Live DB — analyst tables
Test
XPU Shipments
NetworkingDB
Every Cluster BoM Summary row joined to its ClusterDB quarterly series — XPU counts, equipment units and equipment spend per quarter.
Live networking_db (read-only)6,421 rows · 4,391 with matched XPU seriesbuilt 7/23/2026, 11:16:18 AM
| # | Item | Unit Cost | Quantity (per Cluster) | Quantity (per Server) | Quantity (per XPU) | Extended Price for Cluster | Extended Price per Server | Power (W) per Unit | Extended Power (W) per Cluster | Extended Power (W) per Server | Device Type | Hyperscaler | Vendor | Manufacturer | Component | Speed | SerDes Speed | Protocol | Technology | XPU | Network | Tab Name | 1Q23 | 2Q23 | 3Q23 | 4Q23 | 1Q24 | 2Q24 | 3Q24 | 4Q24 | 1Q25 | 2Q25 | 3Q25 | 4Q25 | 1Q26 | 2Q26 | 3Q26 | 4Q26 | 1Q27 | 2Q27 | 3Q27 | 4Q27 | 1Q28 | 2Q28 | 3Q28 | 4Q28 | 1Q29 | 2Q29 | 3Q29 | 4Q29 | 1Q30 | 2Q30 | 3Q30 | 4Q30 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 101 | Generic 400G DR4 | $260.00 | 98,304 | 54.00 | 0.75 | $25,559,040.00 | $14,040.00 | 10 W | 983,040 W | 540 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | GB300 | Backend | AWS-GB300 NVL72 JBOK-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | $1,440,504.00 | $20,217,600.00 | $30,326,400.00 | $30,326,400.00 | $21,551,400.00 | $14,040,000.00 | $8,775,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 102 | Generic 400G Single Mode | $130.00 | 589,824 | 324.00 | 4.50 | $76,677,120.00 | $42,120.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | GB300 | Backend | AWS-GB300 NVL72 JBOK-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | $4,321,512.00 | $60,652,800.00 | $90,979,200.00 | $90,979,200.00 | $64,654,200.00 | $42,120,000.00 | $26,325,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 103 | Generic 800G DR8 | $500.00 | 39,322 | 21.60 | 0.30 | $19,660,800.00 | $10,800.00 | 16 W | 629,146 W | 346 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | GB300 | Backend | AWS-GB300 NVL72 JBOK-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | $1,108,080.00 | $15,552,000.00 | $23,328,000.00 | $23,328,000.00 | $16,578,000.00 | $10,800,000.00 | $6,750,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 104 | Generic 800G DR8 | $500.00 | 157,286 | 86.40 | 1.20 | $78,643,200.00 | $43,200.00 | 16 W | 2,516,582 W | 1,382 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | GB300 | Backend | AWS-GB300 NVL72 JBOK-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | $4,432,320.00 | $62,208,000.00 | $93,312,000.00 | $93,312,000.00 | $66,312,000.00 | $43,200,000.00 | $27,000,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 105 | Generic 800G DR8 | $500.00 | 196,608 | 108.00 | 1.50 | $98,304,000.00 | $54,000.00 | 16 W | 3,145,728 W | 1,728 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | GB300 | Backend | AWS-GB300 NVL72 JBOK-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | $5,540,400.00 | $77,760,000.00 | $116,640,000.00 | $116,640,000.00 | $82,890,000.00 | $54,000,000.00 | $33,750,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 106 | Generic PCIe Gen5 x16 (32Gb/s uni-di) 2-meter AEC | $350.00 | 262,144 | 144.00 | 2.00 | $91,750,400.00 | $50,400.00 | 3 W | 786,432 W | 432 W | AEC | Amazon | Astera | — | Device Level | — | — | PCIe | — | GB300 | Compute Tray | AWS-GB300 NVL72 JBOK-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | $5,171,040.00 | $72,576,000.00 | $108,864,000.00 | $108,864,000.00 | $77,364,000.00 | $50,400,000.00 | $31,500,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 107 | NV 224Gb/s SkewClear EXD Gen 2 Cable | $4.00 | 9,437,184 | 5,184.00 | 72.00 | $37,748,736.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB300 | Scale-Up | AWS-GB300 NVL72 JBOK-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | $2,127,513.60 | $29,859,840.00 | $44,789,760.00 | $44,789,760.00 | $31,829,760.00 | $20,736,000.00 | $12,960,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 108 | NV 2 UltraPass OverPass 144 DP 224Gb/s | $720.00 | 65,536 | 36.00 | 0.50 | $47,185,920.00 | $25,920.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | — | — | — | GB300 | Scale-Up | AWS-GB300 NVL72 JBOK-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | $2,659,392.00 | $37,324,800.00 | $55,987,200.00 | $55,987,200.00 | $39,787,200.00 | $25,920,000.00 | $16,200,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 109 | NV DensiLink OverPass to OSFP Cage | $37.50 | 131,072 | 72.00 | 1.00 | $4,915,200.00 | $2,700.00 | 0 W | 0 W | 0 W | Cable | Amazon | Amphenol | Amphenol | White Label | — | — | — | — | GB300 | Compute Tray | AWS-GB300 NVL72 JBOK-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | $277,020.00 | $3,888,000.00 | $5,832,000.00 | $5,832,000.00 | $4,144,500.00 | $2,700,000.00 | $1,687,500.