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 251 | 200G EFAv3 QSFP56 Flat Top DAC | $15.00 | 6,554 | 3.20 | 0.05 | $98,304.00 | $48.00 | 0 W | 0 W | 0 W | DAC | Amazon | TE | — | Device Level | — | — | — | — | Trainium2 | Compute Tray | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 5,000 | 25,000 | 145,000 | 205,000 | 375,000 | 443,690 | 269,630 | 315,000 | 19,020 | — | 42,370 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 252 | Aries PCIe 5.0 x16 Retimer | $35.00 | 262,144 | 128.00 | 2.00 | $9,175,040.00 | $4,480.00 | 9 W | 2,359,296 W | 1,152 W | Retimer | Amazon | Astera | — | L1 Abstraction | — | — | — | — | Trainium2 | Compute Tray | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 5,000 | 25,000 | 145,000 | 205,000 | 375,000 | 443,690 | 269,630 | 315,000 | 19,020 | — | 42,370 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 253 | EFAv3 Nitro-v5 200G NIC | $300.00 | 139,264 | 17.00 | 1.06 | $41,779,200.00 | $5,100.00 | 38 W | 5,292,032 W | 646 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 5,000 | 25,000 | 145,000 | 205,000 | 375,000 | 443,690 | 269,630 | 315,000 | 19,020 | — | 42,370 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 254 | Generic 400G DR4 | $260.00 | 6,554 | 3.20 | 0.05 | $1,703,936.00 | $832.00 | 10 W | 65,536 W | 32 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 5,000 | 25,000 | 145,000 | 205,000 | 375,000 | 443,690 | 269,630 | 315,000 | 19,020 | — | 42,370 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 255 | Generic 400G DR4 | $260.00 | 9,830 | 4.80 | 0.08 | $2,555,904.00 | $1,248.00 | 10 W | 98,304 W | 48 W | Transceiver | Amazon | Coherent | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 5,000 | 25,000 | 145,000 | 205,000 | 375,000 | 443,690 | 269,630 | 315,000 | 19,020 | — | 42,370 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 256 | Generic 400G DR4 | $260.00 | 32,768 | 16.00 | 0.25 | $8,519,680.00 | $4,160.00 | 10 W | 327,680 W | 160 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 5,000 | 25,000 | 145,000 | 205,000 | 375,000 | 443,690 | 269,630 | 315,000 | 19,020 | — | 42,370 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 257 | Generic 400G DR4 | $260.00 | 16,384 | 8.00 | 0.13 | $4,259,840.00 | $2,080.00 | 10 W | 163,840 W | 80 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 5,000 | 25,000 | 145,000 | 205,000 | 375,000 | 443,690 | 269,630 | 315,000 | 19,020 | — | 42,370 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 258 | Generic 400G Single Mode | $130.00 | 131,072 | 64.00 | 1.00 | $17,039,360.00 | $8,320.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 5,000 | 25,000 | 145,000 | 205,000 | 375,000 | 443,690 | 269,630 | 315,000 | 19,020 | — | 42,370 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 259 | Generic 400G Y Cable AEC | $270.00 | 10,445 | 5.10 | 0.08 | $2,820,096.00 | $1,377.00 | 12 W | 125,338 W | 61 W | AEC | Amazon | Astera | — | Device Level | — | — | — | — | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 5,000 | 25,000 | 145,000 | 205,000 | 375,000 | 443,690 | 269,630 | 315,000 | 19,020 | — | 42,370 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 260 | Generic 400G Y Cable AEC | $270.00 | 59,187 | 28.90 | 0.45 | $15,980,544.00 | $7,803.00 | 12 W | 710,246 W | 347 W | AEC | Amazon | Credo | — | Device Level | — | — | — | — | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 5,000 | 25,000 | 145,000 | 205,000 | 375,000 | 443,690 | 269,630 | 315,000 | 19,020 | — | 42,370 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 261 | Generic 800G DR8 | $500.00 | 19,661 | 9.60 | 0.15 | $9,830,400.00 | $4,800.00 | 16 W | 314,573 W | 154 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 5,000 | 25,000 | 145,000 | 205,000 | 375,000 | 443,690 | 269,630 | 315,000 | 19,020 | — | 42,370 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 262 | Generic 800G DR8 | $500.00 | 78,643 | 38.40 | 0.60 | $39,321,600.00 | $19,200.00 | 16 W | 1,258,291 W | 614 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 5,000 | 25,000 | 145,000 | 205,000 | 375,000 | 443,690 | 269,630 | 315,000 | 19,020 | — | 42,370 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 263 | Generic 800G DR8 | $500.00 | 98,304 | 48.00 | 0.75 | $49,152,000.00 | $24,000.00 | 16 W | 1,572,864 W | 768 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 5,000 | 25,000 | 145,000 | 205,000 | 375,000 | 443,690 | 269,630 | 315,000 | 19,020 | — | 42,370 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 