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 110 | Nvidia NVSwitch 5.0 (NVLink 5) | $3,200.00 | 32,768 | 18.00 | 0.25 | $104,857,600.00 | $57,600.00 | 407 W | 13,349,683 W | 7,333 W | Scale-Up Switch | Amazon | Nvidia | — | Device Level | — | — | NVLink | — | GB300 | Scale-Up | AWS-GB300 NVL72 JBOK-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | $5,909,760.00 | $82,944,000.00 | $124,416,000.00 | $124,416,000.00 | $88,416,000.00 | $57,600,000.00 | $36,000,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 111 | NVL Spine Chassis (NvLink 5) | $150.00 | 3,641 | 2.00 | 0.03 | $546,133.33 | $300.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Others | Others | Device Level | — | — | NVLink | — | GB300 | Scale-Up | AWS-GB300 NVL72 JBOK-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | $30,780.00 | $432,000.00 | $648,000.00 | $648,000.00 | $460,500.00 | $300,000.00 | $187,500.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 112 | NV MCIO PCIe x16 Cable | $35.00 | 65,536 | 36.00 | 0.50 | $2,293,760.00 | $1,260.00 | 0 W | 0 W | 0 W | Cable | Amazon | Amphenol | Amphenol | White Label | — | — | — | — | GB300 | Compute Tray | AWS-GB300 NVL72 JBOK-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | $129,276.00 | $1,814,400.00 | $2,721,600.00 | $2,721,600.00 | $1,934,100.00 | $1,260,000.00 | $787,500.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 113 | NV MCIO PCIe x16 Connector | $1.25 | 65,536 | 36.00 | 0.50 | $81,920.00 | $45.00 | 0 W | 0 W | 0 W | Connector | Amazon | Amphenol | Amphenol | White Label | — | — | — | — | GB300 | Compute Tray | AWS-GB300 NVL72 JBOK-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | $4,617.00 | $64,800.00 | $97,200.00 | $97,200.00 | $69,075.00 | $45,000.00 | $28,125.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 114 | NV Paladin HD2 224Gb/s 144 DP (Female) | $288.00 | 65,536 | 36.00 | 0.50 | $18,874,368.00 | $10,368.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB300 | Scale-Up | AWS-GB300 NVL72 JBOK-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | $1,063,756.80 | $14,929,920.00 | $22,394,880.00 | $22,394,880.00 | $15,914,880.00 | $10,368,000.00 | $6,480,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 115 | NV Paladin HD2 224Gb/s 144 DP (Male) | $576.00 | 65,536 | 36.00 | 0.50 | $37,748,736.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB300 | Scale-Up | AWS-GB300 NVL72 JBOK-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | $2,127,513.60 | $29,859,840.00 | $44,789,760.00 | $44,789,760.00 | $31,829,760.00 | $20,736,000.00 | $12,960,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 116 | NV Paladin HD2 224Gb/s 72 DP (Female) | $144.00 | 131,072 | 72.00 | 1.00 | $18,874,368.00 | $10,368.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB300 | Scale-Up | AWS-GB300 NVL72 JBOK-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | $1,063,756.80 | $14,929,920.00 | $22,394,880.00 | $22,394,880.00 | $15,914,880.00 | $10,368,000.00 | $6,480,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 117 | NV Paladin HD2 224Gb/s 72 DP (Male) | $288.00 | 131,072 | 72.00 | 1.00 | $37,748,736.00 | $20,736.00 | 0 W | 0 W | 0 W | Backplane | Amazon | Nvidia | Amphenol | White Label | — | 224G | NVLink | — | GB300 | Scale-Up | AWS-GB300 NVL72 JBOK-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | $2,127,513.60 | $29,859,840.00 | $44,789,760.00 | $44,789,760.00 | $31,829,760.00 | $20,736,000.00 | $12,960,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 118 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 512 | 0.28 | 0.00 | $9,984,000.00 | $5,484.38 | 1,200 W | 614,400 W | 338 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | GB300 | Backend | AWS-GB300 NVL72 JBOK-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | $562,696.88 | $7,897,500.00 | $11,846,250.00 | $11,846,250.00 | $8,418,515.63 | $5,484,375.00 | $3,427,734.38 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 119 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 9,728 | 5.34 | 0.07 | $189,696,000.00 | $104,203.13 | 1,200 W | 11,673,600 W | 6,413 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | GB300 | Backend | AWS-GB300 NVL72 JBOK-EFA-WB | — | — | — | — | — | — | — | — | — | — | — | — | $10,691,240.63 | $150,052,500.00 | $225,078,750.00 | $225,078,750.00 | $159,951,796.88 | $104,203,125.00 | $65,126,953.13 | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 120 | Generic 100G AEC | $70.00 | 1,843 | 0.90 | 0.08 | $129,024.00 | $63.00 | 8 W | 14,746 W | 7 W | AEC | Amazon | Credo | — | Device Level | — | — | — | — | Inferentia2 | Backend | AWS-Inferentia2-Default | $123,480.00 | $97,874.00 | $178,234.00 | $234,948.00 | $197,680.00 | $282,758.00 | $385,000.00 | $332,500.00 | $245,000.00 | $12,342.75 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 121 | Generic 100G AEC | $70.00 | 205 | 0.10 | 0.01 | $14,336.00 | $7.00 | 8 W | 1,638 W | 1 W | AEC | Amazon | Others | — | Device Level | — | — | — | — | Inferentia2 | Backend | AWS-Inferentia2-Default | $13,720.00 | $10,874.89 | $19,803.78 | $26,105.33 | $21,964.44 | $31,417.56 | $42,777.78 | $36,944.44 | $27,222.22 | $1,371.42 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 122 | Generic 100G Multimode | $150.00 | 1,638 | 0.80 | 0.07 | $245,760.00 | $120.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Corning | — | Device Level | — | — | — | — | Inferentia2 | Backend | AWS-Inferentia2-Default | $235,200.00 | $186,426.67 | $339,493.33 | $447,520.00 | $376,533.33 | $538,586.67 | $733,333.33 | $633,333.33 | $466,666.67 | $23,510.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 123 | Generic 100G Multimode | $150.00 | 410 | 0.20 | 0.02 | $61,440.00 | $30.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | Inferentia2 | Backend | AWS-Inferentia2-Default | $58,800.00 | $46,606.67 | $84,873.33 | $111,880.00 | $94,133.33 | $134,646.67 | $183,333.33 | $158,333.33 | $116,666.67 | $5,877.50 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 124 | Generic 100G SR4 QSFP28 | $49.50 | 1,024 | 0.50 | 0.04 | $50,685.41 | $24.75 | 3 W | 3,072 W | 2 W | Transceiver | Amazon | Coherent | — | Device Level | — | 28G | Ethernet | Fully Retimed | Inferentia2 | Backend | AWS-Inferentia2-Default | $48,507.53 | $38,448.54 | $70,016.93 | $92,296.29 | $77,656.04 | $111,077.83 | $151,242.28 | $130,618.34 | $96,245.09 | $4,848.69 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 125 | Generic 100G SR4 QSFP28 | $49.50 | 1,024 | 0.50 | 0.04 | $50,685.41 | $24.75 | 3 W | 3,072 W | 2 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 28G | Ethernet | Fully Retimed | Inferentia2 | Backend | AWS-Inferentia2-Default | $48,507.53 | $38,448.54 | $70,016.93 | $92,296.29 | $77,656.04 | $111,077.83 | $151,242.28 | $130,618.34 | $96,245.09 | $4,848.69 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 126 | Generic 100G SR4 QSFP28 | $49.50 | 819 | 0.40 | 0.03 | $40,548.33 | $19.80 | 3 W | 2,458 W | 1 W | Transceiver | Amazon | Innolight | — | Device Level | — | 28G | Ethernet | Fully Retimed | Inferentia2 | Backend | AWS-Inferentia2-Default | $38,806.02 | $30,758.83 | $56,013.54 | $73,837.03 | $62,124.83 | $88,862.27 | $120,993.83 | $104,494.67 | $76,996.07 | $3,878.95 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 127 | Generic 100G SR4 QSFP28 | $49.50 | 1,229 | 0.60 | 0.05 | $60,822.50 | $29.70 | 3 W | 3,686 W | 2 W | Transceiver | Amazon | Others | — | Device Level | — | 28G | Ethernet | Fully Retimed | Inferentia2 | Backend | AWS-Inferentia2-Default | $58,209.03 | $46,138.25 | $84,020.31 | $110,755.55 | $93,187.25 | $133,293.40 | $181,490.74 | $156,742.00 | $115,494.11 | $5,818.43 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 128 | NIC - 100G | $250.00 | 2,048 | 1.00 | 0.08 | $512,000.00 | $250.00 | 38 W | 77,824 W | 38 W | NIC | Amazon | Unassigned | — | Device Level | — | — | — | — | Inferentia2 | Backend | AWS-Inferentia2-Default | $490,000.00 | $388,388.89 | $707,277.78 | $932,333.33 | $784,444.44 | $1,122,055.56 | $1,527,777.78 | $1,319,444.44 | $972,222.22 | $48,979.17 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 129 | WhiteBox Tomahawk 2 6.4T | $3,072.57 | 61 | 0.03 | 0.00 | $186,812.31 | $91.22 | 250 W | 15,200 W | 7 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Inferentia2 | Backend | AWS-Inferentia2-Default | $178,785.22 | $141,710.60 | $258,062.89 | $340,178.41 | $286,218.52 | $409,401.94 | $557,436.92 | $481,422.79 | $354,732.58 | $17,870.92 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 130 | WhiteBox Tomahawk 2 6.4T | $3,072.57 | 3 | 0.00 | 0.00 | $9,832.23 | $4.80 | 250 W | 800 W | 0 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Inferentia2 | Backend | AWS-Inferentia2-Default | $9,409.75 | $7,458.45 | $13,582.26 | $17,904.13 | $15,064.13 | $21,547.47 | $29,338.79 | $25,338.04 | $18,670.14 | $940.57 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 131 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 2 | 0.00 | 0.00 | $8,000.00 | $3.91 | 450 W | 720 W | 0 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Inferentia2 | Backend | AWS-Inferentia2-Default | $7,656.25 | $6,068.58 | $11,051.22 | $14,567.71 | $12,256.94 | $17,532.12 | $23,871.53 | $20,616.32 | $15,190.97 | $765.30 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 132 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 14 | 0.01 | 0.00 | $72,000.00 | $35.16 | 450 W | 6,480 W | 3 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Inferentia2 | Backend | AWS-Inferentia2-Default | $68,906.25 | $54,617.19 | $99,460.94 | $131,109.38 | $110,312.50 | $157,789.06 | $214,843.75 | $185,546.87 | $136,718.75 | $6,887.70 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 133 | EFAv3 Nitro-v5 200G NIC | $300.00 | 24,576 | 72.00 | 1.00 | $7,372,800.00 | $21,600.00 | 38 W | 933,888 W | 2,736 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | Inferentia3 | Backend | AWS-Inferentia3-Default | — | — | — | — | — | — | — | — | $463,200.00 | $1,821,600.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 134 | Generic 200G AEC | $70.00 | 8,192 | 24.00 | 0.33 | $573,440.00 | $1,680.00 | 12 W | 98,304 W | 288 W | AEC | Amazon | Astera | — | Device Level | — | — | — | — | Inferentia3 | Backend | AWS-Inferentia3-Default | — | — | — | — | — | — | — | — | $36,026.67 | $141,680.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 135 | Generic 200G AEC | $70.00 | 8,192 | 24.00 | 0.33 | $573,440.00 | $1,680.00 | 12 W | 98,304 W | 288 W | AEC | Amazon | Credo | — | Device Level | — | — | — | — | Inferentia3 | Backend | AWS-Inferentia3-Default | — | — | — | — | — | — | — | — | $36,026.67 | $141,680.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 136 | Generic 200G AEC | $70.00 | 8,192 | 24.00 | 0.33 | $573,440.00 | $1,680.00 | 12 W | 98,304 W | 288 W | AEC | Amazon | Marvell | — | Device Level | — | — | — | — | Inferentia3 | Backend | AWS-Inferentia3-Default | — | — | — | — | — | — | — | — | $36,026.67 | $141,680.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 137 | Generic 200G Multimode | $150.00 | 78,643 | 230.40 | 3.20 | $11,796,480.00 | $34,560.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Corning | — | Device Level | — | — | — | — | Inferentia3 | Backend | AWS-Inferentia3-Default | — | — | — | — | — | — | — | — | $741,120.00 | $2,914,560.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 138 | Generic 200G Multimode | $150.00 | 19,661 | 57.60 | 0.80 | $2,949,120.00 | $8,640.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | Inferentia3 | Backend | AWS-Inferentia3-Default | — | — | — | — | — | — | — | — | $185,280.00 | $728,640.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 139 | Generic 200G SR4 QSFP56 | $130.00 | 9,830 | 28.80 | 0.40 | $1,277,952.00 | $3,744.00 | 5 W | 49,152 W | 144 W | Transceiver | Amazon | AAOI | — | Device Level | — | 56G | Ethernet | Fully Retimed | Inferentia3 | Backend | AWS-Inferentia3-Default | — | — | — | — | — | — | — | — | $80,288.00 | $315,744.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 140 | Generic 200G SR4 QSFP56 | $130.00 | 9,830 | 28.80 | 0.40 | $1,277,952.00 | $3,744.00 | 5 W | 49,152 W | 144 W | Transceiver | Amazon | Coherent | — | Device Level | — | 56G | Ethernet | Fully Retimed | Inferentia3 | Backend | AWS-Inferentia3-Default | — | — | — | — | — | — | — | — | $80,288.00 | $315,744.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 141 | Generic 200G SR4 QSFP56 | $130.00 | 54,067 | 158.40 | 2.20 | $7,028,736.00 | $20,592.00 | 5 W | 270,336 W | 792 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 56G | Ethernet | Fully Retimed | Inferentia3 | Backend | AWS-Inferentia3-Default | — | — | — | — | — | — | — | — | $441,584.00 | $1,736,592.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 142 | Generic 200G SR4 QSFP56 | $130.00 | 24,576 | 72.00 | 1.00 | $3,194,880.00 | $9,360.00 | 5 W | 122,880 W | 360 W | Transceiver | Amazon | Innolight | — | Device Level | — | 56G | Ethernet | Fully Retimed | Inferentia3 | Backend | AWS-Inferentia3-Default | — | — | — | — | — | — | — | — | $200,720.00 | $789,360.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 143 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 134 | 0.39 | 0.01 | $672,000.00 | $1,968.75 | 450 W | 60,480 W | 177 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | Inferentia3 | Backend | AWS-Inferentia3-Default | — | — | — | — | — | — | — | — | $42,218.75 | $166,031.25 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 144 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 1,210 | 3.54 | 0.05 | $6,048,000.00 | $17,718.75 | 450 W | 544,320 W | 1,595 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | Inferentia3 | Backend | AWS-Inferentia3-Default | — | — | — | — | — | — | — | — | $379,968.75 | $1,494,281.25 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 145 | EFAv3 Nitro-v5 200G NIC | $300.00 | 4,096 | 16.00 | 2.00 | $1,228,800.00 | $4,800.00 | 38 W | 155,648 W | 608 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | MI350X | Backend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $7,200,000.00 | $4,800,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 146 | Generic 100G Multimode | $150.00 | 234 | 0.91 | 0.11 | $35,078.10 | $137.02 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | MI350X | Frontend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $205,535.71 | $137,023.81 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 147 | Generic 100G SR4 QSFP28 | $49.50 | 131 | 0.51 | 0.06 | $6,496.58 | $25.38 | 3 W | 394 W | 2 W | Transceiver | Amazon | Coherent | — | Device Level | — | 28G | Ethernet | Fully Retimed | MI350X | Frontend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $38,065.92 | $25,377.28 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 148 | Generic 100G SR4 QSFP28 | $49.50 | 131 | 0.51 | 0.06 | $6,496.58 | $25.38 | 3 W | 394 W | 2 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 28G | Ethernet | Fully Retimed | MI350X | Frontend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $38,065.92 | $25,377.28 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 149 | Generic 100G SR4 QSFP28 | $49.50 | 105 | 0.41 | 0.05 | $5,197.27 | $20.30 | 3 W | 315 W | 1 W | Transceiver | Amazon | Innolight | — | Device Level | — | 28G | Ethernet | Fully Retimed | MI350X | Frontend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $30,452.73 | $20,301.82 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 150 | Generic 100G SR4 QSFP28 | $49.50 | 158 | 0.62 | 0.08 | $7,795.90 | $30.45 | 3 W | 473 W | 2 W | Transceiver | Amazon | Others | — | Device Level | — | 28G | Ethernet | Fully Retimed | MI350X | Frontend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $45,679.10 | $30,452.73 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 151 | Generic 1GbE Ethernet | $350.00 | 29 | 0.11 | 0.01 | $9,998.22 | $39.06 | 100 W | 2,857 W | 11 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | MI350X | Frontend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $58,583.33 | $39,055.56 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 152 | Generic 1GbE Ethernet | $350.00 | 2 | 0.01 | 0.00 | $526.22 | $2.06 | 100 W | 150 W | 1 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | MI350X | Frontend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $3,083.33 | $2,055.56 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 153 | Generic 400G DR4 | $260.00 | 819 | 3.20 | 0.40 | $212,992.00 | $832.00 | 10 W | 8,192 W | 32 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | MI350X | Backend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $1,248,000.00 | $832,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 154 | Generic 400G DR4 | $260.00 | 1,229 | 4.80 | 0.60 | $319,488.00 | $1,248.00 | 10 W | 12,288 W | 48 W | Transceiver | Amazon | Coherent | — | Device Level | — | 112G | Ethernet | Fully Retimed | MI350X | Backend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $1,872,000.00 | $1,248,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 155 | Generic 400G DR4 | $260.00 | 4,096 | 16.00 | 2.00 | $1,064,960.00 | $4,160.00 | 10 W | 40,960 W | 160 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | MI350X | Backend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $6,240,000.00 | $4,160,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 156 | Generic 400G DR4 | $260.00 | 2,048 | 8.00 | 1.00 | $532,480.00 | $2,080.00 | 10 W | 20,480 W | 80 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | MI350X | Backend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $3,120,000.00 | $2,080,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 157 | Generic 400G Multimode | $150.00 | 8 | 0.03 | 0.00 | $1,249.52 | $4.88 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | MI350X | Frontend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $7,321.43 | $4,880.95 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 158 | Generic 400G Single Mode | $130.00 | 4,096 | 16.00 | 2.00 | $532,480.00 | $2,080.