264 | Generic PCIe Gen5 x16 (32Gb/s uni-di) 2-meter AEC | $350.00 | 131,072 | 64.00 | 1.00 | $45,875,200.00 | $22,400.00 | 3 W | 393,216 W | 192 W | AEC | Amazon | Astera | — | Device Level | — | — | PCIe | — | Trainium2 | Scale-Up | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 5,000 | 25,000 | 145,000 | 205,000 | 375,000 | 443,690 | 269,630 | 315,000 | 19,020 | — | 42,370 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 265 | Strada Whisper 112Gb/s 64 DP Absolute Connector (Female) | $14.08 | 393,216 | 192.00 | 3.00 | $5,536,481.28 | $2,703.36 | 0 W | 0 W | 0 W | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium2 | Scale-Up | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 5,000 | 25,000 | 145,000 | 205,000 | 375,000 | 443,690 | 269,630 | 315,000 | 19,020 | — | 42,370 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 266 | Strada Whisper 112Gb/s 64 DP Absolute Connector (Male) | $42.24 | 393,216 | 192.00 | 3.00 | $16,609,443.84 | $8,110.08 | 0 W | 0 W | 0 W | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium2 | Scale-Up | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 5,000 | 25,000 | 145,000 | 205,000 | 375,000 | 443,690 | 269,630 | 315,000 | 19,020 | — | 42,370 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 267 | Teton2 Backplane Chassis | $7,728.00 | 8,192 | 4.00 | 0.06 | $63,307,776.00 | $30,912.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Others | — | Device Level | — | — | — | — | Trainium2 | Scale-Up | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 5,000 | 25,000 | 145,000 | 205,000 | 375,000 | 443,690 | 269,630 | 315,000 | 19,020 | — | 42,370 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 268 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 1,024 | 0.50 | 0.01 | $5,120,000.00 | $2,500.00 | 450 W | 460,800 W | 225 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 5,000 | 25,000 | 145,000 | 205,000 | 375,000 | 443,690 | 269,630 | 315,000 | 19,020 | — | 42,370 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 269 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 9,216 | 4.50 | 0.07 | $46,080,000.00 | $22,500.00 | 450 W | 4,147,200 W | 2,025 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium2 | Backend | AWS-Teton2 PD Ultra-Nv5-EFA-WB | — | — | — | — | — | — | — | — | 5,000 | 25,000 | 145,000 | 205,000 | 375,000 | 443,690 | 269,630 | 315,000 | 19,020 | — | 42,370 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 270 | 112Gb/s TE Connectivity Madison Cable (1DP per cable) | $1.00 | 12,582,912 | 6,144.00 | 96.00 | $12,582,912.00 | $6,144.00 | — | — | — | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 271 | 200G EFAv4 QSFP56 Flat Top DAC | $15.00 | 14,746 | 7.20 | 0.11 | $221,184.00 | $108.00 | 0 W | 0 W | 0 W | DAC | Amazon | Amphenol | — | Device Level | — | — | — | — | Trainium3 | Compute Tray | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 272 | 200G EFAv4 QSFP56 Flat Top DAC | $15.00 | 11,469 | 5.60 | 0.09 | $172,032.00 | $84.00 | 0 W | 0 W | 0 W | DAC | Amazon | Molex | — | Device Level | — | — | — | — | Trainium3 | Compute Tray | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 273 | 200G EFAv4 QSFP56 Flat Top DAC | $15.00 | 6,554 | 3.20 | 0.05 | $98,304.00 | $48.00 | 0 W | 0 W | 0 W | DAC | Amazon | TE | — | Device Level | — | — | — | — | Trainium3 | Compute Tray | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 274 | Aries PCIe 6.0 x16 Retimer | $43.75 | 131,072 | 64.00 | 1.00 | $5,734,400.00 | $2,800.00 | 11 W | 1,441,792 W | 704 W | Retimer | Amazon | Astera | — | L1 Abstraction | — | — | — | — | Trainium3 | Compute Tray | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 275 | EFAv4 Nitro-v6 400G NIC | $480.00 | 139,264 | 17.00 | 1.06 | $66,846,720.00 | $8,160.00 | 50 W | 6,963,200 W | 850 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 276 | Generic 400G AEC | $250.00 | 33,792 | 16.50 | 0.26 | $8,448,000.00 | $4,125.00 | 12 W | 405,504 W | 198 W | AEC | Amazon | Astera | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 277 | Generic 400G AEC | $250.00 | 74,342 | 36.30 | 0.57 | $18,585,600.00 | $9,075.00 | 12 W | 892,109 W | 436 W | AEC | Amazon | Credo | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 278 | Generic 400G AEC | $250.00 | 27,034 | 13.20 | 0.21 | $6,758,400.00 | $3,300.00 | 12 W | 324,403 W | 158 W | AEC | Amazon | Marvell | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 279 | Generic 400G DR4 | $260.00 | 13,517 | 6.60 | 0.10 | $3,514,368.00 | $1,716.00 | 10 W | 135,168 W | 66 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 280 | Generic 400G DR4 | $260.00 | 20,275 | 9.90 | 0.15 | $5,271,552.00 | $2,574.00 | 10 W | 202,752 W | 99 W | Transceiver | Amazon | Coherent | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 281 | Generic 400G DR4 | $260.00 | 67,584 | 33.00 | 0.52 | $17,571,840.00 | $8,580.00 | 10 W | 675,840 W | 330 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 282 | Generic 400G DR4 | $260.00 | 33,792 | 16.50 | 0.26 | $8,785,920.00 | $4,290.00 | 10 W | 337,920 W | 165 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 283 | Generic 400G Single Mode | $130.00 | 270,336 | 132.00 | 2.06 | $35,143,680.00 | $17,160.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 284 | Generic 800G DR8 | $500.00 | 20,275 | 9.90 | 0.15 | $10,137,600.00 | $4,950.00 | 16 W | 324,403 W | 158 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 285 | Generic 800G DR8 | $500.00 | 81,101 | 39.60 | 0.62 | $40,550,400.00 | $19,800.00 | 16 W | 1,297,613 W | 634 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 286 | Generic 800G DR8 | $500.00 | 101,376 | 49.50 | 0.77 | $50,688,000.00 | $24,750.00 | 16 W | 1,622,016 W | 792 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 287 | Strada Whisper 112Gb/s 64 DP Absolute Connector (Female) | $14.08 | 393,216 | 192.00 | 3.00 | $5,536,481.28 | $2,703.36 | 0 W | 0 W | 0 W | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 288 | Strada Whisper 112Gb/s 64 DP Absolute Connector (Male) | $42.24 | 393,216 | 192.00 | 3.00 | $16,609,443.84 | $8,110.08 | 0 W | 0 W | 0 W | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 289 | Teton3 Backplane Chassis | $7,728.00 | 8,192 | 4.00 | 0.06 | $63,307,776.00 | $30,912.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Others | — | Device Level | — | — | — | — | Trainium3 | Scale-Up | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 290 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 8,026 | 3.92 | 0.06 | $40,128,000.00 | $19,593.75 | 450 W | 3,611,520 W | 1,763 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 291 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 422 | 0.21 | 0.00 | $2,112,000.00 | $1,031.25 | 450 W | 190,080 W | 93 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 292 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 1,426 | 0.70 | 0.01 | $27,799,200.00 | $13,573.83 | 1,200 W | 1,710,720 W | 835 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 293 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 1,742 | 0.85 | 0.01 | $33,976,800.00 | $16,590.23 | 1,200 W | 2,090,880 W | 1,021 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD-Nv6-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 294 | 112Gb/s TE Connectivity Madison Cable (1DP per cable) | $1.00 | 12,582,912 | 6,144.00 | 96.00 | $12,582,912.00 | $6,144.00 | — | — | — | Backplane | Amazon | TE | — | Device Level | — | 112G | PCIe | — | Trainium3 | Scale-Up | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 295 | 200G EFAv3 QSFP56 Flat Top DAC | $15.00 | 32,768 | 16.00 | 0.25 | $491,520.00 | $240.00 | 0 W | 0 W | 0 W | DAC | Amazon | Unassigned | — | Device Level | — | — | — | — | Trainium3 | Compute Tray | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 296 | Aries PCIe 5.0 x16 Retimer | $35.00 | 262,144 | 128.00 | 2.00 | $9,175,040.00 | $4,480.00 | 9 W | 2,359,296 W | 1,152 W | Retimer | Amazon | Astera | — | L1 Abstraction | — | — | — | — | Trainium3 | Compute Tray | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 297 | EFAv4 Nitro-v6 400G NIC | $480.00 | 139,264 | 17.00 | 1.06 | $66,846,720.00 | $8,160.00 | 50 W | 6,963,200 W | 850 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 298 | Generic 400G AEC | $250.00 | 33,792 | 16.50 | 0.26 | $8,448,000.00 | $4,125.00 | 12 W | 405,504 W | 198 W | AEC | Amazon | Astera | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 299 | Generic 400G AEC | $250.00 | 74,342 | 36.30 | 0.57 | $18,585,600.00 | $9,075.00 | 12 W | 892,109 W | 436 W | AEC | Amazon | Credo | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 300 | Generic 400G AEC | $250.00 | 27,034 | 13.20 | 0.21 | $6,758,400.00 | $3,300.00 | 12 W | 324,403 W | 158 W | AEC | Amazon | Marvell | — | Device Level | — | — | — | — | Trainium3 | Backend | AWS-Teton3 PD Ultra-Nv6-EFA | — | — | — | — | — | — | — | — | — | — | — | — | — | 500 | 4,600 | 21,500 | 33,400 | 35,000 | 35,000 | — | — | — | — | — | — | — | — | — | — | — | — | — |