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | MI350X | Backend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $3,120,000.00 | $2,080,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 159 | Generic 400G SR4 | $230.00 | 118 | 0.46 | 0.06 | $27,210.97 | $106.29 | 9 W | 1,065 W | 4 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | MI350X | Frontend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $159,439.29 | $106,292.86 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 160 | Generic 400G SR4 | $230.00 | 177 | 0.69 | 0.09 | $40,816.46 | $159.44 | 9 W | 1,597 W | 6 W | Transceiver | Amazon | Coherent | — | Device Level | — | 112G | Ethernet | Fully Retimed | MI350X | Frontend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $239,158.93 | $159,439.29 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 161 | Generic 400G SR4 | $230.00 | 592 | 2.31 | 0.29 | $136,054.86 | $531.46 | 9 W | 5,324 W | 21 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | MI350X | Frontend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $797,196.43 | $531,464.29 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 162 | Generic 400G SR4 | $230.00 | 296 | 1.16 | 0.14 | $68,027.43 | $265.73 | 9 W | 2,662 W | 10 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | MI350X | Frontend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $398,598.21 | $265,732.14 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 163 | Generic 800G Multimode | $210.00 | 1,628 | 6.36 | 0.79 | $341,802.67 | $1,335.17 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | MI350X | Frontend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $2,002,750.00 | $1,335,166.67 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 164 | Generic 800G SR8 | $400.00 | 119 | 0.46 | 0.06 | $47,571.30 | $185.83 | 14 W | 1,665 W | 7 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | MI350X | Frontend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $278,738.10 | $185,825.40 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 165 | Generic 800G SR8 | $400.00 | 476 | 1.86 | 0.23 | $190,285.21 | $743.30 | 14 W | 6,660 W | 26 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | MI350X | Frontend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $1,114,952.38 | $743,301.59 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 166 | Generic 800G SR8 | $400.00 | 595 | 2.32 | 0.29 | $237,856.51 | $929.13 | 14 W | 8,325 W | 33 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | MI350X | Frontend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $1,393,690.48 | $929,126.98 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 167 | Paladin Board to Board 32 Pin 4p8c (Female) | $8.00 | 2,048 | 8.00 | 1.00 | $16,384.00 | $64.00 | 0 W | 0 W | 0 W | Midplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | MI350X | Compute Tray | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $96,000.00 | $64,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 168 | Paladin Board to Board 32 Pin 4p8c (Male) | $16.00 | 2,048 | 8.00 | 1.00 | $32,768.00 | $128.00 | 0 W | 0 W | 0 W | Midplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | MI350X | Compute Tray | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $192,000.00 | $128,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 169 | Paladin Board to Board 64 Pin 4p16c (Female) | $16.00 | 8,192 | 32.00 | 4.00 | $131,072.00 | $512.00 | 0 W | 0 W | 0 W | Midplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | MI350X | Compute Tray | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $768,000.00 | $512,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 170 | Paladin Board to Board 64 Pin 4p16c (Male) | $32.00 | 8,192 | 32.00 | 4.00 | $262,144.00 | $1,024.00 | 0 W | 0 W | 0 W | Midplane | Amazon | Amphenol | — | Device Level | — | 224G | — | — | MI350X | Compute Tray | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $1,536,000.00 | $1,024,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 171 | RJ45 Cables | $1.00 | 1,443 | 5.64 | 0.70 | $1,443.35 | $5.64 | 0 W | 0 W | 0 W | Cable | Amazon | Amphenol | — | Device Level | — | — | — | — | MI350X | Frontend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $8,457.14 | $5,638.10 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 172 | WhiteBox Tomahawk 2 6.4T | $3,072.57 | 3 | 0.01 | 0.00 | $10,674.99 | $41.70 | 250 W | 869 W | 3 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | MI350X | Frontend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $62,548.77 | $41,699.18 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 173 | WhiteBox Tomahawk 2 6.4T | $3,072.57 | 0 | 0.00 | 0.00 | $561.84 | $2.19 | 250 W | 46 W | 0 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | MI350X | Frontend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $3,292.04 | $2,194.69 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 174 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 99 | 0.39 | 0.05 | $492,973.44 | $1,925.68 | 450 W | 44,368 W | 173 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | MI350X | Backend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $2,888,516.25 | $1,925,677.50 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 175 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 93 | 0.36 | 0.05 | $467,026.56 | $1,824.32 | 450 W | 42,032 W | 164 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | MI350X | Backend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $2,736,483.75 | $1,824,322.50 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 176 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 0 | 0.00 | 0.00 | $260.83 | $1.02 | 450 W | 23 W | 0 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | MI350X | Frontend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $1,528.31 | $1,018.87 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 177 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 0 | 0.00 | 0.00 | $247.10 | $0.97 | 450 W | 22 W | 0 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | MI350X | Frontend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $1,447.87 | $965.25 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 178 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 1 | 0.00 | 0.00 | $23,969.52 | $93.63 | 1,200 W | 1,475 W | 6 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | MI350X | Frontend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $140,446.43 | $93,630.95 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 179 | WhiteBox Tomahawk 5 51.2T | $19,500.00 | 23 | 0.09 | 0.01 | $455,420.95 | $1,778.99 | 1,200 W | 28,026 W | 109 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | MI350X | Frontend | AWS-MI350X-Nv5-EFA-2L | — | — | — | — | — | — | — | — | — | — | — | $2,668,482.14 | $1,778,988.10 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 180 | Broadcom PEX89144 Gen 5.0 144L | $664.62 | 16,384 | 4.00 | 0.50 | $10,889,058.47 | $2,658.46 | 240 W | 3,932,160 W | 960 W | Switch | Amazon | Broadcom | — | Device Level | — | — | — | — | A100 | Compute Tray | AWS-P4d-A100 NVL8-EFA-WB | $52,826,289.26 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 181 | Generic 200G DR4 QSFP56 | $150.00 | 4,096 | 1.00 | 0.13 | $614,400.00 | $150.00 | 5 W | 20,480 W | 5 W | Transceiver | Amazon | AAOI | — | Device Level | — | 56G | Ethernet | Fully Retimed | A100 | Backend | AWS-P4d-A100 NVL8-EFA-WB | $2,980,650.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 182 | Generic 200G DR4 QSFP56 | $150.00 | 4,096 | 1.00 | 0.13 | $614,400.00 | $150.00 | 5 W | 20,480 W | 5 W | Transceiver | Amazon | Coherent | — | Device Level | — | 56G | Ethernet | Fully Retimed | A100 | Backend | AWS-P4d-A100 NVL8-EFA-WB | $2,980,650.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 183 | Generic 200G DR4 QSFP56 | $150.00 | 22,528 | 5.50 | 0.69 | $3,379,200.00 | $825.00 | 5 W | 112,640 W | 28 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 56G | Ethernet | Fully Retimed | A100 | Backend | AWS-P4d-A100 NVL8-EFA-WB | $16,393,575.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 184 | Generic 200G DR4 QSFP56 | $150.00 | 10,240 | 2.50 | 0.31 | $1,536,000.00 | $375.00 | 5 W | 51,200 W | 13 W | Transceiver | Amazon | Innolight | — | Device Level | — | 56G | Ethernet | Fully Retimed | A100 | Backend | AWS-P4d-A100 NVL8-EFA-WB | $7,451,625.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 185 | Generic 200G Single Mode | $130.00 | 16,384 | 4.00 | 0.50 | $2,129,920.00 | $520.00 | 0 W | 0 W | 0 W | Fiber | Amazon | Others | — | Device Level | — | — | — | — | A100 | Backend | AWS-P4d-A100 NVL8-EFA-WB | $10,332,920.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 186 | Generic 200G Y Cable AEC | $70.00 | 5,461 | 1.33 | 0.17 | $382,293.33 | $93.33 | 12 W | 65,536 W | 16 W | AEC | Amazon | Astera | — | Device Level | — | — | — | — | A100 | Backend | AWS-P4d-A100 NVL8-EFA-WB | $1,854,626.67 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 187 | Generic 200G Y Cable AEC | $70.00 | 5,461 | 1.33 | 0.17 | $382,293.33 | $93.33 | 12 W | 65,536 W | 16 W | AEC | Amazon | Credo | — | Device Level | — | — | — | — | A100 | Backend | AWS-P4d-A100 NVL8-EFA-WB | $1,854,626.67 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 188 | Generic 200G Y Cable AEC | $70.00 | 5,461 | 1.33 | 0.17 | $382,293.33 | $93.33 | 12 W | 65,536 W | 16 W | AEC | Amazon | Marvell | — | Device Level | — | — | — | — | A100 | Backend | AWS-P4d-A100 NVL8-EFA-WB | $1,854,626.67 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 189 | Generic PCIe Gen5 x16 2-meter DAC | $82.00 | 32,768 | 8.00 | 1.00 | $2,686,976.00 | $656.00 | 0 W | 0 W | 0 W | DAC | Amazon | Unassigned | — | Device Level | — | — | PCIe | — | A100 | Compute Tray | AWS-P4d-A100 NVL8-EFA-WB | $13,035,376.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 190 | Nvidia NVSwitch 2.0 (NVLink 3) | $666.67 | 24,576 | 6.00 | 0.75 | $16,384,000.01 | $4,000.00 | 255 W | 6,275,378 W | 1,532 W | Scale-Up Switch | Amazon | Nvidia | — | Device Level | — | — | NVLink | — | A100 | Scale-Up | AWS-P4d-A100 NVL8-EFA-WB | $79,484,000.04 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 191 | WhiteBox Tomahawk 2 6.4T | $3,072.57 | 486 | 0.12 | 0.01 | $1,494,498.51 | $364.87 | 250 W | 121,600 W | 30 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | A100 | Backend | AWS-P4d-A100 NVL8-EFA-WB | $7,250,288.04 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 192 | WhiteBox Tomahawk 2 6.4T | $3,072.57 | 26 | 0.01 | 0.00 | $78,657.82 | $19.20 | 250 W | 6,400 W | 2 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | A100 | Backend | AWS-P4d-A100 NVL8-EFA-WB | $381,594.11 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 193 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 365 | 0.09 | 0.01 | $1,824,000.00 | $445.31 | 450 W | 164,160 W | 40 W | Switch | Amazon | Accton | — | Device Level | — | — | — | — | A100 | Backend | AWS-P4d-A100 NVL8-EFA-WB | $8,848,804.69 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 194 | WhiteBox Tomahawk 3 12.8T | $5,000.00 | 19 | 0.00 | 0.00 | $96,000.00 | $23.44 | 450 W | 8,640 W | 2 W | Switch | Amazon | Celestica | — | Device Level | — | — | — | — | A100 | Backend | AWS-P4d-A100 NVL8-EFA-WB | $465,726.56 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 195 | Broadcom PEX89144 Gen 5.0 144L | $664.62 | 65,536 | 4.00 | 0.50 | $43,556,233.87 | $2,658.46 | 240 W | 15,728,640 W | 960 W | Switch | Amazon | Broadcom | — | Device Level | — | — | — | — | H100 | Compute Tray | AWS-P5en-H100 NVL8-EFA-WB | $1,369,107.69 | $1,313,280.00 | $3,926,547.69 | $3,732,480.00 | $17,880,812.32 | $26,962,116.94 | $33,201,526.17 | $35,019,913.87 | $16,131,544.62 | $9,969,230.77 | $6,646,153.85 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 196 | EFAv3 Nitro-v5 200G NIC | $300.00 | 262,144 | 16.00 | 2.00 | $78,643,200.00 | $4,800.00 | 38 W | 9,961,472 W | 608 W | NIC | Amazon | Amazon | — | Device Level | — | — | — | — | H100 | Backend | AWS-P5en-H100 NVL8-EFA-WB | $2,472,000.00 | $2,371,200.00 | $7,089,600.00 | $6,739,200.00 | $32,284,800.00 | $48,681,600.00 | $59,947,200.00 | $63,230,400.00 | $29,126,400.00 | $18,000,000.00 | $12,000,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 197 | Generic 400G DR4 | $260.00 | 52,429 | 3.20 | 0.40 | $13,631,488.00 | $832.00 | 10 W | 524,288 W | 32 W | Transceiver | Amazon | AAOI | — | Device Level | — | 112G | Ethernet | Fully Retimed | H100 | Backend | AWS-P5en-H100 NVL8-EFA-WB | $428,480.00 | $411,008.00 | $1,228,864.00 | $1,168,128.00 | $5,596,032.00 | $8,438,144.00 | $10,390,848.00 | $10,959,936.00 | $5,048,576.00 | $3,120,000.00 | $2,080,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 198 | Generic 400G DR4 | $260.00 | 78,643 | 4.80 | 0.60 | $20,447,232.00 | $1,248.00 | 10 W | 786,432 W | 48 W | Transceiver | Amazon | Coherent | — | Device Level | — | 112G | Ethernet | Fully Retimed | H100 | Backend | AWS-P5en-H100 NVL8-EFA-WB | $642,720.00 | $616,512.00 | $1,843,296.00 | $1,752,192.00 | $8,394,048.00 | $12,657,216.00 | $15,586,272.00 | $16,439,904.00 | $7,572,864.00 | $4,680,000.00 | $3,120,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 199 | Generic 400G DR4 | $260.00 | 262,144 | 16.00 | 2.00 | $68,157,440.00 | $4,160.00 | 10 W | 2,621,440 W | 160 W | Transceiver | Amazon | Eoptolink | — | Device Level | — | 112G | Ethernet | Fully Retimed | H100 | Backend | AWS-P5en-H100 NVL8-EFA-WB | $2,142,400.00 | $2,055,040.00 | $6,144,320.00 | $5,840,640.00 | $27,980,160.00 | $42,190,720.00 | $51,954,240.00 | $54,799,680.00 | $25,242,880.00 | $15,600,000.00 | $10,400,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 200 | Generic 400G DR4 | $260.00 | 131,072 | 8.00 | 1.00 | $34,078,720.00 | $2,080.00 | 10 W | 1,310,720 W | 80 W | Transceiver | Amazon | Innolight | — | Device Level | — | 112G | Ethernet | Fully Retimed | H100 | Backend | AWS-P5en-H100 NVL8-EFA-WB | $1,071,200.00 | $1,027,520.00 | $3,072,160.00 | $2,920,320.00 | $13,990,080.00 | $21,095,360.00 | $25,977,120.00 | $27,399,840.00 | $12,621,440.00 | $7,800,000.00 | $5,200,000.00 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |